scispace - formally typeset
Search or ask a question
Author

Patric Biaggi

Other affiliations: University Health Network
Bio: Patric Biaggi is an academic researcher from University of Zurich. The author has contributed to research in topics: Mitral valve & MitraClip. The author has an hindex of 19, co-authored 51 publications receiving 1352 citations. Previous affiliations of Patric Biaggi include University Health Network.


Papers
More filters
Journal ArticleDOI
15 Jul 2013-Heart
TL;DR: In the first 100 consecutive patients treated with percutaneous MVR in Switzerland between March 2009 and April 2011, APS was achieved in 85%.
Abstract: Background Percutaneous mitral valve repair (MVR) using the MitraClip system has become a valid alternative for patients with severe mitral regurgitation (MR) and high operative risk. Objective To identify clinical and periprocedural factors that may have an impact on clinical outcome. Design Multi-centre longitudinal cohort study. Setting Tertiary referral centres. Patients Here we report on the first 100 consecutive patients treated with percutaneous MVR in Switzerland between March 2009 and April 2011. All of them had moderate–severe (3+) or severe (4+) MR, and 62% had functional MR. 82% of the patients were in New York Heart Association (NYHA) class III/IV, mean left ventricular ejection fraction was 48% and the median European System for Cardiac Operative Risk Evaluation was 16.9%. Interventions MitraClip implantation performed under echocardiographic and fluoroscopic guidance in general anaesthesia. Main outcome measures Clinical, echocardiographic and procedural data were prospectively collected. Results Acute procedural success (APS, defined as successful clip implantation with residual MR grade ≤2+) was achieved in 85% of patients. Overall survival at 6 and 12 months was 89.9% (95% CI 81.8 to 94.6) and 84.6% (95% CI 74.7 to 91.0), respectively. Univariate Cox regression analysis identified APS (p=0.0069) and discharge MR grade (p=0.03) as significant predictors of survival. Conclusions In our consecutive cohort of patients, APS was achieved in 85%. APS and residual discharge MR grade are important predictors of mid-term survival after percutaneous MVR.

134 citations

Journal ArticleDOI
TL;DR: In adults, various forms of congenital heart disease are associated with LVNC, particularly stenotic lesions of the left ventricular outflow tract, Ebstein anomaly, and tetralogy of Fallot.

121 citations

Journal ArticleDOI
15 Jul 2011-Heart
TL;DR: Respiratory and skeletal muscle weakness is common in young adults with complex CHD and similar to that found in older adults with advanced heart failure from acquired heart disease.
Abstract: Background In patients with heart failure from acquired cardiomyopathy, respiratory and skeletal muscle weakness is common and is an independent predictor for adverse events. Despite a different underlying pathology, many young adults with congenital heart disease (CHD) develop a syndrome comparable to heart failure from acquired cardiomyopathy and may be at risk for a similar skeletal muscle weakness. Objectives To assess respiratory and skeletal muscle strength in adults with complex CHD. Methods Respiratory and skeletal muscle function was assessed in 51 adults; 41 with complex CHD (16 tetralogy of Fallot, 11 univentricular anatomy with Fontan operation and 14 with subaortic right ventricles) and 10 controls. Maximal inspiratory (MIPs) and expiratory (MEPs) pressures, handgrip strength, lung volumes and aerobic capacity (peak VO 2 ) were measured. Results In patients with CHD (age 34±13 years), average% predicted MIPs, MEPs and handgrip strength were lower than in controls (77±27% vs 106±28%, 85±32% vs 116±41% and 72±15% vs 93±14%, respectively, p≤0.01). There was no significant difference in muscle weakness between CHD subgroups. In 39% of patients with CHD, the handgrip strength, and in 22%, respiratory muscle strength was 2 (50±12% vs 64±14% predicted, p=0.008). Conclusion Respiratory and skeletal muscle weakness is common in young adults with complex CHD and similar to that found in older adults with advanced heart failure from acquired heart disease.

108 citations

Journal ArticleDOI
15 Jan 2012-Heart
TL;DR: In a heterogeneous population with predominantly functional MR, percutaneous MVR with the Evalve MitraClip system lowers mPCWP, PCWP v-wave and mPAP by 20%, 20% and 8%, respectively, and increases the CI by 32%.
Abstract: Background Percutaneous mitral valve repair (MVR) using the Evalve MitraClip has been recently introduced as a potential alternative to surgical MVR. Objective To assess immediate haemodynamic changes after percutaneous MVR using right heart catheterisation. Design Single-centre longitudinal cohort study. Setting Tertiary referral centre. Patients Fifty consecutive non-surgical patients (age 74±14 years, EuroSCORE 26±14) with moderate to severe (3+) and severe (4+) mitral regurgitation (MR) due to functional (56%), degenerative (30%) or mixed (14%) disease were selected. Interventions MitraClip implantation was performed under general anaesthesia with fluoroscopy and echocardiographic guidance. Haemodynamic variables were obtained before and after MVR using standard right heart catheterisation and oximetry. Main outcome measures Haemodynamic changes immediately before and after MVR. Results Acute procedural success (reduction in MR to grade 2+ or less) was achieved in 46 (92%) patients. Mitral valve clipping reduced mean pulmonary capillary wedge pressure (mPCWP) (from 17±7 to 12±5 mm Hg), PCWP v-wave (from 24±11 to 16±7 mm Hg) and mean pulmonary artery pressure (mPAP) (from 29±12 to 24±6 mm Hg), and increased the cardiac index (CI) (from 3.1±1.0 to 3.9±1.1 l/min/m 2 ) (all p Conclusion In a heterogeneous population with predominantly functional MR, percutaneous MVR with the Evalve MitraClip system lowers mPCWP, PCWP v-wave and mPAP by 20%, 20% and 8%, respectively, and increases the CI by 32%.

