Journal ArticleDOI
TL;DR: In this cohort, appropriate device therapy was limited to cardiac arrest survivors, whereas none of those with syncope and/or positive EPS had arrhythmias, and overall complication rate was relatively high, including inappropriate ICD shocks.

21 citations


Cited by
More filters
Journal ArticleDOI
TL;DR: Optimal implantable cardioverter-defibrillator programming and follow-up dramatically reduce inappropriate shock in patients with Brugada syndrome, but lead failure remains a major problem in this population.
Abstract: Background— Implantable cardioverter-defibrillator indications in Brugada syndrome remain controversial, especially in asymptomatic patients. Previous outcome data are limited by relatively small numbers of patients or short follow-up durations. We report the outcome of patients with Brugada syndrome implanted with an implantable cardioverter-defibrillator in a large multicenter registry. Methods and Results— A total of 378 patients (310 male; age, 46±13 years) with a type 1 Brugada ECG pattern implanted with an implantable cardioverter-defibrillator (31 for aborted sudden cardiac arrest, 181 for syncope, and 166 asymptomatic) were included. Fifteen patients (4%) were lost to follow-up. During a mean follow-up of 77±42 months, 7 patients (2%) died (1 as a result of an inappropriate shock), and 46 patients (12%) had appropriate device therapy (5±5 shocks per patient). Appropriate device therapy rates at 10 years were 48% for patients whose implantable cardioverter-defibrillator indication was aborted sudden cardiac arrest, 19% for those whose indication was syncope, and 12% for the patients who were asymptomatic at implantation. At 10 years, rates of inappropriate shock and lead failure were 37% and 29%, respectively. Inappropriate shock occurred in 91 patients (24%; 4±4 shocks per patient) because of lead failure (n=38), supraventricular tachycardia (n=20), T-wave oversensing (n=14), or sinus tachycardia (n=12). Importantly, introduction of remote monitoring, programming a high single ventricular fibrillation zone (>210–220 bpm), and a long detection time were associated with a reduced risk of inappropriate shock. Conclusions— Appropriate therapies are more prevalent in symptomatic Brugada syndrome patients but are not insignificant in asymptomatic patients (1%/y). Optimal implantable cardioverter-defibrillator programming and follow-up dramatically reduce inappropriate shock. However, lead failure remains a major problem in this population. # Clinical Perspective {#article-title-24}

425 citations

Journal ArticleDOI
TL;DR: In this article, implantable cardioverter-defibrillator indications in Brugada syndrome remain controversial, especially in asymptomatic patients, and previous outcome data are limited by relatively small nu...
Abstract: Background—Implantable cardioverter-defibrillator indications in Brugada syndrome remain controversial, especially in asymptomatic patients. Previous outcome data are limited by relatively small nu...

238 citations

Journal ArticleDOI
TL;DR: ICD implantation carries a significant risk of inappropriate shocks and inhospital and postdischarge complications in relatively young patients with inherited arrhythmia syndromes, and these data can be used to better inform patients and physicians about the expected risk of adverse ICD events and thereby facilitate shared decision making.

199 citations

Journal ArticleDOI
TL;DR: Remote home monitoring of pacemaker and ICD devices was safe, reduced overall hospital visits, and detected events that mandated unscheduled visits.