scispace - formally typeset
Search or ask a question
Author

X. Y. Wu

Bio: X. Y. Wu is an academic researcher from Brookhaven National Laboratory. The author has contributed to research in topics: Imaging phantom & Monochromator. The author has an hindex of 8, co-authored 12 publications receiving 815 citations.

Papers
More filters
Journal ArticleDOI
TL;DR: Adult‐rat‐brain tissues display an unusually high resistance to necrosis when serially irradiated with parallel, thin slices of a microplanar beam of synchrotron‐wiggler‐generated X rays, and correlation with radiation doses shows that loss of tissue structure was confined to beam‐crossing regions and that only minor damage was done to zones of the brain irradiated unidirectionally.
Abstract: Adult-rat-brain tissues display an unusually high resistance to necrosis when serially irradiated with parallel, thin slices of a microplanar (i.e., microscopically thin and macroscopically broad) beam of synchrotron-wiggler-generated, approx. 35-120 keV (median approx. 50 keV) Gd-filtered X rays at skin-entrance absorbed doses of 312 to 5000 Gy per slice. Such microplanar beams were used to irradiate young adult rats bearing right frontocerebral 9L gliosarcomas (approx. 4 mm diameter), through a volume of tissue containing the tumor and contiguous brain tissue, either in a single array or in 2 orthogonally crossed arrays of tissue slices. Each array included 101 parallel microplanar slices, 100 microm center-to-center distance, each slice being approx. 25 microm wide and 12 mm high, with skin-entrance absorbed doses of 312.5 Gy or 625 Gy per slice. Compared with unirradiated controls with a median survival time of 20 days after tumor initiation, the median survival time was extended in irradiated rats by 139 days (625 Gy, crossed arrays), 96 days (312 Gy, crossed arrays) or 24 days (625 Gy, single array). The tumors disappeared in 22 of the 36 irradiated rats, 4/11 even after unidirectional microbeam irradiation. The extent and severity of radiation damage to the normal brain in rats with or without tumor was graded histopathologically. Correlation of those grades with radiation doses shows that loss of tissue structure was confined to beam-crossing regions and that only minor damage was done to zones of the brain irradiated unidirectionally.

282 citations

Journal ArticleDOI
TL;DR: Diffraction enhanced imaging is a new, synchrotron-based, x-ray radiography method that uses monochromatic, fan-shaped beams, with an analyser crystal positioned between the subject and the detector, and has the potential for use in clinical radiography and in industry.
Abstract: Diffraction enhanced imaging (DEI) is a new, synchrotron-based, x-ray radiography method that uses monochromatic, fan-shaped beams, with an analyser crystal positioned between the subject and the detector. The analyser allows the detection of only those x-rays transmitted by the subject that fall into the acceptance angle (central part of the rocking curve) of the monochromator/analyser system. As shown by Chapman et al, in addition to the x-ray attenuation, the method provides information on the out-of-plane angular deviation of x-rays. New images result in which the image contrast depends on the x-ray index of refraction and on the yield of small-angle scattering, respectively. We implemented DEI in the tomography mode at the National Synchrotron Light Source using 22 keV x-rays, and imaged a cylindrical acrylic phantom that included oil-filled, slanted channels. The resulting 'refraction CT image' shows the pure image of the out-of-plane gradient of the x-ray index of refraction. No image artefacts were present, indicating that the CT projection data were a consistent set. The 'refraction CT image' signal is linear with the gradient of the refractive index, and its value is equal to that expected. The method, at the energy used or higher, has the potential for use in clinical radiography and in industry.

