scispace - formally typeset
Search or ask a question
Author

Michael Pircher

Other affiliations: Canon Inc., University of Vienna
Bio: Michael Pircher is an academic researcher from Medical University of Vienna. The author has contributed to research in topics: Optical coherence tomography & Birefringence. The author has an hindex of 48, co-authored 250 publications receiving 7740 citations. Previous affiliations of Michael Pircher include Canon Inc. & University of Vienna.


Papers
More filters
Journal ArticleDOI
TL;DR: An improved method of polarization sensitive optical coherence tomography is presented that enables measurement and imaging of backscattered intensity, birefringence, and fast optic axis orientation simultaneously with only one single A-scan per transverse measurement location.
Abstract: We present an improved method of polarization sensitive optical coherence tomography that enables measurement and imaging of backscattered intensity, birefringence, and fast optic axis orientation simultaneously with only one single A-scan per transverse measurement location. While intensity and birefringence data are obtained in a conventional way, the optic axis orientation is determined from the phase difference recorded in two orthogonal polarization channels. We report on accuracy and precision of the method by measuring birefringence and optic axis orientation of well defined polarization states in a technical object and present maps of birefringence and, what we believe for the first time, of optic axis orientation in biological tissue.

491 citations

Journal ArticleDOI
TL;DR: The frequency compounding method based on incoherent summation of the magnitudes of two independent interferometric signals, which were recorded at two different center wavelengths simultaneously, results in an increased contrast and improved image quality without loss of resolution.
Abstract: We are investigating the possibility of a frequency compounding method for speckle reduction in optical coherence tomography. The method is based on incoherent summation of the magnitudes of two independent interferometric signals, which were recorded at two different center wavelengths simultaneously. We derive the corresponding statistics and compare the theoretical results with measurements obtained in a uniformly scattering sample. Finally we demonstrate our method by comparing images of human skin recorded in vivo with and without frequency compounding. The compounding method results in an increased contrast and improved image quality without loss of resolution.

349 citations

Journal ArticleDOI
TL;DR: A new method for identifying and segmenting the retinal pigment epithelium (RPE) in polarization sensitive optical coherence tomography (PS-OCT) images of the human retina using an intrinsic tissue property of the RPE: its depolarizing, or polarization scrambling effect on backscattered light.
Abstract: We present a new method for identifying and segmenting the retinal pigment epithelium (RPE) in polarization sensitive optical coherence tomography (PS-OCT) images of the human retina. Contrary to previous, intensity based segmentation algorithms, our method uses an intrinsic tissue property of the RPE: its depolarizing, or polarization scrambling effect on backscattered light. Two different segmentation algorithms are presented and discussed: a simpler algorithm based on retardation data, and a more sophisticated algorithm based on local variations of the polarization state calculated from averaged Stokes vector elements. By using a state of the art spectral domain PS-OCT instrument, we demonstrate the method in healthy and diseased eyes.

290 citations

Journal ArticleDOI
TL;DR: The system uses two spectrometers, one for each polarization channel, that operate in parallel at 20000 A-lines/s each and provides reflectivity, retardation, and cumulative optic axis orientation simultaneously.
Abstract: We developed a high-speed polarization sensitive optical coherence tomography (PS-OCT) system for retinal imaging based on spectral domain OCT. The system uses two spectrometers, one for each polarization channel, that operate in parallel at 20000 A-lines/s each. It provides reflectivity, retardation, and cumulative optic axis orientation simultaneously. We present our instrument and discuss the requirements for the alignment of the two spectrometers specific for our setup. We show 2D spectral domain PS-OCT images and – to the best of our knowledge – the first 3D spectral domain PS-OCT data sets in form of fly-through movies and volume rendered data sets recorded in human retina in vivo.

278 citations

Journal ArticleDOI
TL;DR: A variety of different applications of this technique are presented in ocular imaging that are ranging from the anterior to the posterior eye segment and the benefits of the method for imaging different diseases as, e.g., age related macula degeneration or glaucoma is demonstrated.

261 citations


Cited by
More filters
01 Jan 2016
TL;DR: In this paper, the authors present the principles of optics electromagnetic theory of propagation interference and diffraction of light, which can be used to find a good book with a cup of coffee in the afternoon, instead of facing with some infectious bugs inside their computer.
Abstract: Thank you for reading principles of optics electromagnetic theory of propagation interference and diffraction of light. As you may know, people have search hundreds times for their favorite novels like this principles of optics electromagnetic theory of propagation interference and diffraction of light, but end up in harmful downloads. Rather than enjoying a good book with a cup of coffee in the afternoon, instead they are facing with some infectious bugs inside their computer.

