scispace - formally typeset
Search or ask a question
Author

Tijana Lainović

Bio: Tijana Lainović is an academic researcher from University of Novi Sad. The author has contributed to research in topics: Surface roughness & Polishing. The author has an hindex of 8, co-authored 10 publications receiving 123 citations.

Papers
More filters
Journal ArticleDOI
TL;DR: Type, size, distribution of fillers and filler loading in tested materials, didn't influence average roughness values, but had an impact on maximum peak-to-valley distance values.
Abstract: The aim of this study was to determine surface roughness and topography of polished dental resin-based nanocomposites. Four representative dental resin-based nanocomposites were tested in the study: two nanohybrids (Filtek Z550 and Tetric EvoCeram) and two nanofilled (Filtek Ultimate Body and Filtek Ultimate Translucent); and two reference materials: one microfilled (Gradia Direct) and one microhybrid (Filtek Z250). Polymerized cylindrical specimens (4 mm x 2 mm) were polished with multi-step polishing system- Super Snap. Immediately after the polishing, topography of each specimen was examined by Veeco di CP-II Atomic Force Microscope. Specimen's surface has been scanned in 6 points in contact mode with CONT20A-CP tips. 1 Hz scan rate and 256 × 256 resolution were used to obtain topography on a 90 µm × 90 µm scanning area. Measured topography data were processed by Image Processing and Data Analysis v2.1.15 software. Following parameters were compared among specimens: average roughness and maximum peak-to-valley distance. All of the tested materials had similar average surface roughness after finishing and polishing procedure. The lowest values occurred in the material Filtek Ultimate Body, and the highest in the Filtek Z550. When interpreting maximum peak-to-valley distance the larger differences in values (up to 100%) occurred in Filtek Z550, Filtek Z250 and Filtek Ultimate Body, which is a result of the deep polishing channels and tracks. Type, size, distribution of fillers and filler loading in tested materials, didn't influence average roughness values, but had an impact on maximum peak-to-valley distance values.

33 citations

Journal ArticleDOI
TL;DR: In this paper, the effect of different dental polishing methods on surface texture parameters of dental nanocomposites was investigated by atomic force microscopy (AFM) and multifractal analysis.

24 citations

Journal ArticleDOI
TL;DR: The technical quality of root canal fillings performed by undergraduate students at the School of Dentistry, Faculty of Medicine, University of Novi Sad, Serbia was satisfactory.
Abstract: Aim. The aim of this study was to evaluate the radiographic technical quality of endodontic treatment performed by undergraduate students at the School of Dentistry, Faculty of Medicine, University of Novi Sad, Serbia. Materials and Methods. Electronic records of 220 patients treated by final-year undergraduate students during the school year 2011/2012 were examined, and the final sample consisted of 212 patients, 322 teeth, and 565 root canals. The criteria for overall radiographic adequacy of root canal fillings were defined as the presence of adequate length and density and absence of iatrogenic errors (ledge, fractured instrument, untreated canal, and apical transportation). Chi-square test was used to determine statistical significance between different parameters. Results. Adequate root canal fillings were found in 74.22% of the teeth. The percentage of root fillings with adequate length and density was 89.73% and 92.6%, respectively. Fractured instruments and ledges were present in 16 root canals (2.8%), while the presence of missed canal and apical transportation was observed in 2 cases, each (0.3%). Conclusions. Overall, the technical quality of root canal fillings performed by undergraduate students was satisfactory.

23 citations

Journal ArticleDOI
TL;DR: A microscope based on Brillouin light scattering (BLS) developed to probe the spectrum of the light scattered from tooth tissues, from which the mechanical properties can be inferred with a priori knowledge of the refractive index are described.

15 citations

Journal ArticleDOI
TL;DR: Results of this study showed that diamond paste polishing was useful processing method which significantly reduced surface roughness and created favorable topography of tested nanohybrid composite materials.

