scispace - formally typeset
Search or ask a question
Institution

Hydro-Québec

GovernmentMontreal, Quebec, Canada
About: Hydro-Québec is a government organization based out in Montreal, Quebec, Canada. It is known for research contribution in the topics: Electric power system & Dielectric. The organization has 2596 authors who have published 4433 publications receiving 100878 citations.


Papers
More filters
Journal ArticleDOI
TL;DR: In this paper, it was shown that strontium-substituted lanthanum cobaltite, La 1 − xSr xCoO 3 − δ, has much less tolerance for any variation in the A/B ratio than its manganite counterpart.

46 citations

Journal ArticleDOI
TL;DR: In this paper, a transient three-dimensional model of a porous regenerator operating at room temperature is presented, where the solid magnetic material and the regeneration fluid are modeled separately, and the fluid flows through interstitial channels formed by a regular matrix of solid particles.

46 citations

Journal ArticleDOI
S. Bernard1, G. Trudel1, G. Scott1
TL;DR: In this article, the authors proposed a defensive scheme for Hydro-Quebec's transmission system based entirely on automatic action, which mainly relies on a 735 kV shunt reactor switching system (called MAIS), a generation rejection and/or remote load shedding scheme (called RPTC), and an underfrequency load shedding system.
Abstract: Hydro-Quebec has undertaken a major program to upgrade the reliability of its transmission system. Much effort has been directed toward increasing the system's capacity to withstand extreme contingencies, usually caused by multiple incidents or the successive tripping of transmission lines. In order to counter such events, Hydro-Quebec has adopted a defensive scheme. Based entirely on automatic action, this scheme will mainly rely on: a 735 kV shunt reactor switching system (called MAIS); a generation rejection and/or remote load-shedding system (called RPTC); and an underfrequency load-shedding system. The MAIS system, which is the subject of this paper, will be implemented in 22 substations and is required to control voltage on the system after a severe event. Each MAIS system, acting locally, is entirely independent and will close or trip shunt reactors in response to local conditions.

46 citations

Journal ArticleDOI
D.W.A. Willen1, J.R. Cave1
TL;DR: In this paper, the performance of inductive fault current limiters based on Bi-2212 high temperature superconducting tubes has been evaluated and the fault current limitation is due to the nonlinear impedance of this device.
Abstract: The current limiting performance of inductive fault current limiters based on Bi-2212 high temperature superconducting tubes has been evaluated. Fault current limitation is due to the nonlinear impedance of this device when the induced current in the superconducting Bi-2212 tubes exceeds the critical current. A power load in a test circuit is first operated in nominal power conditions ( >

45 citations

Journal ArticleDOI
TL;DR: In this article, a model for hourly load (hourly*energy consumption) forecasting is developed based on using the linear estimation theory to obtain four different prediction models for the load at a particular hour corresponding to the four correlation periods, namely an hour*, a day, a week and a year.
Abstract: A model for hourly load (hourly*energy consumption) forecasting is developed. The method is based on using the linear estimation theory to obtain four different prediction models for the load at a particular hour corresponding to the four correlation periods, namely an hour*, a day, a week and a year. The four predicted values with their respective variances are combined optimally to obtain a composite forecast for the hour. The holiday forecasts are improved by selectively rejecting one or more of these four predicted values. Actual data from the Hydro-Quebec system load file for the period of September 28, 1969 to September 26, 1971, is used as data for identification of the model. The load forecasts for the period of September 27, 1971 to September 26, 1972 are compared with the loads actually realized during the same period.

45 citations


Authors

Showing all 2603 results

NameH-indexPapersCitations
John B. Goodenough1511064113741
Mark Sutton128100978703
Pierre Legendre9836682995
Jackie Y. Ying8958735694
Karim Zaghib6953316785
Geza Joos6751415880
M. V. Reddy6625415772
Kamal Al-Haddad6182821017
Jean-Pol Dodelet5916418473
Taha B. M. J. Ouarda5834912230
Michael R. Wertheimer5432011003
Richard Martin5433911465
Michel Armand5415244873
Marc Lucotte501698088
Abdelbast Guerfi492156739
Network Information
Related Institutions (5)
Westinghouse Electric
38K papers, 523.3K citations

82% related

École Polytechnique de Montréal
18.3K papers, 494.3K citations

82% related

General Electric
110.5K papers, 1.8M citations

80% related

United States Department of Energy
14.1K papers, 556.9K citations

79% related

Polytechnic University of Milan
58.4K papers, 1.2M citations

79% related

Performance
Metrics
No. of papers from the Institution in previous years
YearPapers
20231
202256
2021115
2020173
2019162
2018156