scispace - formally typeset
Search or ask a question
Author

Nagaaki Ohyama

Bio: Nagaaki Ohyama is an academic researcher from Tokyo Institute of Technology. The author has contributed to research in topics: Color image & Image processing. The author has an hindex of 32, co-authored 258 publications receiving 4480 citations. Previous affiliations of Nagaaki Ohyama include National Institute of Information and Communications Technology.


Papers
More filters
Journal ArticleDOI
TL;DR: A prototype system to realize a personal health data referring system based on the e‐ post‐office box concept is made and is to be used in field trial experiment with the staffs and students of Tokyo Institute of Technology using their ID Card.
Abstract: IT Strategic Headquarters of the Japanese government compiled the Priority Policy Program 2007, in which “Establishment of the structure for every citizen to be able to manage and utilize his health information by himself” and “Foundation of the e‐ Post‐Office box for the realization of the social security service in aspects of people” are declared. For this purpose, a health information system is considered that delivers healthcare data to the server, where the data is to be individually self‐administered by the owner. A patient can register his data, and download or reference it from any medical institution or home when necessary. We made a prototype system to realize such a personal health data referring system based on the e‐ post‐office box concept. The system is to be used in field trial experiment with the staffs and students of Tokyo Institute of Technology using their ID Card. This prototype system is expected to be available for the policy suggestion in the realization of the e‐P.O.Box stated in the Priority Policy Program of the government.

2 citations

Journal ArticleDOI
TL;DR: In this paper, a continuous-discrete mapping model and a filtered backprojection (FBP) method were proposed to correct the shift-variant characteristics of SPECT images.
Abstract: The single photon emission computed tomography (SPECT) imaging system has shift-variant characteristics due to non-uniform attenuation of gamma-ray, collimator design, scattered photons, etc. In order to provide quantitatively accurate SPECT images, these characteristics should be compensated in the reconstruction. This paper presents a new method to correct the shift-variant characteristics, which is based on a continuous-discrete mapping model and filtered backprojection (FBP) method, in which the projection data are assumed to be acquired by narrow ray sum beams in the FBP method and the assumed data set is expressed as a linear combination of the actual projection data. Narrow ray sum beams are approximated by a weighted sum of the original sensitivity functions. Thus, at the reconstruction the projection data are first modified using an approximation and the FBP method is then applied to the corrected projection data and a SPECT image is reconstructed. We further propose a technique that requires the inversion of smaller matrices than the conventional algebraic method; the amount of calculation and memory space become smaller and the stability of the calculation is greatly improved as well. The results of the numerical simulations are also demonstrated.

2 citations

Proceedings ArticleDOI
21 May 1999
TL;DR: A new method is proposed in order to detect interval changes accurately without using an image registration technique based on construction of so-called pattern histogram and comparison procedure and found that the method can be used as an alternative way of temporal change detection, particularly when the precise image registration is not available.
Abstract: An accurate and reliable detection of temporal changes from a pair of images has considerable interest in the medical science. Traditional registration and subtraction techniques can be applied to extract temporal differences when,the object is rigid or corresponding points are obvious. However, in radiological imaging, loss of the depth information, the elasticity of object, the absence of clearly defined landmarks and three-dimensional positioning differences constraint the performance of conventional registration techniques. In this paper, we propose a new method in order to detect interval changes accurately without using an image registration technique. The method is based on construction of so-called pattern histogram and comparison procedure. The pattern histogram is a graphic representation of the frequency counts of all allowable patterns in the multi-dimensional pattern vector space. K-means algorithm is employed to partition pattern vector space successively. Any differences in the pattern histograms imply that different patterns are involved in the scenes. In our experiment, a pair of chest radiographs of pneumoconiosis is employed and the changing histogram bins are visualized on both of the images. We found that the method can be used as an alternative way of temporal change detection, particularly when the precise image registration is not available.

2 citations

Proceedings ArticleDOI
08 May 1995
TL;DR: In this article, an observation system was modeled for each energy window, and Monte Carlo technique was applied for modeling photon transport in a water-filled cylinder, and generalized analytic reconstruction from discrete samples (GARDS) was applied to estimate the source distribution.
Abstract: Scattered radiation in radioisotope imaging is considered in an estimation of radioactivity distribution in order to improve the image quality. To utilize the scattered components in the estimation, an observation system was modeled for each energy window, and Monte Carlo technique was applied for modeling photon transport in a water-filled cylinder. The observation system was assumed to have 8 energy windows between 90 keV and 154 keV for photons emitted by 99mTc, and in order to clearly show the contribution of scattered components, it was also assumed to collect only one view projection data. In computer simulations, generalized analytic reconstruction from discrete samples (GARDS) was applied to estimate the source distribution, and the results show that when a large number of photons are collected, scattered components could improve the image quality.© (1995) COPYRIGHT SPIE--The International Society for Optical Engineering. Downloading of the abstract is permitted for personal use only.

2 citations

Journal ArticleDOI
TL;DR: In this article, a general model for the visualization of the 3D volume data, called optical model (OM), is proposed, which uses the normalized gradient as the normal to the surface where diffusion takes place.

