Author

Sotiria Triantopoulou

Bio: Sotiria Triantopoulou is an academic researcher. The author has an hindex of 1, co-authored 1 publications receiving 1 citations.

Papers
More filters
Journal ArticleDOI
TL;DR: In this article, the dicentric chromosome assay (DCA) results were homogeneous between participants and matched well with the reference doses (≥95% of estimates within ± 0.5 Gy of the reference).
Abstract: PURPOSE Biological and/or physical assays for retrospective dosimetry are valuable tools to recover the exposure situation and to aid medical decision making. To further validate and improve such biological and physical assays, in 2019, EURADOS Working Group 10 and RENEB performed a field exercise in Lund, Sweden, to simulate various real-life exposure scenarios. MATERIALS AND METHODS For the dicentric chromosome assay (DCA), blood tubes were located at anthropomorphic phantoms positioned in different geometries and were irradiated with a 1.36 TBq 192Ir-source. For each exposure condition, dose estimates were provided by at least one laboratory and for four conditions by 17 participating RENEB laboratories. Three radio-photoluminescence glass dosimeters were placed at each tube to assess reference doses. RESULTS The DCA results were homogeneous between participants and matched well with the reference doses (≥95% of estimates within ±0.5 Gy of the reference). For samples close to the source systematic underestimation could be corrected by accounting for exposure time. Heterogeneity within and between tubes was detected for reference doses as well as for DCA doses estimates. CONCLUSIONS The participants were able to successfully estimate the doses and to provide important information on the exposure scenarios under conditions closely resembling a real-life situation.

17 citations


Cited by
More filters
Journal ArticleDOI
TL;DR: Biodose Tools as mentioned in this paper is an open source toolkit for biological dosimetry using the R programming language and the shiny package as a framework to create a user-friendly online solution.
Abstract: Introduction In the event of a radiological accident or incident, the aim of biological dosimetry is to convert the yield of a specific biomarker of exposure to ionizing radiation into an absorbed dose. Since the 1980s, various tools have been used to deal with the statistical procedures needed for biological dosimetry, and in general those who made several calculations for different biomarkers were based on closed source software. Here we present a new open source program, Biodose Tools, that has been developed under the umbrella of RENEB (Running the European Network of Biological and retrospective Physical dosimetry).Material and Methods The application has been developed using the R programming language and the shiny package as a framework to create a user-friendly online solution. Since no unique method exists for the different mathematical processes, several meetings and periodic correspondence were held in order to reach a consensus on the solutions to be implemented.Results The current version 3.6.1 supports dose-effect fitting for dicentric and translocation assay. For dose estimation Biodose Tools implements those methods indicated in international guidelines and a specific method to assess heterogeneous exposures. The app can include information on the irradiation conditions to generate the calibration curve. Also, in the dose estimate, information about the accident can be included as well as the explanation of the results obtained. Because the app allows generating a report in various formats, it allows traceability of each biological dosimetry study carried out. The app has been used globally in different exercises and training, which has made it possible to find errors and improve the app itself. There are some features that still need consensus, such as curve fitting and dose estimation using micronucleus analysis. It is also planned to include a package dedicated to interlaboratory comparisons and the incorporation of Bayesian methods for dose estimation.Conclusion Biodose Tools provides an open-source solution for biological dosimetry laboratories. The consensus reached helps to harmonize the way in which uncertainties are calculated. In addition, because each laboratory can download and customize the app's source code, it offers a platform to integrate new features.

