scispace - formally typeset
Search or ask a question
Author

Tingrui Pan

Bio: Tingrui Pan is an academic researcher from University of California, Davis. The author has contributed to research in topics: Pressure sensor & Microfluidics. The author has an hindex of 32, co-authored 175 publications receiving 4069 citations. Previous affiliations of Tingrui Pan include Chinese Academy of Sciences & University of Science and Technology of China.


Papers
More filters
Journal ArticleDOI
TL;DR: A deeper understanding of the fundamental challenges faced for wearable sensors and of the state-of-the-art for wearable sensor technology, the roadmap becomes clearer for creating the next generation of innovations and breakthroughs.
Abstract: Wearable sensors have recently seen a large increase in both research and commercialization. However, success in wearable sensors has been a mix of both progress and setbacks. Most of commercial progress has been in smart adaptation of existing mechanical, electrical and optical methods of measuring the body. This adaptation has involved innovations in how to miniaturize sensing technologies, how to make them conformal and flexible, and in the development of companion software that increases the value of the measured data. However, chemical sensing modalities have experienced greater challenges in commercial adoption, especially for non-invasive chemical sensors. There have also been significant challenges in making significant fundamental improvements to existing mechanical, electrical, and optical sensing modalities, especially in improving their specificity of detection. Many of these challenges can be understood by appreciating the body's surface (skin) as more of an information barrier than as an information source. With a deeper understanding of the fundamental challenges faced for wearable sensors and of the state-of-the-art for wearable sensor technology, the roadmap becomes clearer for creating the next generation of innovations and breakthroughs.

680 citations

Journal ArticleDOI
TL;DR: A flexible, transparent iontronic film is introduced as a thin-film capacitive sensing material for emerging wearable and health-monitoring applications that offers a large unit-area capacitance and an ultrahigh sensitivity.
Abstract: A flexible, transparent iontronic film is introduced as a thin-film capacitive sensing material for emerging wearable and health-monitoring applications. Utilizing the capacitive interface at the ionic-electronic contact, the iontronic film sensor offers a large unit-area capacitance (of 5.4 μF cm(-2) ) and an ultrahigh sensitivity (of 3.1 nF kPa(-1) ), which is a thousand times greater than that of traditional solid-state counterparts.

326 citations

Journal ArticleDOI
TL;DR: Modeling exercises support substantial impairment in outflow facility with increased HTM stiffness, and suggest an increased flow resistance with increasing HTM modulus in the onset and progression of glaucoma.
Abstract: PURPOSE. Elevated intraocular pressure (IOP) is a risk factor for glaucoma. The principal outflow pathway for aqueous humor in the human eye is through the trabecular meshwork (HTM) and Schlemm’s canal (SC). The junction between the HTM and SC is thought to have a significant role in the regulation of IOP. A possible mechanism for the increased resistance to flow in glaucomatous eyes is an increase in stiffness (increased elastic modulus) of the HTM. In this study, the stiffness of the HTM in normal and glaucomatous tissue was compared, and a mathematical model was developed to predict the impact of changes in stiffness of the juxtacanalicular layer of HTM on flow dynamics through this region. METHODS. Atomic force microscopy (AFM) was used to measure the elastic modulus of normal and glaucomatous HTM. According to these results, a model was developed that simulated the juxtacanalicular layer of the HTM as a flexible membrane with embedded pores. RESULTS. The mean elastic modulus increased substantially in the glaucomatous HTM (mean 80.8 kPa) compared with that in the normal HTM (mean 4.0 kPa). Regional variation was identified across the glaucomatous HTM, possibly corresponding to the disease state. Mathematical modeling suggested an increased flow resistance with increasing HTM modulus. CONCLUSIONS. The data indicate that the stiffness of glaucomatous HTM is significantly increased compared with that of normal HTM. Modeling exercises support substantial impairment in outflow facility with increased HTM stiffness. Alterations in the biophysical attributes of the HTM may participate directly in the onset and progression of glaucoma. (Invest Ophthalmol Vis Sci. 2011;52:2147‐2152) DOI:10.1167/iovs.10-6342

288 citations

Journal ArticleDOI
TL;DR: In this paper, a conductive photodefinable polydimethylsiloxane (PDMS) composites that provide both high electrical conductivity and photopatternability have been developed.
Abstract: Conductive photodefinable polydimethylsiloxane (PDMS) composites that provide both high electrical conductivity and photopatternability have been developed. The photosensitive composite materials, which consist of a photosensitive component, a conductive filler, and a PDMS pre-polymer, can be used as a negative photoresist or a positive photoresist with an additional curing agent. A standard photolithographic approach has been used to fabricate conductive elastomeric microstructures. Feature sizes of 60 µm in the positive photoresist and 10 µm in the negative photoresist have been successfully achieved. Moreover, as the conductive filler, silver powders significantly improve the electrical conductivity of the PDMS polymer, but also provide enhanced mechanical and thermal properties as well as interesting biological properties. The combined electrical, mechanical, thermal, and biological properties along with photopatternability make the PDMS-Ag composite an excellent processable and structural material for various microfabrication applications.

