Michael R. Neuman

Other affiliations: Rigshospitalet, University of Memphis, Université de Montréal  ...read more
Bio: Michael R. Neuman is an academic researcher from Michigan Technological University. The author has contributed to research in topics: Sudden infant death syndrome & Heart rate. The author has an hindex of 32, co-authored 147 publications receiving 3590 citations. Previous affiliations of Michael R. Neuman include Rigshospitalet & University of Memphis.


Papers
More filters
Journal ArticleDOI
02 May 2001-JAMA
TL;DR: Test the hypothesis that preterm infants, siblings of infants who died of SIDS, and infants who have experienced an idiopathic, apparent life-threatening event have a greater risk of cardiorespiratory events than healthy term infants.
Abstract: ContextHome monitors designed to identify cardiorespiratory events are frequently used in infants at increased risk for sudden infant death syndrome (SIDS), but the efficacy of such devices for this use is unproven.ObjectiveTo test the hypothesis that preterm infants, siblings of infants who died of SIDS, and infants who have experienced an idiopathic, apparent life-threatening event have a greater risk of cardiorespiratory events than healthy term infants.DesignLongitudinal cohort study conducted from May 1994 through February 1998.SettingFive metropolitan medical centers in the United States.ParticipantsA total of 1079 infants (classified as healthy term infants and 6 groups of those at risk for SIDS) who, during the first 6 months after birth, were observed with home cardiorespiratory monitors using respiratory inductance plethysmography to detect apnea and obstructed breathing.Main Outcome MeasuresOccurrence of cardiorespiratory events that exceeded predefined conventional and extreme thresholds as recorded by the monitors.ResultsDuring 718 358 hours of home monitoring, 6993 events exceeding conventional alarm thresholds occurred in 445 infants (41%). Of these, 653 were extreme events in 116 infants (10%), and of those events with apnea, 70% included at least 3 obstructed breaths. The frequency of at least 1 extreme event was similar in term infants in all groups, but preterm infants were at increased risk of extreme events until 43 weeks' postconceptional age.ConclusionsIn this study, conventional events are quite common, even in healthy term infants. Extreme events were common only in preterm infants, and their timing suggests that they are not likely to be immediate precursors to SIDS. The high frequency of obstructed breathing in study participants would likely preclude detection of many events by conventional techniques. These data should be important for designing future monitors and determining if an infant is likely to be at risk for a cardiorespiratory event.

330 citations

Journal ArticleDOI
TL;DR: The preliminary in vivo experiments, to monitor H + and K + ionic distribution in the beating pig heart, help to determine the unique ionic conduction responsible for ventricullar fibrillation in the setting of acute regional myocardial ischemia.
Abstract: Thick-film H + - and K + -selective sensor arrays based on solvent polymeric neutral carrier membranes are described. The sensor array design and construction allow inexpensive and mass production of disposable miniaturized probes useful in the biomedical field, especially for cardiovascular research and monitoring. They are also suitable for use as multisensor electrochemical detectors within modern flow injection analysis instrumentation. The carriers used for membrane preparation are H + -selective ETH 5294 chromoionophore and the well-known K + -selective ionophore, valinomycin. The preliminary in vivo experiments, to monitor H + and K + ionic distribution in the beating pig heart, help to determine the unique ionic conduction responsible for ventricullar fibrillation in the setting of acute regional myocardial ischemia

