scispace - formally typeset
Search or ask a question
Author

Yu. F. Malkov

Bio: Yu. F. Malkov is an academic researcher from Johns Hopkins University. The author has contributed to research in topics: Active galactic nucleus & Galaxy. The author has an hindex of 7, co-authored 11 publications receiving 796 citations.

Papers
More filters
Journal ArticleDOI
TL;DR: In this paper, the authors present the final installment of an intensive 13-year study of variations of the optical continuum and broad H beta emission line in the Seyfert 1 galaxy NGC 5548.
Abstract: We present the final installment of an intensive 13 year study of variations of the optical continuum and broad H beta emission line in the Seyfert 1 galaxy NGC 5548. The database consists of 1530 optical continuum measurements and 1248 H beta measurements. The H beta variations follow the continuum variations closely, with a typical time delay of about 20 days. However, a year-by-year analysis shows that the magnitude of emission-line time delay is correlated with the mean continuum flux. We argue that the data are consistent with the simple model prediction between the size of the broad-line region and the ionizing luminosity, r is proportional to L(sup 1/2)(sub ion). Moreover, the apparently linear nature of the correlation between the H beta response time and the nonstellar optical continuum F(sub opt) arises as a consequence of the changing shape of the continuum as it varies, specifically F(sub opt) is proportional to F(sup 0.56)(sub UV).

218 citations

Journal ArticleDOI
TL;DR: In this paper, the authors present results of an intensive 2 month campaign of ground-based spectrophotometric monitoring of the Seyfert 1 galaxy NGC 7469, with a temporal resolution 1 day.
Abstract: We present results of an intensive 2 month campaign of ground-based spectrophotometric monitoring of the Seyfert 1 galaxy NGC 7469, with a temporal resolution 1 day. The broad Hα and Hβ emission lines respond to ~35% ultraviolet continuum variations with an amplitude of ~10% and time delays of 5.6 ± 1.3 days and 5.4 ± 0.8 days, respectively. We interpret this as evidence of variable Balmer line gas ~5-6 light days from the central source in this object, widely believed to be a supermassive black hole. The virial mass of the central source implied by line widths and time delays is ~106-107 M☉. Concomitantly, we find evidence for wavelength-dependent continuum time delays: optical continuum variations lag those at 1315 A by 1.0 ± 0.3 days at 4865 A to 1.5 ± 0.7 days at 6962 A. This suggests a stratified continuum reprocessing region extending several light days from the central source, possibly an accretion disk.

216 citations

Journal ArticleDOI
TL;DR: The results of a ground-based optical monitoring campaign on 3C 390.3 in 1994-1995 are presented in this article, where the optical emission lines Hα, Hβ, Hγ, and He I λ5876 respond to the high-energy continuum variations with time delays typically about 20 days, with uncertainties of about 8 days.
Abstract: Results of a ground-based optical monitoring campaign on 3C 390.3 in 1994-1995 are presented. The broadband fluxes (B, V, R, and I), the spectrophotometric optical continuum flux Fλ(5177 A), and the integrated emission-line fluxes of Hα, Hβ, Hγ, He I λ5876, and He II λ4686 all show a nearly monotonic increase with episodes of milder short-term variations superposed. The amplitude of the continuum variations increases with decreasing wavelength (4400-9000 A). The optical continuum variations follow the variations in the ultraviolet and X-ray with time delays, measured from the centroids of the cross-correlation functions, typically around 5 days, but with uncertainties also typically around 5 days; zero time delay between the high-energy and low-energy continuum variations cannot be ruled out. The strong optical emission lines Hα, Hβ, Hγ, and He I λ5876 respond to the high-energy continuum variations with time delays typically about 20 days, with uncertainties of about 8 days. There is some evidence that He II λ4686 responds somewhat more rapidly, with a time delay of around 10 days, but again, the uncertainties are quite large (~8 days). The mean and rms spectra of the Hα and Hβ line profiles provide indications for the existence of at least three distinct components located at ±4000 and 0 km s-1 relative to the line peak. The emission-line profile variations are largest near line center.

123 citations

Journal ArticleDOI
TL;DR: In this paper, the results of 3 yr of ground-based observations of the Seyfert 1 galaxy NGC 5548 were combined with previously reported data, yielding optical continuum and broad-line Hβ light curves for a total of 8 yr.
Abstract: We present the results of 3 yr of ground-based observations of the Seyfert 1 galaxy NGC 5548, which, combined with previously reported data, yield optical continuum and broad-line Hβ light curves for a total of 8 yr. The light curves consist of over 800 points, with a typical spacing of a few days between observations. During this 8 yr period, the nuclear continuum has varied by more than a factor of 7, and the Hβ emission line has varied by a factor of nearly 6. The Hβ emission line responds to continuum variations with a time delay or lag of ~10-20 days, the precise value varying somewhat from year to year. We find some indications that the lag varies with continuum flux in the sense that the lag is larger when the source is brighter.

