scispace - formally typeset
Search or ask a question
Author

Roger C. Dugan

Bio: Roger C. Dugan is an academic researcher from Electric Power Research Institute. The author has contributed to research in topics: Distributed generation & Smart grid. The author has an hindex of 28, co-authored 78 publications receiving 6048 citations.


Papers
More filters
Book
01 Oct 1995
TL;DR: In this paper, the authors present a power quality evaluation procedure for the purpose of measuring the power quality of a power supply. But, they do not define the specific classes of power quality problems.
Abstract: CHAPTER 1: INTRODUCTION What is Power Quality? Power Quality -- Voltage Quality Why Are We Concerned About Power Quality? The Power Quality Evaluation Procedure Who Should Use This Book Overview of the Contents CHAPTER 2: TERMS AND DEFINITIONS Need for a Consistent Vocabulary General Classes of Power Quality Problems Transients Long-Duration Voltage Variations Short-Duration Voltage Variations Voltage Imbalance Waveform Distortion Voltage Fluctuation Power Frequency Variations Power Quality Terms Ambiguous Terms CBEMA and ITI Curves References CHAPTER 3: VOLTAGE SAGS AND INTERRUPTIONS Sources of Sags and Interruptions Estimating Voltage Sag Performance Fundamental Principles of Protection Solutions at the End-User Level Evaluating the Economics of Different Ride-Through Alternatives Motor-Starting Sags Utility System Fault-Clearing Issues References CHAPTER 4: TRANSIENT OVERVOLTAGES Sources of Transient Overvoltages Principles of Overvoltage Protection Devices for Overvoltage Protection Utility Capacitor-Switching Transients Utility System Lightning Protection Managing Ferroresonance Switching Transient Problems with Loads Computer Tools for Transients Analysis References CHAPTER 5: FUNDAMENTALS OF HARMONICS Harmonic Distortion Voltage versus Current Distortion Harmonics versus Transients Harmonic Indexes Harmonic Sources from Commercial Loads Harmonic Sources from Industrial Loads Locating Harmonic Sources System Response Characteristics Effects of Harmonic Distortion Interharmonics References Bibliography CHAPTER 6: APPLIED HARMONICS Harmonic Distortion Evaluations Principles for Controlling Harmonics Where to Control Harmonics Harmonic Studies Devices for Controlling Harmonic Distortion Harmonic Filter Design: A Case Study Case Studies Standards of Harmonics References Bibliography CHAPTER 7: LONG-DURATION VOLTAGE VARIATIONS Principles of Regulating the Voltage Devices for Voltage Regulation Utility Voltage Regulator Application Capacitors for Voltage Regulation End-User Capacitor Application Regulating Utility Voltage with Distributed Resources Flicker References Bibliography CHAPTER 8: POWER QUALITY BENCHMARKING Introduction Benchmarking Process RMS Voltage Variation Indices Harmonics Indices Power Quality Contracts Power Quality Insurance Power Quality State Estimation Including Power Quality in Distribution Planning References Bibliography CHAPTER 9: DISTRIBUTED GENERATION AND POWER QUALITY Resurgence of DG DG Technologies Interface to the Utility System Power Quality Issues Operating Conflicts DG on Distribution Networks Siting DGDistributed Generation Interconnection Standards Summary References Bibliography CHAPTER 10: WIRING AND GROUNDING Resources Definitions Reasons for Grounding Typical Wiring and Grounding Problems Solutions to Wiring and Grounding Problems Bibliography CHAPTER 11: POWER QUALITY MONITORING Monitoring Considerations Historical Perspective of Power Quality Measuring Instruments Power Quality Measurement Equipment Assessment of Power Quality Measurement Data Application of Intelligent Systems Power Quality Monitoring Standards References Index INDEX

1,991 citations

Journal ArticleDOI
TL;DR: Several system issues which may be encountered as DR penetrates into distribution systems are discussed, including vulnerability and overvoltages due to islanding and coordination with reclosing, system restoration and network issues.
Abstract: Because traditional electric power distribution systems have been designed assuming the primary substation is the sole source of power and short-circuit capacity, DR interconnection results in operating situations that do not occur in a conventional system. This paper discusses several system issues which may be encountered as DR penetrates into distribution systems. The voltage issues covered are the DR impact on system voltage, interaction of DR and capacitor operations, and interaction of DR and voltage regulator and LTC operations. Protection issues include fuse coordination, feeding faults after utility protection opens, impact of DR on interrupting rating of devices, faults on adjacent feeders, fault detection, ground source impacts, single phase interruption on three phase line, recloser coordination and conductor burndown. Loss of power grid is also discussed, including vulnerability and overvoltages due to islanding and coordination with reclosing. Also covered separately are system restoration and network issues.

939 citations

Journal Article
TL;DR: In this article, the emphasis is on distributed generators that are interconnected to with utility distribution systems, which are referred to as distributed generation (DG) and are typically no larger than 1 or 2 MW.
Abstract: The emphasis of this article is on distributed generators that are interconnected to with utility distribution systems. These will generally be units smaller than 10 MW. Larger units are generally connected directly to transmission facilities and will most likely be commercial power producers. The units installed on distribution systems will typically be no larger than 1 or 2 MW. These would be installed mostly by the utility itself or by end users. This method of generation is commonly referred to as "distributed generation" (DG).

