scispace - formally typeset
Search or ask a question
Author

R. Fukuda

Bio: R. Fukuda is an academic researcher from Hiroshima University. The author has contributed to research in topics: Dentin & Dental bonding. The author has an hindex of 4, co-authored 4 publications receiving 1192 citations.

Papers
More filters
Journal ArticleDOI
TL;DR: Besides self-etching dentin, specific functional monomers have additional chemical bonding efficacy that is expected to contribute to their adhesive potential to tooth tissue.
Abstract: Mild self-etch adhesives demineralize dentin only partially, leaving hydroxyapatite around collagen within a submicron hybrid layer. We hypothesized that this residual hydroxyapatite may serve as a receptor for chemical interaction with the functional monomer and, subsequently, contribute to adhesive performance in addition to micro-mechanical hybridization. We therefore chemically characterized the adhesive interaction of 3 functional monomers with synthetic hydroxyapatite, using x-ray photoelectron spectroscopy and atomic absorption spectrophotometry. We further characterized their interaction with dentin ultra-morphologically, using transmission electron microscopy. The monomer 10-methacryloxydecyl dihydrogen phosphate (10-MDP) readily adhered to hydroxyapatite. This bond appeared very stable, as confirmed by the low dissolution rate of its calcium salt in water. The bonding potential of 4-methacryloxyethyl trimellitic acid (4-MET) was substantially lower. The monomer 2-methacryloxyethyl phenyl hydrogen phosphate (phenyl-P) and its bond to hydroxyapatite did not appear to be hydrolytically stable. Besides self-etching dentin, specific functional monomers have additional chemical bonding efficacy that is expected to contribute to their adhesive potential to tooth tissue.

1,035 citations

Journal ArticleDOI
TL;DR: The present findings indicate that the molecular structure of the polyalkenoic acid significantly influences the chemical bonding efficacy to Hap-based substrates.

100 citations

Journal ArticleDOI
TL;DR: It is concluded that the self-adhesiveness of RMGIs should be attributed to ionic bonding to hydroxyapatite around collagen, and to micro-mechanical interlocking for those R MGIs that additionally hybridize dentin.
Abstract: Ionic bonding between polyalkenoic acid and hydroxyapatite may explain the excellent bonding retention of glass-ionomers in clinical trials. We have here investigated the extent to which the self-adhesiveness of resin-modified glass-ionomers (RMGIs) can be attributed to this chemical bonding capacity. Therefore, the interaction of 3 RMGIs with tooth substrates was comprehensively characterized, with electron and atomic force microscopy correlated with x-ray photoelectron spectroscopy (XPS). Interfacial ultrastructural analysis for 2 RMGIs disclosed a shallow hybridization of hydroxyapatite-coated collagen, on which a submicron gel phase was deposited through reaction of the polyalkenoic acid with calcium extracted from the dentin surface. One RMGI, however, bonded to dentin without hybrid layer or gel phase formation. XPS indicated that polycarboxylic acids included in the RMGIs electrostatically interacted with hydroxyapatite. We conclude that the self-adhesiveness of RMGIs should be attributed to ionic bonding to hydroxyapatite around collagen, and to micro-mechanical interlocking for those RMGIs that additionally hybridize dentin.

87 citations

Journal ArticleDOI
TL;DR: XPS spectra of HAp treated with 4-MET disclosed the surface to be enriched in calcium and decreased in phosphorus, indicating that phosphorus was extracted at a relatively higher rate than calcium.
Abstract: Each dental adhesive contains a specific functional monomer that determines its actual adhesive performance to tooth tissue. 4-methacryloxyethyl trimellitic acid (4-MET) is well-known as one of the functional monomers mostly available and consequently widely used in commercial adhesives. We therefore characterized the chemical interaction of 4-MET with hydroxyapatite (HAp) using X-ray Photoelectron Spectroscopy (XPS). XPS revealed that the peak representing -COO- of 4-MET shifted to a lower binding energy, when 4-MET was adsorbed onto HAp. Deconvolution of this shifted peak disclosed two components with a peak representing unreacted carboxyl groups and ester groups, and a peak suggesting chemical bonding of other carboxyl groups to Ca of HAp. XPS spectra of HAp treated with 4-MET also disclosed the surface to be enriched in calcium and decreased in phosphorus, indicating that phosphorus was extracted at a relatively higher rate than calcium. It can thus be concluded that true chemical bonding of 4-MET with calcium present in HAp occurred, as it was proven using XPS.

