scispace - formally typeset
Search or ask a question
Author

Reid R. Harrison

Bio: Reid R. Harrison is an academic researcher from University of Utah. The author has contributed to research in topics: Amplifier & Integrated circuit. The author has an hindex of 25, co-authored 70 publications receiving 3858 citations.


Papers
More filters
Journal ArticleDOI
26 Dec 2006
TL;DR: A prototype integrated circuit for wireless neural recording from a 100-channel microelectrode array was developed and a two-chip system was used to record neural signals from a Utah Electrode Array in cat cortex and transmit the digitized signals wirelessly to a receiver.
Abstract: Recent work in field of neuroprosthetics has demonstrated that by observing the simultaneous activity of many neurons in specific regions of the brain, it is possible to produce control signals that allow animals or humans to drive cursors or prosthetic limbs directly through thoughts. As neuroprosthetic devices transition from experimental to clinical use, there is a need for fully-implantable amplification and telemetry electronics in close proximity to the recording sites. To address these needs, we developed a prototype integrated circuit for wireless neural recording from a 100-channel microelectrode array. The design of both the system-level architecture and the individual circuits were driven by severe power constraints for small implantable devices; chronically heating tissue by only a few degrees Celsius leads to cell death. Due to the high data rate produced by 100 neural signals, the system must perform data reduction as well. We use a combination of a low-power ADC and an array of "spike detectors" to reduce the transmitted data rate while preserving critical information. The complete system receives power and commands (at 6.5 kb/s) wirelessly over a 2.64-MHz inductive link and transmits neural data back at a data rate of 330 kb/s using a fully-integrated 433-MHz FSK transmitter. The 4.7times5.9 mm2 chip was fabricated in a 0.5-mum 3M2P CMOS process and consumes 13.5 mW of power. While cross-chip interference limits performance in single-chip operation, a two-chip system was used to record neural signals from a Utah Electrode Array in cat cortex and transmit the digitized signals wirelessly to a receiver

927 citations

Proceedings ArticleDOI
07 Aug 2002
TL;DR: A novel bioamplifier that uses a MOS-bipolar pseudo-resistor to amplify signals down to the mHz range while rejecting large dc offsets and it is demonstrated that the VLSI implementation approaches the theoretical noise-power tradeoff limit.
Abstract: There is a need among scientists and clinicians for low-noise, low-power biosignal amplifiers capable of amplifying signals in the mHz to kHz range while rejecting large dc offsets generated at the electrode-tissue interface. The advent of fully-implantable multielectrode arrays has created the need for fully-integrated micropower amplifiers. We designed and tested a novel bioamplifier that uses a MOS-bipolar pseudo-resistor to amplify signals down to the mHz range while rejecting large dc offsets. We derive the theoretical noise-power tradeoff limit - the noise efficiency factor - for this amplifier and demonstrate that our VLSI implementation approaches that limit. The resulting amplifier, built in a standard 1.5/spl mu/m CMOS process, passes signals from 0.1mHz to 7.2kHz with an input-referred noise of 2.2/spl mu/Vrms and a power dissipation of 80/spl mu/W while consuming 0.16mm/sup 2/ of chip area.

489 citations

Proceedings ArticleDOI
27 May 2007
TL;DR: A new, complete expression for total power link efficiency is introduced for planar spiral "pancake" coils at low RF frequencies (100 kHz -10 MHz) to consider practical design constraints such as component variation, power amplifier limitations, and coil voltage limits.
Abstract: Due to limited battery life and size limitations, many implantable biomedical devices must be powered inductively. Because of weak coupling between implanted and external coils, obtaining high power efficiency is a challenge. Previous authors have addressed the issue of optimizing power efficiency in these systems. In this paper, we further this analysis for the case of planar spiral "pancake" coils at low RF frequencies (100 kHz -10 MHz). We consider practical design constraints such as component variation, power amplifier limitations, and coil voltage limits. We introduce a new, complete expression for total power link efficiency.

277 citations

Journal ArticleDOI
02 Jun 2009
TL;DR: benchtop and in vivo experimental results from an integrated circuit designed for wireless implantable neural recording applications, which was fabricated in a commercially available 0.6- mum 2P3M BiCMOS process, are presented.
Abstract: We present benchtop and in vivo experimental results from an integrated circuit designed for wireless implantable neural recording applications. The chip, which was fabricated in a commercially available 0.6- mum 2P3M BiCMOS process, contains 100 amplifiers, a 10-bit analog-to-digital converter (ADC), 100 threshold-based spike detectors, and a 902-928 MHz frequency-shift-keying (FSK) transmitter. Neural signals from a selected amplifier are sampled by the ADC at 15.7 kSps and telemetered over the FSK wireless data link. Power, clock, and command signals are sent to the chip wirelessly over a 2.765-MHz inductive (coil-to-coil) link. The chip is capable of operating with only two off-chip components: a power/command receiving coil and a 100-nF capacitor.

239 citations

Journal ArticleDOI
TL;DR: An FM transmitter with the lowest power dissipation reported for biosignal telemetry and micropower integrated circuits for recovering clock and data signals over a transcutaneous power link are developed.
Abstract: State-of-the art neural recording systems require electronics allowing for transcutaneous, bidirectional data transfer. As these circuits will be implanted near the brain, they must be small and low power. We have developed micropower integrated circuits for recovering clock and data signals over a transcutaneous power link. The data recovery circuit produces a digital data signal from an ac power waveform that has been amplitude modulated. We have also developed an FM transmitter with the lowest power dissipation reported for biosignal telemetry. The FM transmitter consists of a low-noise biopotential amplifier and a voltage controlled oscillator used to transmit amplified neural signals at a frequency near 433 MHz. All circuits were fabricated in a standard 0.5-/spl mu/m CMOS VLSI process. The resulting chip is powered through a wireless inductive link. The power consumption of the clock and data recovery circuits is measured to be 129 /spl mu/W; the power consumption of the transmitter is measured to be 465 /spl mu/W when using an external surface mount inductor. Using a parasitic antenna less than 2 mm long, a received power level was measured to be -59.73 dBm at a distance of one meter.

