scispace - formally typeset
Search or ask a question
Author

Tsuyoshi Shiina

Other affiliations: University of Tsukuba
Bio: Tsuyoshi Shiina is an academic researcher from Kyoto University. The author has contributed to research in topics: Imaging phantom & Elastography. The author has an hindex of 27, co-authored 206 publications receiving 5117 citations. Previous affiliations of Tsuyoshi Shiina include University of Tsukuba.


Papers
More filters
Journal ArticleDOI
TL;DR: For assessing breast lesions, US elastography with the proposed imaging classification, which was simple compared with that of the Breast Imaging Recording and Data System classification, had almost the same diagnostic performance as conventional US.
Abstract: Purpose: To evaluate the diagnostic performance of real-time freehand elastography by using the extended combined autocorrelation method (CAM) to differentiate benign from malignant breast lesions, with pathologic diagnosis as the reference standard. Materials and Methods: This study was approved by the University of Tsukuba Human Subjects Institutional Review Board; all patients gave informed consent. Conventional ultrasonography (US) and real-time US elastography with CAM were performed in 111 women (mean age, 49.4 years; age range, 27–91 years) who had breast lesions (59 benign, 52 malignant). Elasticity images were assigned an elasticity score according to the degree and distribution of strain induced by light compression. The area under the curve and cutoff point, both of which were obtained by using a receiver operating characteristic curve analysis, were used to assess diagnostic performance. Mean scores were examined by using a Student t test. Sensitivity, specificity, and accuracy were compared b...

1,534 citations

Journal ArticleDOI
TL;DR: The World Federation for Ultrasound in Medicine and Biology has produced these guidelines for the use of elastography techniques in liver disease, aimed at assessing the usefulness ofElastography in the management of liver diseases.
Abstract: The breast section of these Guidelines and Recommendations for Elastography produced under the auspices of the World Federation of Ultrasound in Medicine and Biology (WFUMB) assesses the clinically used applications of all forms of elastography used in breast imaging. The literature on various breast elastography techniques is reviewed, and recommendations are made on evidence-based results. Practical advice is given on how to perform and interpret breast elastography for optimal results, with emphasis placed on avoiding pitfalls. Artifacts are reviewed, and the clinical utility of some artifacts is discussed. Both strain and shear wave techniques have been shown to be highly accurate in characterizing breast lesions as benign or malignant. The relationship between the various techniques is discussed, and recommended interpretation based on a BI-RADS-like malignancy probability scale is provided. This document is intended to be used as a reference and to guide clinical users in a practical way.

694 citations

Journal ArticleDOI
TL;DR: The fundamental physics and the associated terminology underlying elasticity imaging technologies are described to ensure that the terminology and descriptions are broadly compatible across the WFUMB and EFSUMB sets of guidelines on elastography.
Abstract: Conventional diagnostic ultrasound images of the anatomy (as opposed to blood flow) reveal differences in the acoustic properties of soft tissues (mainly echogenicity but also, to some extent, attenuation), whereas ultrasound-based elasticity images are able to reveal the differences in the elastic properties of soft tissues (e.g., elasticity and viscosity). The benefit of elasticity imaging lies in the fact that many soft tissues can share similar ultrasonic echogenicities but may have different mechanical properties that can be used to clearly visualize normal anatomy and delineate pathologic lesions. Typically, all elasticity measurement and imaging methods introduce a mechanical excitation and monitor the resulting tissue response. Some of the most widely available commercial elasticity imaging methods are 'quasi-static' and use external tissue compression to generate images of the resulting tissue strain (or deformation). In addition, many manufacturers now provide shear wave imaging and measurement methods, which deliver stiffness images based upon the shear wave propagation speed. The goal of this review is to describe the fundamental physics and the associated terminology underlying these technologies. We have included a questions and answers section, an extensive appendix, and a glossary of terms in this manuscript. We have also endeavored to ensure that the terminology and descriptions, although not identical, are broadly compatible across the WFUMB and EFSUMB sets of guidelines on elastography (Bamber et al. 2013; Cosgrove et al. 2013).

685 citations

Journal ArticleDOI
TL;DR: A more useful technique for imaging tissue elasticity, which is called the combined autocorrelation (CA) method, has the advantages of producing strain images of high quality with real-time processing and being applicable to large displacements.
Abstract: The elastic properties of tissues are expected to provide novel information for use in diagnosing pathologic changes in tissues and discriminating between malignant and benign tumors. Because it is hard to directly estimate the elastic modulus distribution from echo signals, methods for imaging the distribution of tissue strain under static compression are being widely investigated. Imaging the distribution of strain has proven to be useful for detecting disease tissues on the basis of their differences in elastic properties, although it is more qualitative than elastic modulus distribution. Many approaches to obtaining strain images from echo signals have been proposed. Most of these approaches use the spatial correlation technique, a method of detecting tissue displacement that provides maximum correlation between the echo signal obtained before and the one obtained after compression. Those methods are not suited for real-time processing, however, because of the amount of computation time they require. An alternative approach is a phase-tracking method, which is analogous to Doppler blood flowmetry. Although it can realize the rapid detection of displacement, the aliasing effect prevents its application to the large displacements that are necessary to improve the S/N ratio of the strain image. We therefore developed a more useful technique for imaging tissue elasticity. This approach, which we call the combined autocorrelation (CA) method, has the advantages of producing strain images of high quality with real-time processing and being applicable to large displacements.

