scispace - formally typeset
Search or ask a question
Author

Ramon Pallas-Areny

Other affiliations: University of Wisconsin-Madison
Bio: Ramon Pallas-Areny is an academic researcher from Polytechnic University of Catalonia. The author has contributed to research in topics: Common-mode rejection ratio & Amplifier. The author has an hindex of 29, co-authored 139 publications receiving 3658 citations. Previous affiliations of Ramon Pallas-Areny include University of Wisconsin-Madison.


Papers
More filters
Book
17 Aug 1993
TL;DR: Signal Conditioning for Resistive Sensors Reactance Variation and Electromagnetic Sensors and Signals for Self-Generating Sensors Signal conditioning for self-Generation Sensors Digital Sensors Telemetry and Data Acquisition.
Abstract: Resistive Sensors Signal Conditioning for Resistive Sensors Reactance Variation and Electromagnetic Sensors Signal Conditioning for Reactance Variation Sensors Generating Sensors Signal Conditioning for Self-Generating Sensors Digital Sensors Other Sensing Methods Telemetry and Data Acquisition General Bibliography Appendix Index.

432 citations

Journal ArticleDOI
TL;DR: The impedance of skin coated with gel but otherwise unprepared was measured at ten sites on the thorax, leg, and forehead of ten subjects, which suggests that the variation in skin impedance can cause errors in two-electrode electrical impedance tomographs.
Abstract: The impedance of skin coated with gel but otherwise unprepared was measured from 1 Hz to 1 MHz at ten sites on the thorax, leg, and forehead of ten subjects. For a 1-cm/sup 2/ area, the 1 Hz impedance varied from 10 k Omega to 1 M Omega , which suggests that the bipotential amplifier input impedance should be very high to avoid common-mode-to-differential-mode voltage conversion. The 1-MHz impedance was tightly clustered about 120 Omega . The 100-kHz impedance was about 220 Omega , which suggests that the variation in skin impedance can cause errors in two-electrode electrical impedance tomographs. >

364 citations

Journal ArticleDOI
TL;DR: A novel balanced input ac-coupling network that provides a bias path without any connection to ground, thus resulting in a high CMRR and allows the implementation of high-gain biopotential amplifiers with a reduced number of parts, Thus resulting in low power consumption.
Abstract: AC coupling is essential in biopotential measurements. Electrode offset potentials can be several orders of magnitude larger than the amplitudes of the biological signals of interest, thus limiting the admissible gain of a dc-coupled front end to prevent amplifier saturation. A high-gain input stage needs ac input coupling. This can be achieved by series capacitors, but in order to provide a bias path, grounded resistors are usually included, which degrade the common mode rejection ratio (CMRR). This paper proposes a novel balanced input ac-coupling network that provides a bias path without any connection to ground, thus resulting in a high CMRR. The circuit being passive, it does not limit the differential dc input voltage. Furthermore, differential signals are ac coupled, whereas common-mode voltages are dc coupled, thus allowing the closed-loop control of the dc common mode voltage by means of a driven-right-leg circuit. This makes the circuit compatible with common-mode dc shifting strategies intended for single-supply biopotential amplifiers. The proposed circuit allows the implementation of high-gain biopotential amplifiers with a reduced number of parts, thus resulting in low power consumption. An electrocardiogram amplifier built according to the proposed design achieves a CMRR of 123 dB at 50 Hz.

213 citations

Journal ArticleDOI
TL;DR: A vehicle detector which includes a magnetic and an optical sensor and is intended as sensor node for use with a WSN, combined with power-efficient event-based software is presented.
Abstract: Vehicle detectors provide essential information about parking occupancy and traffic flow. To cover large areas that lack a suitable electrical infrastructure, wired sensors networks are impractical because of their high deployment and maintenance costs. Wireless sensor networks (WSNs) with autonomous sensor nodes can be more economical. Vehicle detectors intended for a WSN should be small, sturdy, low power, cost-effective, and easy to install and maintain. Currently available vehicle detectors based on inductive loops, ultrasound, infrared, or magnetic sensors do not fulfill the requirements above, which has led to the search for alternative solutions. This paper presents a vehicle detector which includes a magnetic and an optical sensor and is intended as sensor node for use with a WSN. Magnetic sensors based on magnetoresistors are very sensitive and can detect the magnetic anomaly in the Earth's magnetic field that results from the presence of a car, but their continuous operation would drain more than 1.5 mA at 3 V, hence limiting the autonomy of a battery-supplied sensor node. Passive, low-power optical sensors can detect the shadow cast by car that covers them, but are prone to false detections. The use of optical triggering to wake-up a magnetic sensor, combined with power-efficient event-based software, yields a simple, compact, reliable, low-power sensor node for vehicle detection whose quiescent current drain is 5.5 μA. This approach of using a low-power sensor to trigger a second more specific sensor can be applied to other autonomous sensor nodes.

154 citations

Book
01 Jan 1999
TL;DR: This book discusses signals and Signal Processing, including AC/DC Signal Conversion, Analog Signal Switching, Multiplexing and Sampling, and more.
Abstract: Signals and Signal Processing. Voltage Amplification. Current-to-Voltage and Voltage-to-Current Conversion. Linear Analog Functions. AC/DC Signal Conversion. Other Nonlinear Analog Functions. Analog Signal Filtering. Analog Signal Switching, Multiplexing and Sampling. Error Analysis and Reduction. Interference and Its Reduction. Noise, Drift and Their Reduction. Appendices. Index.