2,213 citations

Journal ArticleDOI
TL;DR: OCT as discussed by the authors synthesises cross-sectional images from a series of laterally adjacent depth-scans, which can be used to assess tissue and cell function and morphology in situ.
Abstract: There have been three basic approaches to optical tomography since the early 1980s: diffraction tomography, diffuse optical tomography and optical coherence tomography (OCT). Optical techniques are of particular importance in the medical field, because these techniques promise to be safe and cheap and, in addition, offer a therapeutic potential. Advances in OCT technology have made it possible to apply OCT in a wide variety of applications but medical applications are still dominating. Specific advantages of OCT are its high depth and transversal resolution, the fact, that its depth resolution is decoupled from transverse resolution, high probing depth in scattering media, contact-free and non-invasive operation, and the possibility to create various function dependent image contrasting methods. This report presents the principles of OCT and the state of important OCT applications. OCT synthesises cross-sectional images from a series of laterally adjacent depth-scans. At present OCT is used in three different fields of optical imaging, in macroscopic imaging of structures which can be seen by the naked eye or using weak magnifications, in microscopic imaging using magnifications up to the classical limit of microscopic resolution and in endoscopic imaging, using low and medium magnification. First, OCT techniques, like the reflectometry technique and the dual beam technique were based on time-domain low coherence interferometry depth-scans. Later, Fourier-domain techniques have been developed and led to new imaging schemes. Recently developed parallel OCT schemes eliminate the need for lateral scanning and, therefore, dramatically increase the imaging rate. These schemes use CCD cameras and CMOS detector arrays as photodetectors. Video-rate three-dimensional OCT pictures have been obtained. Modifying interference microscopy techniques has led to high-resolution optical coherence microscopy that achieved sub-micrometre resolution. This report is concluded with a short presentation of important OCT applications. Ophthalmology is, due to the transparent ocular structures, still the main field of OCT application. The first commercial instrument too has been introduced for ophthalmic diagnostics (Carl Zeiss Meditec AG). Advances in using near-infrared light, however, opened the path for OCT imaging in strongly scattering tissues. Today, optical in vivo biopsy is one of the most challenging fields of OCT application. High resolution, high penetration depth, and its potential for functional imaging attribute to OCT an optical biopsy quality, which can be used to assess tissue and cell function and morphology in situ. OCT can already clarify the relevant architectural tissue morphology. For many diseases, however, including cancer in its early stages, higher resolution is necessary. New broad-bandwidth light sources, like photonic crystal fibres and superfluorescent fibre sources, and new contrasting techniques, give access to new sample properties and unmatched sensitivity and resolution.

1,914 citations

Journal Article
TL;DR: In this article, optical coherence tomography is used for high-resolution, noninvasive imaging of the human retina, including the macula and optic nerve head in normal human subjects.
Abstract: Objective: To demonstrate optical coherence tomography for high-resolution, noninvasive imaging of the human retina. Optical coherence tomography is a new imaging technique analogous to ultrasound B scan that can provide cross-sectional images of the retina with micrometer-scale resolution. Design: Survey optical coherence tomographic examination of the retina, including the macula and optic nerve head in normal human subjects. Settings Research laboratory. Participants: Convenience sample of normal human subjects. Main Outcome Measures: Correlation of optical coherence retinal tomographs with known normal retinal anatomy. Results: Optical coherence tomographs can discriminate the cross-sectional morphologic features of the fovea and optic disc, the layered structure of the retina, and normal anatomic variations in retinal and retinal nerve fiber layer thicknesses with 10- μm depth resolution. Conclusion: Optical coherence tomography is a potentially useful technique for high depth resolution, cross-sectional examination of the fundus.

1,409 citations

Journal Article
J. Walkup1
TL;DR: Development of this more comprehensive model of the behavior of light draws upon the use of tools traditionally available to the electrical engineer, such as linear system theory and the theory of stochastic processes.
Abstract: Course Description This is an advanced course in which we explore the field of Statistical Optics. Topics covered include such subjects as the statistical properties of natural (thermal) and laser light, spatial and temporal coherence, effects of partial coherence on optical imaging instruments, effects on imaging due to randomly inhomogeneous media, and a statistical treatment of the detection of light. Development of this more comprehensive model of the behavior of light draws upon the use of tools traditionally available to the electrical engineer, such as linear system theory and the theory of stochastic processes.

1,364 citations

Journal Article
TL;DR: In this article, optical coherence tomography was adapted to allow high-speed visualization of tissue in a living animal with a catheter-endoscope 1 millimeter in diameter, which was used to obtain cross-sectional images of the rabbit gastrointestinal and respiratory tracts at 10-micrometer resolution.
Abstract: Current medical imaging technologies allow visualization of tissue anatomy in the human body at resolutions ranging from 100 micrometers to 1 millimeter. These technologies are generally not sensitive enough to detect early-stage tissue abnormalities associated with diseases such as cancer and atherosclerosis, which require micrometer-scale resolution. Here, optical coherence tomography was adapted to allow high-speed visualization of tissue in a living animal with a catheter-endoscope 1 millimeter in diameter. This method, referred to as "optical biopsy," was used to obtain cross-sectional images of the rabbit gastrointestinal and respiratory tracts at 10-micrometer resolution.

1,285 citations