Michael J. Pugia

Bio: Michael J. Pugia is an academic researcher from Bayer Corporation. The author has contributed to research in topics: Dipstick & Reagent. The author has an hindex of 15, co-authored 31 publications receiving 722 citations.
Topics: Dipstick, Reagent, Proteinuria, Albuminuria, Albumin

Papers
More filters
01 Sep 1997
TL;DR: A new dip- and read dipstick is described that detects urine albumin at concentrations of 10 mg/l and above and urine creatinine in urine and finds agreement 84% of the time with the same ratio obtained from a quantitative immunochemical method for albumin and a rate-Jaffe method forCreatinine.
Abstract: We describe a new dip- and read dipstick that detects urine albumin at concentrations of 10 mg/l and above and urine creatinine at concentrations of 300 mg/l and above The albumin assay is based on a high-affinity, dye-binding technique while the creatinine assay is based on the peroxidase-like activity of copper creatinine complexes With these two-test dipsticks, urines from normal adults supplemented with albumin and creatinine were correctly identified to within +/- 15% of the expected value for both analytes; the between-day coefficients of variation ranged from 71% to 161% We tested 275 patients' unmodified urines by the Bayer and Boehringer Mannheim Micral-Test albumin dipsticks and for albumin with the Beckman Array on the same specimens We also analyzed 42 selected urines from the group of 275 for albumin by another quantitative immunochemical method and by electrophoresis plus a total protein method to estimate the albumin concentration The quantitative immunochemical methods appear to underestimate the urine albumin concentrations; in these 42 urines measured as negative, ie, or = 16 mg/l at an 80% rate At a cutoff of 20 mg/l, the rate increased to 87% We also determined the urinary albumin/creatinine ratios on the 275 patients using the Bayer two-pad dipstick and found agreement 84% of the time with the same ratio obtained from a quantitative immunochemical method for albumin and a rate-Jaffe method for creatinine; an albumin/creatinine ratio (mg/g) of 30 was used as the discrimination point Albumin stability studies performed on the Beckman Array patients with six fresh urines showed small but consistent decreases at -20 degrees C but not at 4 degrees C after one month of storage The albumin in contrived urines, as estimated by electrophoreses/total protein and by the dipsticks did not change at these storage conditions Boric acid at 1 g/l as a urine preservative had no effect on the measurement of albumin by any of the methods described here nor of the assay of creatinine Other urinary proteins present at abnormal excretion rates did not interfere with the Bayer albumin dipstick Abnormal concentrations of bilirubin, citrate, creatine, ascorbic acid, albumin, hemoglobin and myoglobin in urine did not interfere with the creatinine dipstick measurements The first four of the above did not affect the Bayer dipstick results for albumin

31 citations

Journal ArticleDOI
TL;DR: The albumin/creatinine ratio from the Bayer dipsticks gave better accuracy for albumin excretion than the albumin pads alone from either manufacturer.
Abstract: Three hospital sites evaluated the Bayer two-pad urine dipstick as a screening test for microalbuminuria One pad estimates albumin concentrations between 10 and 150 mg/L, and the second estimates creatinine values between 300 and 3,000 mg/L The Boehringer Mannheim (BMD) Micral dipstick was also compared and evaluated The accuracy of the dipsticks was judged by comparison with cuvet-based immunonephelometry for albumin and to standard rate-Jaffe methods for creatinine; these assays were well standardized and controlled and were assumed to give accurate values Precision of these methods and that of the dipsticks was determined by multiple assays of control materials Visual or instrument (Clinitek 50 or 100) evaluation of the Bayer or visual checks of the BMD albumin dipstick pad with patients' urines gave clinically acceptable accuracy The albumin/creatinine ratio from the Bayer dipsticks gave better accuracy for albumin excretion than the albumin pads alone from either manufacturer This ratio should permit making a good estimate of the 24-hr albumin excretion in a randomly collected urine

30 citations

Journal ArticleDOI
TL;DR: With the simultaneous measurement of creatinine and albumin in urine, the albumin/creatinine ratio can be determined effectively reducing or eliminating the occasional false-negative and false-positive result in those with dilute or concentrated urines, respectively.

