scispace - formally typeset
Search or ask a question
Author

Piera Raspollini

Other affiliations: University of Bologna
Bio: Piera Raspollini is an academic researcher from National Research Council. The author has contributed to research in topics: Atmospheric sounding & Environmental science. The author has an hindex of 16, co-authored 45 publications receiving 822 citations. Previous affiliations of Piera Raspollini include University of Bologna.


Papers
More filters
Journal ArticleDOI
TL;DR: An optimized code to perform the near-real-time retrieval of profiles of pressure, temperature, and volume mixing ratio (VMR) of five key species from infrared limb spectra recorded by the Michelson Interferometer for Passive Atmospheric Sounding (MIPAS) experiment on board the European Space Agency (ESA) Environmental Satellite ENVISAT-1 was developed.
Abstract: An optimized code to perform the near-real-time retrieval of profiles of pressure, temperature, and volume mixing ratio (VMR) of five key species (O3, H2O, HNO3, CH4, and N2O) from infrared limb spectra recorded by the Michelson Interferometer for Passive Atmospheric Sounding (MIPAS) experiment on board the European Space Agency (ESA) Environmental Satellite ENVISAT-1 was developed as part of a ESA-supported study. The implementation uses the global fit approach on selected narrow spectral intervals (microwindows) to retrieve each profile in sequence. The trade-off between run time and accuracy of the retrieval was optimized from both the physical and the mathematical points of view, with optimizations in the program structure, in the radiative transfer model, and in the computation of the retrieval Jacobian. The attained performances of the retrieval code are noise error on temperature <2 K at all the altitudes covered by the typical MIPAS scan (8–53 km with 3-km resolution), noise error on tangent pressure <3%, and noise error on VMR of the target species <5% at most of the altitudes covered by the standard MIPAS scan, with a total run time of less than 1 min on a modern workstation.

183 citations

Journal ArticleDOI
TL;DR: The ACE Fourier Transform Spectrometer (ACE-FTS) as discussed by the authors was used to measure volume mixing ratio (VMR) profiles of nitrous oxide (N 2 O) from the upper troposphere to the lower mesosphere at a vertical resolution of about 3-4 km.
Abstract: The Atmospheric Chemistry Experiment (ACE), also known as SCISAT, was launched on 12 August 2003, carrying two instruments that measure vertical profiles of atmospheric constituents using the solar occultation technique. One of these instruments, the ACE Fourier Transform Spectrometer (ACE-FTS), is measuring volume mixing ratio (VMR) profiles of nitrous oxide (N 2 O) from the upper troposphere to the lower mesosphere at a vertical resolution of about 3–4 km. In this study, the quality of the ACE-FTS version 2.2 N 2 O data is assessed through comparisons with coincident measurements made by other satellite, balloon-borne, aircraft, and ground-based instruments. These consist of vertical profile comparisons with the SMR, MLS, and MIPAS satellite instruments, multiple aircraft flights of ASUR, and single balloon flights of SPIRALE and FIRS-2, and partial column comparisons with a network of ground-based Fourier Transform InfraRed spectrometers (FTIRs). Overall, the quality of the ACE-FTS version 2.2 N 2 O VMR profiles is good over the entire altitude range from 5 to 60 km. Between 6 and 30 km, the mean absolute differences for the satellite comparisons lie between -42 ppbv and +17 ppbv, with most within ±20 ppbv. This corresponds to relative deviations from the mean that are within ±15%, except for comparisons with MIPAS near 30 km, for which they are as large as 22.5%. Between 18 and 30 km, the mean absolute differences are generally within ±10 ppbv, again excluding the aircraft and balloon comparisons. From 30 to 60 km, the mean absolute differences are within ±4 ppbv, and are mostly between -2 and +1 ppbv. Given the small N 2 O VMR in this region, the relative deviations from the mean are therefore large at these altitudes, with most suggesting a negative bias in the ACE-FTS data between 30 and 50 km. In the comparisons with the FTIRs, the mean relative differences between the ACE-FTS and FTIR partial columns are within ±6.6% for eleven of the twelve contributing stations. This mean relative difference is negative at ten stations, suggesting a small negative bias in the ACE-FTS partial columns over the altitude regions compared. Excellent correlation ( R =0.964) is observed between the ACE-FTS and FTIR partial columns, with a slope of 1.01 and an intercept of -0.20 on the line fitted to the data.