231 citations

Journal ArticleDOI
TL;DR: This clinical study indicated that PAI appears to be a promising tool for noninvasive analysis of human blood vessels and may contribute to improve cancer diagnosis.
Abstract: Noninvasive measurement of the distribution and oxygenation state of hemoglobin (Hb) inside the tissue is strongly required to analyze the tumor-associated vasculatures. We developed a photoacoustic imaging (PAI) system with a hemispherical-shaped detector array (HDA). Here, we show that PAI system with HDA revealed finer vasculature, more detailed blood-vessel branching structures, and more detailed morphological vessel characteristics compared with MRI by the use of breast shape deformation of MRI to PAI and their fused image. Morphologically abnormal peritumoral blood vessel features, including centripetal photoacoustic signals and disruption or narrowing of vessel signals, were observed and intratumoral signals were detected by PAI in breast cancer tissues as a result of the clinical study of 22 malignant cases. Interestingly, it was also possible to analyze anticancer treatment-driven changes in vascular morphological features and function, such as improvement of intratumoral blood perfusion and relevant changes in intravascular hemoglobin saturation of oxygen. This clinical study indicated that PAI appears to be a promising tool for noninvasive analysis of human blood vessels and may contribute to improve cancer diagnosis.

200 citations


Cited by
More filters
Journal ArticleDOI
TL;DR: For assessing breast lesions, US elastography with the proposed imaging classification, which was simple compared with that of the Breast Imaging Recording and Data System classification, had almost the same diagnostic performance as conventional US.
Abstract: Purpose: To evaluate the diagnostic performance of real-time freehand elastography by using the extended combined autocorrelation method (CAM) to differentiate benign from malignant breast lesions, with pathologic diagnosis as the reference standard. Materials and Methods: This study was approved by the University of Tsukuba Human Subjects Institutional Review Board; all patients gave informed consent. Conventional ultrasonography (US) and real-time US elastography with CAM were performed in 111 women (mean age, 49.4 years; age range, 27–91 years) who had breast lesions (59 benign, 52 malignant). Elasticity images were assigned an elasticity score according to the degree and distribution of strain induced by light compression. The area under the curve and cutoff point, both of which were obtained by using a receiver operating characteristic curve analysis, were used to assess diagnostic performance. Mean scores were examined by using a Student t test. Sensitivity, specificity, and accuracy were compared b...

1,534 citations

Journal ArticleDOI
TL;DR: The technical part of these Guidelines and Recommendations provides an introduction to the physical principles and technology on which all forms of current commercially available ultrasound elastography are based.
Abstract: The technical part of these Guidelines and Recommendations, produced under the auspices of EFSUMB, provides an introduction to the physical principles and technology on which all forms of current commercially available ultrasound elastography are based. A difference in shear modulus is the common underlying physical mechanism that provides tissue contrast in all elastograms. The relationship between the alternative technologies is considered in terms of the method used to take advantage of this. The practical advantages and disadvantages associated with each of the techniques are described, and guidance is provided on optimisation of scanning technique, image display, image interpretation and some of the known image artefacts.

1,020 citations

Journal ArticleDOI
TL;DR: While ultrasound elastography has shown promising results for non-invasive assessment of liver fibrosis, new applications in breast, thyroid, prostate, kidney and lymph node imaging are emerging.
Abstract: Elastography-based imaging techniques have received substantial attention in recent years for non-invasive assessment of tissue mechanical properties. These techniques take advantage of changed soft tissue elasticity in various pathologies to yield qualitative and quantitative information that can be used for diagnostic purposes. Measurements are acquired in specialized imaging modes that can detect tissue stiffness in response to an applied mechanical force (compression or shear wave). Ultrasound-based methods are of particular interest due to its many inherent advantages, such as wide availability including at the bedside and relatively low cost. Several ultrasound elastography techniques using different excitation methods have been developed. In general, these can be classified into strain imaging methods that use internal or external compression stimuli, and shear wave imaging that use ultrasound-generated traveling shear wave stimuli. While ultrasound elastography has shown promising results for non-invasive assessment of liver fibrosis, new applications in breast, thyroid, prostate, kidney and lymph node imaging are emerging. Here, we review the basic principles, foundation physics, and limitations of ultrasound elastography and summarize its current clinical use and ongoing developments in various clinical applications.

995 citations

Journal ArticleDOI
TL;DR: The final recommendations recognize that obesity is a complex, adiposity-based chronic disease, where management targets both weight-related complications and adiposity to improve overall health and quality of life.

978 citations

Journal ArticleDOI
TL;DR: The clinical part of these Guidelines and Recommendations produced under the auspices of the European Federation of Societies for Ultrasound in Medicine and Biology EFSUMB assesses the clinically used applications of all forms of elastography, stressing the evidence from meta-analyses and giving practical advice for their uses and interpretation.
Abstract: The clinical part of these Guidelines and Recommendations produced under the auspices of the European Federation of Societies for Ultrasound in Medicine and Biology EFSUMB assesses the clinically used applications of all forms of elastography, stressing the evidence from meta-analyses and giving practical advice for their uses and interpretation. Diffuse liver disease forms the largest section, reflecting the wide experience with transient and shear wave elastography . Then follow the breast, thyroid, gastro-intestinal tract, endoscopic elastography, the prostate and the musculo-skeletal system using strain and shear wave elastography as appropriate. The document is intended to form a reference and to guide clinical users in a practical way.

830 citations