8 citations

Journal ArticleDOI
TL;DR: The results obtained with the cytokinesis-block micronucleus assay were reported in this paper , showing that the micronuclus assay allowed classification of samples in the corresponding clinical triage categories (low, medium, high dose category) in 88% of cases (manual scoring, 88%; semi-automated scoring, 100%; automated scoring, 73%).
Abstract: The goal of the RENEB inter-laboratory comparison 2021 exercise was to simulate a large-scale radiation accident involving a network of biodosimetry labs. Labs were required to perform their analyses using different biodosimetric assays in triage mode scoring and to rapidly report estimated radiation doses to the organizing institution. This article reports the results obtained with the cytokinesis-block micronucleus assay. Three test samples were exposed to blinded doses of 0, 1.2 and 3.5 Gy X-ray doses (240 kVp, 13 mA, ∼75 keV, 1 Gy/min). These doses belong to 3 triage categories of clinical relevance: a low dose category, for no exposure or exposures inferior to 1 Gy, requiring no direct treatment of subjects; a medium dose category, with doses ranging from 1 to 2 Gy, and a high dose category, after exposure to doses higher than 2 Gy, with the two latter requiring increasing medical attention. After irradiation the test samples (no. 1, no. 2 and no. 3) were sent by the organizing laboratory to 14 centers participating in the micronucleus assay exercise. Laboratories were asked to setup micronucleus cultures and to perform the micronucleus assay in triage mode, scoring 500 binucleated cells manually, or 1,000 binucleated cells in automated/semi-automated mode. One laboratory received no blood samples, but scored pictures from another lab. Based on their calibration curves, laboratories had to provide estimates of the administered doses. The accuracy of the reported dose estimates was further analyzed by the micronucleus assay lead. The micronucleus assay allowed classification of samples in the corresponding clinical triage categories (low, medium, high dose category) in 88% of cases (manual scoring, 88%; semi-automated scoring, 100%; automated scoring, 73%). Agreement between scoring laboratories, assessed by calculating the Fleiss' kappa, was excellent (100%) for semi-automated scoring, good (83%) for manual scoring and poor (53%) for fully automated scoring. Correct classification into triage scoring dose intervals (reference dose ±0.5 Gy for doses ≤2.5 Gy, or reference dose ±1 Gy for doses >2.5 Gy), recommended for triage biodosimetry, was obtained in 79% of cases (manual scoring, 73%; semi-automated scoring, 100%; automated scoring, 67%). The percentage of dose estimates whose 95% confidence intervals included the reference dose was 58% (manual scoring, 48%; semiautomated scoring, 72%; automated scoring, 60%). For the irradiated samples no. 2 and no. 3, a systematic shift towards higher dose estimations was observed. This was also noticed with the other cytogenetic assays in this intercomparison exercise. Accuracy of the rapid triage modality could be maintained when the number of manually scored cells was scaled down to 200 binucleated cells. In conclusion, the micronucleus assay, preferably performed in a semi-automated or manual scoring mode, is a reliable technique to perform rapid biodosimetry analysis in large-scale radiation emergencies.

