scispace - formally typeset
Search or ask a question
Author

Shaun Colburn

Bio: Shaun Colburn is an academic researcher from The Commonwealth Medical College. The author has contributed to research in topics: Electrical conduction system of the heart & QRS complex. The author has an hindex of 1, co-authored 2 publications receiving 6 citations.

Papers
More filters
Journal ArticleDOI
21 May 2021-Europace
TL;DR: His bundle capture threshold remains stable in the majority (85%) of patients and Implant characteristics may predict the threshold rise, which may lead to chronically stable capture thresholds.
Abstract: AIMS His bundle pacing (HBP) is the most physiologic form of pacing. Long-term HBP capture threshold stability and its relation to lead characteristics at the time of implantation have not been adequately described. The aim of this study was to characterize HB capture threshold in follow-up and to identify potential lead characteristics predictive of lead capture instability. METHODS AND RESULTS Consecutive patients with successful HBP for bradycardia indications were identified from the Geisinger HBP registry. His bundle capture thresholds, baseline comorbidities, and radiographic lead slack characteristics were analysed. An increase in HB capture threshold ≥1 V above implant values at any time during follow-up was tracked. Forty-four of the 294 studied (15%) experienced HB capture threshold increase by ≥ 1 V. Threshold increase was seen early (41% by 8 weeks, 66% by 1 year). Eighteen (6%) patients required lead revision in follow-up. Abnormal slack shape was associated with a trend toward capture threshold increase [hazard ratio (HR) 2.07; 95% confidence interval (CI) 0.9-4.6; P = 0.08]. Non-perpendicular angle of lead insertion on radiography was associated with the capture threshold increase (HR 2.81, 95% CI 1.4-5.8; P < 0.01). CONCLUSION His bundle capture threshold remains stable in the majority (85%) of patients. Implant characteristics may predict the threshold rise. Further evaluation of the aetiology of threshold increase and design changes in lead and delivery systems may lead to chronically stable capture thresholds.

26 citations

Journal ArticleDOI
TL;DR: In this article, the safety and feasibility of achieving His-Purkinje conduction system pacing (HPCSP) in consecutive patients with atrioventricular block (AVB) and to describe the site of conduction block in patients with infranodal AVB were assessed.

14 citations


Cited by
More filters
01 Jul 2017
TL;DR: The aim of this study is to assess His bundle capture and its effect on left ventricular function in long‐term follow‐up and to determine HPC at the time of pulse generator change (GC) in patients with chronic HBP.
Abstract: BACKGROUND Permanent His bundle pacing (HBP) is a physiological alternative to right ventricular pacing. It is not known whether HBP can cause His-Purkinje conduction (HPC) disease. The aim of our study is to assess His bundle capture and its effect on left ventricular (LV) function in long-term follow-up and to determine HPC at the time of pulse generator change (GC) in patients with chronic HBP. METHODS HB electrograms were recorded from the pacing lead at implant and GC. HBP QRS duration (QRSd), His-ventricular (HV) intervals, and HB pacing thresholds at GC were compared with implant measurements. HPC was assessed by pacing at cycle lengths of 700 ms, 600 ms, and 500 ms at GC. LV internal diameters, ejection fraction (EF), and valve dysfunction at baseline were compared with echocardiography during follow-up. RESULTS GC was performed in 20 patients (men 13; age 74 ± 14 years) with HBP at 70 ± 24 months postimplant. HV intervals remained unchanged from initial implant (44 ± 4 ms vs 45 ± 4 ms). During HBP at 700 ms, 600 ms, and 500 ms (n = 17), consistent 1:1 HPC was present. HBP QRSd remained unchanged during follow-up (117 ± 20 ms vs 118 ± 23 ms). HBP threshold at implant and GC was 1.9 ± 1.1 V and 2.5 ± 1.2 V @ 0.5 ms. Despite high pacing burden (77 ± 13%), there was no significant change in LVEF (50 ± 14% at implant) during follow-up (55 ± 6%, P = 0.06). CONCLUSIONS HBP does not appear to cause new HPC abnormalities and is associated with stable HBP QRSd during long-term follow-up. Despite high pacing burden, HBP did not result in deterioration of left ventricular systolic function or cause new valve dysfunction.

32 citations

Journal ArticleDOI
TL;DR: In this article, the safety and feasibility of achieving His-Purkinje conduction system pacing (HPCSP) in consecutive patients with atrioventricular block (AVB) and to describe the site of conduction block in patients with infranodal AVB were assessed.

14 citations

Journal ArticleDOI
TL;DR: In this paper , the safety and feasibility of achieving His-Purkinje conduction system pacing (HPCSP) in consecutive patients with atrioventricular block (AVB) and to describe the site of conduction block in patients with infranodal AVB were assessed.

13 citations

Journal ArticleDOI
01 Apr 2023-Europace
TL;DR: In this paper , the authors provide a framework for physicians who wish to start CSP implantation, or who want to improve their technique, as well as a standardization of the procedure and to provide a guidance for physicians.
Abstract: Abstract Conduction system pacing (CSP) has emerged as a more physiological alternative to right ventricular pacing and is also being used in selected cases for cardiac resynchronization therapy. His bundle pacing was first introduced over two decades ago and its use has risen over the last five years with the advent of tools which have facilitated implantation. Left bundle branch area pacing is more recent but its adoption is growing fast due to a wider target area and excellent electrical parameters. Nevertheless, as with any intervention, proper technique is a prerequisite for safe and effective delivery of therapy. This document aims to standardize the procedure and to provide a framework for physicians who wish to start CSP implantation, or who wish to improve their technique.

12 citations

Journal ArticleDOI
TL;DR: Left bundle branch area pacing (LBBAP) is a safe and effective alternative option for patients needing ventricular pacing and his bundle pacing (HBP) is the most physiologic form of pacing.
Abstract: His bundle pacing (HBP) is the most physiologic form of pacing and has been associated with reduced risk for heart failure hospitalization (HFH) and mortality compared to right ventricular pacing. Left bundle branch area pacing (LBBAP) is a safe and effective alternative option for patients needing ventricular pacing. The aim of this study was to compare the clinical outcomes between LBBAP and HBP among a large cohort of patients undergoing permanent pacemaker implantation.

12 citations