scispace - formally typeset
Search or ask a question
Author

Purnendu K. Dasgupta

Bio: Purnendu K. Dasgupta is an academic researcher from University of Texas at Arlington. The author has contributed to research in topics: Ion chromatography & Detection limit. The author has an hindex of 62, co-authored 506 publications receiving 16779 citations. Previous affiliations of Purnendu K. Dasgupta include Dow Chemical Company & Texas Tech University.


Papers
More filters
Journal ArticleDOI
TL;DR: It is shown here that by controlling the amount of porogen added during the synthesis of monolithic polymers derived from ethylene dimethacrylate - glycidyl methacrylated, it is possible to obtain rigid ion exchange polymers that behave like IEMs and allow only one charge type of ions to pass through, i.e., are permselective.

17 citations

Journal ArticleDOI
TL;DR: This paper shows that the linear dynamic range technique is particularly powerful with a high resolution time of flight mass spectrometer because the data for all ions are automatically acquired, and it is demonstrated this for four small organic molecules; the upper limits of LDRs increased by 25-50 times.

17 citations

Journal ArticleDOI
TL;DR: In this article, a cellule de mesure comprenant de two electrodes and fonctionnant sous flux is presented. But this cellule is not suitable for chromatographie ionique.
Abstract: Conception et utilisation d'un detecteur pour la chromatographie ionique, constitue d'une cellule de mesure comprenant deux electrodes et fonctionnant sous flux

17 citations

Journal ArticleDOI
TL;DR: With an electrodialytic capillary suppressor coupled to an AS18 latex-coated surface-sulfonated cyclo-olefin polymer (COP) capillary column and using an on-capillary admittance detector (AD), the feasibility of both isocratic and gradient SC-OTIC was demonstrated.
Abstract: We describe an electrodialytic capillary suppressor for suppressed conductometric open tubular ion chromatography (SC-OTIC). For practical eluent concentrations, suppressor active lengths less than ∼1 mm are adequate. In its preferred embodiment, the suppressor consists of a solid polymer ion exchanger block. Two 0.45-mm-diameter parallel cylindrical passages are provided: these provide for passage of regenerant water and placement of platinum wire electrodes. The suppression channel is made by making a crack in the soft polymer block, using a needle 0.3 mm in diameter. The suppression channel runs parallel to and is flanked by the two aforementioned electrode channels through which water is pumped. The suppressor ends of the separation and the detection capillaries are tapered. The tapered ends of the capillaries are inserted into the suppression channel with the tips 0.4–1.1 mm apart. Using a suppression length of 1 mm, we were able to suppress 100 mM hydroxide @ 100 nL/min (10 neq/min). With such a sup...

17 citations


Cited by
More filters
Journal ArticleDOI
27 Jul 2006-Nature
TL;DR: The manipulation of fluids in channels with dimensions of tens of micrometres — microfluidics — has emerged as a distinct new field that has the potential to influence subject areas from chemical synthesis and biological analysis to optics and information technology.
Abstract: The manipulation of fluids in channels with dimensions of tens of micrometres--microfluidics--has emerged as a distinct new field. Microfluidics has the potential to influence subject areas from chemical synthesis and biological analysis to optics and information technology. But the field is still at an early stage of development. Even as the basic science and technological demonstrations develop, other problems must be addressed: choosing and focusing on initial applications, and developing strategies to complete the cycle of development, including commercialization. The solutions to these problems will require imagination and ingenuity.

8,260 citations

Journal ArticleDOI
TL;DR: It is reported that magnetite nanoparticles in fact possess an intrinsic enzyme mimetic activity similar to that found in natural peroxidases, which are widely used to oxidize organic substrates in the treatment of wastewater or as detection tools.
Abstract: Nanoparticles containing magnetic materials, such as magnetite (Fe3O4), are particularly useful for imaging and separation techniques. As these nanoparticles are generally considered to be biologically and chemically inert, they are typically coated with metal catalysts, antibodies or enzymes to increase their functionality as separation agents. Here, we report that magnetite nanoparticles in fact possess an intrinsic enzyme mimetic activity similar to that found in natural peroxidases, which are widely used to oxidize organic substrates in the treatment of wastewater or as detection tools. Based on this finding, we have developed a novel immunoassay in which antibody-modified magnetite nanoparticles provide three functions: capture, separation and detection. The stability, ease of production and versatility of these nanoparticles makes them a powerful tool for a wide range of potential applications in medicine, biotechnology and environmental chemistry.

4,500 citations

Journal ArticleDOI
TL;DR: The ability of DLLME technique in the extraction of other organic compounds such as organochlorine pesticides, organophosphorus pesticides and substituted benzene compounds were studied.

2,959 citations

Journal ArticleDOI
TL;DR: It is concluded that when nonmonotonic dose-response curves occur, the effects of low doses cannot be predicted by the effects observed at high doses, and fundamental changes in chemical testing and safety determination are needed to protect human health.
Abstract: For decades, studies of endocrine-disrupting chemicals (EDCs) have challenged traditional concepts in toxicology, in particular the dogma of “the dose makes the poison,” because EDCs can have effects at low doses that are not predicted by effects at higher doses. Here, we review two major concepts in EDC studies: low dose and nonmonotonicity. Low-dose effects were defined by the National Toxicology Program as those that occur in the range of human exposures or effects observed at doses below those used for traditional toxicological studies. We review the mechanistic data for low-dose effects and use a weight-of-evidence approach to analyze five examples from the EDC literature. Additionally, we explore nonmonotonic dose-response curves, defined as a nonlinear relationship between dose and effect where the slope of the curve changes sign somewhere within the range of doses examined. We provide a detailed discussion of the mechanisms responsible for generating these phenomena, plus hundreds of examples from...

2,475 citations

Journal ArticleDOI
23 Sep 2011-Thyroid
TL;DR: The revised guidelines for the management of thyroid disease in pregnancy include recommendations regarding the interpretation of thyroid function tests in pregnancy, iodine nutrition, thyroid autoantibodies and pregnancy complications, thyroid considerations in infertile women, hypothyroidism in pregnancy and thyrotoxicosis in pregnancy.
Abstract: Background: Thyroid disease in pregnancy is a common clinical problem. Since the guidelines for the management of these disorders by the American Thyroid Association (ATA) were first published in 2...

2,409 citations