4 citations

Journal ArticleDOI
TL;DR: In the case of a large-scale event, the main aim of biological dosimetry is the categorization of individuals into clinically relevant groups, to aid clinical decision making as discussed by the authors .
Abstract: After large-scale radiation accidents where many individuals are suspected to be exposed to ionizing radiation, biological and physical retrospective dosimetry assays are important tools to aid clinical decision making by categorizing individuals into unexposed/minimally, moderately or highly exposed groups. Quality-controlled inter-laboratory comparisons of simulated accident scenarios are regularly performed in the frame of the European legal association RENEB (Running the European Network of Biological and Physical retrospective Dosimetry) to optimize international networking and emergency readiness in case of large-scale radiation events. In total 33 laboratories from 22 countries around the world participated in the current RENEB inter-laboratory comparison 2021 for the dicentric chromosome assay. Blood was irradiated in vitro with X rays (240 kVp, 13 mA, ∼75 keV, 1 Gy/min) to simulate an acute, homogeneous whole-body exposure. Three blood samples (no. 1: 0 Gy, no. 2: 1.2 Gy, no. 3: 3.5 Gy) were sent to each participant and the task was to culture samples, to prepare slides and to assess radiation doses based on the observed dicentric yields from 50 manually or 150 semi-automatically scored metaphases (triage mode scoring). Approximately two-thirds of the participants applied calibration curves from irradiations with γ rays and about 1/3 from irradiations with X rays with varying energies. The categorization of the samples in clinically relevant groups corresponding to individuals that were unexposed/minimally (0–1 Gy), moderately (1–2 Gy) or highly exposed (>2 Gy) was successfully performed by all participants for sample no. 1 and no. 3 and by ≥74% for sample no. 2. However, while most participants estimated a dose of exactly 0 Gy for the sham-irradiated sample, the precise dose estimates of the samples irradiated with doses >0 Gy were systematically higher than the corresponding reference doses and showed a median deviation of 0.5 Gy (sample no. 2) and 0.95 Gy (sample no. 3) for manual scoring. By converting doses estimated based on γ-ray calibration curves to X-ray doses of a comparable mean photon energy as used in this exercise, the median deviation decreased to 0.27 Gy (sample no. 2) and 0.6 Gy (sample no. 3). The main aim of biological dosimetry in the case of a large-scale event is the categorization of individuals into clinically relevant groups, to aid clinical decision making. This task was successfully performed by all participants for the 0 Gy and 3.5 Gy samples and by 74% (manual scoring) and 80% (semiautomatic scoring) for the 1.2 Gy sample. Due to the accuracy of the dicentric chromosome assay and the high number of participating laboratories, a systematic shift of the dose estimates could be revealed. Differences in radiation quality (X ray vs. γ ray) between the test samples and the applied dose effect curves can partly explain the systematic shift. There might be several additional reasons for the observed bias (e.g., donor effects, transport, experimental conditions or the irradiation setup) and the analysis of these reasons provides great opportunities for future research. The participation of laboratories from countries around the world gave the opportunity to compare the results on an international level.

4 citations

Journal ArticleDOI
TL;DR: The results obtained with the cytokinesis-block micronucleus assay were reported in this paper , showing that the micronuclus assay allowed classification of samples in the corresponding clinical triage categories (low, medium, high dose category) in 88% of cases (manual scoring, 88%; semi-automated scoring, 100%; automated scoring, 73%).
Abstract: The goal of the RENEB inter-laboratory comparison 2021 exercise was to simulate a large-scale radiation accident involving a network of biodosimetry labs. Labs were required to perform their analyses using different biodosimetric assays in triage mode scoring and to rapidly report estimated radiation doses to the organizing institution. This article reports the results obtained with the cytokinesis-block micronucleus assay. Three test samples were exposed to blinded doses of 0, 1.2 and 3.5 Gy X-ray doses (240 kVp, 13 mA, ∼75 keV, 1 Gy/min). These doses belong to 3 triage categories of clinical relevance: a low dose category, for no exposure or exposures inferior to 1 Gy, requiring no direct treatment of subjects; a medium dose category, with doses ranging from 1 to 2 Gy, and a high dose category, after exposure to doses higher than 2 Gy, with the two latter requiring increasing medical attention. After irradiation the test samples (no. 1, no. 2 and no. 3) were sent by the organizing laboratory to 14 centers participating in the micronucleus assay exercise. Laboratories were asked to setup micronucleus cultures and to perform the micronucleus assay in triage mode, scoring 500 binucleated cells manually, or 1,000 binucleated cells in automated/semi-automated mode. One laboratory received no blood samples, but scored pictures from another lab. Based on their calibration curves, laboratories had to provide estimates of the administered doses. The accuracy of the reported dose estimates was further analyzed by the micronucleus assay lead. The micronucleus assay allowed classification of samples in the corresponding clinical triage categories (low, medium, high dose category) in 88% of cases (manual scoring, 88%; semi-automated scoring, 100%; automated scoring, 73%). Agreement between scoring laboratories, assessed by calculating the Fleiss' kappa, was excellent (100%) for semi-automated scoring, good (83%) for manual scoring and poor (53%) for fully automated scoring. Correct classification into triage scoring dose intervals (reference dose ±0.5 Gy for doses ≤2.5 Gy, or reference dose ±1 Gy for doses >2.5 Gy), recommended for triage biodosimetry, was obtained in 79% of cases (manual scoring, 73%; semi-automated scoring, 100%; automated scoring, 67%). The percentage of dose estimates whose 95% confidence intervals included the reference dose was 58% (manual scoring, 48%; semi-automated scoring, 72%; automated scoring, 60%). For the irradiated samples no. 2 and no. 3, a systematic shift towards higher dose estimations was observed. This was also noticed with the other cytogenetic assays in this intercomparison exercise. Accuracy of the rapid triage modality could be maintained when the number of manually scored cells was scaled down to 200 binucleated cells. In conclusion, the micronucleus assay, preferably performed in a semi-automated or manual scoring mode, is a reliable technique to perform rapid biodosimetry analysis in large-scale radiation emergencies.