258 citations

Journal ArticleDOI
TL;DR: The potential for clinical research of computed tomography (CT) with monochromatic x-rays using the preclinical multiple energy computed tomographic (MECT) system at the National Synchrotron Light Source is explored.
Abstract: We explored the potential for clinical research of computed tomography (CT) with monochromatic x-rays using the preclinical multiple energy computed tomography (MECT) system at the National Synchrotron Light Source. MECT has a fixed, horizontal fan beam with a subject apparatus rotating about a vertical axis; it will be used for imaging the human head and neck. Two -photodiode array detectors with different spatial resolutions were used. A 10.5 cm diameter acrylic phantom was imaged with MECT at 43 keV and with a conventional CT (CCT) at 80 kVp: spatial resolution line pairs (lp)/cm for both; slice height, 2.6 mm for MECT against 3.0 mm for CCT; surface dose, 3.1 cGy for MECT against 2.0 cGy for CCT. The resultant image noise was 1.5 HU for MECT against 3 HU for CCT. Computer simulations of the same images with more precisely matched spatial resolution, slice height and dose indicated an image - noise ratio of 1.4:1.0 for CCT against MECT. A 13.5 cm diameter acrylic phantom imaged with MECT at above the iodine K edge and with CCT showed, for a solution, an image contrast of 26 HU for MECT and 13 and 9 HU for the 80 and 100 kVp CCT, respectively. The corresponding numbers from computer simulation of the same images were 26, 12, and 9 HU, respectively. MECT's potential for use in clinical research is discussed.

121 citations

Journal Article
TL;DR: Brain tolerance was estimated to be about three times higher to microbeam irradiation as compared with broad beam irradiation, as compared to the broad beam modality.
Abstract: Duck embryo was studied as a model for assessing the effects of microbeam radiation therapy (MRT) on the human infant brain. Because of the high risk of radiation-induced disruption of the developmental process in the immature brain, conventional wide-beam radiotherapy of brain tumors is seldom carried out in infants under the age of three. Other types of treatment for pediatric brain tumors are frequently ineffective. Recent findings from studies in Grenoble on the brain of suckling rats indicate that MRT could be of benefit for the treatment of early childhood tumors. In our studies, duck embryos were irradiated at 3-4 days prior to hatching. Irradiation was carried out using a single exposure of synchrotron-generated X-rays, either in the form of parallel microplanar beams (microbeams), or as non-segmented broad beam. The individual microplanar beams had a width of 27 microm and height of 11 mm, and a center-to-center spacing of 100 microm. Doses to the exposed areas of embryo brain were 40, 80, 160 and 450 Gy (in-slice dose) for the microbeam, and 6, 12 and 18 Gy for the broad beam. The biological end point employed in the study was ataxia. This neurological symptom of radiation damage to the brain developed within 75 days of hatching. Histopathological analysis of brain tissue did not reveal any radiation induced lesions for microbeam doses of 40-160 Gy (in-slice), although some incidences of ataxia were observed in that dose group. However, severe brain lesions did occur in animals in the 450 Gy microbeam dose groups, and mild lesions in the 18 Gy broad beam dose group. These results indicate that embryonic duck brain has an appreciably higher tolerance to the microbeam modality, as compared to the broad beam modality. When the microbeam dose was normalized to the full volume of the irradiated tissue. i.e., the dose averaged over microbeams and the space between the microbeams, brain tolerance was estimated to be about three times higher to microbeam irradiation as compared with broad beam irradiation.

107 citations

Journal ArticleDOI
TL;DR: The status of the synchrotron-based computed tomography (MECT) system is described in this paper, which uses monochromatic beams from the X17 superconducting wiggler beam line for imaging the human head and neck.
Abstract: Status of the synchrotron‐based computed tomography system, called multiple energy computed tomography (MECT), is described. MECT, that uses monochromatic beams from the X17 superconducting wiggler beam line at the National Synchrotron Light Source, will be used for imaging the human head and neck. An earlier prototype MECT produced images of phantoms and living rodents. This report summarizes the studies with the prototype, and describes the design, construction, and test results of the clinical MECT system components.