2 citations


Cited by
More filters
Journal Article
TL;DR: In this article, a fast Fourier transform method of topography and interferometry is proposed to discriminate between elevation and depression of the object or wave-front form, which has not been possible by the fringe-contour generation techniques.
Abstract: A fast-Fourier-transform method of topography and interferometry is proposed. By computer processing of a noncontour type of fringe pattern, automatic discrimination is achieved between elevation and depression of the object or wave-front form, which has not been possible by the fringe-contour-generation techniques. The method has advantages over moire topography and conventional fringe-contour interferometry in both accuracy and sensitivity. Unlike fringe-scanning techniques, the method is easy to apply because it uses no moving components.

3,742 citations

Patent
29 Aug 2006
TL;DR: In this paper, a set top box for interacting with broadband media streams, with an adaptive user interface, content-based media processing and/or media metadata processing, and telecommunications integration, is presented.
Abstract: An intelligent electronic appliance preferably includes a user interface, data input and/or output port, and an intelligent processor. A preferred embodiment comprises a set top box for interacting with broadband media streams, with an adaptive user interface, content-based media processing and/or media metadata processing, and telecommunications integration. An adaptive user interface models the user, by observation, feedback, and/or explicit input, and presents a user interface and/or executes functions based on the user model. A content-based media processing system analyzes media content, for example audio and video, to understand the content, for example to generate content-descriptive metadata. A media metadata processing system operates on locally or remotely generated metadata to process the media in accordance with the metadata, which may be, for example, an electronic program guide, MPEG 7 data, and/or automatically generated format. A set top box preferably includes digital trick play effects, and incorporated digital rights management features.

2,644 citations

Patent
06 Jun 1995
TL;DR: An adaptive interface for a programmable system, for predicting a desired user function, based on user history, as well as machine internal status and context, is presented for confirmation by the user, and the predictive mechanism is updated based on this feedback as mentioned in this paper.
Abstract: An adaptive interface for a programmable system, for predicting a desired user function, based on user history, as well as machine internal status and context. The apparatus receives an input from the user and other data. A predicted input is presented for confirmation by the user, and the predictive mechanism is updated based on this feedback. Also provided is a pattern recognition system for a multimedia device, wherein a user input is matched to a video stream on a conceptual basis, allowing inexact programming of a multimedia device. The system analyzes a data stream for correspondence with a data pattern for processing and storage. The data stream is subjected to adaptive pattern recognition to extract features of interest to provide a highly compressed representation which may be efficiently processed to determine correspondence. Applications of the interface and system include a VCR, medical device, vehicle control system, audio device, environmental control system, securities trading terminal, and smart house. The system optionally includes an actuator for effecting the environment of operation, allowing closed-loop feedback operation and automated learning.

1,976 citations

Proceedings ArticleDOI
Jing Huang1, S.R. Kumar1, Mandar Mitra1, Wei-Jing Zhu1, Ramin Zabih1 
17 Jun 1997
TL;DR: Experimental evidence suggests that this new image feature called the color correlogram outperforms not only the traditional color histogram method but also the recently proposed histogram refinement methods for image indexing/retrieval.
Abstract: We define a new image feature called the color correlogram and use it for image indexing and comparison. This feature distills the spatial correlation of colors, and is both effective and inexpensive for content-based image retrieval. The correlogram robustly tolerates large changes in appearance and shape caused by changes in viewing positions, camera zooms, etc. Experimental evidence suggests that this new feature outperforms not only the traditional color histogram method but also the recently proposed histogram refinement methods for image indexing/retrieval.

1,956 citations

Journal Article
TL;DR: In this article, a self-scanned 1024 element photodiode array and a minicomputer are used to measure the phase (wavefront) in the interference pattern of an interferometer to lambda/100.
Abstract: A self-scanned 1024 element photodiode array and minicomputer are used to measure the phase (wavefront) in the interference pattern of an interferometer to lambda/100. The photodiode array samples intensities over a 32 x 32 matrix in the interference pattern as the length of the reference arm is varied piezoelectrically. Using these data the minicomputer synchronously detects the phase at each of the 1024 points by a Fourier series method and displays the wavefront in contour and perspective plot on a storage oscilloscope in less than 1 min (Bruning et al. Paper WE16, OSA Annual Meeting, Oct. 1972). The array of intensities is sampled and averaged many times in a random fashion so that the effects of air turbulence, vibrations, and thermal drifts are minimized. Very significant is the fact that wavefront errors in the interferometer are easily determined and may be automatically subtracted from current or subsequent wavefrots. Various programs supporting the measurement system include software for determining the aperture boundary, sum and difference of wavefronts, removal or insertion of tilt and focus errors, and routines for spatial manipulation of wavefronts. FFT programs transform wavefront data into point spread function and modulus and phase of the optical transfer function of lenses. Display programs plot these functions in contour and perspective. The system has been designed to optimize the collection of data to give higher than usual accuracy in measuring the individual elements and final performance of assembled diffraction limited optical systems, and furthermore, the short loop time of a few minutes makes the system an attractive alternative to constraints imposed by test glasses in the optical shop.

1,300 citations