scispace - formally typeset
Search or ask a question
Author

Yali Jia

Other affiliations: University of Washington
Bio: Yali Jia is an academic researcher from Oregon Health & Science University. The author has contributed to research in topics: Optical coherence tomography & Angiography. The author has an hindex of 49, co-authored 236 publications receiving 13061 citations. Previous affiliations of Yali Jia include University of Washington.


Papers
More filters
Journal ArticleDOI
TL;DR: In this paper, a split-spectrum amplitude-decorrelation angiography (SSADA) was proposed to improve the signal-to-noise ratio (SNR) of flow detection.
Abstract: Amplitude decorrelation measurement is sensitive to transverse flow and immune to phase noise in comparison to Doppler and other phase-based approaches. However, the high axial resolution of OCT makes it very sensitive to the pulsatile bulk motion noise in the axial direction. To overcome this limitation, we developed split-spectrum amplitude-decorrelation angiography (SSADA) to improve the signal-to-noise ratio (SNR) of flow detection. The full OCT spectrum was split into several narrower bands. Inter-B-scan decorrelation was computed using the spectral bands separately and then averaged. The SSADA algorithm was tested on in vivo images of the human macula and optic nerve head. It significantly improved both SNR for flow detection and connectivity of microvascular network when compared to other amplitude-decorrelation algorithms.

1,507 citations

Journal Article
TL;DR: In this paper, a split-spectrum amplitude-decorrelation angiography (SSADA) was proposed to improve the signal-to-noise ratio (SNR) of flow detection.
Abstract: Amplitude decorrelation measurement is sensitive to transverse flow and immune to phase noise in comparison to Doppler and other phase-based approaches. However, the high axial resolution of OCT makes it very sensitive to the pulsatile bulk motion noise in the axial direction. To overcome this limitation, we developed split-spectrum amplitude-decorrelation angiography (SSADA) to improve the signal-to-noise ratio (SNR) of flow detection. The full OCT spectrum was split into several narrower bands. Inter-B-scan decorrelation was computed using the spectral bands separately and then averaged. The SSADA algorithm was tested on in vivo images of the human macula and optic nerve head. It significantly improved both SNR for flow detection and connectivity of microvascular network when compared to other amplitude-decorrelation algorithms.

1,151 citations

Journal ArticleDOI
TL;DR: Optical coherence tomography angiography provides depth-resolved information and detailed images of CNV in neovascular AMD and provides more distinct vascular network patterns that were less obscured by subretinal hemorrhage.

636 citations

Journal ArticleDOI
TL;DR: Optical coherence tomography angiography, generated by the new SSADA, repeatably measures optic disc perfusion and may be useful in the evaluation of glaucoma and glAUcoma progression.

595 citations

Journal ArticleDOI
TL;DR: OCTAngiography shows promise as a noninvasive alternative to dye-based angiography for highly detailed, in vivo, 3D, quantitative evaluation of retinal vascular abnormalities.
Abstract: Retinal vascular diseases are important causes of vision loss. A detailed evaluation of the vascular abnormalities facilitates diagnosis and treatment in these diseases. Optical coherence tomography (OCT) angiography using the highly efficient split-spectrum amplitude decorrelation angiography algorithm offers an alternative to conventional dye-based retinal angiography. OCT angiography has several advantages, including 3D visualization of retinal and choroidal circulations (including the choriocapillaris) and avoidance of dye injection-related complications. Results from six illustrative cases are reported. In diabetic retinopathy, OCT angiography can detect neovascularization and quantify ischemia. In age-related macular degeneration, choroidal neovascularization can be observed without the obscuration of details caused by dye leakage in conventional angiography. Choriocapillaris dysfunction can be detected in the nonneovascular form of the disease, furthering our understanding of pathogenesis. In choroideremia, OCT's ability to show choroidal and retinal vascular dysfunction separately may be valuable in predicting progression and assessing treatment response. OCT angiography shows promise as a noninvasive alternative to dye-based angiography for highly detailed, in vivo, 3D, quantitative evaluation of retinal vascular abnormalities.