3 citations

Journal ArticleDOI
Matthias Port, Joan Francesc Barquinero, D. Endesfelder, Jayne Moquet, Ursula Oestreicher, Georgia I. Terzoudi, François Trompier, Anne Vral, Yu Abe, Liz Ainsbury, Sally A. Amundson, Christophe Badie, Ans Baeyens, A.S. Balajee, Katalin Balázs, Stephen Barnard, C. Bassinet, Lindsay A. Beaton-Green, Christina Beinke, Laure Bobyk, Paul Brochard, Kamil Brzóska, Martin Bucher, Bartlomiej Ciesielski, Corina Cuceu, Michael Wiescher, Maria Cristina D'Oca, Inmaculada Domínguez, Sven Doucha-Senf, Anca Dumitrescu, Phuong Nguyen Duy, F. Finot, Guy Garty, Shanaz A. Ghandhi, Eric Gregoire, Valerie Swee Ting Goh, Incli Güçlü, Ljubomira Hadjiiska, Réka H. Hargitai, Rositsa Hristova, Keizo Ishii, Enikő Kis, Małgorzata Juniewicz, Ralf Kriehuber, Jerome Lacombe, Milagrosa López Riego, Katalin Lumniczky, Trinh Thuong Mai, Nadica Maltar-Strmečki, Maurizio Marrale, Aleksandra E. Marciniak, Natalie Maznyk, S. McKeever, P.K. Meher, Marcela Milanová, Tomoyuki Miura, Octávia Monteiro Gil, Alegría Montoro, M. Moreno-Domene, A. Mrozik, Ryo Nakayama, Grainne O’Brien, Dominik Oskamp, Patrick Ostheim, J. Pajic, N. Ramos Pastor, C. Patrono, Monica Pujol-Canadell, Mikhail Repin, Alexander Romanyukha, Ute Rößler, Laurent Sabatier, Akira Sakai, Harry Scherthan, Simone Schüle, Kang, Moon Seong, Olga Sevriukova, Sergey Sholom, Sylwester Sommer, Yumiko Suto, Tetiana Sypko, Tünde Szatmári, Kai Takebayashi, Antonella Testa, Isabelle Testard, Ales Tichy, Sotiria Triantopoulou, Nanae Tsuyama, Marcus Unverricht-Yeboah, Marco Valente, Olivier Van Hoey, Ruth C. Wilkins, Agata Wójcik, Maria Wojewódzka, Lee YoungHyun, D. Zafiropoulos, Michael Abend 
TL;DR: In the current RENEB inter-laboratory comparison, the performance quality of established cytogenetic assays [dicentric chromosome assay (DCA), cytokinesis-block micronucleus assay (CBMN), stable chromosomal translocation assay (FISH) and premature chromosome condensation assay (PCC)] was tested in comparison to molecular biological assays as mentioned in this paper .
Abstract: Tools for radiation exposure reconstruction are required to support the medical management of radiation victims in radiological or nuclear incidents. Different biological and physical dosimetry assays can be used for various exposure scenarios to estimate the dose of ionizing radiation a person has absorbed. Regular validation of the techniques through inter-laboratory comparisons (ILC) is essential to guarantee high quality results. In the current RENEB inter-laboratory comparison, the performance quality of established cytogenetic assays [dicentric chromosome assay (DCA), cytokinesis-block micronucleus assay (CBMN), stable chromosomal translocation assay (FISH) and premature chromosome condensation assay (PCC)] was tested in comparison to molecular biological assays [gamma-H2AX foci (gH2AX), gene expression (GE)] and physical dosimetry-based assays [electron paramagnetic resonance (EPR), optically or thermally stimulated luminescence (LUM)]. Three blinded coded samples (e.g., blood, enamel or mobiles) were exposed to 0, 1.2 or 3.5 Gy X-ray reference doses (240 kVp, 1 Gy/min). These doses roughly correspond to clinically relevant groups of unexposed to low exposed (0–1 Gy), moderately exposed (1–2 Gy, no severe acute health effects expected) and highly exposed individuals (>2 Gy, requiring