scispace - formally typeset
Search or ask a question
Author

Michael J. Fuerstman

Bio: Michael J. Fuerstman is an academic researcher from Harvard University. The author has contributed to research in topics: Pressure drop & Microchannel. The author has an hindex of 12, co-authored 13 publications receiving 3277 citations.

Papers
More filters
Journal ArticleDOI
TL;DR: Experimental results support the assertion that the dominant contribution to the dynamics of break-up arises from the pressure drop across the emerging droplet or bubble.
Abstract: This article describes the process of formation of droplets and bubbles in microfluidic T-junction geometries. At low capillary numbers break-up is not dominated by shear stresses: experimental results support the assertion that the dominant contribution to the dynamics of break-up arises from the pressure drop across the emerging droplet or bubble. This pressure drop results from the high resistance to flow of the continuous (carrier) fluid in the thin films that separate the droplet from the walls of the microchannel when the droplet fills almost the entire cross-section of the channel. A simple scaling relation, based on this assertion, predicts the size of droplets and bubbles produced in the T-junctions over a range of rates of flow of the two immiscible phases, the viscosity of the continuous phase, the interfacial tension, and the geometrical dimensions of the device.

2,071 citations

Journal ArticleDOI
TL;DR: A systematic and quantitative investigation of the influence of surfactants on the flow of fluids in microchannels containing bubbles using an indirect method to derive the pressure in the channel.
Abstract: This paper derives the difference in pressure between the beginning and the end of a rectangular microchannel through which a flowing liquid (water, with or without surfactant, and mixtures of water and glycerol) carries bubbles that contact all four walls of the channel. It uses an indirect method to derive the pressure in the channel. The pressure drop depends predominantly on the number of bubbles in the channel at both low and high concentrations of surfactant. At intermediate concentrations of surfactant, if the channel contains bubbles (of the same or different lengths), the total, aggregated length of the bubbles in the channel is the dominant contributor to the pressure drop. The difference between these two cases stems from increased flow of liquid through the “gutters”—the regions of the system bounded by the curved body of the bubble and the corners of the channel—in the presence of intermediate concentrations of surfactant. This paper presents a systematic and quantitative investigation of the influence of surfactants on the flow of fluids in microchannels containing bubbles. It derives the contributions to the overall pressure drop from three regions of the channel: (i) the slugs of liquid between the bubbles (and separated from the bubbles), in which liquid flows as though no bubbles were present; (ii) the gutters along the corners of the microchannels; and (iii) the curved caps at the ends of the bubble.

345 citations

Journal ArticleDOI
09 Feb 2007-Science
TL;DR: The encoding/decoding device is a functional microfluidic system that requires droplets to navigate a network in a precise manner without the use of valves, switches, or other means of external control.
Abstract: Droplets of one liquid suspended in a second, immiscible liquid move through a microfluidic device in which a channel splits into two branches that reconnect downstream. The droplets choose a path based on the number of droplets that occupy each branch. The interaction among droplets in the channels results in complex sequences of path selection. The linearity of the flow through the microchannels, however, ensures that the behavior of the system can be reversed. This reversibility makes it possible to encrypt and decrypt signals coded in the intervals between droplets. The encoding/decoding device is a functional microfluidic system that requires droplets to navigate a network in a precise manner without the use of valves, switches, or other means of external control.

228 citations

Journal ArticleDOI
TL;DR: This paper illustrates the use of the micromixer by incorporating it into an elementary, portable microfluidic system that includes sample introduction, sample filtration, and valving.
Abstract: This paper demonstrates a methodology for micromixing that is sufficiently simple that it can be used in portable microfluidic devices. It illustrates the use of the micromixer by incorporating it into an elementary, portable microfluidic system that includes sample introduction, sample filtration, and valving. This system has the following characteristics: (i) it is powered with a single hand-operated source of vacuum, (ii) it allows samples to be loaded easily by depositing them into prefabricated wells, (iii) the samples are filtered in situ to prevent clogging of the microchannels, (iv) the structure of the channels ensure mixing of the laminar streams by interaction with bubbles of gas introduced into the channels, (v) the device is prepared in a single-step soft-lithographic process, and (vi) the device can be prepared to be resistant to the adsorption of proteins, and can be used with or without surface-active agents.