28 citations

Journal ArticleDOI
TL;DR: A multisite evaluation of a new urine dipstick called Multistix PRO™ (Bayer, Elkhart, IN), which has reagent pads for the simultaneous assay of urinary albumin, protein, and creatinine found that dividing the dipsticks’ albumin or protein results by the creatInine concentration reduced the number of false‐positive album in or protein values observed in concentrated urines, and reduced theNumber of false negatives in dilute urines.
Abstract: The goal of our study was to perform a multisite evaluation of a new urine dipstick called Multistix PROtrade mark (Bayer, Elkhart, IN), which has reagent pads for the simultaneous assay of urinary albumin, protein, and creatinine. Patients' urine specimens were assayed at four sites with these dipsticks and with the familiar Bayer Multistix 10SG dipsticks for protein. The new dipstick pads for albumin are impregnated with bis (3',3"-diiodo-4',4"-dihydroxy-5',5"-dinitrophenyl)-3,4,5,6-tetrabromo-sulfonephthalein (DIDNTB) dye. These dipsticks also have a novel pad that estimates urinary creatinine using the peroxidase activity of the copper-creatinine complex. We determined the interlaboratory agreement of these dipsticks by comparing dipstick results to values obtained by quantitative analytical methods. We found that dividing the dipsticks' albumin or protein results by the creatinine concentration reduced the number of false-positive albumin or protein values observed in concentrated urines, and reduced the number of false negatives in dilute urines. The ratio of albumin to creatinine, or protein to creatinine gives a better measure of albumin or protein excretion. Compared to reading by eye, the dipstick results agreed better with the quantitative assays when they were read by a reflectometer (Bayer Clinitek).

26 citations

Patent
02 Nov 1995
TL;DR: In this paper, a method and test device for determining the presence of leukocytes, esterase or protease in a test sample are disclosed, which comprises an ester which is hydrolyzed in the presence with a diazonium salt to produce a detectable color change.
Abstract: A composition, method and test device for determining the presence of leukocytes, esterase or protease in a test sample are disclosed. The composition comprises an ester which is hydrolyzed in the presence of leukocyte, esterase, or protease to form a reaction product which couples with a diazonium salt to produce a detectable color change. The composition further comprises the salt of an alkaline earth metal which stabilizes the composition during manufacture and prevents the occurrence of false or background color change due to reactivity of the diazonium salt in the absence of leukocyte, esterase or protease.

21 citations


Cited by
More filters
Journal Article
TL;DR: In the early 1990s, the National Kidney Foundation (K/DOQI) developed a set of clinical practice guidelines to define chronic kidney disease and to classify stages in the progression of kidney disease.