94 citations

Journal ArticleDOI
10 Oct 1996
TL;DR: In this paper, the results of an intensive ultraviolet monitoring campaign on the Seyfert 1 galaxy NGC 4151, as part of an effort to study its short-timescale variability over a broad range in wavelength.
Abstract: Presents the results of an intensive ultraviolet monitoring campaign on the Seyfert 1 galaxy NGC 4151, as part of an effort to study its short-timescale variability over a broad range in wavelength. The nucleus of NGC 4151 was observed continuously with the International Ultraviolet Explorer for 9.3 days, yielding a pair of LWP and SWP spectra every ~70 minutes, and during 4 hr periods for 4 days prior to and 5 days after the continuous-monitoring period. The sampling frequency of the observations is an order of magnitude higher than that of any previous UV monitoring campaign on a Seyfert galaxy. The continuum fluxes in bands from 1275 to 2688 Aring went through four significant and well-defined ldquoeventsrdquo of duration 2-3 days during the continuous-monitoring period. The authors find that the amplitudes of the continuum variations decrease with increasing wavelength, which extends a general trend for this and other Seyfert galaxies to smaller timescales (i.e., a few days). The continuum variations in all the UV bands are simultaneous to within an accuracy of ~0.15 days, providing a strict constraint on continuum models. The emission-line light curves show only one major event during the continuous monitoring (a slow rise followed by a shallow dip) and do not correlate well with continuum light curves over the short duration of the campaign, because the timescale for continuum variations is apparently smaller than the response times of the emission lines

76 citations


Cited by
More filters
Journal ArticleDOI
TL;DR: In this article, the authors used spectro- photometrically monitored Palomar-Green quasars in order to obtain mea- surements of their emission lines and investigate the relationship between quasar luminosity, central black hole mass, and broad emission-line regions (BLRs) size in AGNs.
Abstract: Correlated variations in the line and continuum emission from active galactic nuclei (AGNs) can be used to determine the size and geometry of the broad emission-line regions (BLRs). We have spectro- photometrically monitored a well-de—ned sample of 28 Palomar-Green quasars in order to obtain mea- surements of their BLRs and to investigate the relationships between quasar luminosity, central black hole mass, and BLR size in AGNs. Spectrophotometry was obtained every 1¨4 months for 7.5 yr, yield- ing 20¨70 observing epochs per object. Both the continuum and emission-line —uxes of all of the quasars were observed to change during the duration of the observing program. Seventeen of the 28 objects were observed with adequate sampling independent observing epochs) to search for correlated variations (Z20 between the Balmer emission lines and the continuum —ux. For each of these 17 objects, a signi—cant correlation was observed, with the Balmer-line variations lagging those of the continuum by D100 days (rest frame). Our work increases the available luminosity range for studying the size-mass-luminosity relations in AGNs by 2 orders of magnitude and doubles the number of objects suitable for such studies. Combining our results with comparable published data available for Seyfert 1 galaxies, we —nd the BLR size scales with the rest-frame 5100 luminosity as L0.70B0.03. This determination of the scaling of the Ae size of the BLR as a function of luminosity is signi—cantly diUerent from those previously published and suggests that the eUective ionization parameter in AGNs may be a decreasing function of luminosity. We are also able to constrain, subject to our assumption that gravity dominates the motions of the BLR gas, the scaling relationship between the mass of the central black holes and the luminosity in AGNs. We —nd that the central mass scales with 5100 luminosity as M P L0.5B0.1. This is inconsistent with all Ae AGNs having optical luminosity that is a constant fraction of the Eddington luminosity. Subject headings: galaxies: activequasars: emission linesquasars: general

2,119 citations

Journal ArticleDOI
TL;DR: In this article, a reanalysis of broad emission-line reverberation-mapping data was carried out for 35 active galactic nuclei (AGNs) based on a complete and consistent reanalysis, and it was shown that the highest precision measure of the virial product cτΔV2/G is obtained by using the cross-correlation function centroid (cf.
Abstract: We present improved black hole masses for 35 active galactic nuclei (AGNs) based on a complete and consistent reanalysis of broad emission-line reverberation-mapping data From objects with multiple line measurements, we find that the highest precision measure of the virial product cτΔV2/G, where τ is the emission-line lag relative to continuum variations and ΔV is the emission-line width, is obtained by using the cross-correlation function centroid (as opposed to the cross-correlation function peak) for the time delay and the line dispersion (as opposed to FWHM) for the line width and by measuring the line width in the variable part of the spectrum Accurate line-width measurement depends critically on avoiding contaminating features, in particular the narrow components of the emission lines We find that the precision (or random component of the error) of reverberation-based black hole mass measurements is typically around 30%, comparable to the precision attained in measurement of black hole masses in quiescent galaxies by gas or stellar dynamical methods Based on results presented in a companion paper by Onken et al, we provide a zero-point calibration for the reverberation-based black hole mass scale by using the relationship between black hole mass and host-galaxy bulge velocity dispersion The scatter around this relationship implies that the typical systematic uncertainties in reverberation-based black hole masses are smaller than a factor of 3 We present a preliminary version of a mass-luminosity relationship that is much better defined than any previous attempt Scatter about the mass-luminosity relationship for these AGNs appears to be real and could be correlated with either Eddington ratio or object inclination