480 citations

Journal ArticleDOI
TL;DR: For nearly 20 years, the Test Feeder Working Group of the Distribution System Analysis Subcommittee has been developing openly available distribution test feeders for use by researchers as discussed by the authors, providing models of distribution systems that reflect the wide diversity in design and their various analytic challenges.
Abstract: For nearly 20 years, the Test Feeder Working Group of the Distribution System Analysis Subcommittee has been developing openly available distribution test feeders for use by researchers. The purpose of these test feeders is to provide models of distribution systems that reflect the wide diversity in design and their various analytic challenges. Because of their utility and accessibility, the test feeders have been used for a wide range of research, some of which has been outside the original scope of intended uses. This paper provides an overview of the existing distribution feeder models and clarifies the specific analytic challenges that they were originally designed to examine. Additionally, this paper will provide guidance on which feeders are best suited for various types of analysis. The purpose of this paper is to provide the original intent of the Working Group and to provide the information necessary so that researchers may make an informed decision on which of the test feeders are most appropriate for their work.

412 citations

Proceedings ArticleDOI
24 Jul 2011
TL;DR: An open-source distribution system simulator has been developed for distributed resource planning, harmonic studies, neutral-earth voltage studies, volt-var control studies, and other special applications.
Abstract: An open-source distribution system simulator has been developed for distributed resource planning, harmonic studies, neutral-earth voltage studies, volt-var control studies, and other special applications. The software includes several means of interfacing user code, including compiled dynamic link library, COM automation, and text scripting. Co-simulation interfaces are under development for interfacing with proprietary vendor-supplied models, and communication system overlays. The simulator, called OpenDSS, has been used to conduct several smart grid research projects, including advanced automation, electric vehicle penetration, state estimation, and green circuits. The software architecture and solution methods are described, in the effort to foster more collaborative research.

374 citations


Cited by
More filters
Journal ArticleDOI
TL;DR: This paper presents an exhaustive review of three-phase improved power quality AC-DC converters configurations, control strategies, selection of components, comparative factors, recent trends, their suitability, and selection for specific applications.
Abstract: Solid-state switch-mode rectification converters have reached a matured level for improving power quality in terms of power-factor correction (PFC), reduced total harmonic distortion at input AC mains and precisely regulated DC output in buck, boost, buck-boost and multilevel modes with unidirectional and bidirectional power flow. This paper deals with a comprehensive review of improved power quality converters (IPQCs) configurations, control approaches, design features, selection of components, other related considerations, and their suitability and selection for specific applications. It is targeted to provide a wide spectrum on the status of IPQC technology to researchers, designers and application engineers working on switched-mode AC-DC converters. A classified list of more than 450 research publications on the state of art of IPQC is also given for a quick reference.

1,691 citations

Journal ArticleDOI
TL;DR: In this paper, the authors start from the observation that there is a renewed interest in small-scale electricity generation and then move on with a discussion of the major benefits and issues of Small-Scale Electricity Generation.

1,599 citations

Journal ArticleDOI
TL;DR: In this paper, the authors investigated preplanned switching events and fault events that lead to islanding of a distribution subsystem and formation of a micro-grid, and they concluded that an appropriate control strategy for the power electronically interfaced DG unit can ensure stability of the microgrid and maintain voltage quality at designated buses, even during islanding transients.
Abstract: This paper investigates (i) preplanned switching events and (ii) fault events that lead to islanding of a distribution subsystem and formation of a micro-grid. The micro-grid includes two distributed generation (DG) units. One unit is a conventional rotating synchronous machine and the other is interfaced through a power electronic converter. The interface converter of the latter unit is equipped with independent real and reactive power control to minimize islanding transients and maintain both angle stability and voltage quality within the micro-grid. The studies are performed based on a digital computer simulation approach using the PSCAD/EMTDC software package. The studies show that an appropriate control strategy for the power electronically interfaced DG unit can ensure stability of the micro-grid and maintain voltage quality at designated buses, even during islanding transients. This paper concludes that presence of an electronically-interfaced DG unit makes the concept of micro-grid a technically viable option for further investigations.

1,136 citations

Journal ArticleDOI
TL;DR: In this paper, an adaptive decentralized droop controller of paralleled inverter-based distributed generation (DG) units is presented to preserve the power sharing stability, which is based on the static droop characteristics combined with an adaptive transient droop function.
Abstract: This paper addresses the low-frequency relative stability problem in paralleled inverter-based distributed generation (DG) units in microgrids. In the sense of the small-signal dynamics of a microgrid, it can be shown that as the demanded power of each inverter changes, the low-frequency modes of the power sharing dynamics drift to new locations and the relative stability is remarkably affected, and eventually, instability can be yielded. To preserve the power sharing stability, an adaptive decentralized droop controller of paralleled inverter-based DG units is presented in this paper. The proposed power sharing strategy is based on the static droop characteristics combined with an adaptive transient droop function. Unlike conventional droop controllers, which yield 1-DOF tunable controller, the proposed droop controller yields 2-DOF tunable controller. Subsequently, the dynamic performance of the power sharing mechanism can be adjusted, without affecting the static droop gain, to damp the oscillatory modes of the power sharing controller. To account for the power modes immigration at different loading conditions, the transient droop gains are adaptively scheduled via small-signal analysis of the power sharing mechanism along the loading trajectory of each DG unit to yield the desired transient and steady-state response. The gain adaptation scheme utilizes the filtered active and reactive powers as indices; therefore, a stable and smooth power injection performance can be obtained at different loading conditions. The adaptive nature of the proposed controller ensures active damping of power oscillations at different operating conditions, and yields a stable and robust performance of the paralleled inverter system.

1,130 citations

Journal ArticleDOI
TL;DR: In this article, an analytical expression to calculate the optimal size and an effective methodology to identify the corresponding optimum location for DG placement for minimizing the total power losses in primary distribution systems is proposed.

1,060 citations