scispace - formally typeset
Search or ask a question
Author

Orlando Campos

Bio: Orlando Campos is an academic researcher from Federal University of São Paulo. The author has contributed to research in topics: Doppler echocardiography & Ejection fraction. The author has an hindex of 17, co-authored 47 publications receiving 989 citations.

Papers
More filters
Journal ArticleDOI
TL;DR: It is concluded that dobutamine-atropine stress echocardiography is a reasonably safe method for detection of coronary artery disease in the hospital or in an ambulatory basis and the use of new wall motion abnormality as 1 of the end points may prevent further ischemia-related complications.
Abstract: Dobutamine-atropine stress echocardiography (DASE) is an established method and has been shown to be accurate for the detection of coronary artery disease. Still, there are few large clinical studies that analyze the safety of DASE in general or the safety of performing it on an ambulatory basis. Most studies use a target heart rate as the primary end point regardless of whether asymptomatic ischemia occurs. Such studies have shown a serious cardiac event rate of approximately 0.3%. We prospectively studied 4,033 consecutive patients on an ambulatory basis and in the hospital with the use of DASE from July 1991 to December 1998. All tests were performed by an experienced physician, and all clinical and DASE data were stored in a large database organized at the beginning of the study. Dobutamine was infused in scalar doses of 5, 10, 20, 30, and 40 microg/kg per minute in 3-minute stages. Development of a new wall motion abnormality, achievement of 85% of target heart, and end of the DASE infusion protocol were used as an end point. If 85% of the target heart rate was not achieved, atropine was infused up to 1 mg in the absence of myocardial ischemia, which was used in 1,280 studies. There were 3,645 diagnostic tests, and 388 (10%) were found to be nondiagnostic. This result was due to poor image quality in 115 (3%), end of protocol in negative-submaximal examinations in 124 (3%), and limiting side effects in 149 (4%). Thirty-seven percent of the tests showed positive results for myocardial ischemia. Major test-related cardiac complications occurred in 10 (0.25%) patients and included 1 ventricular fibrillation, 1 case of myocardial infarction, and 8 cases of sustained ventricular tachycardia. Atropine poisoning was observed in 5 (0.12%) patients. No deaths occurred as a direct or indirect consequence of DASE. We conclude that dobutamine-atropine stress echocardiography is a reasonably safe method for detection of coronary artery disease in the hospital or in an ambulatory basis. The use of new wall motion abnormality as 1 of the end points may prevent further ischemia-related complications.

113 citations

Journal ArticleDOI
TL;DR: It is concluded that physiologic multivalvular regurgitation is frequent in pregnancy, mainly involving right-sided valves in late gestational periods, occasionally persisting in the early puerperium.

107 citations

Journal ArticleDOI
15 Nov 2009-Heart
TL;DR: CPAP improved LV diastolic function and LA passive emptying, but not LA structural variables in OSA patients.
Abstract: Background: Obstructive sleep apnoea (OSA) has been reported as a predictor of left ventricle (LV) diastolic dysfunction and left atrium (LA) remodelling. The aim of this study is to evaluate the impact of OSA treatment with a continuous positive airway pressure device (CPAP) on the LA volume and function, as well as on the LV diastolic function. Methods: In total, 56 OSA patients were studied. All patients underwent real-time three-dimensional (RT3DE) and two-dimensional echocardiogram with tissue Doppler evaluation in order to estimate LA volumes, function and LV diastolic performance. A total of 30 patients with an apnoea-hypopnoea index greater than 20 were randomly selected to receive sham CPAP (n = 15) or effective CPAP (n = 15) for 24 weeks. They underwent echo examination on three different occasions: at baseline, after 12 weeks and 24 weeks of CPAP or sham CPAP. Results: In the effective CPAP group we observed the following changes from the baseline to the 24-week echo evaluation: (a) a reduction in the E/E′ ratio (10.3 (1.9) to 7.9 (1.3), p = 0.03); (b) an increase in the LA passive emptying fraction (28.8% (11.9%) to 46.8% (9.3%), p = 0.01); and (c) a reduction in the LA active emptying fraction (42.7% (11.5%) to 25.7 (15.7), p Conclusion: CPAP improved LV diastolic function and LA passive emptying, but not LA structural variables in OSA patients. Trial registration number: NCT00768807.