79 citations

Journal ArticleDOI
TL;DR: In this article, the ACE Fourier Transform Spectrometer (ACE-FTS) was used to measure vertical profiles of over 30 atmospheric trace gases by analyzing solar occultation spectra in the ultraviolet/visible and infrared wavelength regions.
Abstract: The Atmospheric Chemistry Experiment (ACE) satellite was launched on 12 August 2003. Its two instruments measure vertical profiles of over 30 atmospheric trace gases by analyzing solar occultation spectra in the ultraviolet/visible and infrared wavelength regions. The reservoir gases HNO3, ClONO2, and N2O5 are three of the key species provided by the primary instrument, the ACE Fourier Transform Spectrometer (ACE-FTS). This paper describes the ACE-FTS version 2.2 data products, including the N2O5 update, for the three species and presents validation comparisons with available observations. We have compared volume mixing ratio (VMR) profiles of HNO3, ClONO2, and N2O5 with measurements by other satellite instruments (SMR, MLS, MIPAS), aircraft measurements (ASUR), and single balloon-flights (SPIRALE, FIRS-2). Partial columns of HNO3 and ClONO2 were also compared with measurements by ground-based Fourier Transform Infrared (FTIR) spectrometers. Overall the quality of the ACE-FTS v2.2 HNO3 VMR profiles is good from 18 to 35 km. For the statistical satellite comparisons, the mean absolute differences are generally within ±1 ppbv ±20%) from 18 to 35 km. For MIPAS and MLS comparisons only, mean relative differences lie within±10% between 10 and 36 km. ACE-FTS HNO3 partial columns (~15–30 km) show a slight negative bias of −1.3% relative to the ground-based FTIRs at latitudes ranging from 77.8° S–76.5° N. Good agreement between ACE-FTS ClONO2 and MIPAS, using the Institut fur Meteorologie und Klimaforschung and Instituto de Astrofisica de Andalucia (IMK-IAA) data processor is seen. Mean absolute differences are typically within ±0.01 ppbv between 16 and 27 km and less than +0.09 ppbv between 27 and 34 km. The ClONO2 partial column comparisons show varying degrees of agreement, depending on the location and the quality of the FTIR measurements. Good agreement was found for the comparisons with the midlatitude Jungfraujoch partial columns for which the mean relative difference is 4.7%. ACE-FTS N2O5 has a low bias relative to MIPAS IMK-IAA, reaching −0.25 ppbv at the altitude of the N2O5 maximum (around 30 km). Mean absolute differences at lower altitudes (16–27 km) are typically −0.05 ppbv for MIPAS nighttime and ±0.02 ppbv for MIPAS daytime measurements.

66 citations

Journal ArticleDOI
TL;DR: A computational strategy that reduces the large number of computer resources apparently demanded by the proposed inversion algorithm is described, and its performance is shown with a simulated retrieval analysis based on a satellite experiment planned to fly during 2001.
Abstract: We propose a new approach to the analysis of limb-scanning measurements of the atmosphere that are continually recorded from an orbiting platform. The retrieval is based on the simultaneous analysis of observations taken along the whole orbit. This approach accounts for the horizontal variability of the atmosphere, hence avoiding the errors caused by the assumption of horizontal homogeneity along the line of sight of the observations. A computer program that implements the proposed approach has been designed; its performance is shown with a simulated retrieval analysis based on a satellite experiment planned to fly during 2001. This program has also been used for determining the size and the character of the errors that are associated with the assumption of horizontal homogeneity. A computational strategy that reduces the large number of computer resources apparently demanded by the proposed inversion algorithm is described.