167 citations

Journal ArticleDOI
TL;DR: The state of the art of energy scavenging technologies for powering sensors and instrumentation of physiological variables, the different transduction mechanisms, recent developments and challenges faced are reviewed and discussed.
Abstract: Energy scavenging has increasingly become an interesting option for powering electronic devices because of the almost infinite lifetime and the non-dependence on fuels for energy generation. Moreover, the rise of wireless technologies promises new applications in medical monitoring systems, but these still face limitations due to battery lifetime and size. A trade-off of these two factors has typically governed the size, useful life and capabilities of an autonomous system. Energy generation from sources such as motion, light and temperature gradients has been established as commercially viable alternatives to batteries for human-powered flashlights, solar calculators, radio receivers and thermal-powered wristwatches, among others. Research on energy harvesting from human activities has also addressed the feasibility of powering wearable or implantable systems. Biomedical sensors can take advantage of human-based activities as the energy source for energy scavengers. This review describes the state of the art of energy scavenging technologies for powering sensors and instrumentation of physiological variables. After a short description of the human power and the energy generation limits, the different transduction mechanisms, recent developments and challenges faced are reviewed and discussed.

160 citations

Journal ArticleDOI
TL;DR: High efficiency is suggested of the proposed methodology in separation of swallowing sounds from artifacts that originate from respiration, intrinsic speech, head movements, food ingestion, and ambient noise, suggesting that the methodology is suitable for obese individuals.
Abstract: Our understanding of etiology of obesity and overweight is incomplete due to lack of objective and accurate methods for monitoring of ingestive behavior (MIB) in the free-living population. Our research has shown that frequency of swallowing may serve as a predictor for detecting food intake, differentiating liquids and solids, and estimating ingested mass. This paper proposes and compares two methods of acoustical swallowing detection from sounds contaminated by motion artifacts, speech, and external noise. Methods based on mel-scale Fourier spectrum, wavelet packets, and support vector machines are studied considering the effects of epoch size, level of decomposition, and lagging on classification accuracy. The methodology was tested on a large dataset (64.5 h with a total of 9966 swallows) collected from 20 human subjects with various degrees of adiposity. Average weighted epoch-recognition accuracy for intravisit individual models was 96.8%, which resulted in 84.7% average weighted accuracy in detection of swallowing events. These results suggest high efficiency of the proposed methodology in separation of swallowing sounds from artifacts that originate from respiration, intrinsic speech, head movements, food ingestion, and ambient noise. The recognition accuracy was not related to body mass index, suggesting that the methodology is suitable for obese individuals.

158 citations

Journal ArticleDOI
TL;DR: A methodology of studying of ingestive behavior by non-invasive monitoring of swallowing (deglutition) and chewing (mastication) has been developed and a protocol is developed for manual scoring of chewing and swallowing for use as a gold standard.
Abstract: A methodology of studying of ingestive behavior by non-invasive monitoring of swallowing (deglutition) and chewing (mastication) has been developed. The target application for the developed methodology is to study the behavioral patterns of food consumption and producing volumetric and weight estimates of energy intake. Monitoring is non-invasive based on detecting swallowing by a sound sensor located over laryngopharynx or by a bone-conduction microphone and detecting chewing through a below-the-ear strain sensor. Proposed sensors may be implemented in a wearable monitoring device, thus enabling monitoring of ingestive behavior in free-living individuals. In this paper, the goals in the development of this methodology are two-fold. First, a system comprising sensors, related hardware and software for multi-modal data capture is designed for data collection in a controlled environment. Second, a protocol is developed for manual scoring of chewing and swallowing for use as a gold standard. The multi-modal data capture was tested by measuring chewing and swallowing in 21 volunteers during periods of food intake and quiet sitting (no food intake). Video footage and sensor signals were manually scored by trained raters. Inter-rater reliability study for three raters conducted on the sample set of five subjects resulted in high average intra-class correlation coefficients of 0.996 for bites, 0.988 for chews and 0.98 for swallows. The collected sensor signals and the resulting manual scores will be used in future research as a gold standard for further assessment of sensor design, development of automatic pattern recognition routines and study of the relationship between swallowing/chewing and ingestive behavior.