200 citations

Journal ArticleDOI
TL;DR: In this article, a PDMS-membrane micropump with two one-way ball check-valves for lab-on-a-chip and microfluidic applications is presented.
Abstract: In this paper, we present a low-cost, PDMS-membrane micropump with two one-way ball check-valves for lab-on-a-chip and microfluidic applications. The micropump consists of two functional PDMS layers, one holding the ball check-valves and an actuating chamber, and the other covering the chamber and holding a miniature permanent magnet on top for actuation. An additional PDMS layer is used to cover the top magnet, and thereby encapsulate the entire device. A simple approach was used to assemble a high-performance ball check-valve using a micropipette and heat shrink tubing. The micropump can be driven by an external magnetic force provided by another permanent magnet or an integrated coil. In the first driving scheme, a small dc motor (6 mm in diameter and 15 mm in length) with a neodymium–iron–boron permanent magnet embedded in its shaft was used to actuate the membrane-mounted magnet. This driving method yielded a large pumping rate with very low power consumption. A maximum pumping rate of 774 µL min−1 for deionized water was achieved at the input power of 13 mW, the highest pumping rate reported in the literature for micropumps at such power consumptions. Alternatively, we actuated the micropump with a 10-turn planar coil fabricated on a PC board. This method resulted in a higher pumping rate of 1 mL min−1 for deionized water. Although more integratable and compact, the planar microcoil driving technique has a much higher power consumption.

178 citations


Cited by
More filters
28 Jul 2005
TL;DR: PfPMP1)与感染红细胞、树突状组胞以及胎盘的单个或多个受体作用,在黏附及免疫逃避中起关键的作�ly.
Abstract: 抗原变异可使得多种致病微生物易于逃避宿主免疫应答。表达在感染红细胞表面的恶性疟原虫红细胞表面蛋白1(PfPMP1)与感染红细胞、内皮细胞、树突状细胞以及胎盘的单个或多个受体作用,在黏附及免疫逃避中起关键的作用。每个单倍体基因组var基因家族编码约60种成员,通过启动转录不同的var基因变异体为抗原变异提供了分子基础。

18,940 citations

Journal ArticleDOI
TL;DR: Although combinatorial chemistry techniques have succeeded as methods of optimizing structures and have been used very successfully in the optimization of many recently approved agents, they are still able to identify only two de novo combinatorials compounds approved as drugs in this 39-year time frame.
Abstract: This review is an updated and expanded version of the five prior reviews that were published in this journal in 1997, 2003, 2007, 2012, and 2016. For all approved therapeutic agents, the time frame has been extended to cover the almost 39 years from the first of January 1981 to the 30th of September 2019 for all diseases worldwide and from ∼1946 (earliest so far identified) to the 30th of September 2019 for all approved antitumor drugs worldwide. As in earlier reviews, only the first approval of any drug is counted, irrespective of how many "biosimilars" or added approvals were subsequently identified. As in the 2012 and 2016 reviews, we have continued to utilize our secondary subdivision of a "natural product mimic", or "NM", to join the original primary divisions, and the designation "natural product botanical", or "NB", to cover those botanical "defined mixtures" now recognized as drug entities by the FDA (and similar organizations). From the data presented in this review, the utilization of natural products and/or synthetic variations using their novel structures, in order to discover and develop the final drug entity, is still alive and well. For example, in the area of cancer, over the time frame from 1946 to 1980, of the 75 small molecules, 40, or 53.3%, are N or ND. In the 1981 to date time frame the equivalent figures for the N* compounds of the 185 small molecules are 62, or 33.5%, though to these can be added the 58 S* and S*/NMs, bringing the figure to 64.9%. In other areas, the influence of natural product structures is quite marked with, as expected from prior information, the anti-infective area being dependent on natural products and their structures, though as can be seen in the review there are still disease areas (shown in Table 2) for which there are no drugs derived from natural products. Although combinatorial chemistry techniques have succeeded as methods of optimizing structures and have been used very successfully in the optimization of many recently approved agents, we are still able to identify only two de novo combinatorial compounds (one of which is a little speculative) approved as drugs in this 39-year time frame, though there is also one drug that was developed using the "fragment-binding methodology" and approved in 2012. We have also added a discussion of candidate drug entities currently in clinical trials as "warheads" and some very interesting preliminary reports on sources of novel antibiotics from Nature due to the absolute requirement for new agents to combat plasmid-borne resistance genes now in the general populace. We continue to draw the attention of readers to the recognition that a significant number of natural product drugs/leads are actually produced by microbes and/or microbial interactions with the "host from whence it was isolated"; thus we consider that this area of natural product research should be expanded significantly.

2,560 citations

01 Jan 2016
TL;DR: In this paper, the authors present the principles of optics electromagnetic theory of propagation interference and diffraction of light, which can be used to find a good book with a cup of coffee in the afternoon, instead of facing with some infectious bugs inside their computer.
Abstract: Thank you for reading principles of optics electromagnetic theory of propagation interference and diffraction of light. As you may know, people have search hundreds times for their favorite novels like this principles of optics electromagnetic theory of propagation interference and diffraction of light, but end up in harmful downloads. Rather than enjoying a good book with a cup of coffee in the afternoon, instead they are facing with some infectious bugs inside their computer.

2,213 citations

Journal ArticleDOI
TL;DR: Although wearable biosensors hold promise, a better understanding of the correlations between analyte concentrations in the blood and noninvasive biofluids is needed to improve reliability.
Abstract: Wearable biosensors are garnering substantial interest due to their potential to provide continuous, real-time physiological information via dynamic, noninvasive measurements of biochemical markers in biofluids, such as sweat, tears, saliva and interstitial fluid. Recent developments have focused on electrochemical and optical biosensors, together with advances in the noninvasive monitoring of biomarkers including metabolites, bacteria and hormones. A combination of multiplexed biosensing, microfluidic sampling and transport systems have been integrated, miniaturized and combined with flexible materials for improved wearability and ease of operation. Although wearable biosensors hold promise, a better understanding of the correlations between analyte concentrations in the blood and noninvasive biofluids is needed to improve reliability. An expanded set of on-body bioaffinity assays and more sensing strategies are needed to make more biomarkers accessible to monitoring. Large-cohort validation studies of wearable biosensor performance will be needed to underpin clinical acceptance. Accurate and reliable real-time sensing of physiological information using wearable biosensor technologies would have a broad impact on our daily lives.

1,579 citations