156 citations


Cited by
More filters
28 Jul 2005
TL;DR: PfPMP1)与感染红细胞、树突状组胞以及胎盘的单个或多个受体作用,在黏附及免疫逃避中起关键的作�ly.
Abstract: 抗原变异可使得多种致病微生物易于逃避宿主免疫应答。表达在感染红细胞表面的恶性疟原虫红细胞表面蛋白1(PfPMP1)与感染红细胞、内皮细胞、树突状细胞以及胎盘的单个或多个受体作用,在黏附及免疫逃避中起关键的作用。每个单倍体基因组var基因家族编码约60种成员,通过启动转录不同的var基因变异体为抗原变异提供了分子基础。

18,940 citations

01 May 2005

2,648 citations

Journal ArticleDOI
TL;DR: Fundamental and applied research in chemistry and biology benefits from opportunities provided by droplet-based microfluidic systems, which enable the miniaturization of reactions by compartmentalizing reactions in droplets of femoliter to microliter volumes.
Abstract: Fundamental and applied research in chemistry and biology benefits from opportunities provided by droplet-based microfluidic systems. These systems enable the miniaturization of reactions by compartmentalizing reactions in droplets of femoliter to microliter volumes. Compartmentalization in droplets provides rapid mixing of reagents, control of the timing of reactions on timescales from milliseconds to months, control of interfacial properties, and the ability to synthesize and transport solid reagents and products. Droplet-based microfluidics can help to enhance and accelerate chemical and biochemical screening, protein crystallization, enzymatic kinetics, and assays. Moreover, the control provided by droplets in microfluidic devices can lead to new scientific methods and insights.

1,702 citations

Journal ArticleDOI
TL;DR: The aim of this review is to introduce and discuss the various developments within the field of magnetism and microfluidics.
Abstract: Magnetic forces are now being utilised in an amazing variety of microfluidic applications. Magnetohydrodynamic flow has been applied to the pumping of fluids through microchannels. Magnetic materials such as ferrofluids or magnetically doped PDMS have been used as valves. Magnetic microparticles have been employed for mixing of fluid streams. Magnetic particles have also been used as solid supports for bioreactions in microchannels. Trapping and transport of single cells are being investigated and recently, advances have been made towards the detection of magnetic material on-chip. The aim of this review is to introduce and discuss the various developments within the field of magnetism and microfluidics.

1,136 citations

Journal ArticleDOI
TL;DR: A droplet-based microfluidics protocol for high-throughput analysis and sorting of single cells, and a binding assay for detecting antibodies secreted from single mouse hybridoma cells is detailed.
Abstract: We present a droplet-based microfluidics protocol for high-throughput analysis and sorting of single cells. Compartmentalization of single cells in droplets enables the analysis of proteins released from or secreted by cells, thereby overcoming one of the major limitations of traditional flow cytometry and fluorescence-activated cell sorting. As an example of this approach, we detail a binding assay for detecting antibodies secreted from single mouse hybridoma cells. Secreted antibodies are detected after only 15 min by co-compartmentalizing single mouse hybridoma cells, a fluorescent probe and single beads coated with anti-mouse IgG antibodies in 50-pl droplets. The beads capture the secreted antibodies and, when the captured antibodies bind to the probe, the fluorescence becomes localized on the beads, generating a clearly distinguishable fluorescence signal that enables droplet sorting at ∼200 Hz as well as cell enrichment. The microfluidic system described is easily adapted for screening other intracellular, cell-surface or secreted proteins and for quantifying catalytic or regulatory activities. In order to screen ∼1 million cells, the microfluidic operations require 2-6 h; the entire process, including preparation of microfluidic devices and mammalian cells, requires 5-7 d.

1,136 citations