103 citations

Journal ArticleDOI
TL;DR: The two contact photoplethysmography-based apps had higher feasibility and better accuracy for heart rate measurement than the two non-contact photoplethaic based apps.
Abstract: BackgroundSmartphone manufacturers offer mobile health monitoring technology to their customers, including apps using the built-in camera for heart rate assessment. This study aimed to test the diagnostic accuracy of such heart rate measuring apps in clinical practice.MethodsThe feasibility and accuracy of measuring heart rate was tested on four commercially available apps using both iPhone 4 and iPhone 5. ‘Instant Heart Rate’ (IHR) and ‘Heart Fitness’ (HF) work with contact photoplethysmography (contact of fingertip to built-in camera), while ‘Whats My Heart Rate’ (WMH) and ‘Cardiio Version’ (CAR) work with non-contact photoplethysmography. The measurements were compared to electrocardiogram and pulse oximetry-derived heart rate.ResultsHeart rate measurement using app-based photoplethysmography was performed on 108 randomly selected patients. The electrocardiogram-derived heart rate correlated well with pulse oximetry (r = 0.92), IHR (r = 0.83) and HF (r = 0.96), but somewhat less with WMH (r = 0.62) and...

102 citations


Cited by
More filters
Journal ArticleDOI
TL;DR: This document provides updated normal values for all four cardiac chambers, including three-dimensional echocardiography and myocardial deformation, when possible, on the basis of considerably larger numbers of normal subjects, compiled from multiple databases.
Abstract: The rapid technological developments of the past decade and the changes in echocardiographic practice brought about by these developments have resulted in the need for updated recommendations to the previously published guidelines for cardiac chamber quantification, which was the goal of the joint writing group assembled by the American Society of Echocardiography and the European Association of Cardiovascular Imaging. This document provides updated normal values for all four cardiac chambers, including three-dimensional echocardiography and myocardial deformation, when possible, on the basis of considerably larger numbers of normal subjects, compiled from multiple databases. In addition, this document attempts to eliminate several minor discrepancies that existed between previously published guidelines.

11,568 citations

Journal Article
TL;DR: 1. Place animal in induction chamber and anesthetize the mouse and ensure sedation, move it to a nose cone for hair removal using cream and reduce anesthesia to maintain proper heart rate.
Abstract: 1. Place animal in induction chamber and anesthetize the mouse and ensure sedation. 2. Once the animal is sedated, move it to a nose cone for hair removal using cream. Only apply cream to the area of the chest that will be utilized for imaging. Once the hair is removed, wipe area with wet gauze to ensure all hair is removed. 3. Move the animal to the imaging platform and tape its paws to the ECG lead plates and insert rectal probe. Body temperature should be maintained at 36-37°C. During imaging, reduce anesthesia to maintain proper heart rate. If the animal shows signs of being awake, use a higher concentration of anesthetic.

1,557 citations

Journal ArticleDOI
TL;DR: Autores/Miembros del Grupo de Trabajo: Raimund Erbel ( coordinador) (Alemania), Victor Aboyans (Coordinado) ( Francia), Catherine Boileau (Francia), Eduardo Bossone (Italia), Roberto Di Bartolomeo (It Italy), Holger Eggebrecht (AleGermany)
Abstract: Autores/Miembros del Grupo de Trabajo: Raimund Erbel (Coordinador) (Alemania), Victor Aboyans (Coordinador) (Francia), Catherine Boileau (Francia), Eduardo Bossone (Italia), Roberto Di Bartolomeo (Italia), Holger Eggebrecht (Alemania), Arturo Evangelista (Espana), Volkmar Falk (Suiza), Herbert Frank (Austria), Oliver Gaemperli (Suiza), Martin Grabenwoger (Austria), Axel Haverich (Alemania), Bernard Iung (Francia), Athanasios John Manolis (Grecia), Folkert Meijboom (Paises Bajos), Christoph A. Nienaber (Alemania), Marco Roffi (Suiza), Herve Rousseau (Francia), Udo Sechtem (Alemania), Per Anton Sirnes (Noruega), Regula S. von Allmen (Suiza) y Christiaan J.M. Vrints (Belgica)

963 citations