66 citations

Journal ArticleDOI
TL;DR: In this paper, the authors compared ACE-FTS version 3.5 profiles that are collocated with MIPAS and MLS, and analyzed the differences between instrument retrievals for Northern and Southern hemispheres and for local morning and evening data.
Abstract: The atmospheric limb sounders, ACE-FTS on the SCISAT satellite, MIPAS on ESA׳s Envisat satellite, and MLS on NASA׳s Aura satellite, take measurements used to retrieve atmospheric profiles of O3, N2O, H2O, HNO3, and CO. Each was taking measurements between February 2004 and April 2012 (ACE-FTS and MLS are currently operational), providing hundreds of profile coincidences in the Northern and Southern hemispheres, and during local morning and evening. Focusing on determining diurnal and hemispheric biases in the ACE-FTS data, this study compares ACE-FTS version 3.5 profiles that are collocated with MIPAS and MLS, and analyzes the differences between instrument retrievals for Northern and Southern hemispheres and for local morning and evening data. For O3, ACE-FTS is typically within ±5% of mid-stratospheric MIPAS and MLS data and exhibits a positive bias of ~10 to 20% in the upper stratosphere – lower mesosphere. For H2O, ACE-FTS exhibits an average bias of −5% between 20 and 60 km. For N2O, ACE-FTS agrees with MIPAS and MLS within −20 to +10% up to 45 km and 35 km, respectively. For HNO3, ACE-FTS typically agrees within ±10% below 30 km, and exhibits a positive bias of ~10 to 20% above 30 km. With respect to MIPAS CO, ACE-FTS exhibits an average −11% bias between 28 and 50 km, and at higher altitudes a positive bias on the order of 10% (>100%) in the winter (summer). With respect to winter MLS CO, ACE-FTS is typically within ±10% between 25 and 40 km, and has an average bias of −11% above 40 km.

49 citations


Cited by
More filters
Journal ArticleDOI
TL;DR: The new HITRAN is greatly extended in terms of accuracy, spectral coverage, additional absorption phenomena, added line-shape formalisms, and validity, and molecules, isotopologues, and perturbing gases have been added that address the issues of atmospheres beyond the Earth.
Abstract: This paper describes the contents of the 2016 edition of the HITRAN molecular spectroscopic compilation. The new edition replaces the previous HITRAN edition of 2012 and its updates during the intervening years. The HITRAN molecular absorption compilation is composed of five major components: the traditional line-by-line spectroscopic parameters required for high-resolution radiative-transfer codes, infrared absorption cross-sections for molecules not yet amenable to representation in a line-by-line form, collision-induced absorption data, aerosol indices of refraction, and general tables such as partition sums that apply globally to the data. The new HITRAN is greatly extended in terms of accuracy, spectral coverage, additional absorption phenomena, added line-shape formalisms, and validity. Moreover, molecules, isotopologues, and perturbing gases have been added that address the issues of atmospheres beyond the Earth. Of considerable note, experimental IR cross-sections for almost 300 additional molecules important in different areas of atmospheric science have been added to the database. The compilation can be accessed through www.hitran.org. Most of the HITRAN data have now been cast into an underlying relational database structure that offers many advantages over the long-standing sequential text-based structure. The new structure empowers the user in many ways. It enables the incorporation of an extended set of fundamental parameters per transition, sophisticated line-shape formalisms, easy user-defined output formats, and very convenient searching, filtering, and plotting of data. A powerful application programming interface making use of structured query language (SQL) features for higher-level applications of HITRAN is also provided.

7,638 citations

Journal ArticleDOI
TL;DR: The Michelson Interferometer for Pas- sive Atmospheric Sounding (MIPAS) is a mid-infrared emission spectrometer which is part of the core payload of ENVISAT as mentioned in this paper.
Abstract: MIPAS, the Michelson Interferometer for Pas- sive Atmospheric Sounding, is a mid-infrared emission spectrometer which is part of the core payload of ENVISAT. It is a limb sounder, i.e. it scans across the horizon detecting atmospheric spectral radiances which are inverted to verti- cal temperature, trace species and cloud distributions. These data can be used for scientific investigations in various re- search fields including dynamics and chemistry in the alti- tude region between upper troposphere and lower thermo- sphere. The instrument is a well calibrated and characterized Fourier transform spectrometer which is able to detect many trace constituents simultaneously. The different concepts of retrieval methods are described including multi-target and two-dimensional retrievals. Operationally generated data sets consist of temperature, H2O, O3, CH4, N2O, HNO3, and NO2 profiles. Measurement errors are investigated in de- tail and random and systematic errors are specified. The re- sults are validated by independent instrumentation which has been operated at ground stations or aboard balloon gondolas and aircraft. Intercomparisons of MIPAS measurements with other satellite data have been carried out, too. As a result, it

562 citations

01 Dec 2003
TL;DR: ACE as discussed by the authors is a Canadian satellite mission that will provide measurements leading to an improved understanding of the chemical and dynamical processes that control the distribution of ozone in the stratosphere, including a Fourier transform infrared spectrometer, a UV/visible/near IR spectrograph and a two-channel solar imager.
Abstract: ACE is a Canadian satellite mission that will provide measurements leading to an improved understanding of the chemical and dynamical processes that control the distribution of ozone in the stratosphere. The ACE instruments are a Fourier transform infrared spectrometer, a UV/visible/near IR spectrograph and a two-channel solar imager, all working in solar occultation mode. ACE was successfully launched on August 12, 2003.

