Sabahudin Hrapovic

Bio: Sabahudin Hrapovic is an academic researcher from National Research Council. The author has contributed to research in topics: Cyclic voltammetry & Carbon nanotube. The author has an hindex of 32, co-authored 45 publications receiving 4706 citations. Previous affiliations of Sabahudin Hrapovic include University College Cork & École Polytechnique de Montréal.


Papers
More filters
Journal ArticleDOI
TL;DR: With glucose oxidase (GOx) as an enzyme model, a GC or carbon fiber microelectrode-based biosensor is constructed that responds even more sensitively to glucose than the GC/GOx electrode modified by Pt nanoparticles or CNTs alone.
Abstract: Platinum nanoparticles with a diameter of 2-3 nm were prepared and used in combination with single-wall carbon nanotubes (SWCNTs) for fabricating electrochemical sensors with remarkably improved sensitivity toward hydrogen peroxide. Nafion, a perfluorosulfonated polymer, was used to solubilize SWCNTs and also displayed strong interactions with Pt nanoparticles to form a network that connected Pt nanoparticles to the electrode surface. TEM and AFM micrographs illustrated the deposition of Pt nanoparticles on carbon nanotubes whereas cyclic voltammetry confirmed an electrical contact through SWCNTs between Pt nanoparticles and the glassy carbon (GC) or carbon fiber backing. With glucose oxidase (GOx) as an enzyme model, we constructed a GC or carbon fiber microelectrode-based biosensor that responds even more sensitively to glucose than the GC/GOx electrode modified by Pt nanoparticles or CNTs alone. The response time and detection limit (S/N = 3) of this biosensor was determined to be 3 s and 0.5 microM, respectively.

987 citations

Journal ArticleDOI
07 Feb 2011-Small
TL;DR: Cellulose nanocrystals have emerged as a new class of nanomaterials for polymer reinforcement and nanocomposite formulation owing to their exceptionally high mechanical strength, low density, chemical tunability, environmental sustainability, and anticipated low cost.
Abstract: Cellulose nanocrystals (CNCs) have emerged as a new class of nanomaterials for polymer reinforcement and nanocomposite formulation owing to their exceptionally high mechanical strength (modulus of 100–140 GPa), low density (1.6 g cm − 3 ), chemical tunability, environmental sustainability, and anticipated low cost. [ 1 ] CNCs have also been fostered for a myriad of applications including enzyme immobilization, [ 2 ]

412 citations

Journal ArticleDOI
TL;DR: As the surface charge of CNC played an important role in cellular uptake and cytotoxicity, facile surface functionalization together with observed noncytotoxicity rendered modified CNC as a promising candidate for bioimaging and drug delivery systems.
Abstract: Probing of cellular uptake and cytotoxicity was conducted for two fluorescent cellulose nanocrystals (CNCs): CNC-fluorescein isothiocyanate (FITC) and newly synthesized CNC-rhodamine B isothiocyanate (RBITC). The positively charged CNC-RBITC was uptaken by human embryonic kidney 293 (HEK 293) and Spodoptera frugiperda (Sf9) cells without affecting the cell membrane integrity. The cell viability assay and cell-based impedance spectroscopy revealed no noticeably cytotoxic effect of the CNC-RBITC conjugate. However, no significant internalization of negatively charged CNC-FITC was observed at physiological pH. Indeed, the effector cells were surrounded by CNC-FITC, leading to eventual cell rupture. As the surface charge of CNC played an important role in cellular uptake and cytotoxicity, facile surface functionalization together with observed noncytotoxicity rendered modified CNC as a promising candidate for bioimaging and drug delivery systems.

283 citations

Journal ArticleDOI
TL;DR: In this paper, Nafion, a perfluorosulfonated polymer, was used to solubilize single-wall carbon nanotubes (SWCNTs) to fabricate electrochemical sensors.

268 citations

Journal ArticleDOI
TL;DR: Among various combinations tested, the most synergistic signal effect was observed for the nanocomposite modified glassy carbon electrode (GC) containing Cu nanoparticles and SWCNT solubilized in Nafion, which provided the best sensitivity for detecting TNT and other nitroaromatic compounds.
Abstract: Metal nanoparticles (Pt, Au, or Cu) together with multiwalled and single-walled carbon nanotubes (MWCNT and SWCNT) solubilized in Nafion have been used to form nanocomposites for electrochemical detection of trinitrotoluene (TNT) and several other nitroaromatics. Electrochemical and surface characterization by cyclic voltammetry, AFM, TEM, SEM, and Raman spectroscopy confirmed the presence of metal nanoparticles on CNTs. Among various combinations tested, the most synergistic signal effect was observed for the nanocomposite modified glassy carbon electrode (GC) containing Cu nanoparticles and SWCNT solubilized in Nafion. This combination provided the best sensitivity for detecting TNT and other nitroaromatic compounds. Adsorptive stripping voltammetry for TNT resulted in a detection limit of 1 ppb, with linearity up to 3 orders of magnitude. Selectivity toward the number and position of the nitro groups in different nitroaromatics was very reproducible and distinct. Reproducibility of the TNT signal was w...

