Author
Prashant Kumar
Other affiliations: Southeast University, Dr. B. R. Ambedkar National Institute of Technology Jalandhar, Trinity College, Dublin ...read more
Bio: Prashant Kumar is an academic researcher from University of Surrey. The author has contributed to research in topics: Air quality index & Medicine. The author has an hindex of 54, co-authored 363 publications receiving 11561 citations. Previous affiliations of Prashant Kumar include Southeast University & Dr. B. R. Ambedkar National Institute of Technology Jalandhar.
Papers published on a yearly basis
Papers
More filters
••
TL;DR: It is concluded that the influences of different GI options on air quality in street canyons depend on street canyon geometry, meteorological conditions and vegetation characteristics, and a need for further research, particularly on green walls and green screens, to substantiate their efficacy and investigate technical considerations.
95 citations
••
TL;DR: In this article, chemical looping combustion (CLC), pre-combustion and oxy-fuel combustion technologies are compared to those of a conventional IGCC plant without CO2 capture.
Abstract: Carbon dioxide (CO2) emitted from conventional coal-based power plants is a growing concern for the environment. Chemical looping combustion (CLC), pre-combustion and oxy-fuel combustion are promising CO2 capture technologies which allow clean electricity generation from coal in an integrated gasification combined cycle (IGCC) power plant. This work compares the characteristics of the above three capture technologies to those of a conventional IGCC plant without CO2 capture. CLC technology is also investigated for two different process configurations—(i) an integrated gasification combined cycle coupled with chemical looping combustion (IGCC–CLC), and (ii) coal direct chemical looping combustion (CDCLC)—using exergy analysis to exploit the complete potential of CLC. Power output, net electrical efficiency and CO2 capture efficiency are the key parameters investigated for the assessment. Flowsheet models of five different types of IGCC power plants, (four with and one without CO2 capture), were developed in the Aspen plus simulation package. The results indicate that with respect to conventional IGCC power plant, IGCC–CLC exhibited an energy penalty of 4.5%, compared with 7.1% and 9.1% for pre-combustion and oxy-fuel combustion technologies, respectively. IGCC–CLC and oxy-fuel combustion technologies achieved an overall CO2 capture rate of ∼100% whereas pre-combustion technology could capture ∼94.8%. Modification of IGCC–CLC into CDCLC tends to increase the net electrical efficiency by 4.7% while maintaining 100% CO2 capture rate. A detailed exergy analysis performed on the two CLC process configurations (IGCC–CLC and CDCLC) and conventional IGCC process demonstrates that CLC technology can be thermodynamically as efficient as a conventional IGCC process.
93 citations
••
TL;DR: In this article, the authors conducted 15 different field measurement campaigns between 2007 and 2011 at 13 indi- vidual sites in China, including five urban sites, four regional sites, three coastal/background sites and one ship cruise mea- surement along eastern coastline of China.
Abstract: Understanding the particle number size distribu- tions in diversified atmospheric environments is important in order to design mitigation strategies related to submicron particles and their effects on regional air quality, haze and human health. In this study, we conducted 15 different field measurement campaigns between 2007 and 2011 at 13 indi- vidual sites in China, including five urban sites, four regional sites, three coastal/background sites and one ship cruise mea- surement along eastern coastline of China. Size resolved particles were measured in the 15-600 nm size range. The median particle number concentrations (PNCs) were found to vary in the range of 1.1-2.2 ◊ 10 4 cm 3 at urban sites, 0.8-1.5◊ 10 4 cm 3 at regional sites, 0.4-0.6 ◊ 10 4 cm 3 at coastal/background sites, and 0.5 ◊ 10 4 cm 3 during cruise
92 citations
••
TL;DR: In this paper, the authors used a particle spectrometer with various lengths of sampling tube to measure the particle number distributions in the 5-2738 nm range. But the results showed that the laminar flow model did not reflect the observations for small Re. This may be due to the sampling tubes not being kept straight or other complications.
90 citations
••
TL;DR: In this paper, a comparison between measured and modelled particle number concentrations (PNCs) in the 10-300-nm size range at different heights in a canyon is presented.
89 citations
Cited by
More filters
•
TL;DR: In this article, the authors present a document, redatto, voted and pubblicato by the Ipcc -Comitato intergovernativo sui cambiamenti climatici - illustra la sintesi delle ricerche svolte su questo tema rilevante.
Abstract: Cause, conseguenze e strategie di mitigazione Proponiamo il primo di una serie di articoli in cui affronteremo l’attuale problema dei mutamenti climatici. Presentiamo il documento redatto, votato e pubblicato dall’Ipcc - Comitato intergovernativo sui cambiamenti climatici - che illustra la sintesi delle ricerche svolte su questo tema rilevante.
4,187 citations
••
4,069 citations
••
Turku University Hospital1, National University of Ireland, Galway2, University of Catania3, University of Naples Federico II4, University of Paris5, Bispebjerg Hospital6, University of Sheffield7, University of Cambridge8, Stavanger University Hospital9, Oslo University Hospital10, Hospital Clínico San Carlos11, Mayo Clinic12, University of Western Brittany13, Rabin Medical Center14, Slovak Medical University15, Saarland University16, University of Barcelona17, University of Brescia18, University of Bern19, University of Erlangen-Nuremberg20, Leiden University Medical Center21
TL;DR: In this article, the authors present guidelines for the management of patients with coronary artery disease (CAD), which is a pathological process characterized by atherosclerotic plaque accumulation in the epicardial arteries.
Abstract: Coronary artery disease (CAD) is a pathological process characterized by atherosclerotic plaque accumulation in the epicardial arteries, whether obstructive or non-obstructive. This process can be modified by lifestyle adjustments, pharmacological therapies, and invasive interventions designed to achieve disease stabilization or regression. The disease can have long, stable periods but can also become unstable at any time, typically due to an acute atherothrombotic event caused by plaque rupture or erosion. However, the disease is chronic, most often progressive, and hence serious, even in clinically apparently silent periods. The dynamic nature of the CAD process results in various clinical presentations, which can be conveniently categorized as either acute coronary syndromes (ACS) or chronic coronary syndromes (CCS). The Guidelines presented here refer to the management of patients with CCS. The natural history of CCS is illustrated in Figure 1.
3,448 citations
01 Jan 2015
TL;DR: The work of the IPCC Working Group III 5th Assessment report as mentioned in this paper is a comprehensive, objective and policy neutral assessment of the current scientific knowledge on mitigating climate change, which has been extensively reviewed by experts and governments to ensure quality and comprehensiveness.
Abstract: The talk with present the key results of the IPCC Working Group III 5th assessment report. Concluding four years of intense scientific collaboration by hundreds of authors from around the world, the report responds to the request of the world's governments for a comprehensive, objective and policy neutral assessment of the current scientific knowledge on mitigating climate change. The report has been extensively reviewed by experts and governments to ensure quality and comprehensiveness.
3,224 citations