Institution
Applied Biosystems
About: Applied Biosystems is a based out in . It is known for research contribution in the topics: Mass spectrometry & Capillary electrophoresis. The organization has 1521 authors who have published 1579 publications receiving 285423 citations.
Topics: Mass spectrometry, Capillary electrophoresis, Nucleic acid, Oligonucleotide, Tandem mass spectrometry
Papers published on a yearly basis
Papers
More filters
••
TL;DR: This work demonstrates the ligation dependent amplification of a 40 base pair region of plasmid bearing IS6110, which has been reported to be specific for M. tuberculosis complex as target DNA and serves as a basis for further studies in the development of a rapid clinical diagnostic test for tuberculosis.
52 citations
•
21 Jul 2000TL;DR: In this article, a luminescence detecting apparatus comprising a chamber containing a collimator (110), a Fresnel field lens (120), a filter (130), and a camera lens (140), whereupon a focused image is created by the optics onto a charge-coupled device camera (70).
Abstract: A luminescence detecting apparatus comprising a chamber (60) containing a collimator (110), a Fresnel field lens (120), a filter (130), and a camera lens (140), whereupon a focused image is created by the optics onto a charge-coupled device camera (70).
52 citations
••
TL;DR: Sensitivity was three times better for dideoxynucleosides analyzed by infusion and 12 times higher for antidepressant drugs analyzed by CE/MS with this interface compared with ionspray, and the main improvement in sensitivity is the gain in sensitivity.
Abstract: We have developed a novel sheath-flow interface for low-flow electrospray ionization mass spectrometry (ESI-MS) and capillary electrophoresis/electrospray mass spectrometry (CE/ESI-MS). The interface is composed of two capillaries. One is a tapered fused-silica ESI emitter suitable for microliter and nanoliter flow rate electrospray and the other is a tail-end gold-coated CE separation column that is inserted into the emitter. A sheath liquid is supplied between the column and the emitter capillaries. The gold coating and the sheath liquid are used as the conducting media for ESI and the CE circuit. This novel design was initially evaluated by an infusion ESI-MS analysis of the most common antiretroviral dideoxynucleosides, followed by CE/MS coupling analysis of several antidepressant drugs. With infusion studies, the effects of the sheath liquid and the sample flow rates on detection sensitivity and signal stability were investigated. For an emitter with an internal diameter of 30 microm, the optimum flow rates for the sheath and the sample were 200 and 300 nL/min, respectively. The main improvement of this approach in comparison with conventional sheath liquid approaches using an ionspray interface is the gain in sensitivity. Sensitivities were three times better for dideoxynucleosides analyzed by infusion and 12 times higher for antidepressant drugs analyzed by CE/MS with this interface compared with ionspray. The emitter is durable, disposable, and simple to fabricate.
52 citations
••
TL;DR: Little impact is observed on the TP and FP rates in detection of differentially expressed genes and this indicates a certain robustness of the analysis methods currently in use in the field, particularly when used in conjunction with the Applied Biosystems Gene Expression System.
Abstract: DNA microarray technology provides a powerful tool for characterizing gene expression on a genome scale. While the technology has been widely used in discovery-based medical and basic biological research, its direct application in clinical practice and regulatory decision-making has been questioned. A few key issues, including the reproducibility, reliability, compatibility and standardization of microarray analysis and results, must be critically addressed before any routine usage of microarrays in clinical laboratory and regulated areas can occur. In this study we investigate some of these issues for the Applied Biosystems Human Genome Survey Microarrays. We analyzed the gene expression profiles of two samples: brain and universal human reference (UHR), a mixture of RNAs from 10 cancer cell lines, using the Applied Biosystems Human Genome Survey Microarrays. Five technical replicates in three different sites were performed on the same total RNA samples according to manufacturer's standard protocols. Five different methods, quantile, median, scale, VSN and cyclic loess were used to normalize AB microarray data within each site. 1,000 genes spanning a wide dynamic range in gene expression levels were selected for real-time PCR validation. Using the TaqMan® assays data set as the reference set, the performance of the five normalization methods was evaluated focusing on the following criteria: (1) Sensitivity and reproducibility in detection of expression; (2) Fold change correlation with real-time PCR data; (3) Sensitivity and specificity in detection of differential expression; (4) Reproducibility of differentially expressed gene lists. Our results showed a high level of concordance between these normalization methods. This is true, regardless of whether signal, detection, variation, fold change measurements and reproducibility were interrogated. Furthermore, we used TaqMan® assays as a reference, to generate TPR and FDR plots for the various normalization methods across the assay range. Little impact is observed on the TP and FP rates in detection of differentially expressed genes. Additionally, little effect was observed by the various normalization methods on the statistical approaches analyzed which indicates a certain robustness of the analysis methods currently in use in the field, particularly when used in conjunction with the Applied Biosystems Gene Expression System.
52 citations
Authors
Showing all 1521 results
Name | H-index | Papers | Citations |
---|---|---|---|
Richard A. Gibbs | 172 | 889 | 249708 |
Friedrich C. Luft | 113 | 1095 | 47619 |
Alexander N. Glazer | 71 | 208 | 21068 |
Vineet Bafna | 68 | 236 | 42574 |
Kevin R. Coombes | 63 | 308 | 23592 |
Darryl J. Pappin | 61 | 170 | 29409 |
Mark D. Johnson | 60 | 289 | 16103 |
György Marko-Varga | 56 | 409 | 12600 |
Paul Thomas | 56 | 128 | 44810 |
Gerald Zon | 55 | 256 | 11126 |
Michael W. Hunkapiller | 51 | 130 | 29756 |
Bjarni V. Halldorsson | 51 | 145 | 13180 |
David H. Hawke | 50 | 157 | 9824 |
Ellson Y. Chen | 50 | 71 | 28836 |
Sridhar Hannenhalli | 49 | 162 | 21959 |