174 citations


Cited by
More filters
Journal ArticleDOI
06 Jun 1986-JAMA
TL;DR: The editors have done a masterful job of weaving together the biologic, the behavioral, and the clinical sciences into a single tapestry in which everyone from the molecular biologist to the practicing psychiatrist can find and appreciate his or her own research.
Abstract: I have developed "tennis elbow" from lugging this book around the past four weeks, but it is worth the pain, the effort, and the aspirin. It is also worth the (relatively speaking) bargain price. Including appendixes, this book contains 894 pages of text. The entire panorama of the neural sciences is surveyed and examined, and it is comprehensive in its scope, from genomes to social behaviors. The editors explicitly state that the book is designed as "an introductory text for students of biology, behavior, and medicine," but it is hard to imagine any audience, interested in any fragment of neuroscience at any level of sophistication, that would not enjoy this book. The editors have done a masterful job of weaving together the biologic, the behavioral, and the clinical sciences into a single tapestry in which everyone from the molecular biologist to the practicing psychiatrist can find and appreciate his or

7,563 citations

Proceedings Article
01 Jan 1989
TL;DR: A scheme is developed for classifying the types of motion perceived by a humanlike robot and equations, theorems, concepts, clues, etc., relating the objects, their positions, and their motion to their images on the focal plane are presented.
Abstract: A scheme is developed for classifying the types of motion perceived by a humanlike robot. It is assumed that the robot receives visual images of the scene using a perspective system model. Equations, theorems, concepts, clues, etc., relating the objects, their positions, and their motion to their images on the focal plane are presented. >

2,000 citations

Journal ArticleDOI
TL;DR: In this article, a low-noise low-power biosignal amplifiers capable of amplifying signals in the millihertz-to-kilohertz range while rejecting large dc offsets generated at the electrode-tissue interface is presented.
Abstract: There is a need among scientists and clinicians for low-noise low-power biosignal amplifiers capable of amplifying signals in the millihertz-to-kilohertz range while rejecting large dc offsets generated at the electrode-tissue interface. The advent of fully implantable multielectrode arrays has created the need for fully integrated micropower amplifiers. We designed and tested a novel bioamplifier that uses a MOS-bipolar pseudoresistor element to amplify low-frequency signals down to the millihertz range while rejecting large dc offsets. We derive the theoretical noise-power tradeoff limit - the noise efficiency factor - for this amplifier and demonstrate that our VLSI implementation approaches this limit by selectively operating MOS transistors in either weak or strong inversion. The resulting amplifier, built in a standard 1.5-/spl mu/m CMOS process, passes signals from 0.025Hz to 7.2 kHz with an input-referred noise of 2.2 /spl mu/Vrms and a power dissipation of 80 /spl mu/W while consuming 0.16 mm/sup 2/ of chip area. Our design technique was also used to develop an electroencephalogram amplifier having a bandwidth of 30 Hz and a power dissipation of 0.9 /spl mu/W while maintaining a similar noise-power tradeoff.

1,572 citations

Journal ArticleDOI
TL;DR: An ethologically-inspired view of interactive behavior as simultaneous processes that specify potential motor actions and select between them is discussed, and how recent neurophysiological data from diverse cortical and subcortical regions appear more compatible with this parallel view than with the classical view of serial information processing stages.
Abstract: The neural bases of behavior are often discussed in terms of perceptual, cognitive, and motor stages, defined within an information processing framework that was originally inspired by models of human abstract problem solving. Here, we review a growing body of neurophysiological data that is difficult to reconcile with this influential theoretical perspective. As an alternative foundation for interpreting neural data, we consider frameworks borrowed from ethology, which emphasize the kinds of real-time interactive behaviors that animals have engaged in for millions of years. In particular, we discuss an ethologically-inspired view of interactive behavior as simultaneous processes that specify potential motor actions and select between them. We review how recent neurophysiological data from diverse cortical and subcortical regions appear more compatible with this parallel view than with the classical view of serial information processing stages.

1,267 citations

Journal ArticleDOI
04 Apr 2014-Science
TL;DR: Experimental and theoretical approaches for using ideas in soft microfluidics, structured adhesive surfaces, and controlled mechanical buckling to achieve ultralow modulus, highly stretchable systems that incorporate assemblies of high-modulus, rigid, state-of-the-art functional elements are described.
Abstract: When mounted on the skin, modern sensors, circuits, radios, and power supply systems have the potential to provide clinical-quality health monitoring capabilities for continuous use, beyond the confines of traditional hospital or laboratory facilities. The most well-developed component technologies are, however, broadly available only in hard, planar formats. As a result, existing options in system design are unable to effectively accommodate integration with the soft, textured, curvilinear, and time-dynamic surfaces of the skin. Here, we describe experimental and theoretical approaches for using ideas in soft microfluidics, structured adhesive surfaces, and controlled mechanical buckling to achieve ultralow modulus, highly stretchable systems that incorporate assemblies of high-modulus, rigid, state-of-the-art functional elements. The outcome is a thin, conformable device technology that can softly laminate onto the surface of the skin to enable advanced, multifunctional operation for physiological monitoring in a wireless mode.

975 citations