257 citations


Cited by
More filters
Journal ArticleDOI
TL;DR: The advent of AuNP as a sensory element provided a broad spectrum of innovative approaches for the detection of metal ions, small molecules, proteins, nucleic acids, malignant cells, etc. in a rapid and efficient manner.
Abstract: Detection of chemical and biological agents plays a fundamental role in biomedical, forensic and environmental sciences1–4 as well as in anti bioterrorism applications.5–7 The development of highly sensitive, cost effective, miniature sensors is therefore in high demand which requires advanced technology coupled with fundamental knowledge in chemistry, biology and material sciences.8–13 In general, sensors feature two functional components: a recognition element to provide selective/specific binding with the target analytes and a transducer component for signaling the binding event. An efficient sensor relies heavily on these two essential components for the recognition process in terms of response time, signal to noise (S/N) ratio, selectivity and limits of detection (LOD).14,15 Therefore, designing sensors with higher efficacy depends on the development of novel materials to improve both the recognition and transduction processes. Nanomaterials feature unique physicochemical properties that can be of great utility in creating new recognition and transduction processes for chemical and biological sensors15–27 as well as improving the S/N ratio by miniaturization of the sensor elements.28 Gold nanoparticles (AuNPs) possess distinct physical and chemical attributes that make them excellent scaffolds for the fabrication of novel chemical and biological sensors (Figure 1).29–36 First, AuNPs can be synthesized in a straightforward manner and can be made highly stable. Second, they possess unique optoelectronic properties. Third, they provide high surface-to-volume ratio with excellent biocompatibility using appropriate ligands.30 Fourth, these properties of AuNPs can be readily tuned varying their size, shape and the surrounding chemical environment. For example, the binding event between recognition element and the analyte can alter physicochemical properties of transducer AuNPs, such as plasmon resonance absorption, conductivity, redox behavior, etc. that in turn can generate a detectable response signal. Finally, AuNPs offer a suitable platform for multi-functionalization with a wide range of organic or biological ligands for the selective binding and detection of small molecules and biological targets.30–32,36 Each of these attributes of AuNPs has allowed researchers to develop novel sensing strategies with improved sensitivity, stability and selectivity. In the last decade of research, the advent of AuNP as a sensory element provided us a broad spectrum of innovative approaches for the detection of metal ions, small molecules, proteins, nucleic acids, malignant cells, etc. in a rapid and efficient manner.37 Figure 1 Physical properties of AuNPs and schematic illustration of an AuNP-based detection system. In this current review, we have highlighted the several synthetic routes and properties of AuNPs that make them excellent probes for different sensing strategies. Furthermore, we will discuss various sensing strategies and major advances in the last two decades of research utilizing AuNPs in the detection of variety of target analytes including metal ions, organic molecules, proteins, nucleic acids, and microorganisms.

3,879 citations

Journal ArticleDOI
TL;DR: The major factors that play a role in the development of clinically accurate in-vivo glucose sensors include issues related to biocompatibility, miniaturization, long-term stability of the enzyme and transducer, oxygen deficit, short stabilization times, in- vivo calibration, baseline drift, safety, and convenience.
Abstract: First-generation glucose biosensors relied on the use of the natural oxygen cosubstrate and the production and detection of hydrogen peroxide and were much simpler, especially when miniaturized sensors are concerned. More sophisticated bioelectronic systems for enhancing the electrical response, based on patterned monolayer or multilayer assemblies and organized enzyme networks on solid electrodes, have been developed for contacting GOx with the electrode support. Electrochemical biosensors are well suited for satisfying the needs of personal (home) glucose testing, and the majority of personal blood glucose meters are based on disposable (screen-printed) enzyme electrode test strips, which are mass produced by the thick film (screen-printing) microfabrication technology. In the counter and an additional “baseline” working electrode, various membranes (mesh) are incorporated into the test strips along with surfactants, to provide a uniform sample coverage. Such devices offer considerable promise for obtaining the desired clinical information in a simpler, user-friendly, faster, and cheaper manner compared to traditional assays. Continuous ex-vivo monitoring of blood glucose was proposed in 1974 and the majority of glucose sensors used for in-vivo applications are based on the GOx-catalyzed oxidation of glucose by oxygen. The major factors that play a role in the development of clinically accurate in-vivo glucose sensors include issues related to biocompatibility, miniaturization, long-term stability of the enzyme and transducer, oxygen deficit, short stabilization times, in-vivo calibration, baseline drift, safety, and convenience.

