scispace - formally typeset
Search or ask a question
Author

Yasuhiro Yoshida

Bio: Yasuhiro Yoshida is an academic researcher from Hokkaido University. The author has contributed to research in topics: Dentin & Dental bonding. The author has an hindex of 58, co-authored 304 publications receiving 15681 citations. Previous affiliations of Yasuhiro Yoshida include Mitsubishi Electric & Hiroshima University.


Papers
More filters
Journal Article
TL;DR: The basic bonding mechanism to enamel and dentin of these three approaches is demonstrated by means of ultramorphological and chemical characterization of tooth-biomaterial interfacial interactions and confirms that conventional three-step etch&rinse adhesives still perform most favorably and are most reliable in the long-term.
Abstract: Bonding to tooth tissue can be achieved through an "etch&rinse," "self-etch" or "glass-ionomer" approach. In this paper, the basic bonding mechanism to enamel and dentin of these three approaches is demonstrated by means of ultramorphological and chemical characterization of tooth-biomaterial interfacial interactions. Furthermore, bond-strength testing and measurement of marginal-sealing effectiveness (the two most commonly employed methodologies to determine "bonding effectiveness" in the laboratory) are evaluated upon their value and relevance in predicting clinical performance. A new dynamic methodology to test biomaterial-tooth bonds in a fatigue mode is introduced with a recently developed micro-rotary fatigue-testing device. Eventually, today's adhesives will be critically weighted upon their performance in diverse laboratory studies and clinical trials. Special attention has been given to the benefits/drawbacks of an etch&rinse versus a self-etch approach and the long-term performance of these adhesives. Correlating data gathered in the laboratory with clinical results clearly showed that laboratory research CAN predict clinical effectiveness. Although there is a tendency to simplify bonding procedures, the data presented confirm that conventional three-step etch&rinse adhesives still perform most favorably and are most reliable in the long-term. Nevertheless, a self-etch approach may have the best future perspective. Clinically, when adhesives no longer require an "etch&rinse" step, the application time, and probably more importantly, the technique-sensitivity are substantially reduced. Especially "mild," two-step self-etch adhesives that bond through a combined micromechanical and chemical interaction with tooth tissue closely approach conventional three-step systems in bonding performance.

1,721 citations

Journal ArticleDOI
TL;DR: The aim of this article is to systematically review the ingredients commonly used in current dental adhesives as well as the properties of these ingredients.

1,218 citations

Journal ArticleDOI
TL;DR: The major shortcomings of the most simple-to-use one-step (self-etch) adhesives are addressed and special attention is devoted to the AD-concept and the benefit of chemical interfacial interaction with regard to bond durability.

1,059 citations

Journal ArticleDOI
TL;DR: Besides self-etching dentin, specific functional monomers have additional chemical bonding efficacy that is expected to contribute to their adhesive potential to tooth tissue.
Abstract: Mild self-etch adhesives demineralize dentin only partially, leaving hydroxyapatite around collagen within a submicron hybrid layer. We hypothesized that this residual hydroxyapatite may serve as a receptor for chemical interaction with the functional monomer and, subsequently, contribute to adhesive performance in addition to micro-mechanical hybridization. We therefore chemically characterized the adhesive interaction of 3 functional monomers with synthetic hydroxyapatite, using x-ray photoelectron spectroscopy and atomic absorption spectrophotometry. We further characterized their interaction with dentin ultra-morphologically, using transmission electron microscopy. The monomer 10-methacryloxydecyl dihydrogen phosphate (10-MDP) readily adhered to hydroxyapatite. This bond appeared very stable, as confirmed by the low dissolution rate of its calcium salt in water. The bonding potential of 4-methacryloxyethyl trimellitic acid (4-MET) was substantially lower. The monomer 2-methacryloxyethyl phenyl hydrogen phosphate (phenyl-P) and its bond to hydroxyapatite did not appear to be hydrolytically stable. Besides self-etching dentin, specific functional monomers have additional chemical bonding efficacy that is expected to contribute to their adhesive potential to tooth tissue.