69 citations

Journal ArticleDOI
TL;DR: Using RT3DE, this study demonstrates that OSA induces a functional burden on the left atrium, resulting in remodeling, related to the impairment of diastolic function in this population of patients.
Abstract: Background Studies have suggested that obstructive sleep apnea (OSA) contributes to the deterioration of left ventricular diastolic function. This may lead to atrial myocardial overstretching and enlargement, which could be associated with increased cardiovascular risk. The aim of this study was to evaluate left atrial (LA) volume and function in patients with OSA compared with controls without OSA and their associations with any left ventricular diastolic abnormalities using real-time 3-dimensional echocardiography (RT3DE). Methods Fifty-six patients with mild to severe OSA and 50 controls of similar age and with similar body mass indexes, blood pressure, and frequency of hypertension were analyzed. All subjects underwent polysomnography and RT3DE. Results A larger 3-dimensional maximum LA volume indexed for body surface area, larger volume before atrial contraction, and higher active atrial ejection fraction were found in patients with OSA ( P P = .03), whereas late diastolic velocity (A′) and the ratio of mitral valve early diastolic velocity to mitral annular early diastolic velocity (E/E′) were increased in the same group ( P P = .02). An increase in 3-dimensional maximum LA volume indexed for body surface area was observed, depending on OSA severity. The apnea-hypopnea index and E/E′ ratio were independent predictors of an increase in 3-dimensional maximum LA volume in a multiple regression model. Conclusion Using RT3DE, this study demonstrates that OSA induces a functional burden on the left atrium, resulting in remodeling. These functional and structural changes are related to the impairment of diastolic function in this population.

68 citations

Journal ArticleDOI
TL;DR: There was good agreement between echocardiographic and histologic estimates of myocardial infarct size in rats and the anatomic and functional variables of the left ventricle.
Abstract: Although echocardiography has been used in rats, few studies have determined its efficacy for estimating myocardial infarct size. Our objective was to estimate the myocardial infarct size, and to evaluate anatomic and functional variables of the left ventricle. Myocardial infarction was produced in 43 female Wistar rats by ligature of the left coronary artery. Echocardiography was performed 5 weeks later to measure left ventricular diameter and transverse area (mean of 3 transverse planes), infarct size (percentage of the arc with infarct on 3 transverse planes), systolic function by the change in fractional area, and diastolic function by mitral inflow parameters. The histologic measurement of myocardial infarction size was similar to the echocardiographic method. Myocardial infarct size ranged from 4.8 to 66.6% when determined by histology and from 5 to 69.8% when determined by echocardiography, with good correlation (r = 0.88; P < 0.05; Pearson correlation coefficient). Left ventricular diameter and mean diastolic transverse area correlated with myocardial infarct size by histology (r = 0.57 and r = 0.78; P < 0.0005). The fractional area change ranged from 28.5 ± 5.6 (large-size myocardial infarction) to 53.1 ± 1.5% (control) and correlated with myocardial infarct size by echocardiography (r = -0.87; P < 0.00001) and histology (r = -0.78; P < 00001). The E/A wave ratio of mitral inflow velocity for animals with large-size myocardial infarction (5.6 ± 2.7) was significantly higher than for all others (control: 1.9 ± 0.1; small-size myocardial infarction: 1.9 ± 0.4; moderate-size myocardial infarction: 2.8 ± 2.3). There was good agreement between echocardiographic and histologic estimates of myocardial infarct size in rats.

66 citations


Cited by
More filters
Journal ArticleDOI
TL;DR: It is important that the medical profession play a significant role in critically evaluating the use of diagnostic procedures and therapies as they are introduced in the detection, management, and management of diseases.
Abstract: PREAMBLE......e4 APPENDIX 1......e121 APPENDIX 2......e122 APPENDIX 3......e124 REFERENCES......e124 It is important that the medical profession play a significant role in critically evaluating the use of diagnostic procedures and therapies as they are introduced in the detection, management,

8,362 citations

Journal ArticleDOI
TL;DR: The medical profession should play a central role in evaluating evidence related to drugs, devices, and procedures for detection, management, and prevention of disease.

4,050 citations

Journal ArticleDOI
TL;DR: In this paper, Anderson and Halperin proposed a new FAHA chair, named Jeffrey L. Anderson, MD, FACC, FAHA, Chair-Elect, Nancy M. Albert and Biykem Bozkurt.
Abstract: Jeffrey L. Anderson, MD, FACC, FAHA, Chair , Jonathan L. Halperin, MD, FACC, FAHA, Chair-Elect , Nancy M. Albert, PhD, CCNS, CCRN, FAHA, Biykem Bozkurt, MD, PhD, FACC, FAHA, Ralph G. Brindis, MD, MPH, MACC, Mark A. Creager, MD, FACC, FAHA[§§][1], Lesley H. Curtis, PhD, FAHA, David DeMets, PhD,

2,489 citations