1,893 citations

Journal ArticleDOI
TL;DR: In this article, the authors reported that NGC 2617 went through a dramatic outburst, during which its X-ray flux increased by over an order of magnitude followed by an increase of its optical/ultraviolet (UV) continuum flux.
Abstract: After the All-Sky Automated Survey for SuperNovae discovered a significant brightening of the inner region of NGC 2617, we began a ∼70 day photometric and spectroscopic monitoring campaign from the X-ray through near-infrared (NIR) wavelengths. We report that NGC 2617 went through a dramatic outburst, during which its X-ray flux increased by over an order of magnitude followed by an increase of its optical/ultraviolet (UV) continuum flux by almost an order of magnitude. NGC 2617, classified as a Seyfert 1.8 galaxy in 2003, is now a Seyfert 1 due to the appearance of broad optical emission lines and a continuum blue bump. Such 'changing look active galactic nuclei (AGNs)' are rare and provide us with important insights about AGN physics. Based on the Hβ line width and the radius-luminosity relation, we estimate the mass of central black hole (BH) to be (4 ± 1) × 10{sup 7} M {sub ☉}. When we cross-correlate the light curves, we find that the disk emission lags the X-rays, with the lag becoming longer as we move from the UV (2-3 days) to the NIR (6-9 days). Also, the NIR is more heavily temporally smoothed than the UV. This can largely be explained bymore » a simple model of a thermally emitting thin disk around a BH of the estimated mass that is illuminated by the observed, variable X-ray fluxes.« less

1,473 citations

Journal ArticleDOI
TL;DR: In this article, the mass scaling relationship between line widths and luminosity is used for estimating the central black hole mass in nearby AGNs and distant luminous quasars alike using either optical or UV single-epoch spectroscopy.
Abstract: We present four improved empirical relationships useful for estimating the central black hole mass in nearby AGNs and distant luminous quasars alike using either optical or UV single-epoch spectroscopy. These mass scaling relationships between line widths and luminosity are based on recently improved empirical relationships between the broad-line region size and luminosities in various energy bands and are calibrated to the improved mass measurements of nearby AGNs based on emission-line reverberation mapping. The mass scaling relationship based on the Hβ line luminosity allows mass estimates for low-redshift sources with strong contamination of the optical continuum luminosity by stellar or nonthermal emission, while that based on the C IV λ1549 line dispersion allows mass estimates in cases where only the line dispersion (as opposed to the FWHM) can be reliably determined. We estimate that the absolute uncertainties in masses given by these mass scaling relationships are typically around a factor of 4. We include in an appendix mass estimates for all of the Bright Quasar Survey (PG) quasars for which direct reverberation-based mass measurements are not available.

1,289 citations

Journal ArticleDOI
TL;DR: In this article, the authors reported that NGC 2617 went through a dramatic outburst, during which its X-ray flux increased by over an order of magnitude followed by an increase of its optical/ultraviolet (UV) continuum flux.
Abstract: After the All-Sky Automated Survey for SuperNovae (ASAS-SN) discovered a significant brightening of the inner region of NGC 2617, we began a ~70 day photometric and spectroscopic monitoring campaign from the X-ray through near-infrared (NIR) wavelengths. We report that NGC 2617 went through a dramatic outburst, during which its X-ray flux increased by over an order of magnitude followed by an increase of its optical/ultraviolet (UV) continuum flux by almost an order of magnitude. NGC 2617, classified as a Seyfert 1.8 galaxy in 2003, is now a Seyfert 1 due to the appearance of broad optical emission lines and a continuum blue bump. Such "changing look Active Galactic Nuclei (AGN)" are rare and provide us with important insights about AGN physics. Based on the Hbeta line width and the radius-luminosity relation, we estimate the mass of central black hole to be (4 +/- 1) x 10^7 M_sun. When we cross-correlate the light curves, we find that the disk emission lags the X-rays, with the lag becoming longer as we move from the UV (2-3 days) to the NIR (6-9 days). Also, the NIR is more heavily temporally smoothed than the UV. This can largely be explained by a simple model of a thermally emitting thin disk around a black hole of the estimated mass that is illuminated by the observed, variable X-ray fluxes.

1,191 citations