Author
Michael Hocke
Other affiliations: Zhengzhou University
Bio: Michael Hocke is an academic researcher from University of Jena. The author has contributed to research in topics: Endoscopic ultrasound & Pancreatitis. The author has an hindex of 35, co-authored 110 publications receiving 4167 citations. Previous affiliations of Michael Hocke include Zhengzhou University.
Papers published on a yearly basis
Papers
More filters
••
University of Bologna1, University of Copenhagen2, Imperial College London3, University of Bergen4, University of Trieste5, Ludwig Maximilian University of Munich6, University of Paris7, University of Verona8, Sapienza University of Rome9, University of Regensburg10, Innsbruck Medical University11, Institut Gustave Roussy12, Hai phong University Of Medicine and Pharmacy13, University of Cambridge14, The Royal Marsden NHS Foundation Trust15, Katholieke Universiteit Leuven16
TL;DR: Authors F. Piscaglia, C. Nolsøe, M. M. Gilja, and H. P. Weskott review the manuscript and suggest ways in which the manuscript could have been improved.
Abstract: Authors F. Piscaglia1, C. Nolsøe2, C. F. Dietrich3, D. O. Cosgrove4, O. H. Gilja5, M. Bachmann Nielsen6, T. Albrecht7, L. Barozzi8, M. Bertolotto9, O. Catalano10, M. Claudon11, D. A. Clevert12, J. M. Correas13, M. D’Onofrio14, F. M. Drudi15, J. Eyding16, M. Giovannini17, M. Hocke18, A. Ignee19, E. M. Jung20, A. S. Klauser21, N. Lassau22, E. Leen23, G. Mathis24, A. Saftoiu25, G. Seidel26, P. S. Sidhu27, G. ter. Haar28, D. Timmerman29, H. P. Weskott30
975 citations
••
TL;DR: Contrast-enhanced endoscopic ultrasound improves the differentiation between chronic pancreatitis and pancreatic carcinoma based on perfusion characteristics of microvessels.
Abstract: AIM: To evaluate the contrast-enhanced endosonography as a method of differentiating inflammation from pancreatic carcinoma based on perfusion characteristics of microvessels.
METHODS: In 86 patients with suspected chronic pancreatitis (age: 62 ± 12 years; sex: f/m 38/48), pancreatic lesions were examined by conventional endoscopic B-mode, power Doppler ultrasound and contrast-enhanced power mode (Hitachi EUB 525, SonoVue®, 2.4 mL, Bracco) using the following criteria for malignant lesions: no detectable vascularisation using conventional power Doppler scanning, irregular appearance of arterial vessels over a short distance using SonoVue® contrast-enhanced technique and no detectable venous vessels inside the lesion. A malignant lesion was assumed if all criteria were detectable [gold standard endoscopic ultrasound (EUS)-guided fine needle aspiration cytology, operation]. The criteria of chronic pancreatitis without neoplasia were defined as no detectable vascularisation before injection of SonoVue®, regular appearance of vessels over a distance of at least 20 mm after injection of SonoVue® and detection of arterial and venous vessels.
RESULTS: The sensitivity and specificity of conventional EUS were 73.2% and 83.3% respectively for pancreatic cancer. The sensitivity of contrast-enhanced EUS increased to 91.1% in 51 of 56 patients with malignant pancreatic lesion and the specificity increased to 93.3% in 28 of 30 patients with chronic inflammatory pancreatic disease.
CONCLUSION: Contrast-enhanced endoscopic ultrasound improves the differentiation between chronic pancreatitis and pancreatic carcinoma.
211 citations
••
University of Medicine and Pharmacy of Craiova1, University of Bergen2, King's College London3, Copenhagen University Hospital4, Ruhr University Bochum5, University of Pavia6, Ludwig Maximilian University of Munich7, Paris Descartes University8, University of Verona9, University of Bologna10, Innsbruck Medical University11, Medical University of Vienna12, University of Latvia13, Guy's and St Thomas' NHS Foundation Trust14, University of Milan15, Iuliu Hațieganu University of Medicine and Pharmacy16, French Institute of Health and Medical Research17
TL;DR: This manuscript describes the use of ultrasound elastography, with the exception of liver applications, and represents an update of the 2013 EFSUMB (European Federation of Societies for Ultrasound in Medicine and Biology) Guidelines and Recommendations on the clinical use ofElastography.
Abstract: This manuscript describes the use of ultrasound elastography, with the exception of liver applications, and represents an update of the 2013 EFSUMB (European Federation of Societies for Ultrasound in Medicine and Biology) Guidelines and Recommendations on the clinical use of elastography.