15 citations


Cited by
More filters
01 Jan 2000
TL;DR: This annex is aimed at providing a sound basis for conclusions regarding the number of significant radiation accidents that have occurred, the corresponding levels of radiation exposures and numbers of deaths and injuries, and the general trends for various practices, in the context of the Committee's overall evaluations of the levels and effects of exposure to ionizing radiation.
Abstract: NOTE The report of the Committee without its annexes appears as Official Records of the General Assembly, Sixty-third Session, Supplement No. 46. The designations employed and the presentation of material in this publication do not imply the expression of any opinion whatsoever on the part of the Secretariat of the United Nations concerning the legal status of any country, territory, city or area, or of its authorities, or concerning the delimitation of its frontiers or boundaries. The country names used in this document are, in most cases, those that were in use at the time the data were collected or the text prepared. In other cases, however, the names have been updated, where this was possible and appropriate, to reflect political changes. Scientific Annexes Annex A. Medical radiation exposures Annex B. Exposures of the public and workers from various sources of radiation INTROdUCTION 1. In the course of the research and development for and the application of atomic energy and nuclear technologies, a number of radiation accidents have occurred. Some of these accidents have resulted in significant health effects and occasionally in fatal outcomes. The application of technologies that make use of radiation is increasingly widespread around the world. Millions of people have occupations related to the use of radiation, and hundreds of millions of individuals benefit from these uses. Facilities using intense radiation sources for energy production and for purposes such as radiotherapy, sterilization of products, preservation of foodstuffs and gamma radiography require special care in the design and operation of equipment to avoid radiation injury to workers or to the public. Experience has shown that such technology is generally used safely, but on occasion controls have been circumvented and serious radiation accidents have ensued. 2. Reviews of radiation exposures from accidents have been presented in previous UNSCEAR reports. The last report containing an exclusive chapter on exposures from accidents was the UNSCEAR 1993 Report [U6]. 3. This annex is aimed at providing a sound basis for conclusions regarding the number of significant radiation accidents that have occurred, the corresponding levels of radiation exposures and numbers of deaths and injuries, and the general trends for various practices. Its conclusions are to be seen in the context of the Committee's overall evaluations of the levels and effects of exposure to ionizing radiation. 4. The Committee's evaluations of public, occupational and medical diagnostic exposures are mostly concerned with chronic exposures of …

3,924 citations

Journal ArticleDOI
TL;DR: This article cites 228 articles, 79 of which can be accessed free at: service Email alerting click here top right corner of the article or Receive free email alerts when new articles cite this article sign up in the box at the Collections Topic.
Abstract: References http://genesdev.cshlp.org/content/17/5/545.full.html#related-urls Article cited in: http://genesdev.cshlp.org/content/17/5/545.full.html#ref-list-1 This article cites 228 articles, 79 of which can be accessed free at: service Email alerting click here top right corner of the article or Receive free email alerts when new articles cite this article sign up in the box at the Collections Topic (33 articles) Molecular Physiology and Metabolism • (98 articles) Cancer and Disease Models • Articles on similar topics can be found in the following collections

2,282 citations

Journal ArticleDOI
TL;DR: Gold nanoparticles can be used as X-ray contrast agents with properties that overcome some significant limitations of iodine-based agents, and this report is the first demonstration that gold nanoparticles may overcome these limitations.
Abstract: There have been few fundamental improvements in clinical X-ray contrast agents in more than 25 years, and the chemical platform of tri-iodobenzene has not changed. Current agents impose serious limitations on medical imaging: short imaging times, the need for catheterization in many cases, occasional renal toxicity, and poor contrast in large patients. This report is the first demonstration that gold nanoparticles may overcome these limitations. Gold has higher absorption than iodine with less bone and tissue interference achieving better contrast with lower X-ray dose. Nanoparticles clear the blood more slowly than iodine agents, permitting longer imaging times. Gold nanoparticles, 1.9 nm in diameter, were injected intravenously into mice and images recorded over time with a standard mammography unit. Gold biodistribution was measured by atomic absorption. Retention in liver and spleen was low with elimination by the kidneys. Organs such as kidneys and tumours were seen with unusual clarity and high spatial resolution. Blood vessels less than 100 mm in diameter were delineated, thus enabling in vivo vascular casting. Regions of increased vascularization and angiogenesis could be distinguished. With 10 mg Au ml 21 initially in the blood, mouse behaviour was unremarkable and neither blood plasma analytes nor organ histology revealed any evidence of toxicity 11 days and 30 days after injection. Gold nanoparticles can be used as X-ray contrast agents with properties that overcome some significant limitations of iodine-based agents.