1,035 citations

Journal ArticleDOI
TL;DR: It is concluded that resin bonded to enamel protected the resin-dentin bond against degradation, while direct exposure to water for 4 years affected bonds produced by two-step total-etch adhesives.
Abstract: Resin-dentin bonds degrade over time. The objective of this study was to evaluate the influence of variables like hybridization effectiveness and diffusion/elution of interface components on degradation. Hypotheses tested were: (1) There is no difference in degradation over time between two- and three-step total-etch adhesives; and (2) a composite-enamel bond protects the adjacent composite-dentin bond against degradation. The micro-tensile bond strength (microTBS) to dentin of 2 three-step total-etch adhesives was compared with that of 2 two-step total-etch adhesives after 4 years of storage in water. Quantitative and qualitative failure analyses were conducted correlating Fe-SEM and TEM. Indirect exposure to water did not significantly reduce the microTBS of any adhesive, while direct exposure resulted in a significantly reduced microTBS of both two-step adhesives. It is concluded that resin bonded to enamel protected the resin-dentin bond against degradation, while direct exposure to water for 4 years affected bonds produced by two-step total-etch adhesives.

611 citations


Cited by
More filters
Journal ArticleDOI
TL;DR: New fabrication techniques, such as solid-free form fabrication, can potentially be used to generate scaffolds with morphological and mechanical properties more selectively designed to meet the specificity of bone-repair needs.

5,470 citations

Journal ArticleDOI
TL;DR: A review of the properties, biological performance, challenges and future directions of magnesium-based biomaterials can be found in this paper, where the authors explore the properties and challenges of magnesium biomaterial.

3,757 citations

Journal ArticleDOI
TL;DR: A review of surface modification techniques for titanium and titanium alloys can be found in this article, where the authors have shown that the wear resistance, corrosion resistance, and biological properties can be improved selectively using the appropriate surface treatment techniques while the desirable bulk attributes of the materials are retained.
Abstract: Titanium and titanium alloys are widely used in biomedical devices and components, especially as hard tissue replacements as well as in cardiac and cardiovascular applications, because of their desirable properties, such as relatively low modulus, good fatigue strength, formability, machinability, corrosion resistance, and biocompatibility. However, titanium and its alloys cannot meet all of the clinical requirements. Therefore, in order to improve the biological, chemical, and mechanical properties, surface modification is often performed. This article reviews the various surface modification technologies pertaining to titanium and titanium alloys including mechanical treatment, thermal spraying, sol–gel, chemical and electrochemical treatment, and ion implantation from the perspective of biomedical engineering. Recent work has shown that the wear resistance, corrosion resistance, and biological properties of titanium and titanium alloys can be improved selectively using the appropriate surface treatment techniques while the desirable bulk attributes of the materials are retained. The proper surface treatment expands the use of titanium and titanium alloys in the biomedical fields. Some of the recent applications are also discussed in this paper.

3,019 citations

Journal ArticleDOI
TL;DR: This review comprehensively covers literature reports which have investigated specifically the effect of dissolution products of silicate bioactive glasses and glass-ceramics in relation to osteogenesis and angiogenesis and focuses on the ion release kinetics of the materials and the specific effect of the released ionic dissolution products on human cell behaviour.

2,056 citations

Journal ArticleDOI
TL;DR: This paper critically appraises methodologies that focus on chemical degradation patterns of hydrolysis and elution of interface components, as well as mechanically oriented test set-ups, such as fatigue and fracture toughness measurements, to assess adhesion durability.
Abstract: The immediate bonding effectiveness of contemporary adhesives is quite favorable, regardless of the approach used. In the long term, the bonding effectiveness of some adhesives drops dramatically, whereas the bond strengths of other adhesives are more stable. This review examines the fundamental processes that cause the adhesion of biomaterials to enamel and dentin to degrade with time. Non-carious class V clinical trials remain the ultimate test method for the assessment of bonding effectiveness, but in addition to being high-cost, they are time- and labor-consuming, and they provide little information on the true cause of clinical failure. Therefore, several laboratory protocols were developed to predict bond durability. This paper critically appraises methodologies that focus on chemical degradation patterns of hydrolysis and elution of interface components, as well as mechanically oriented test set-ups, such as fatigue and fracture toughness measurements. A correlation of in vitro and in vivo data revealed that, currently, the most validated method to assess adhesion durability involves aging of micro-specimens of biomaterials bonded to either enamel or dentin. After about 3 months, all classes of adhesives exhibited mechanical and morphological evidence of degradation that resembles in vivo aging effects. A comparison of contemporary adhesives revealed that the three-step etch-and-rinse adhesives remain the 'gold standard' in terms of durability. Any kind of simplification in the clinical application procedure results in loss of bonding effectiveness. Only the two-step self-etch adhesives approach the gold standard and do have some additional clinical benefits.

1,778 citations