10,265 citations

Journal ArticleDOI
TL;DR: This communication describes a simple method for patterning paper to create well-defined, millimeter-sized channels, comprising hydrophilic paper bounded by hydrophobic polymer, that will become the basis for low-cost, portable, and technically simple multiplexed bioassays.
Abstract: This communication describes a simple method for patterning paper to create well-defined, millimeter-sized channels, comprising hydrophilic paper bounded by hydrophobic polymer. We believe that this type of patterned paper will become the basis for low-cost, portable, and technically simple multiplexed bioassays. We demonstrate this capability by the simultaneous detection of glucose and protein in 5 μL of urine. The assay system is small, disposable, easy to use (and carry), and requires no external equipment, reagents, or power sources. We believe this kind of system is attractive for uses in less-industrialized countries, in the field, or as an inexpensive alternative to more advanced technologies already used in clinical settings.[1-4] The analysis of biological fluids is necessary for monitoring the health of populations,[2] but these measurements are difficult to implement in remote regions such as those found in less-industrialized countries, in emergency situations, or in home health-care settings.[3] Conventional laboratory instruments provide quantitative measurements of biological samples, but they are unsuitable for these situations since they are large, expensive, and require trained personnel and considerable volumes of biological samples.[2] Other bioassay platforms provide alternatives to more expensive instruments,[5-7] but the need remains for a platform that uses small volumes of sample and that is sufficiently inexpensive to be used widely for measuring samples from large populations. We believe that paper may serve as a particularly convenient platform for running bioassays in the remote situations locations. As a prototype for a mthod we believe to be particularly promosing, we patterned photoresist onto chromatography paper to form defined areas of hydrophilic paper separated by hydrophobic lines or “walls”; these patterns provide spatial control of biological fluids and enable fluid transport, without pumping, due to capillary action in the millimeter-sized channels produced. This method for patterning paper makes it possible to run multiple diagnostic assays on one strip of paper, while still using only small volumes of a single sample. In a fully developed technology, patterned photoresist would be replaced by an appropriate printing technology, but patterning paper with photoresist is: i) convenient for prototyping these devices, and ii) a useful new micropatterning technology in its own right. We patterned chromatography paper with SU-8 2010 photoresist as shown in Figure 1a and as described below: we soaked a 7.5-cm diameter piece of chromatography paper in 2 mL of SU-8 2010 for 30 s, spun it at 2000 rpm for 30 s, and then baked it at 95 °C for 5 min to remove the cyclopentanone in the SU-8 formula. We then exposed the photoresist and paper to 405 nm UV light (50 mW/cm2) for 10 s through a photo-mask (CAD/Art Services, Inc.) that was aligned using a mask aligner (OL-2 Mask Aligner, AB-M, Inc). After exposure, we baked the paper a second time at 95 °C for 5 min to cross-link the exposed portions of the resist. The unpolymerized photoresist was removed by soaking the paper in propylene glycol monomethyl ether acetate (PGMEA) (5 min), and by washing the pattern with propan-2-ol (3 × 10 mL). The paper was more hydrophobic after it was patterned, presumably due to residual resist bound to the paper, so we exposed the entire surface to an oxygen plasma for 10 s at 600 millitorr (SPI Plasma-Prep II, Structure Probe, Inc) to increase the hydrophilicity of the paper (Figures 2a and 2b). Figure 1 Chromatography paper patterned with photoresist. The darker lines are cured photoresist; the lighter areas are unexposed paper. (a) Patterned paper after absorbing 5 μL of Waterman red ink by capillary action. The central channel absorbs the sample ... Figure 2 Assays contaminated with (a) dirt, (b) plant pollen, and (c) graphite powder. The pictures were taken before and after running an artificial urine solution that contained 550 mM glucose and 75 μM BSA. The particulates do not move up the channels ... The patterned paper can be derivatized for biological assays by adding appropriate reagents to the test areas (Figures 1b and ​and2b).2b). In this communication, we demonstrate the method by detecting glucose and protein,[8] but the surface should be suitable for measuring many other analytes as well.[7] The glucose assay is based on the enzymatic oxidation of iodide to iodine,[9] where a color change from clear to brown is associated with the presence of glucose.[10] The protein assay is based on the color change of tetrabromophenol blue (TBPB) when it ionizes and binds to proteins;[11] a positive result in this case is indicated by a color change from yellow to blue. For the glucose assay, we spotted 0.3 μL of a 0.6 M solution of potassium iodide, followed by 0.3 μL of a 1:5 horseradish peroxidase/glucose oxidase solution (15 units of protein per mL of solution). For the protein assay, we spotted 0.3 μL of a 250-mM citrate buffer (pH 1.8) in a well separate from the glucose assay, and then layered 0.3 μL of a 3.3 mM solution of tetrabromophenol blue (TBPB) in 95% ethanol over the citrate buffer. The spotted reagents were allowed to air dry at room temperature. This pre-loaded paper gave consistent results for the protein assay regardless of storage temperature and time (when stored for 15 d both at 0 °C and at 23 °C, wrapped in aluminum foil). The glucose assay was sensitive to storage conditions, and showed decreased signal for assays run 24 h after spotting the reagents (when stored at 23 °C); when stored at 0 °C, however, the glucose assay was as sensitive after day 15 as it was on day 1. We measured artificial samples of glucose and protein in clinically relevant ranges (2.5-50 mM for glucose and 0.38-7.5 μM for bovine serum albumin (BSA))[12, 13] by dipping the bottom of each test strip in 5 μL of a pre-made test solution (Figure 2d). The fluid filled the entire pattern within ca. one minute, but the assays required 10-11 min for the paper to dry and for the color to fully develop.[14] In all cases, we observed color changes corresponding roughly in intensity to the amount of glucose and protein in the test samples, where the lowest concentrations define the lower limits to which these assays can be used (Figure 2e). For comparison, commercially-available dipsticks detect glucose at concentrations as low as 5 mM[7, 9] and protein as low as 0.75 μM;[6, 15] these limits indicate that these paper-based assays are comparable in sensitivity to commercial dipstick assays. Our assay format also allows for the measurement of multiple analytes. This paper-based assay is suitable for measuring multiple samples in parallel and in a relatively short period of time. For example, in one trial, one researcher was able to run 20 different samples (all with 550 mM glucose and 75 μM BSA) within 7.5 min (followed by another 10.5 min for the color to fully develop). An 18-min assay of this type—one capable of measuring two analytes in 20 different sample—may be efficient enough to use in high-throughput screens of larger sample pools. In the field, samples will not be measured under sterile conditions, and dust and dirt may contaminate the assays. The combination of paper and capillary action provides a mechanism for separating particulates from a biological fluid. As a demonstration, we purposely contaminated the artificial urine samples with quantities of dirt, plant pollen, and graphite powder at levels higher than we might expect to see in the samples in the field. These particulates do not move up the channels under the action of capillary wicking, and do not interfere with the assay (Figure 3). Paper strips have been used in biomedical assays for decades because they offer an inexpensive platform for colorimetric chemical testing.[1] Patterned paper has characteristics that lead to miniaturized assays that run by capillary action (e.g., without external pumping), with small volumes of fluids. These methods suggest a path for the development of simple, inexpensive, and portable diagnostic assays that may be useful in remote settings, and in particular, in less-industrialized countries where simple assays are becoming increasingly important for detecting disease and monitoring health,[16, 17], for environmental monitoring, in veterinary and agricultural practice and for other applications.