1,238 citations

Journal ArticleDOI
TL;DR: In this paper, the advantages of using X-ray phase information and reviews various techniques studied for Xray phase imaging are described, and the authors describe the advantages and disadvantages of using this information.
Abstract: Since the middle of the 1990s, X-ray phase imaging including phase tomography has been attracting increasing attention. The advantage of X-ray phase imaging is that an extremely high sensitivity is achieved for weak-absorbing materials, such as biological soft tissues, which generate a poor contrast by conventional methods. Medical and biological imaging is the main target of X-ray phase imaging, and several trials using synchrotron radiation sources and laboratory sources have been made. Measuring and controlling the X-ray phase are also significant for X-ray microscopy with a high spatial resolution, and innovative techniques are attracting intense interest. The progress of X-ray phase imaging is supported by the developments in X-ray sources such as third-generation synchrotron radiation sources, optical elements, and image detectors. This article describes the advantages of using X-ray phase information and reviews various techniques studied for X-ray phase imaging.

515 citations

Journal ArticleDOI
TL;DR: The charge of Task Group 186 (TG-186) is to provide guidance for early adopters of model-based dose calculation algorithms (MBDCAs) for brachytherapy (BT) dose calculations to ensure practice uniformity, with explicit recommendations based on the current state of knowledge.
Abstract: The charge of Task Group 186 (TG-186) is to provide guidance for early adopters of model-based dose calculation algorithms (MBDCAs) for brachytherapy (BT) dose calculations to ensure practice uniformity. Contrary to external beam radiotherapy, heterogeneity correction algorithms have only recently been made available to the BT community. Yet, BT dose calculation accuracy is highly dependent on scatter conditions and photoelectric effect cross-sections relative to water. In specific situations, differences between the current water-based BT dose calculation formalism (TG-43) and MBDCAs can lead to differences in calculated doses exceeding a factor of 10. MBDCAs raise three major issues that are not addressed by current guidance documents: (1) MBDCA calculated doses are sensitive to the dose specification medium, resulting in energy-dependent differences between dose calculated to water in a homogeneous water geometry (TG-43), dose calculated to the local medium in the heterogeneous medium, and the intermediate scenario of dose calculated to a small volume of water in the heterogeneous medium. (2) MBDCA doses are sensitive to voxel-by-voxel interaction cross sections. Neither conventional single-energy CT nor ICRU∕ICRP tissue composition compilations provide useful guidance for the task of assigning interaction cross sections to each voxel. (3) Since each patient-source-applicator combination is unique, having reference data for each possible combination to benchmark MBDCAs is an impractical strategy. Hence, a new commissioning process is required. TG-186 addresses in detail the above issues through the literature review and provides explicit recommendations based on the current state of knowledge. TG-43-based dose prescription and dose calculation remain in effect, with MBDCA dose reporting performed in parallel when available. In using MBDCAs, it is recommended that the radiation transport should be performed in the heterogeneous medium and, at minimum, the dose to the local medium be reported along with the TG-43 calculated doses. Assignments of voxel-by-voxel cross sections represent a particular challenge. Electron density information is readily extracted from CT imaging, but cannot be used to distinguish between different materials having the same density. Therefore, a recommendation is made to use a number of standardized materials to maintain uniformity across institutions. Sensitivity analysis shows that this recommendation offers increased accuracy over TG-43. MBDCA commissioning will share commonalities with current TG-43-based systems, but in addition there will be algorithm-specific tasks. Two levels of commissioning are recommended: reproducing TG-43 dose parameters and testing the advanced capabilities of MBDCAs. For validation of heterogeneity and scatter conditions, MBDCAs should mimic the 3D dose distributions from reference virtual geometries. Potential changes in BT dose prescriptions and MBDCA limitations are discussed. When data required for full MBDCA implementation are insufficient, interim recommendations are made and potential areas of research are identified. Application of TG-186 guidance should retain practice uniformity in transitioning from the TG-43 to the MBDCA approach.

418 citations