scispace - formally typeset
Search or ask a question

Showing papers by "National Physical Laboratory published in 2015"


Journal ArticleDOI
TL;DR: A large variety of data comprised of the mechanical properties of nanomaterial toughened composites reported to date has been compiled to facilitate the evolution of this emerging field, and the results are presented in maps showing the effect of nanoparticle loading on mode I fracture toughness, stiffness and strength.
Abstract: The incorporation of nanomaterials in the polymer matrix is considered to be a highly effective technique to improve the mechanical properties of resins. In this paper the effects of the addition of different nanoparticles such as single-walled CNT (SWCNT), double-walled CNT (DWCNT), multi-walled CNT (MWCNT), graphene, nanoclay and nanosilica on fracture toughness, strength and stiffness of the epoxy matrix have been reviewed. The Young's modulus (E), ultimate tensile strength (UTS), mode I (GIC) and mode II (GIIC) fracture toughness of the various nanocomposites at different nanoparticle loadings are compared. The review shows that, depending on the type of nanoparticles, the integration of the nanoparticles has a substantial effect on mode I and mode II fracture toughness, strength and stiffness. The critical factors such as maintaining a homogeneous dispersion and good adhesion between the matrix and the nanoparticles are highlighted. The effect of surface functionalization, its relevancy and toughening mechanism are also scrutinized and discussed. A large variety of data comprised of the mechanical properties of nanomaterial toughened composites reported to date has thus been compiled to facilitate the evolution of this emerging field, and the results are presented in maps showing the effect of nanoparticle loading on mode I fracture toughness, stiffness and strength.

567 citations


Journal ArticleDOI
TL;DR: In this paper, the effect of defects induced by ion bombardment on the Raman spectrum of single-layer molybdenum disulfide was determined by using density functional theory to calculate the phonon dispersion curves.
Abstract: We determine the effect of defects induced by ion bombardment on the Raman spectrum of single-layer molybdenum disulfide. The evolution of both the linewidths and frequency shifts of the first-order Raman bands with the density of defects is explained with a phonon confinement model, using density functional theory to calculate the phonon dispersion curves. We identify several defect-induced Raman scattering peaks arising from zone-edge phonon modes. Among these, the most prominent is the $\mathrm{LA}(M)$ peak at $\ensuremath{\sim}227\phantom{\rule{0.16em}{0ex}}\mathrm{c}{\mathrm{m}}^{\ensuremath{-}1}$ and its intensity, relative to the one of first-order Raman bands, is found to be proportional to the density of defects. These results provide a practical route to quantify defects in single-layer $\mathrm{Mo}{\mathrm{S}}_{2}$ using Raman spectroscopy and highlight an analogy between the $\mathrm{LA}(M)$ peak in $\mathrm{Mo}{\mathrm{S}}_{2}$ and the $D$ peak in graphene.

537 citations


Journal ArticleDOI
TL;DR: High-speed synchrotron X-ray computed tomography and radiography is used, in conjunction with thermal imaging, to track the evolution of internal structural damage and thermal behaviour during initiation and propagation of thermal runaway in lithium-ion batteries, yielding insights into key degradation modes.
Abstract: Prevention and mitigation of thermal runaway presents one of the greatest challenges for the safe operation of lithium-ion batteries. Here, we demonstrate for the first time the application of high-speed synchrotron X-ray computed tomography and radiography, in conjunction with thermal imaging, to track the evolution of internal structural damage and thermal behaviour during initiation and propagation of thermal runaway in lithium-ion batteries. This diagnostic approach is applied to commercial lithium-ion batteries (LG 18650 NMC cells), yielding insights into key degradation modes including gas-induced delamination, electrode layer collapse and propagation of structural degradation. It is envisaged that the use of these techniques will lead to major improvements in the design of Li-ion batteries and their safety features.

484 citations


Journal ArticleDOI
TL;DR: In this paper, 3D printed air-filled metal-pipe rectangular waveguides (MPRWGs) and 3D printing for microwave and millimeter-wave applications are investigated in detail.
Abstract: This paper first reviews manufacturing technologies for realizing air-filled metal-pipe rectangular waveguides (MPRWGs) and 3-D printing for microwave and millimeter-wave applications. Then, 3-D printed MPRWGs are investigated in detail. Two very different 3-D printing technologies have been considered: low-cost lower-resolution fused deposition modeling for microwave applications and higher-cost high-resolution stereolithography for millimeter-wave applications. Measurements against traceable standards in MPRWGs were performed by the U.K.’s National Physical Laboratory. It was found that the performance of the 3-D printed MPRWGs were comparable with those of standard waveguides. For example, across X-band (8–12 GHz), the dissipative attenuation ranges between 0.2 and 0.6 dB/m, with a worst case return loss of 32 dB; at W-band (75–110 GHz), the dissipative attenuation was 11 dB/m at the band edges, with a worst case return loss of 19 dB. Finally, a high-performance W-band sixth-order inductive iris bandpass filter, having a center frequency of 107.2 GHz and a 6.8-GHz bandwidth, was demonstrated. The measured insertion loss of the complete structure (filter, feed sections, and flanges) was only 0.95 dB at center frequency, giving an unloaded quality factor of 152—clearly demonstrating the potential of this low-cost manufacturing technology, offering the advantages of lightweight rapid prototyping/manufacturing and relatively very low cost when compared with traditional (micro)machining.

