scispace - formally typeset
Search or ask a question
Author

Michael R. Corson

Bio: Michael R. Corson is an academic researcher from United States Naval Research Laboratory. The author has contributed to research in topics: Hyperspectral imaging & Retroreflector. The author has an hindex of 8, co-authored 15 publications receiving 339 citations. Previous affiliations of Michael R. Corson include United States Department of the Navy.

Papers
More filters
Journal ArticleDOI
TL;DR: The HICO is an innovative prototype sensor that builds on extensive experience with airborne sensors and makes extensive use of commercial off-the-shelf components to build a space sensor at a small fraction of the usual cost and time.
Abstract: The Hyperspectral Imager for the Coastal Ocean (HICO) is the first spaceborne hyperspectral sensor designed specifically for the coastal ocean and estuarial, riverine, or other shallow-water areas The HICO generates hyperspectral images, primarily over the 400-900 nm spectral range, with a ground sample distance of ≈90 m (at nadir) and a high signal-to-noise ratio The HICO is now operating on the International Space Station (ISS) Its cross-track and along-track fields of view are 42 km (at nadir) and 192 km, respectively, for a total scene area of 8000 km(2) The HICO is an innovative prototype sensor that builds on extensive experience with airborne sensors and makes extensive use of commercial off-the-shelf components to build a space sensor at a small fraction of the usual cost and time Here we describe the instrument's design and characterization and present early images from the ISS

158 citations

Journal ArticleDOI
TL;DR: The goal of this work is to elucidate the effect of signal-to-noise ratio (SNR) on the accuracy of retrieved constituent concentrations and to reduce estimation uncertainties by 10% or more.
Abstract: Errors in the estimated constituent concentrations in optically complex waters due solely to sensor noise in a spaceborne hyperspectral sensor can be as high as 80%. The goal of this work is to elucidate the effect of signal-to-noise ratio (SNR) on the accuracy of retrieved constituent concentrations. Large variations in the magnitude and spectral shape of the reflectances from coastal waters complicate the impact of SNR on the accuracy of estimation. Due to the low reflectance of water, the actual SNR encountered for a water target is usually quite lower than the prescribed SNR. The low SNR can be a significant source of error in the estimated constituent concentrations. Simulated and measured at-surface reflectances were used in this study. A radiative transfer code, Tafkaa, was used to propagate the at-surface reflectances up and down through the atmosphere. A sensor noise model based on that of the spaceborne hyperspectral sensor HICO was applied to the at-sensor radiances. Concentrations of chlorophyll-a, colored dissolved organic matter, and total suspended solids were estimated using an optimized error minimization approach and a few semi-analytical algorithms. Improving the SNR by reasonably modifying the sensor design can reduce estimation uncertainties by 10% or more.

60 citations

Patent
28 Nov 2007
TL;DR: In this paper, a spectroscopic detector is used to identify the presence of a first substance in a presence of another substance, which includes a laser for illuminating the substances at a plurality of wavelengths to induce the emission of radiation characteristic of the substance; a spectrometer for measuring the emitted radiation to obtain a plurality spectral measurement data; and a processor for processing the data.
Abstract: A spectroscopic detector for identifying the presence of a first substance in the presence of another substance includes a laser for illuminating the substances at a plurality of wavelengths to induce the emission of radiation characteristic of the substance; a spectrometer for measuring the emitted radiation to obtain a plurality of spectral measurement data; and a processor for processing the data. An algorithm combines the data into a composite spectrum and a parameter characteristic of the first substance is identified while information in the composite spectrum contributed by emission of radiation from the other substance is removed to identify the presence of the first substance and obtain a characteristic spectral signature of the first substance. The signature is compared to signatures in a spectral library database, wherein at least some of the library signatures have spectral characteristics differentiated from each other by identifiable spectral characteristics caused by environmental factors.

27 citations

Journal ArticleDOI
TL;DR: Improvements to the present vicarious calibration techniques are possible as the authors gain more in-depth understanding of the HICO laboratory calibration data and the ISS HICO data in the future.
Abstract: The Hyperspectral Imager for the Coastal Ocean (HICO) presently onboard the International Space Station (ISS) is an imaging spectrometer designed for remote sensing of coastal waters. The instrument is not equipped with any onboard spectral and radiometric calibration devices. Here we describe vicarious calibration techniques that have been used in converting the HICO raw digital numbers to calibrated radiances. The spectral calibration is based on matching atmospheric water vapor and oxygen absorption bands and extraterrestrial solar lines. The radiometric calibration is based on comparisons between HICO and the EOS/MODIS data measured over homogeneous desert areas and on spectral reflectance properties of coral reefs and water clouds. Improvements to the present vicarious calibration techniques are possible as we gain more in-depth understanding of the HICO laboratory calibration data and the ISS HICO data in the future.

