scispace - formally typeset
Search or ask a question
Author

Y. Funahashi

Bio: Y. Funahashi is an academic researcher. The author has contributed to research in topics: Collider. The author has an hindex of 2, co-authored 3 publications receiving 30 citations.
Topics: Collider

Papers
More filters
Proceedings ArticleDOI
27 Mar 1999
TL;DR: In this article, a new type of damped detuned structure with optimized round-shaped cavities (RDDS) was proposed for X-band accelerator structures for the JLC/NLC linear collider.
Abstract: For more than ten years, we have been working on R&D for X-band accelerator structures for the JLC/NLC linear collider. Several types of Detuned (DS) and Damped Detuned Structures (DDS) have been successfully designed and fabricated. They have been experimentally tested at both low power and high power to characterize their mechanical and electrical properties. Recently we started developing a new type of damped detuned structure with optimized round-shaped cavities (RDDS). This paper discusses the special specifications, design methods, fabrication procedures, measurement technologies, and anticipated future improvements for all these structures.

27 citations

Proceedings ArticleDOI
01 Mar 1999
TL;DR: A 1.8 m X-band damped-detuned structure (DDS-3) has been fabricated and characterized as part of the structure development program towards a TeV-scale e/sup +/e/sup -/ linear collider.
Abstract: A 1.8 m X-band damped-detuned structure (DDS-3) has been fabricated and characterized as part of the structure development program towards a TeV-scale e/sup +/e/sup -/ linear collider. In this joint venture, the Cu cells were precision-fabricated by LLNL, diffusion-bonded into a monolithic structure by KEK, and the structure completed and tested by SLAC. The overall process constitutes a baseline for future high-volume structure manufacture.

4 citations

Posted Content
TL;DR: In this paper, the Rounded Damped Detuned Structures (RDDS) with curved cross-section of the cavity shape for increased shunt impedance were fabricated and used for the JLC/NLC linear collider project.
Abstract: Following the successful design and fabrication of Damped Detuned Structures (DDS), the JLC/NLC linear collider project advanced to Rounded Damped Detuned Structures (RDDS) with curved cross section of the cavity shape for increased shunt impedance. Various advanced techniques for fabricating RDDS1 disks comparing to those for DDS were established to satisfy the dimension accuracy of +-1 micron over the entire surface made by ultra-precision turning. These disks were assembled with almost the same stacking and bonding jigs and processes as those of DDS3 assembly. In consequence, the assembly showed little disk-to-disk misalignment within 1 micron before and after the process. Though, it had 200 micron smooth bowing, which was subsequently corrected as DDS3, and flares at both ends.

Cited by
More filters
Proceedings ArticleDOI
S.M. Hanna1
27 Mar 1999
TL;DR: The X-band accelerator technology has been used in high-energy as well as industrial applications as discussed by the authors and it is already implemented in some machines, such as the Mobetron an Intra-Operative Radiation Therapy (IORT) treatment system.
Abstract: Most radiation therapy machines are based on microwave linear accelerators. The majority of medical accelerators use frequencies in the S-band range. Having a compact accelerator allows for a wide range of treatments. The size and weight of the accelerator is substantially reduced if a higher frequency is used. X-band frequencies are suitable for such applications. The X-band accelerator technology has been used in high-energy as well as industrial applications. In the radiation therapy field, it is already implemented in some machines. The Mobetron an Intra-Operative Radiation Therapy (IORT) treatment system is one example. Another example is the Stereotactic Radiosurgery machine, the CyberKnife. The compactness of these machines required the use of an X-band accelerator. The basis for choosing the X-band technology in some of the medical machines is analysed. A review of the exiting medical applications is included. We also discuss the availability of other X-band components in the machine, including high-power RF sources.

18 citations

Proceedings ArticleDOI
TL;DR: The Next Linear Collider (NLC) is being designed by a US collaboration (FNAL, LBNL, LLNL, and SLAC) which is working closely with the Japanese collaboration that is designing the Japanese linear Collider (JLC) as discussed by the authors.
Abstract: An electron/positron linear collider with a center-of-mass energy between 0.5 and 1 TeV would be an important complement to the physics program of the LHC. The Next Linear Collider (NLC) is being designed by a US collaboration (FNAL, LBNL, LLNL, and SLAC) which is working closely with the Japanese collaboration that is designing the Japanese Linear Collider (JLC). The NLC main linacs are based on normal conducting 11 GHz rf. This paper will discuss the technical difficulties encountered as well as the many changes that have been made to the NLC design over the last year. These changes include improvements to the X-band rf system as well as modifications to the injector and the beam delivery system. They are based on new conceptual solutions as well as results from the R&D programs which have exceeded initial specifications. The net effect has been to reduce the length of the collider from about 32 km to 25 km and to reduce the number of klystrons and modulators by a factor of two. Together these lead to s...

12 citations

DOI
01 Jul 2014
TL;DR: Dogan et al. as discussed by the authors presented a paper at the 5th International Particle Accelerator Conference (IPAC 2014) in Dresden, Germany, 15 June 2014 through 20 June 2014.
Abstract: Dogan, Mustafa (Dogus Author) -- Conference full title: 5th International Particle Accelerator Conference, IPAC 2014; International Congress Center DresdenDresden; Germany; 15 June 2014 through 20 June 2014.

11 citations

Posted Content
TL;DR: In this paper, it is shown that simple values that characterize the detuning of the cells can be introduced only for the disc-loaded waveguide with parameters that change very slow.
Abstract: On the base of general approach we obtain some results that can be useful in the process of tuning of nonunifrom disc-loaded waveguides Our consideration has shown that simple values that characterize the detuning of the cells can be introduced only for the disc-loaded waveguide with parameters that change very slow In general case it is needed to conduct full numerical simulation of specific disc-loaded waveguide and obtain all necessary coupling coefficients After that one can start the tuning process on the base of bead-pull field distribution measurements

9 citations

Proceedings Article
01 Jan 2014
TL;DR: In this paper, a linear accelerating structure with an average loaded gradient of 100 MV/m at X-band frequencies has been demonstrated in the CLIC study, and the structure choice and conceptual design parameters of a facility which could generate laser photon pulses below Angstrom are presented.
Abstract: A linear accelerating structure with an average loaded gradient of 100 MV/m at X-Band frequencies has been demonstrated in the CLIC study. Recently, it has been proposed to use this structure to drive an FEL linac. In contrast to CLIC the linac would be powered by klystrons not by an RF source created by a drive beam. The main advantage of this proposal is achieving the required energies in a very short distance, thus the facility would be rather compact. In this study, we present the structure choice and conceptual design parameters of a facility which could generate laser photon pulses below Angstrom. Shorter wavelengths can also be reached with slightly increasing the energy.

5 citations