263 citations


Journal ArticleDOI
TL;DR: The surfaces engineered in this study are titania (TiO2) nanowire arrays that are selectively bactericidal against motile bacteria, while capable of guiding mammalian cell proliferation according to the type of the array.
Abstract: Biocompatible surfaces hold key to a variety of biomedical problems that are directly related to the competition between host-tissue cell integration and bacterial colonisation. A saving solution to this is seen in the ability of cells to uniquely respond to physical cues on such surfaces thus prompting the search for cell-instructive nanoscale patterns. Here we introduce a generic rationale engineered into biocompatible, titanium, substrates to differentiate cell responses. The rationale is inspired by cicada wing surfaces that display bactericidal nanopillar patterns. The surfaces engineered in this study are titania (TiO2) nanowire arrays that are selectively bactericidal against motile bacteria, while capable of guiding mammalian cell proliferation according to the type of the array. The concept holds promise for clinically relevant materials capable of differential physico-mechanical responses to cellular adhesion.

198 citations


Journal ArticleDOI
05 May 2015
TL;DR: In this paper, a preliminary investigation was carried out on two additive manufacturing processes (selective laser melting (SLM) and electron beam melting (EBM) focusing on the effect of build angle and post processing.
Abstract: The surface texture of additively manufactured metallic surfaces made by powder bed methods is affected by a number of factors, including the powder's particle size distribution, the effect of the heat source, the thickness of the printed layers, the angle of the surface relative to the horizontal build bed and the effect of any post processing/finishing. The aim of the research reported here is to understand the way these surfaces should be measured in order to characterise them. In published research to date, the surface texture is generally reported as an Ra value, measured across the lay. The appropriateness of this method for such surfaces is investigated here. A preliminary investigation was carried out on two additive manufacturing processes—selective laser melting (SLM) and electron beam melting (EBM)—focusing on the effect of build angle and post processing. The surfaces were measured using both tactile and optical methods and a range of profile and areal parameters were reported. Test coupons were manufactured at four angles relative to the horizontal plane of the powder bed using both SLM and EBM. The effect of lay—caused by the layered nature of the manufacturing process—was investigated, as was the required sample area for optical measurements. The surfaces were also measured before and after grit blasting.

191 citations


Journal ArticleDOI
TL;DR: This work categorises peptide self-assembled materials in relation to their non-peptide counterparts in terms of modularity, responsiveness and functional diversity, which enables direct comparisons with more traditional material chemistries.
Abstract: Peptide self-assembly is an increasingly attractive tool for nanomaterials. Perfected in biology peptide self-assembling systems have impacted on nearly any conceivable nanomaterial type. However, with all the information available to us commercialisation of peptide materials remains in its infancy. In an attempt to better understand the reasons behind this shortcoming we categorise peptide self-assembled materials in relation to their non-peptide counterparts. A particular emphasis is placed on the versatility of peptide self-assembly in terms of modularity, responsiveness and functional diversity, which enables direct comparisons with more traditional material chemistries.

187 citations


Journal ArticleDOI
27 Oct 2015
TL;DR: The use of terrestrial laser scanning (TLS) for plot-scale measurement was first demonstrated over a decade ago, with the intimation that these instruments could replace manual measurement methods as mentioned in this paper.
Abstract: Plot-scale measurements have been the foundation for forest surveys and reporting for over 200 years. Through recent integration with airborne and satellite remote sensing, manual measurements of vegetation structure at the plot scale are now the basis for landscape, continental and international mapping of our forest resources. The use of terrestrial laser scanning (TLS) for plot-scale measurement was first demonstrated over a decade ago, with the intimation that these instruments could replace manual measurement methods. This has not yet been the case, despite the unparalleled structural information that TLS can capture. For TLS to reach its full potential, these instruments cannot be viewed as a logical progression of existing plot-based measurement. TLS must be viewed as a disruptive technology that requires a rethink of vegetation surveys and their application across a wide range of disciplines. We review the development of TLS as a plot-scale measurement tool, including the evolution of both instrument hardware and key data processing methodologies. We highlight two broad data modelling approaches of gap probability and geometrical modelling and the basic theory that underpins these. Finally, we discuss the future prospects for increasing the utilisation of TLS for plot-scale forest assessment and forest monitoring.