early intensive medical care). In the frame of the current RENEB inter-laboratory comparison, samples were sent to 86 specialized teams in 46 organizations from 27 nations for dose estimation and identification of three clinically relevant groups. The time for sending early crude reports and more precise reports was documented for each laboratory and assay where possible. The quality of dose estimates was analyzed with three different levels of granularity, 1. by calculating the frequency of correctly reported clinically relevant dose categories, 2. by determining the number of dose estimates within the uncertainty intervals recommended for triage dosimetry (±0.5 Gy or ±1.0 Gy for doses <2.5 Gy or >2.5 Gy), and 3. by calculating the absolute difference (AD) of estimated doses relative to the reference doses. In total, 554 dose estimates were submitted within the 6-week period given before the exercise was closed. For samples processed with the highest priority, earliest dose estimates/categories were reported within 5–10 h of receipt for GE, gH2AX, LUM, EPR, 2–3 days for DCA, CBMN and within 6–7 days for the FISH assay. For the unirradiated control sample, the categorization in the correct clinically relevant group (0–1 Gy) as well as the allocation to the triage uncertainty interval was, with the exception of a few outliers, successfully performed for all assays. For the 3.5 Gy sample the percentage of correct classifications to the clinically relevant group (≥2 Gy) was between 89–100% for all assays, with the exception of gH2AX. For the 1.2 Gy sample, an exact allocation to the clinically relevant group was more difficult and 0–50% or 0–48% of the estimates were wrongly classified into the lowest or highest dose categories, respectively. For the irradiated samples, the correct allocation to the triage uncertainty intervals varied considerably between assays for the 1.2 Gy (29–76%) and 3.5 Gy (17–100%) samples. While a systematic shift towards higher doses was observed for the cytogenetic-based assays, extreme outliers exceeding the reference doses 2–6 fold were observed for EPR, FISH and GE assays. These outliers were related to a particular material examined (tooth enamel for EPR assay, reported as kerma in enamel, but when converted into the proper quantity, i.e. to kerma in air, expected dose estimates could be recalculated in most cases), the level of experience of the teams (FISH) and methodological uncertainties (GE). This was the first RENEB ILC where everything, from blood sampling to irradiation and shipment of the samples, was organized and realized at the same institution, for several biological and physical retrospective dosimetry assays. Almost all assays appeared comparably applicable for the identification of unexposed and highly exposed individuals and the allocation of medical relevant groups, with the latter requiring medical support for the acute radiation scenario simulated in this exercise. However, extreme outliers or a systematic shift of dose estimates have been observed for some assays. Possible reasons will be discussed in the assay specific papers of this special issue. In summary, this ILC clearly demonstrates the need to conduct regular exercises to identify research needs, but also to identify technical problems and to optimize the design of future ILCs.

3 citations