scispace - formally typeset
Search or ask a question
Author

P.P. Kanjilal

Bio: P.P. Kanjilal is an academic researcher from Indian Institute of Technology Kharagpur. The author has contributed to research in topics: Singular value decomposition & Singular spectrum analysis. The author has an hindex of 12, co-authored 31 publications receiving 900 citations. Previous affiliations of P.P. Kanjilal include Charles River Laboratories & University of Oxford.

Papers
More filters
Journal Article•DOI•
TL;DR: The extraction of fetal electrocardiogram (ECG) from the composite maternal ECG signal obtained from the abdominal lead is discussed, and the proposed method employs singular value decomposition (SVD) and analysis based on the singular value ratio (SVR) spectrum.
Abstract: The extraction of fetal electrocardiogram (ECG) from the composite maternal ECG signal obtained from the abdominal lead is discussed. The proposed method employs singular value decomposition (SVD) and analysis based on the singular value ratio (SVR) spectrum. The maternal ECG (M-ECG) and the fetal ECG (F-ECG) components are identified in terms of the SV-decomposed modes of the appropriately configured data matrices, and elimination of the M-ECG and determination of F-ECG are achieved through selective separation of the SV-decomposed components. The unique feature of the method is that only one composite maternal ECG signal is required to determine the P-ECG component. The method is numerically robust and computationally efficient.

304 citations

Book•
30 Jun 1995
TL;DR: The aim of the book is to provide a unified and comprehensive coverage of the principles, perspectives and methods of adaptive prediction, which is used by scientists and researchers in a wide variety of disciplines.
Abstract: This book is about prediction and control of processes which can be expressed by discrete-time models (i.e. the characteristics vary in some way with time). The aim of the book is to provide a unified and comprehensive coverage of the principles, perspectives and methods of adaptive prediction, which is used by scientists and researchers in a wide variety of disciplines.

97 citations

Journal Article•DOI•
TL;DR: A new concept of decomposition of a signal into component periodic waveforms is presented, configured for the sequential extraction of successively weaker components with different period lengths.
Abstract: This paper presents a new concept of decomposition of a signal into component periodic waveforms. The singular value decomposition (SVD) is used for the detection of periodicity and separation of the component signals. The signal is configured for the sequential extraction of successively weaker components with different period lengths. The approach enjoys the numerical stability associated with SVD. >

93 citations

Journal Article•DOI•
TL;DR: The stable subjects are shown to behave as a low-dimensional system whereas the diseased subjects exhibit comparatively high dimensional activity, and the underlying system in the light of nonlinear dynamical analysis is presented.
Abstract: Qualitative assessment of the overall clinical status of the subject and characterization of complex cardiovascular dynamics from digital blood volume pulsations measured noninvasively using a photo-plethysmographic device is addressed. A novel concept is employed to detect the dominant nonsinusoidal periodicity embedded in the data series and to extract the associated periodic component. The detection and the extraction of periodic component is performed with moving window to accommodate the variations of the physiological oscillations. The covariance matrix formed by the gradually varying pattern is used as a simple measure of qualitative assessment. Further, the characterization of the underlying system in the light of nonlinear dynamical analysis is also presented. The stable subjects are shown to behave as a low-dimensional system whereas the diseased subjects exhibit comparatively high dimensional activity.

69 citations

Journal Article•DOI•
TL;DR: In this article, an explicit method based on minimization of a multistage cost function and a CARIMA plant model formulated in state-space is presented, which can be used to tailor the closed-loop response of the system.
Abstract: Implicit self-tuners based on single-stage cost-function minimization schemes require exact knowledge of the dead-time of the controlled plant. Explicit pole-placement self-tuners on the other hand, though robust against variations of the time-delay, are very sensitive to the assumptions made about the model order of the plant; wrong assumptions may result in very poor performance. An explicit method based on minimization of a multistage cost-function and a CARIMA plant model formulated in state-space is presented. The method extends the design features of the generalized minimum variance scheme to the multistage case; these can be used to tailor the closed-loop response of the system. The approach is shown to be robust against wrong a priori assumptions made about the plant dead-time or order, thus maintaining good servo and disturbance-rejection properties (see Part II).