2,924 citations

Journal ArticleDOI
TL;DR: It is argued that gold nanotechnology-enabled biomedicine is not simply an act of 'gilding the (nanomedicinal) lily', but that a new 'Golden Age' of biomedical nanotechnology is truly upon us.
Abstract: Gold nanoparticles have been used in biomedical applications since their first colloidal syntheses more than three centuries ago. However, over the past two decades, their beautiful colors and unique electronic properties have also attracted tremendous attention due to their historical applications in art and ancient medicine and current applications in enhanced optoelectronics and photovoltaics. In spite of their modest alchemical beginnings, gold nanoparticles exhibit physical properties that are truly different from both small molecules and bulk materials, as well as from other nanoscale particles. Their unique combination of properties is just beginning to be fully realized in range of medical diagnostic and therapeutic applications. This critical review will provide insights into the design, synthesis, functionalization, and applications of these artificial molecules in biomedicine and discuss their tailored interactions with biological systems to achieve improved patient health. Further, we provide a survey of the rapidly expanding body of literature on this topic and argue that gold nanotechnology-enabled biomedicine is not simply an act of ‘gilding the (nanomedicinal) lily’, but that a new ‘Golden Age’ of biomedical nanotechnology is truly upon us. Moving forward, the most challenging nanoscience ahead of us will be to find new chemical and physical methods of functionalizing gold nanoparticles with compounds that can promote efficient binding, clearance, and biocompatibility and to assess their safety to other biological systems and their long-term term effects on human health and reproduction (472 references).

2,712 citations

Journal ArticleDOI
TL;DR: A review of carbon-nanotubes (CNT) based electrochemical biosensors can be found in this paper, where common designs of CNT-based sensors are discussed, along with practical examples of such devices.
Abstract: This review addresses recent advances in carbon-nanotubes (CNT) based electrochemical biosensors. The unique chemical and physical properties of CNT have paved the way to new and improved sensing devices, in general, and electrochemical biosensors, in particular. CNT-based electrochemical transducers offer substantial improvements in the performance of amperometric enzyme electrodes, immunosensors and nucleic-acid sensing devices. The greatly enhanced electrochemical reactivity of hydrogen peroxide and NADH at CNT-modified electrodes makes these nanomaterials extremely attractive for numerous oxidase- and dehydrogenase-based amperometric biosensors. Aligned CNT “forests” can act as molecular wires to allow efficient electron transfer between the underlying electrode and the redox centers of enzymes. Bioaffinity devices utilizing enzyme tags can greatly benefit from the enhanced response of the biocatalytic-reaction product at the CNT transducer and from CNT amplification platforms carrying multiple tags. Common designs of CNT-based biosensors are discussed, along with practical examples of such devices. The successful realization of CNT-based biosensors requires proper control of their chemical and physical properties, as well as their functionalization and surface immobilization.

2,170 citations

Patent
30 Oct 2007
TL;DR: An analyte monitor includes a sensor, a sensor control unit, and a display unit as discussed by the authors, which is used to display an indication of a level of an analyte, based on the data obtained using the sensor.
Abstract: An analyte monitor includes a sensor, a sensor control unit, and a display unit. The sensor has, for example, a substrate, a recessed channel formed in the substrate, and conductive material disposed in the recessed channel to form a working electrode. The sensor control unit typically has a housing adapted for placement on skin and is adapted to receive a portion of an electrochemical sensor. The sensor control unit also includes two or more conductive contacts disposed on the housing and configured for coupling to two or more contact pads on the sensor. A transmitter is disposed in the housing and coupled to the plurality of conductive contacts for transmitting data obtained using the sensor. The display unit has a receiver for receiving data transmitted by the transmitter of the sensor control unit and a display coupled to the receiver for displaying an indication of a level of an analyte. The analyte monitor may also be part of a drug delivery system to alter the level of the analyte based on the data obtained using the sensor.

1,856 citations