63 citations


Cited by
More filters
Journal ArticleDOI
TL;DR: This paper critically appraises methodologies that focus on chemical degradation patterns of hydrolysis and elution of interface components, as well as mechanically oriented test set-ups, such as fatigue and fracture toughness measurements, to assess adhesion durability.
Abstract: The immediate bonding effectiveness of contemporary adhesives is quite favorable, regardless of the approach used. In the long term, the bonding effectiveness of some adhesives drops dramatically, whereas the bond strengths of other adhesives are more stable. This review examines the fundamental processes that cause the adhesion of biomaterials to enamel and dentin to degrade with time. Non-carious class V clinical trials remain the ultimate test method for the assessment of bonding effectiveness, but in addition to being high-cost, they are time- and labor-consuming, and they provide little information on the true cause of clinical failure. Therefore, several laboratory protocols were developed to predict bond durability. This paper critically appraises methodologies that focus on chemical degradation patterns of hydrolysis and elution of interface components, as well as mechanically oriented test set-ups, such as fatigue and fracture toughness measurements. A correlation of in vitro and in vivo data revealed that, currently, the most validated method to assess adhesion durability involves aging of micro-specimens of biomaterials bonded to either enamel or dentin. After about 3 months, all classes of adhesives exhibited mechanical and morphological evidence of degradation that resembles in vivo aging effects. A comparison of contemporary adhesives revealed that the three-step etch-and-rinse adhesives remain the 'gold standard' in terms of durability. Any kind of simplification in the clinical application procedure results in loss of bonding effectiveness. Only the two-step self-etch adhesives approach the gold standard and do have some additional clinical benefits.

1,778 citations

Journal Article
TL;DR: The basic bonding mechanism to enamel and dentin of these three approaches is demonstrated by means of ultramorphological and chemical characterization of tooth-biomaterial interfacial interactions and confirms that conventional three-step etch&rinse adhesives still perform most favorably and are most reliable in the long-term.
Abstract: Bonding to tooth tissue can be achieved through an "etch&rinse," "self-etch" or "glass-ionomer" approach. In this paper, the basic bonding mechanism to enamel and dentin of these three approaches is demonstrated by means of ultramorphological and chemical characterization of tooth-biomaterial interfacial interactions. Furthermore, bond-strength testing and measurement of marginal-sealing effectiveness (the two most commonly employed methodologies to determine "bonding effectiveness" in the laboratory) are evaluated upon their value and relevance in predicting clinical performance. A new dynamic methodology to test biomaterial-tooth bonds in a fatigue mode is introduced with a recently developed micro-rotary fatigue-testing device. Eventually, today's adhesives will be critically weighted upon their performance in diverse laboratory studies and clinical trials. Special attention has been given to the benefits/drawbacks of an etch&rinse versus a self-etch approach and the long-term performance of these adhesives. Correlating data gathered in the laboratory with clinical results clearly showed that laboratory research CAN predict clinical effectiveness. Although there is a tendency to simplify bonding procedures, the data presented confirm that conventional three-step etch&rinse adhesives still perform most favorably and are most reliable in the long-term. Nevertheless, a self-etch approach may have the best future perspective. Clinically, when adhesives no longer require an "etch&rinse" step, the application time, and probably more importantly, the technique-sensitivity are substantially reduced. Especially "mild," two-step self-etch adhesives that bond through a combined micromechanical and chemical interaction with tooth tissue closely approach conventional three-step systems in bonding performance.

1,721 citations

Journal ArticleDOI
TL;DR: The aim of this article is to systematically review the ingredients commonly used in current dental adhesives as well as the properties of these ingredients.

1,218 citations

Journal ArticleDOI
TL;DR: This study critically discusses the latest peer-reviewed reports related to formation, aging and stability of resin bonding, focusing on the micro and nano-phenomena related to adhesive interface degradation.

1,086 citations

Journal ArticleDOI
TL;DR: The major shortcomings of the most simple-to-use one-step (self-etch) adhesives are addressed and special attention is devoted to the AD-concept and the benefit of chemical interfacial interaction with regard to bond durability.

1,059 citations