68 citations


Cited by
More filters
Journal Article•DOI•
W. W. Muir1•
01 May 1981
TL;DR: This chapter discusses Detecting Influential Observations and Outliers, a method for assessing Collinearity, and its applications in medicine and science.
Abstract: 1. Introduction and Overview. 2. Detecting Influential Observations and Outliers. 3. Detecting and Assessing Collinearity. 4. Applications and Remedies. 5. Research Issues and Directions for Extensions. Bibliography. Author Index. Subject Index.

4,948 citations

Journal Article•DOI•
John F. Allen1•
TL;DR: Photoplethysmography is a simple and low-cost optical technique that can be used to detect blood volume changes in the microvascular bed of tissue and is often used non-invasively to make measurements at the skin surface.
Abstract: Photoplethysmography (PPG) is a simple and low-cost optical technique that can be used to detect blood volume changes in the microvascular bed of tissue. It is often used non-invasively to make measurements at the skin surface. The PPG waveform comprises a pulsatile ('AC') physiological waveform attributed to cardiac synchronous changes in the blood volume with each heart beat, and is superimposed on a slowly varying ('DC') baseline with various lower frequency components attributed to respiration, sympathetic nervous system activity and thermoregulation. Although the origins of the components of the PPG signal are not fully understood, it is generally accepted that they can provide valuable information about the cardiovascular system. There has been a resurgence of interest in the technique in recent years, driven by the demand for low cost, simple and portable technology for the primary care and community based clinical settings, the wide availability of low cost and small semiconductor components, and the advancement of computer-based pulse wave analysis techniques. The PPG technology has been used in a wide range of commercially available medical devices for measuring oxygen saturation, blood pressure and cardiac output, assessing autonomic function and also detecting peripheral vascular disease. The introductory sections of the topical review describe the basic principle of operation and interaction of light with tissue, early and recent history of PPG, instrumentation, measurement protocol, and pulse wave analysis. The review then focuses on the applications of PPG in clinical physiological measurements, including clinical physiological monitoring, vascular assessment and autonomic function.

2,836 citations

01 Mar 1995
TL;DR: This thesis applies neural network feature selection techniques to multivariate time series data to improve prediction of a target time series and results indicate that the Stochastics and RSI indicators result in better prediction results than the moving averages.
Abstract: : This thesis applies neural network feature selection techniques to multivariate time series data to improve prediction of a target time series. Two approaches to feature selection are used. First, a subset enumeration method is used to determine which financial indicators are most useful for aiding in prediction of the S&P 500 futures daily price. The candidate indicators evaluated include RSI, Stochastics and several moving averages. Results indicate that the Stochastics and RSI indicators result in better prediction results than the moving averages. The second approach to feature selection is calculation of individual saliency metrics. A new decision boundary-based individual saliency metric, and a classifier independent saliency metric are developed and tested. Ruck's saliency metric, the decision boundary based saliency metric, and the classifier independent saliency metric are compared for a data set consisting of the RSI and Stochastics indicators as well as delayed closing price values. The decision based metric and the Ruck metric results are similar, but the classifier independent metric agrees with neither of the other metrics. The nine most salient features, determined by the decision boundary based metric, are used to train a neural network and the results are presented and compared to other published results. (AN)

1,545 citations

Journal Article•DOI•
David Clarke, C. Mohtadi, P S Tuffs1•
TL;DR: The relationship between GPC and LQ designs is investigated to show the computational advantage of the new approach and the robustness of the GPC approach to model over- and under-parameterization and to fast sampling rates is demonstrated by a set of simulations.

1,273 citations

Journal Article•DOI•
TL;DR: In this paper, the performance of wavelet decomposition-based de-noising and wavelet filter based denoising methods are compared based on signals from mechanical defects, and the comparison result reveals that wavelet filters are more suitable and reliable to detect a weak signature of mechanical impulse-like defect signals, whereas the wavelet transform has a better performance on smooth signal detection.

1,104 citations