scispace - formally typeset
Search or ask a question
Author

P.-I. Lønne

Bio: P.-I. Lønne is an academic researcher from University of Bergen. The author has contributed to research in topics: Penning trap & Ion source. The author has an hindex of 1, co-authored 1 publications receiving 11 citations.

Papers
More filters
Journal ArticleDOI
TL;DR: In this paper, a compact Radio Frequency Quadrupole (RFQ) ion cooler and buncher device was designed and successfully commissioned as a part of the off-line tuning system of WITCH.
Abstract: During the last several years the WITCH (Weak Interaction Trap for CHarged particles) experimental setup at ISOLDE has undergone various upgrades aiming at improvement of general performance. An essential innovation, a compact Radio Frequency Quadrupole (RFQ) ion cooler and buncher device, was designed and successfully commissioned as a part of the off-line tuning system of WITCH. The RFQ is coupled to the existing surface ionization ion source providing high intensity ion bunches (up to 10 7 ions per bunch) towards the pulsed drift tube and the Penning traps of WITCH. This achievement allows for loading and tuning of the Penning traps in the domain of space charge limits and grants off-line operation independently of the REX-ISOLDE ion source. The current upgrade allows for a more thorough and frequent testing with bunched stable ion beams of high intensities, which will be used for studying various systematic effects involved in experiments with radioactive ions.

12 citations


Cited by
More filters
Journal ArticleDOI
TL;DR: In this paper, the effective transport and cooling of singly charged ions of the isotopes 209Ra to 214Ra in a gas filled radio frequency quadrupole device is reported.
Abstract: A single Ra+ ion stored in a Paul radio frequency ion trap has excellent potential for a precision measurement of the electroweak mixing angle at low momentum transfer and as the most stable optical clock. The effective transport and cooling of singly charged ions of the isotopes 209Ra to 214Ra in a gas filled radio frequency quadrupole device is reported. The absolute frequencies of the transition 7s2S1/2–7d2D3/2 at wavelength 828 nm have been determined in 212–214Ra+ with ≤19 MHz uncertainty using laser spectroscopy on small samples of ions trapped in a linear Paul trap at the online facility Trapped Radioactive Isotopes: µicrolaboratories for fundamental Physics (TRIµP) of the Kernfysisch Versneller Instituut.

23 citations

Journal ArticleDOI
TL;DR: In this paper, a cylindrical Penning trap with a 12-T superconducting magnet provides an increased mass and thus cluster size range, crucial to reach higher anionic charge states by means of the electron-bath method.

14 citations

Journal ArticleDOI
TL;DR: A linear Paul trap for cooling of ion beams, the former cooler for emittance elimination radiofrequency quadrupole (RFQ) at MISTRAL/ISOLDE, has been installed and commissioned at the TRIGA-SPEC experiment located at the research reactor.
Abstract: A linear Paul trap for cooling of ion beams, the former cooler for emittance elimination radiofrequency quadrupole (RFQ) at MISTRAL/ISOLDE, has been installed and commissioned at the TRIGA-SPEC experiment located at the research reactor TRIGA Mainz. It is connected to a hot-surface-ionization ion source and a subsequent mass separator for ionization and pre-separation of neutron-rich fission products as delivered from the reactor. The capability of accumulating and bunching ion beams has been implemented to provide low-emittance ion pulses of 250 ns width containing up to 106 ions. A technical description of the upgraded RFQ as well as its characterization with stable ions is presented. Its installation allows delivery of low-emittance ion bunches to the two branches of the TRIGA-SPEC experiment, namely TRIGA-TRAP and TRIGA-LASER.

12 citations

Journal ArticleDOI
TL;DR: In this article, the first high-statistics and high-resolution data set for the integrated recoil-ion energy spectrum following the decay of 35Ar has been collected with the WITCH retardation spectrometer located at CERN-ISOLDE.
Abstract: The first high-statistics and high-resolution data set for the integrated recoil-ion energy spectrum following the $ \beta^+$ decay of 35Ar has been collected with the WITCH retardation spectrometer located at CERN-ISOLDE. Over 25 million recoil-ion events were recorded on a large-area multichannel plate (MCP) detector with a time-stamp precision of 2ns and position resolution of 0.1mm due to the newly upgraded data acquisition based on the LPC Caen FASTER protocol. The number of recoil ions was measured for more than 15 different settings of the retardation potential, complemented by dedicated background and half-life measurements. Previously unidentified systematic effects, including an energy-dependent efficiency of the main MCP and a radiation-induced time-dependent background, have been identified and incorporated into the analysis. However, further understanding and treatment of the radiation-induced background requires additional dedicated measurements and remains the current limiting factor in extracting a beta-neutrino angular correlation coefficient for 35Ar decay using the WITCH spectrometer.

9 citations

Journal ArticleDOI
TL;DR: In this article, the influence of space charge on ion cyclotron resonances and magnetron eigenfrequency in a gas-filled Penning ion trap has been investigated, and the helium buffer gas pressure in the Penning trap was determined by comparing experimental cooling rates with simulations.
Abstract: The influence of space-charge on ion cyclotron resonances and magnetron eigenfrequency in a gas-filled Penning ion trap has been investigated. Off-line measurements with K+39 using the cooling trap of the WITCH retardation spectrometer-based setup at ISOLDE/CERN were performed. Experimental ion cyclotron resonances were compared with ab initio Coulomb simulations and found to be in agreement. As an important systematic effect of the WITCH experiment, the magnetron eigenfrequency of the ion cloud was studied under increasing space-charge conditions. Finally, the helium buffer gas pressure in the Penning trap was determined by comparing experimental cooling rates with simulations.

8 citations