Journal ArticleDOI
TL;DR: The state of the art in condition monitoring for power electronics can be found in this paper, where the authors present a review of the current state-of-the-art in power electronics condition monitoring.
Abstract: Condition monitoring (CM) has already been proven to be a cost effective means of enhancing reliability and improving customer service in power equipment, such as transformers and rotating electrical machinery. CM for power semiconductor devices in power electronic converters is at a more embryonic stage; however, as progress is made in understanding semiconductor device failure modes, appropriate sensor technologies, and signal processing techniques, this situation will rapidly improve. This technical review is carried out with the aim of describing the current state of the art in CM research for power electronics. Reliability models for power electronics, including dominant failure mechanisms of devices are described first. This is followed by a description of recently proposed CM techniques. The benefits and limitations of these techniques are then discussed. It is intended that this review will provide the basis for future developments in power electronics CM.

820 citations

Journal ArticleDOI
TL;DR: In this article, the authors proposed a new high-efficiency topology that generates no varying common-mode voltage and requires the same low-input voltage as the bipolar PWM full bridge.
Abstract: When no transformer is used in a grid-connected photovoltaic (PV) system, a galvanic connection between the grid and the PV array exists. In these conditions, dangerous leakage currents (common-mode currents) can appear through the stray capacitance between the PV array and the ground. In order to avoid these leakage currents, different inverter topologies that generate no varying common-mode voltages, such as the half-bridge and the bipolar pulsewidth modulation (PWM) full-bridge topologies, have been proposed. The need of a high-input voltage represents an important drawback of the half-bridge. The bipolar PWM full bridge requires a lower input voltage but exhibits a low efficiency. This letter proposes a new high-efficiency topology that generates no varying common-mode voltage and requires the same low-input voltage as the bipolar PWM full bridge. The proposed topology has been verified in a 5-kW prototype with satisfactory results

650 citations

Journal ArticleDOI
TL;DR: In this article, the authors analyzed the ability of a doubly fed induction generator (DFIG) in a wind turbine to ride through a grid fault and the limitations to its performance.
Abstract: This paper analyzes the ability of a doubly fed induction generator (DFIG) in a wind turbine to ride through a grid fault and the limitations to its performance. The fundamental difficulty for the DFIG in ride-through is the electromotive force (EMF) induced in the machine rotor during the fault, which depends on the dc and negative sequence components in the stator-flux linkage and the rotor speed. The investigation develops a control method to increase the probability of successful grid fault ride-through, given the current and voltage capabilities of the rotor-side converter. A time-domain computer simulation model is developed and laboratory experiments are conducted to verify the model and a control method is proposed. Case studies are then performed on a representatively sized system to define the feasibility regions of successful ride-through for different types of grid faults

617 citations

Journal ArticleDOI
TL;DR: A new high-efficiency topology for transformerless systems is proposed, which does not generate common-mode currents and topologically guarantees that no dc is injected into the grid and has been verified in a 5-kW prototype with satisfactory results.
Abstract: The elimination of the output transformer from grid- connected photovoltaic (PV) systems not only reduces the cost, size, and weight of the conversion stage but also increases the system overall efficiency. However, if the transformer is removed, the galvanic isolation between the PV generator and the grid is lost. This may cause safety hazards in the event of ground faults. In addition, the circulation of leakage currents (common-mode currents) through the stray capacitance between the PV array and the ground would be enabled. Furthermore, when no transformer is used, the inverter could inject direct current (dc) to the grid, causing the saturation of the transformers along the distribution network. While safety requirements in transformerless systems can be met by means of external elements, leakage currents and the injection of dc into the grid must be guaranteed topologically or by the inverter's control system. This paper proposes a new high-efficiency topology for transformerless systems, which does not generate common-mode currents and topologically guarantees that no dc is injected into the grid. The proposed topology has been verified in a 5-kW prototype with satisfactory results.

561 citations

Journal ArticleDOI
TL;DR: An adaptive total sliding-mode control system is designed for the voltage control of the PWM inverter to maintain a sinusoidal output voltage with lower total harmonic distortion and less variation under various output loads.
Abstract: This study develops a high-performance stand-alone photovoltaic (PV) generation system. To make the PV generation system more flexible and expandable, the backstage power circuit is composed of a high step-up converter and a pulsewidth-modulation (PWM) inverter. In the dc-dc power conversion, the high step-up converter is introduced to improve the conversion efficiency in conventional boost converters to allow the parallel operation of low-voltage PV arrays, and to decouple and simplify the control design of the PWM inverter. Moreover, an adaptive total sliding-mode control system is designed for the voltage control of the PWM inverter to maintain a sinusoidal output voltage with lower total harmonic distortion and less variation under various output loads. In addition, an active sun tracking scheme without any light sensors is investigated to make the PV modules face the sun directly for capturing the maximum irradiation and promoting system efficiency. Experimental results are given to verify the validity and reliability of the high step-up converter, the PWM inverter control, and the active sun tracker for the high-performance stand-alone PV generation system.