583 citations


Cited by
More filters
Journal ArticleDOI
28 Jan 2020-ACS Nano
TL;DR: Prominent authors from all over the world joined efforts to summarize the current state-of-the-art in understanding and using SERS, as well as to propose what can be expected in the near future, in terms of research, applications, and technological development.
Abstract: The discovery of the enhancement of Raman scattering by molecules adsorbed on nanostructured metal surfaces is a landmark in the history of spectroscopic and analytical techniques. Significant experimental and theoretical effort has been directed toward understanding the surface-enhanced Raman scattering (SERS) effect and demonstrating its potential in various types of ultrasensitive sensing applications in a wide variety of fields. In the 45 years since its discovery, SERS has blossomed into a rich area of research and technology, but additional efforts are still needed before it can be routinely used analytically and in commercial products. In this Review, prominent authors from around the world joined together to summarize the state of the art in understanding and using SERS and to predict what can be expected in the near future in terms of research, applications, and technological development. This Review is dedicated to SERS pioneer and our coauthor, the late Prof. Richard Van Duyne, whom we lost during the preparation of this article.

1,768 citations

01 Jan 1980

1,523 citations

Journal Article
TL;DR: In this article, optical coherence tomography is used for high-resolution, noninvasive imaging of the human retina, including the macula and optic nerve head in normal human subjects.
Abstract: Objective: To demonstrate optical coherence tomography for high-resolution, noninvasive imaging of the human retina. Optical coherence tomography is a new imaging technique analogous to ultrasound B scan that can provide cross-sectional images of the retina with micrometer-scale resolution. Design: Survey optical coherence tomographic examination of the retina, including the macula and optic nerve head in normal human subjects. Settings Research laboratory. Participants: Convenience sample of normal human subjects. Main Outcome Measures: Correlation of optical coherence retinal tomographs with known normal retinal anatomy. Results: Optical coherence tomographs can discriminate the cross-sectional morphologic features of the fovea and optic disc, the layered structure of the retina, and normal anatomic variations in retinal and retinal nerve fiber layer thicknesses with 10- μm depth resolution. Conclusion: Optical coherence tomography is a potentially useful technique for high depth resolution, cross-sectional examination of the fundus.

1,409 citations

Journal ArticleDOI
TL;DR: In none of the 12 eyes could the radial peripapillary capillary network be visualized completely around the nerve head by fluorescein angiography, whereas the network was readily visualized in the SSADA scans.
Abstract: Importance The retinal vasculature is involved in many ocular diseases that cause visual loss. Although fluorescein angiography is the criterion standard for evaluating the retina vasculature, it has risks of adverse effects and known defects in imaging all the layers of the retinal vasculature. Optical coherence tomography (OCT) angiography can image vessels based on flow characteristics and may provide improved information. Objective To investigate the ability of OCT angiography to image the vascular layers within the retina compared with conventional fluorescein angiography. Design, Setting, and Participants In this study, performed from March 14, 2014, through June 24, 2014, a total of 5 consecutive, overlapping B-scan OCT angiography images composed of 216 A-scans were obtained at 216 discrete positions within a region of interest, typically a 2 × 2-mm area of the retina. The flow imaging was based on split-spectrum amplitude decorrelation angiography (SSADA), which can dissect layers of vessels in the retina. These distinct layers were compared with the fluorescein angiograms in 12 healthy eyes from patients at a private practice retina clinic to evaluate the ability to visualize the radial peripapillary capillary network. The proportion of the inner vs outer retinal vascular layers was estimated by 3 masked readers and compared with conventional fluorescein angiograms of the same eyes. Main Outcomes and Measures Outcome measures were visualization of the radial peripapillary capillary network in the fluorescein and SSADA scans and the proportion of the inner retinal vascular plexus vs the outer retinal capillary plexus as seen in SSADA scans that would match the fluorescein angiogram. Results In none of the 12 eyes could the radial peripapillary capillary network be visualized completely around the nerve head by fluorescein angiography, whereas the network was readily visualized in the SSADA scans. The fluorescein angiograms were matched, with a mean proportion of the inner vascular plexus being 95.3% (95% CI, 92.2%-97.8%) vs 4.7% (95% CI, 2.6%-5.7%) for the outer capillary plexus from the SSADA scans. Conclusions and Relevance Fluorescein angiography does not image the radial peripapillary or the deep capillary networks well. However, OCT angiography can image all layers of the retinal vasculature without dye injection. Therefore, OCT angiography, and the findings generated, have the potential to affect clinical evaluation of the retina in healthy patients and patients with disease.

1,322 citations

Journal Article
TL;DR: In this article, the diffraction tomography theorem is adapted to one-dimensional length measurement and the resulting spectral interferometry technique is described and the first length measurements using this technique on a model eye and on a human eye in vivo are presented.
Abstract: The diffraction tomography theorem is adapted to one-dimensional length measurement. The resulting spectral interferometry technique is described and the first length measurements using this technique on a model eye and on a human eye in vivo are presented.

1,237 citations