scispace - formally typeset
Search or ask a question
Author

Novitrian

Other affiliations: Tokyo Institute of Technology
Bio: Novitrian is an academic researcher from Bandung Institute of Technology. The author has contributed to research in topics: Molten salt reactor & Plutonium. The author has an hindex of 6, co-authored 29 publications receiving 112 citations. Previous affiliations of Novitrian include Tokyo Institute of Technology.

Papers
More filters
Journal ArticleDOI
TL;DR: In this paper, a Pb-Bi-water direct contact boiling two-phase flow loop has been fabricated and operated for the development of 45w%Pb-55w%Bi cooled directcontact boiling water small fast reactor (PBWFR).

20 citations

Journal ArticleDOI
TL;DR: In this paper, the use of plutonium and minor actinides (MA) in small Molten Salt Reactor (MSR) with various powers and core sizes has been investigated, and the criticality condition can be achieved if the reactor grade plutonium and MA content in loaded fuel are 7.56%, 6.76, 6.56, 6.,56, and 6,56%, respectively.

18 citations

Journal ArticleDOI
01 Jul 2017
TL;DR: In this paper, a simple apparatus was set up and explained the study of natural convection in a vertical closed-loop system and the results are showing and analyzing in temperature profile data and the speed of coolant flow at some point on the closed loop system.
Abstract: Fukushima nuclear reactor accident occurred due to the reactor cooling pumps and followed by all emergencies cooling systems could not work. Therefore, the system which has a passive safety system that rely on natural laws such as natural convection passive cooling system. In natural convection, the cooling material can flow due to the different density of the material due to the temperature difference. To analyze such investigation, a simple apparatus was set up and explains the study of natural convection in a vertical closed-loop system. It was set up that, in the closed loop, there is a heater at the bottom which is representing heat source system from the reactor core and cooler at the top which is showing the cooling system performance in room temperature to make a temperature difference for convection process. The study aims to find some loop configurations and some natural convection performances that can produce an optimum flow of cooling process. The study was done and focused on experimental approach and simulation. The obtained results are showing and analyzing in temperature profile data and the speed of coolant flow at some point on the closed-loop system.

10 citations

Journal ArticleDOI
TL;DR: In this paper, the boiling heat transfer behavior of lead-bismuth (Pb-Bi) and steam-water direct contact two-phase flow was experimentally investigated and the heat transfer rate was estimated from data of one-dimensional flow direct contact boiling of water in Pb-bi.

10 citations

Journal ArticleDOI
TL;DR: In this article, the characteristics of lead-bismuth(Pb-Bi)-water boiling two-phase flow were investigated experimentally and analytically using a Pb-bi-water direct contact boiling two phase flow loop PbBi flow rates and void fraction were measured in a vertical circular tube at conditions of system pressure 7MPa, liquid metal temperature 460°C and injected water temperature 220°C.
Abstract: The characteristics of lead-bismuth(Pb-Bi)-water boiling two-phase flow were investigated experimentally and analytically using a Pb-Bi-water direct contact boiling two-phase flow loop Pb-Bi flow rates and void fraction were measured in a vertical circular tube at conditions of system pressure 7MPa, liquid metal temperature 460°C and injected water temperature 220°C The drift-flux model with the assumption that bubble sizes were dependent on the fluid surface tension and the density ratio of Pb-Bi to steam-water mixture was chosen and modified by the best fit to the measured void fraction Pb-Bi flow rates were analytically estimated using balance condition between buoyancy force and pressure losses, where the buoyancy force was calculated from void fraction estimated using the modified drift-flux model The deviation of the analytical results of the flow rates from the experimental ones was less than 10%

8 citations


Cited by
More filters
Journal ArticleDOI
TL;DR: In this article , three parallel aluminum-water nanofluid parallel fins are positioned inside the hexagonal compartment with the right as well as left fins are cooled and the middle fin is heated.

52 citations

Journal ArticleDOI
TL;DR: In this paper , the authors used the Galerkin technique to run the entire numerical simulation of a laminar magnetically influenced Ag-MgO-water hybrid nanofluid flow.

45 citations

Journal ArticleDOI
TL;DR: In this paper, a 1D code named LeBENC has been developed at BARC to simulate the natural circulation characteristics in closed loops, including ability to handle non-uniform diameter components, axial thermal conduction in fluid and heat losses from the piping to the environment.

40 citations

Journal ArticleDOI
TL;DR: In this article, the authors proposed a Pb-Bi-cooled direct contact boiling water small fast-reactor (PBWFR) to produce steam by direct contact of feedwater with primary Pb−Bi coolant above the core.

35 citations

Journal ArticleDOI
TL;DR: In this paper, the authors investigated the fragmentation behavior of molten lead alloys droplet in water by releasing liquid LBE (45w%Pb-55w%Bi) and lead droplets into a pool of subcooled water.

25 citations