190 citations
••
TL;DR: In this paper, a contrast-enhanced endoscopic ultrasound (CE-EDUS) was used for further characterization and differentiation of solid pancreatic tumors, showing that the vascular pattern of the lesion during the arterial phase was compared with the vascularity of the residual pancreatic parenchyma.
176 citations
••
TL;DR: The accuracy of real-time EUS elastography in focal pancreatic lesions using computer-aided diagnosis by artificial neural network analysis is assessed, providing fast and accurate diagnoses.
159 citations
Cited by
More filters
••
TL;DR: The following Clinical Practice Guidelines will give up-to-date advice for the clinical management of patients with hepatocellular carcinoma, as well as providing an in-depth review of all the relevant data leading to the conclusions herein.
7,851 citations
••
Seoul National University1, Hammersmith Hospital2, Kindai University3, University of Copenhagen4, University of Bologna5, University of Calgary6, Northeast Ohio Medical University7, University of São Paulo8, Jaslok Hospital9, Peking Union Medical College10, Ludwig Maximilian University of Munich11, University of Paris12, Fudan University13, Thomas Jefferson University14, University of Michigan15, University of Melbourne16, Institut Gustave Roussy17, Imperial College London18, University of California, San Diego19, Tokyo Medical University20, Tongji University21
TL;DR: These liver CEUS guidelines and recommendations are intended to create standard protocols for the use and administration of UCA in liver applications on an international basis and improve the management of patients worldwide.
Abstract: Initially, a set of guidelines for the use of ultrasound contrast agents was published in 2004 dealing only with liver applications. A second edition of the guidelines in 2008 reflected changes in the available contrast agents and updated the guidelines for the liver, as well as implementing some non-liver applications. Time has moved on, and the need for international guidelines on the use of CEUS in the liver has become apparent. The present document describes the third iteration of recommendations for the hepatic use of contrast enhanced ultrasound (CEUS) using contrast specific imaging techniques. This joint WFUMB-EFSUMB initiative has implicated experts from major leading ultrasound societies worldwide. These liver CEUS guidelines are simultaneously published in the official journals of both organizing federations (i.e., Ultrasound in Medicine and Biology for WFUMB and Ultraschall in der Medizin/European Journal of Ultrasound for EFSUMB). These guidelines and recommendations provide general advice on the use of all currently clinically available ultrasound contrast agents (UCA). They are intended to create standard protocols for the use and administration of UCA in liver applications on an international basis and improve the management of patients worldwide.
1,042 citations
••
Goethe University Frankfurt1, University of Pavia2, Policlinico Umberto I3, Paris Descartes University4, University of Verona5, École Normale Supérieure6, University of Bergen7, Haukeland University Hospital8, Innsbruck Medical University9, University of Medicine and Pharmacy of Craiova10, University of Bologna11
TL;DR: The technical part of these Guidelines and Recommendations provides an introduction to the physical principles and technology on which all forms of current commercially available ultrasound elastography are based.
Abstract: The technical part of these Guidelines and Recommendations, produced under the auspices of EFSUMB, provides an introduction to the physical principles and technology on which all forms of current commercially available ultrasound elastography are based. A difference in shear modulus is the common underlying physical mechanism that provides tissue contrast in all elastograms. The relationship between the alternative technologies is considered in terms of the method used to take advantage of this. The practical advantages and disadvantages associated with each of the techniques are described, and guidance is provided on optimisation of scanning technique, image display, image interpretation and some of the known image artefacts.
1,020 citations
••
University of Bologna1, University of Copenhagen2, Imperial College London3, University of Bergen4, University of Trieste5, Ludwig Maximilian University of Munich6, University of Paris7, University of Verona8, Sapienza University of Rome9, University of Regensburg10, Innsbruck Medical University11, Institut Gustave Roussy12, Hai phong University Of Medicine and Pharmacy13, University of Cambridge14, The Royal Marsden NHS Foundation Trust15, Katholieke Universiteit Leuven16
TL;DR: Authors F. Piscaglia, C. Nolsøe, M. M. Gilja, and H. P. Weskott review the manuscript and suggest ways in which the manuscript could have been improved.
Abstract: Authors F. Piscaglia1, C. Nolsøe2, C. F. Dietrich3, D. O. Cosgrove4, O. H. Gilja5, M. Bachmann Nielsen6, T. Albrecht7, L. Barozzi8, M. Bertolotto9, O. Catalano10, M. Claudon11, D. A. Clevert12, J. M. Correas13, M. D’Onofrio14, F. M. Drudi15, J. Eyding16, M. Giovannini17, M. Hocke18, A. Ignee19, E. M. Jung20, A. S. Klauser21, N. Lassau22, E. Leen23, G. Mathis24, A. Saftoiu25, G. Seidel26, P. S. Sidhu27, G. ter. Haar28, D. Timmerman29, H. P. Weskott30
975 citations