146 citations


Cited by
More filters
Journal Article
TL;DR: This book by a teacher of statistics (as well as a consultant for "experimenters") is a comprehensive study of the philosophical background for the statistical design of experiment.
Abstract: THE DESIGN AND ANALYSIS OF EXPERIMENTS. By Oscar Kempthorne. New York, John Wiley and Sons, Inc., 1952. 631 pp. $8.50. This book by a teacher of statistics (as well as a consultant for \"experimenters\") is a comprehensive study of the philosophical background for the statistical design of experiment. It is necessary to have some facility with algebraic notation and manipulation to be able to use the volume intelligently. The problems are presented from the theoretical point of view, without such practical examples as would be helpful for those not acquainted with mathematics. The mathematical justification for the techniques is given. As a somewhat advanced treatment of the design and analysis of experiments, this volume will be interesting and helpful for many who approach statistics theoretically as well as practically. With emphasis on the \"why,\" and with description given broadly, the author relates the subject matter to the general theory of statistics and to the general problem of experimental inference. MARGARET J. ROBERTSON

13,333 citations

Journal ArticleDOI
TL;DR: The task force made recommendations concerning recommended and alternative sensors for the detection of apnea and hypopnea to be used during diagnostic and positive airway pressure (PAP) titration polysomnography, and recommended scoring rules.
Abstract: The American Academy of Sleep Medicine (AASM) Sleep Apnea Definitions Task Force reviewed the current rules for scoring respiratory events in the 2007 AASM Manual for the Scoring and Sleep and Associated Events to determine if revision was indicated. The goals of the task force were (1) to clarify and simplify the current scoring rules, (2) to review evidence for new monitoring technologies relevant to the scoring rules, and (3) to strive for greater concordance between adult and pediatric rules. The task force reviewed the evidence cited by the AASM systematic review of the reliability and validity of scoring respiratory events published in 2007 and relevant studies that have appeared in the literature since that publication. Given the limitations of the published evidence, a consensus process was used to formulate the majority of the task force recommendations concerning revisions.The task force made recommendations concerning recommended and alternative sensors for the detection of apnea and hypopnea to be used during diagnostic and positive airway pressure (PAP) titration polysomnography. An alternative sensor is used if the recommended sensor fails or the signal is inaccurate. The PAP device flow signal is the recommended sensor for the detection of apnea, hypopnea, and respiratory effort related arousals (RERAs) during PAP titration studies. Appropriate filter settings for recording (display) of the nasal pressure signal to facilitate visualization of inspiratory flattening are also specified. The respiratory inductance plethysmography (RIP) signals to be used as alternative sensors for apnea and hypopnea detection are specified. The task force reached consensus on use of the same sensors for adult and pediatric patients except for the following: (1) the end-tidal PCO(2) signal can be used as an alternative sensor for apnea detection in children only, and (2) polyvinylidene fluoride (PVDF) belts can be used to monitor respiratory effort (thoracoabdominal belts) and as an alternative sensor for detection of apnea and hypopnea (PVDFsum) only in adults.The task force recommends the following changes to the 2007 respiratory scoring rules. Apnea in adults is scored when there is a drop in the peak signal excursion by ≥ 90% of pre-event baseline using an oronasal thermal sensor (diagnostic study), PAP device flow (titration study), or an alternative apnea sensor, for ≥ 10 seconds. Hypopnea in adults is scored when the peak signal excursions drop by ≥ 30% of pre-event baseline using nasal pressure (diagnostic study), PAP device flow (titration study), or an alternative sensor, for ≥ 10 seconds in association with either ≥ 3% arterial oxygen desaturation or an arousal. Scoring a hypopnea as either obstructive or central is now listed as optional, and the recommended scoring rules are presented. In children an apnea is scored when peak signal excursions drop by ≥ 90% of pre-event baseline using an oronasal thermal sensor (diagnostic study), PAP device flow (titration study), or an alternative sensor; and the event meets duration and respiratory effort criteria for an obstructive, mixed, or central apnea. A central apnea is scored in children when the event meets criteria for an apnea, there is an absence of inspiratory effort throughout the event, and at least one of the following is met: (1) the event is ≥ 20 seconds in duration, (2) the event is associated with an arousal or ≥ 3% oxygen desaturation, (3) (infants under 1 year of age only) the event is associated with a decrease in heart rate to less than 50 beats per minute for at least 5 seconds or less than 60 beats per minute for 15 seconds. A hypopnea is scored in children when the peak signal excursions drop is ≥ 30% of pre-event baseline using nasal pressure (diagnostic study), PAP device flow (titration study), or an alternative sensor, for ≥ the duration of 2 breaths in association with either ≥ 3% oxygen desaturation or an arousal. In children and adults, surrogates of the arterial PCO(2) are the end-tidal PCO(2) or transcutaneous PCO(2) (diagnostic study) or transcutaneous PCO(2) (titration study). For adults, sleep hypoventilation is scored when the arterial PCO(2) (or surrogate) is > 55 mm Hg for ≥ 10 minutes or there is an increase in the arterial PCO(2) (or surrogate) ≥ 10 mm Hg (in comparison to an awake supine value) to a value exceeding 50 mm Hg for ≥ 10 minutes. For pediatric patients hypoventilation is scored when the arterial PCO(2) (or surrogate) is > 50 mm Hg for > 25% of total sleep time. In adults Cheyne-Stokes breathing is scored when both of the following are met: (1) there are episodes of ≥ 3 consecutive central apneas and/or central hypopneas separated by a crescendo and decrescendo change in breathing amplitude with a cycle length of at least 40 seconds (typically 45 to 90 seconds), and (2) there are five or more central apneas and/or central hypopneas per hour associated with the crescendo/decrescendo breathing pattern recorded over a minimum of 2 hours of monitoring.