145 citations


Cited by
More filters
Journal ArticleDOI
TL;DR: A survey of the work in electrical impedance tomography can be found in this article, where the authors survey some of the most important works in the field. Butt.t.
Abstract: t. This paper surveys some of the work our group has done in electrical impedance tomography.

1,726 citations

Journal Article
TL;DR: This study is the first to establish reference and normal values for PWV, combining a sizeable European population after standardizing results for different methods of PWV measurement.
Abstract: Aims Carotid–femoral pulse wave velocity (PWV), a direct measure of aortic stiffness, has become increasingly important for total cardiovascular (CV) risk estimation. Its application as a routine tool for clinical patient evaluation has been hampered by the absence of reference values. The aim of the present study is to establish reference and normal values for PWV based on a large European population. Methods and results We gathered data from 16 867 subjects and patients from 13 different centres across eight European countries, in which PWV and basic clinical parameters were measured. Of these, 11 092 individuals were free from overt CV disease, non-diabetic and untreated by either anti-hypertensive or lipid-lowering drugs and constituted the reference value population, of which the subset with optimal/normal blood pressures (BPs) (n = 1455) is the normal value population. Prior to data pooling, PWV values were converted to a common standard using established conversion formulae. Subjects were categorized by age decade and further subdivided according to BP categories. Pulse wave velocity increased with age and BP category; the increase with age being more pronounced for higher BP categories and the increase with BP being more important for older subjects. The distribution of PWV with age and BP category is described and reference values for PWV are established. Normal values are proposed based on the PWV values observed in the non-hypertensive subpopulation who had no additional CV risk factors. Conclusion The present study is the first to establish reference and normal values for PWV, combining a sizeable European population after standardizing results for different methods of PWV measurement.

1,371 citations

Journal ArticleDOI
TL;DR: A physiological signal-based emotion recognition system is reported, developed to operate as a user-independent system, based on physiological signal databases obtained from multiple subjects, and consisted of preprocessing, feature extraction and pattern classification stages.
Abstract: A physiological signal-based emotion recognition system is reported. The system was developed to operate as a user-independent system, based on physiological signal databases obtained from multiple subjects. The input signals were electrocardiogram, skin temperature variation and electrodermal activity, all of which were acquired without much discomfort from the body surface, and can reflect the influence of emotion on the autonomic nervous system. The system consisted of preprocessing, feature extraction and pattern classification stages. Preprocessing and feature extraction methods were devised so that emotion-specific characteristics could be extracted from short-segment signals. Although the features were carefully extracted, their distribution formed a classification problem, with large overlap among clusters and large variance within clusters. A support vector machine was adopted as a pattern classifier to resolve this difficulty. Correct-classification ratios for 50 subjects were 78.4% and 61.8%, for the recognition of three and four categories, respectively.

903 citations

Journal ArticleDOI
TL;DR: This paper explores the use of dry/noncontact electrodes for clinical use by first explaining the electrical models for dry, insulated and noncontact electrodes and show the performance limits, along with measured data and an extensive review of the latest dry electrode developments in the literature.
Abstract: Recent demand and interest in wireless, mobile-based healthcare has driven significant interest towards developing alternative biopotential electrodes for patient physiological monitoring. The conventional wet adhesive Ag/AgCl electrodes used almost universally in clinical applications today provide an excellent signal but are cumbersome and irritating for mobile use. While electrodes that operate without gels, adhesives and even skin contact have been known for many decades, they have yet to achieve any acceptance for medical use. In addition, detailed knowledge and comparisons between different electrodes are not well known in the literature. In this paper, we explore the use of dry/noncontact electrodes for clinical use by first explaining the electrical models for dry, insulated and noncontact electrodes and show the performance limits, along with measured data. The theory and data show that the common practice of minimizing electrode resistance may not always be necessary and actually lead to increased noise depending on coupling capacitance. Theoretical analysis is followed by an extensive review of the latest dry electrode developments in the literature. The paper concludes with highlighting some of the novel systems that dry electrode technology has enabled for cardiac and neural monitoring followed by a discussion of the current challenges and a roadmap going forward.

879 citations

Journal ArticleDOI
11 Aug 1995-Science
TL;DR: Low-frequency ultrasound was shown to increase the permeability of human skin to many drugs, including high molecular weight proteins, by several orders of magnitude, thus making transdermal administration of these molecules potentially feasible.
Abstract: Transdermal drug delivery offers a potential method of drug administration. However, its application has been limited to a few low molecular weight compounds because of the extremely low permeability of human skin. Low-frequency ultrasound was shown to increase the permeability of human skin to many drugs, including high molecular weight proteins, by several orders of magnitude, thus making transdermal administration of these molecules potentially feasible. It was possible to deliver and control therapeutic doses of proteins such as insulin, interferon gamma, and erythropoeitin across human skin. Low-frequency ultrasound is thus a potential noninvasive substitute for traditional methods of drug delivery, such as injections.

803 citations