478 citations

Journal ArticleDOI
TL;DR: The GEISA database as mentioned in this paper is a computer-accessible system comprising three independent sub-databases devoted, respectively, to: line parameters, infrared and ultraviolet/visible absorption cross-sections, microphysical and optical properties of atmospheric aerosols.
Abstract: The updated 2009 edition of the spectroscopic database GEISA (Gestion et Etude des Informations Spectroscopiques Atmospheriques; Management and Study of Atmospheric Spectroscopic Information) is described in this paper. GEISA is a computer-accessible system comprising three independent sub-databases devoted, respectively, to: line parameters, infrared and ultraviolet/visible absorption cross-sections, microphysical and optical properties of atmospheric aerosols. In this edition, 50 molecules are involved in the line parameters sub-database, including 111 isotopologues, for a total of 3,807,997 entries, in the spectral range from 10−6 to 35,877.031 cm−1. The successful performances of the new generation of hyperspectral sounders depend ultimately on the accuracy to which the spectroscopic parameters of the optically active atmospheric gases are known, since they constitute an essential input to the forward radiative transfer models that are used to interpret their observations. Currently, GEISA is involved in activities related to the assessment of the capabilities of IASI (Infrared Atmospheric Sounding Interferometer; http://smsc.cnes.fr/IASI/index.htm) on board the METOP European satellite through the GEISA/IASI database derived from GEISA. Since the Metop-A (http://www.eumetsat.int) launch (19 October 2006), GEISA is the reference spectroscopic database for the validation of the level-1 IASI data. Also, GEISA is involved in planetary research, i.e., modeling of Titan's atmosphere, in the comparison with observations performed by Voyager, or by ground-based telescopes, and by the instruments on board the Cassini–Huygens mission. GEISA, continuously developed and maintained at LMD (Laboratoire de Meteorologie Dynamique, France) since 1976, is implemented on the IPSL/CNRS (France) “Ether” Products and Services Centre WEB site (http://ether.ipsl.jussieu.fr), where all archived spectroscopic data can be handled through general and user friendly associated management software facilities. More than 350 researchers are registered for on line use of GEISA.

332 citations

Journal ArticleDOI
TL;DR: In this article, the performance of the version 2.2.2 water vapor and nitrous oxide measurements from the Microwave Limb Sounder (MLS) on the Earth Observing System (EOS) Aura satellite is assessed.
Abstract: [1] The quality of the version 2.2 (v2.2) middle atmosphere water vapor and nitrous oxide measurements from the Microwave Limb Sounder (MLS) on the Earth Observing System (EOS) Aura satellite is assessed. The impacts of the various sources of systematic error are estimated by a comprehensive set of retrieval simulations. Comparisons with correlative data sets from ground-based, balloon and satellite platforms operating in the UV/visible, infrared and microwave regions of the spectrum are performed. Precision estimates are also validated, and recommendations are given on the data usage. The v2.2 H2O data have been improved over v1.5 by providing higher vertical resolution in the lower stratosphere and better precision above the stratopause. The single-profile precision is � 0.2–0.3 ppmv (4–9%), and the vertical resolution is � 3–4 km in the stratosphere. The precision and vertical resolution become worse with increasing height above the stratopause. Over the pressure range 0.1–0.01 hPa the precision degrades from 0.4 to 1.1 ppmv (6–34%), and the vertical resolution degrades to � 12–16 km. The accuracy is estimated to be 0.2–0.5 ppmv (4–11%) for the pressure range 68–0.01 hPa. The scientifically useful range of the H2O data is from 316 to 0.002 hPa, although only the 82–0.002 hPa pressure range is validated here. Substantial improvement has been achieved in the v2.2 N2O data over v1.5 by reducing a significant low bias in the stratosphere and eliminating unrealistically high biased mixing ratios in the polar regions. The single-profile precision is � 13–25 ppbv (7–38%), the vertical resolution is � 4–6 km and the accuracy is estimated to be 3–70 ppbv (9–25%) for the pressure range 100–4.6 hPa. The scientifically useful range of the N2O data is from 100 to 1 hPa.

268 citations