3,888 citations

Journal ArticleDOI
TL;DR: In this paper, a review of wearable sensors and systems that are relevant to the field of rehabilitation is presented, focusing on health and wellness, safety, home rehabilitation, assessment of treatment efficacy, and early detection of disorders.
Abstract: The aim of this review paper is to summarize recent developments in the field of wearable sensors and systems that are relevant to the field of rehabilitation. The growing body of work focused on the application of wearable technology to monitor older adults and subjects with chronic conditions in the home and community settings justifies the emphasis of this review paper on summarizing clinical applications of wearable technology currently undergoing assessment rather than describing the development of new wearable sensors and systems. A short description of key enabling technologies (i.e. sensor technology, communication technology, and data analysis techniques) that have allowed researchers to implement wearable systems is followed by a detailed description of major areas of application of wearable technology. Applications described in this review paper include those that focus on health and wellness, safety, home rehabilitation, assessment of treatment efficacy, and early detection of disorders. The integration of wearable and ambient sensors is discussed in the context of achieving home monitoring of older adults and subjects with chronic conditions. Future work required to advance the field toward clinical deployment of wearable sensors and systems is discussed.

1,826 citations

Journal ArticleDOI
TL;DR: The authors provide an overview of these recent developments as well as of formerly proposed algorithms for QRS detection, which reflects the electrical activity within the heart during the ventricular contraction.
Abstract: The QRS complex is the most striking waveform within the electrocardiogram (ECG). Since it reflects the electrical activity within the heart during the ventricular contraction, the time of its occurrence as well as its shape provide much information about the current state of the heart. Due to its characteristic shape it serves as the basis for the automated determination of the heart rate, as an entry point for classification schemes of the cardiac cycle, and often it is also used in ECG data compression algorithms. In that sense, QRS detection provides the fundamentals for almost all automated ECG analysis algorithms. Software QRS detection has been a research topic for more than 30 years. The evolution of these algorithms clearly reflects the great advances in computer technology. Within the last decade many new approaches to QRS detection have been proposed; for example, algorithms from the field of artificial neural networks genetic algorithms wavelet transforms, filter banks as well as heuristic methods mostly based on nonlinear transforms. The authors provide an overview of these recent developments as well as of formerly proposed algorithms.

1,307 citations