27 citations

Journal ArticleDOI
13 Mar 2015-Sensors
TL;DR: The results emphasize the effect of sensor noise on water quality parameter retrieval and the need for sensors with high Signal-to-Noise Ratio for quantitative remote sensing of optically complex waters.
Abstract: Using simulated data, we investigated the effect of noise in a spaceborne hyperspectral sensor on the accuracy of the atmospheric correction of at-sensor radiances and the consequent uncertainties in retrieved water quality parameters. Specifically, we investigated the improvement expected as the F-number of the sensor is changed from 3.5, which is the smallest among existing operational spaceborne hyperspectral sensors, to 1.0, which is foreseeable in the near future. With the change in F-number, the uncertainties in the atmospherically corrected reflectance decreased by more than 90% across the visible-near-infrared spectrum, the number of pixels with negative reflectance (caused by over-correction) decreased to almost one-third, and the uncertainties in the retrieved water quality parameters decreased by more than 50% and up to 92%. The analysis was based on the sensor model of the Hyperspectral Imager for the Coastal Ocean (HICO) but using a 30-m spatial resolution instead of HICO’s 96 m. Atmospheric correction was performed using Tafkaa. Water quality parameters were retrieved using a numerical method and a semi-analytical algorithm. The results emphasize the effect of sensor noise on water quality parameter retrieval and the need for sensors with high Signal-to-Noise Ratio for quantitative remote sensing of optically complex waters.

24 citations


Cited by
More filters
Journal ArticleDOI
16 Aug 2016-Sensors
TL;DR: The commonly used approaches and sensors employed in evaluating and quantifying the eleven water quality parameters, including chlorophyll-a (chl-a), colored dissolved organic matters (CDOM), Secchi disk depth (SDD), turbidity, total suspended sediments (TSS), water temperature (WT), total phosphorus (TP), sea surface salinity (SSS), dissolved oxygen (DO), biochemical oxygen demand (BOD) and chemical oxygendemand (COD).
Abstract: Remotely sensed data can reinforce the abilities of water resources researchers and decision makers to monitor waterbodies more effectively. Remote sensing techniques have been widely used to measure the qualitative parameters of waterbodies (i.e., suspended sediments, colored dissolved organic matter (CDOM), chlorophyll-a, and pollutants). A large number of different sensors on board various satellites and other platforms, such as airplanes, are currently used to measure the amount of radiation at different wavelengths reflected from the water’s surface. In this review paper, various properties (spectral, spatial and temporal, etc.) of the more commonly employed spaceborne and airborne sensors are tabulated to be used as a sensor selection guide. Furthermore, this paper investigates the commonly used approaches and sensors employed in evaluating and quantifying the eleven water quality parameters. The parameters include: chlorophyll-a (chl-a), colored dissolved organic matters (CDOM), Secchi disk depth (SDD), turbidity, total suspended sediments (TSS), water temperature (WT), total phosphorus (TP), sea surface salinity (SSS), dissolved oxygen (DO), biochemical oxygen demand (BOD) and chemical oxygen demand (COD).

554 citations

Journal ArticleDOI
TL;DR: An overview of the main characteristics and current status of the EnMAP mission is provided, which will contribute to the development and exploitation of spaceborne imaging spectroscopy applications by making high-quality data freely available to scientific users worldwide.
Abstract: Imaging spectroscopy, also known as hyperspectral remote sensing, is based on the characterization of Earth surface materials and processes through spectrally-resolved measurements of the light interacting with matter. The potential of imaging spectroscopy for Earth remote sensing has been demonstrated since the 1980s. However, most of the developments and applications in imaging spectroscopy have largely relied on airborne spectrometers, as the amount and quality of space-based imaging spectroscopy data remain relatively low to date. The upcoming Environmental Mapping and Analysis Program (EnMAP) German imaging spectroscopy mission is intended to fill this gap. An overview of the main characteristics and current status of the mission is provided in this contribution. The core payload of EnMAP consists of a dual-spectrometer instrument measuring in the optical spectral range between 420 and 2450 nm with a spectral sampling distance varying between 5 and 12 nm and a reference signal-to-noise ratio of 400:1 in the visible and near-infrared and 180:1 in the shortwave-infrared parts of the spectrum. EnMAP images will cover a 30 km-wide area in the across-track direction with a ground sampling distance of 30 m. An across-track tilted observation capability will enable a target revisit time of up to four days at the Equator and better at high latitudes. EnMAP will contribute to the development and exploitation of spaceborne imaging spectroscopy applications by making high-quality data freely available to scientific users worldwide.

512 citations

Journal ArticleDOI
TL;DR: An overview of the state of the art in atmospheric correction algorithms is provided, recent advances are highlighted and the possible potential for hyperspectral data to address the current challenges is discussed.
Abstract: Accurate correction of the corrupting effects of the atmosphere and the water’s surface are essential in order to obtain the optical, biological and biogeochemical properties of the water from satellite-based multi- and hyper-spectral sensors. The major challenges now for atmospheric correction are the conditions of turbid coastal and inland waters and areas in which there are strongly-absorbing aerosols. Here, we outline how these issues can be addressed, with a focus on the potential of new sensor technologies and the opportunities for the development of novel algorithms and aerosol models. We review hardware developments, which will provide qualitative and quantitative increases in spectral, spatial, radiometric and temporal data of the Earth, as well as measurements from other sources, such as the Aerosol Robotic Network for Ocean Color (AERONET-OC) stations, bio-optical sensors on Argo (Bio–Argo) floats and polarimeters. We provide an overview of the state of the art in atmospheric correction algorithms, highlight recent advances and discuss the possible potential for hyperspectral data to address the current challenges.

490 citations

Journal ArticleDOI
TL;DR: In this paper, a multispectral expert system used a neural network approach to provide Rapid Response thickness class maps using a spectral library approach based on the shape and depth of near infrared spectral absorption features.

432 citations