2,580 citations

Journal ArticleDOI
TL;DR: This review summarizes emerging efforts in combating against infectious diseases, particularly using antimicrobial NPs and antibiotics delivery systems as new tools to tackle the current challenges in treating infectious diseases.

1,493 citations

Journal ArticleDOI
TL;DR: A prototype system for quantifying bioassays and for exchanging the results of the assays digitally with physicians located off-site offers new opportunities for inexpensive monitoring of health, especially in situations that require physicians to travel to patients to obtain diagnostic information that might be obtained more effectively by less valuable personnel.
Abstract: This article describes a prototype system for quantifying bioassays and for exchanging the results of the assays digitally with physicians located off-site. The system uses paper-based microfluidic devices for running multiple assays simultaneously, camera phones or portable scanners for digitizing the intensity of color associated with each colorimetric assay, and established communications infrastructure for transferring the digital information from the assay site to an off-site laboratory for analysis by a trained medical professional; the diagnosis then can be returned directly to the healthcare provider in the field. The microfluidic devices were fabricated in paper using photolithography and were functionalized with reagents for colorimetric assays. The results of the assays were quantified by comparing the intensities of the color developed in each assay with those of calibration curves. An example of this system quantified clinically relevant concentrations of glucose and protein in artificial uri...

1,393 citations

Journal ArticleDOI
TL;DR: A method for fabricating 3D microfluidic devices by stacking layers of patterned paper and double-sided adhesive tape to carry out a range of new analytical protocols simply and inexpensively without external pumps is described.
Abstract: This article describes a method for fabricating 3D microfluidic devices by stacking layers of patterned paper and double-sided adhesive tape. Paper-based 3D microfluidic devices have capabilities in microfluidics that are difficult to achieve using conventional open-channel microsystems made from glass or polymers. In particular, 3D paper-based devices wick fluids and distribute microliter volumes of samples from single inlet points into arrays of detection zones (with numbers up to thousands). This capability makes it possible to carry out a range of new analytical protocols simply and inexpensively (all on a piece of paper) without external pumps. We demonstrate a prototype 3D device that tests 4 different samples for up to 4 different analytes and displays the results of the assays in a side-by-side configuration for easy comparison. Three-dimensional paper-based microfluidic devices are especially appropriate for use in distributed healthcare in the developing world and in environmental monitoring and water analysis.

1,204 citations