15 citations


Cited by
More filters
Journal Article
TL;DR: In this paper, the authors determined the ultimate tensile strength (UTS) of enamel (E), dentin (D) and dentin-enamel junction (DEJ) using the microtensile technique.
Abstract: Objective . This study determined the ultimate tensile strength (UTS) of enamel (E), dentin (D) and dentin–enamel junction (DEJ) using the microtensile technique. It was hypothesized that the UTS of dental structures varies according to location and nature. Methods . Intact occlusal enamel surfaces from extracted human third molars were etched with 37% phosphoric acid and bonded with a one-bottle adhesive system. The bonded occlusal surfaces received a resin composite build-up and teeth were serially, vertically sectioned into several 0.7 mm thick slabs. Each slab was then trimmed to a dumbbell-shaped specimen with irrigated diamond burs to reduce the cross-sectional area to approximately 0.5 mm 2 at E, D or DEJ. E was tested according to its prismatic orientation (parallel, EP; and transversally, ET) and D as function of depth (superficial, DS; middle, DM and deep, DD). Specimens were tested in tension in an Instron testing machine at 0.5 mm/min. Results were analyzed by one-way ANOVA and Duncan's Multiple Range test. Results. UTS mean values ( N =20) were, MPa (SD): DEJ, 46.9 (13.7) b ; EP, 42.1 (11.9) b ; ET, 11.5 (4.7) d ; DS, 61.6 (16.2) a ; DM, 48.7 (16.6) b and DD, 33.9 (7.9) c . Enamel stressed transversally to its prismatic orientation was significantly weaker ( p p p >0.05). Significance . The UTS of dental structures varies according to its nature and location.

197 citations

Journal ArticleDOI
TL;DR: New developments in nanotechnology applied to dentistry, focusing on the use of nanomaterials for improving the quality of oral care, are discussed, the perspectives of research in this arena, and discussions on safety concerns regarding theUse of dental nanommaterials are discussed.

154 citations

Journal Article
TL;DR: Polishing procedures significantly roughen the surface of the restoration compared to the unpolished Mylar controls.
Abstract: Background: It is beyond doubt that finishing and polishing of a composite restoration enhance its esthetics and, is also essential for the health of the periodontium. A variety of instruments are commonly used for finishing and polishing tooth-colored restorative materials Thus, it is important to understand which type of surface finishing treatments would significantly affect the staining and surface irregularities of the composite resin restoration. Still one of the properties of the composite resins that have to pass the test of time is its color stability. In modern day dentistry, a large emphasis is laid over esthetics. Hence, it is important to understand the various agents capable of adversely affecting the esthetics of a restoration due to its staining capacity. Thus, the aim of this in vitro study was to evaluate the effect of surface polishing, oral beverages and food colorants on the color stability and surface roughness of nanocomposite resins.

77 citations

Journal ArticleDOI
TL;DR: This work fabricated well-aligned, highly-ordered, smooth-mouth TiO2 nanotube arrays (TNAs) in a two-step anodization process of titanium foil, which were then used asphotoelectrodes for PEC water splitting and demonstrates for the first time correspondence between non-linear component characteristics of multiscale rough surface and crystalline structure of annealed TNAs measured at various fabrication stages and their photoelectrochemical response.
Abstract: Nowadays, increasing awareness of environment and fossil fuels protection stimulates intensive research on clean and renewable sources of energy. Production of hydrogen from water through solar-driven splitting reactions is one of the most promising approaches in the field of photoelectrochemistry (PEC). In this work we have fabricated well-aligned, highly-ordered, smooth-mouth TiO2 nanotube arrays (TNAs) in a two-step anodization process of titanium foil, which were then used as photoelectrodes for PEC water splitting. It demonstrates for the first time correspondence between non-linear component characteristics of multiscale rough surface and crystalline structure of annealed TNAs measured at various fabrication stages and their photoelectrochemical response. The as-anodized TNAs with isotropic surface (deduced from AFM and SEM images) and largest figure of merit (according to their PEC performance) were annealed at 450 °C in air. Scale-invariant descriptors of the surface structure of the deposits involved: fractal dimension, corner frequency, roughness, size of nanostructures and their dominant habits. Moreover, X-ray diffraction data processed using the Rietveld method confirmed co-existence of various oxides, for example: TiO2 in the form of anatase, TiO and Ti3O5 phases in the TNAs under study pointing that previous well-established mechanisms of the TNA growth were to certain degree incomplete.

60 citations