182 citations


Journal ArticleDOI
TL;DR: It is anticipated that universality may not extend to the elements Sn, Sb, I, and Cs, making the detection of these elements in metal-poor stars of the utmost importance to determine the exact conditions of individual r-process events.
Abstract: The $\ensuremath{\beta}$-decay half-lives of 110 neutron-rich isotopes of the elements from $_{37}\mathrm{Rb}$ to $_{50}\mathrm{Sn}$ were measured at the Radioactive Isotope Beam Factory. The 40 new half-lives follow robust systematics and highlight the persistence of shell effects. The new data have direct implications for $r$-process calculations and reinforce the notion that the second ($A\ensuremath{\approx}130$) and the rare-earth-element ($A\ensuremath{\approx}160$) abundance peaks may result from the freeze-out of an $(n,\ensuremath{\gamma})\ensuremath{\rightleftarrows}(\ensuremath{\gamma},n)$ equilibrium. In such an equilibrium, the new half-lives are important factors determining the abundance of rare-earth elements, and allow for a more reliable discussion of the $r$ process universality. It is anticipated that universality may not extend to the elements Sn, Sb, I, and Cs, making the detection of these elements in metal-poor stars of the utmost importance to determine the exact conditions of individual $r$-process events.

148 citations


Journal ArticleDOI
28 Jul 2015-ACS Nano
TL;DR: This article addresses the much debated question whether the degree of hydrophobicity of single- layer graphene (1LG) is different from that of double-layer graphene (2LG) by employing chemical force microscopy with a probe rendered hydrophobic by functionalization with octadecyltrichlorosilane (OTS).
Abstract: This article addresses the much debated question whether the degree of hydrophobicity of single-layer graphene (1LG) is different from that of double-layer graphene (2LG). Knowledge of the water affinity of graphene and its spatial variations is critically important as it can affect the graphene properties as well as the performance of graphene devices exposed to humidity. By employing chemical force microscopy with a probe rendered hydrophobic by functionalization with octadecyltrichlorosilane (OTS), the adhesion force between the probe and epitaxial graphene on SiC has been measured in deionized water. Owing to the hydrophobic attraction, a larger adhesion force was measured on 2LG Bernal-stacked domains of graphene surfaces, thus showing that 2LG is more hydrophobic than 1LG. Identification of 1LG and 2LG domains was achieved through Kelvin probe force microscopy and Raman spectral mapping. Approximate values of the adhesion force per OTS molecule have been calculated through contact area analysis. Fur...

126 citations


Journal ArticleDOI
TL;DR: The recommendations of this analysis may serve as a guide to researchers, companies, and regulators when selecting, developing, and evaluating the appropriateness of dispersion methods applied in mammalian and ecotoxicity testing.
Abstract: Selecting appropriate ways of bringing engineered nanoparticles (ENP) into aqueous dispersion is a main obstacle for testing, and thus for understanding and evaluating, their potential adverse effects to the environment and human health. Using different methods to prepare (stock) dispersions of the same ENP may be a source of variation in the toxicity measured. Harmonization and standardization of dispersion methods applied in mammalian and ecotoxicity testing are needed to ensure a comparable data quality and to minimize test artifacts produced by modifications of ENP during the dispersion preparation process. Such harmonization and standardization will also enhance comparability among tests, labs, and studies on different types of ENP. The scope of this review was to critically discuss the essential parameters in dispersion protocols for ENP. The parameters are identified from individual scientific studies and from consensus reached in larger scale research projects and international organizations. A step-wise approach is proposed to develop tailored dispersion protocols for ecotoxicological and mammalian toxicological testing of ENP. The recommendations of this analysis may serve as a guide to researchers, companies, and regulators when selecting, developing, and evaluating the appropriateness of dispersion methods applied in mammalian and ecotoxicity testing. However, additional experimentation is needed to further document the protocol parameters and investigate to what extent different stock dispersion methods affect ecotoxicological and mammalian toxicological responses of ENP.

Journal ArticleDOI
TL;DR: Three-dimensional secondary ion mass spectrometry (SIMS) imaging was used to investigate the cellular uptake of the antiarrhythmic agent amiodarone, a phospholipidosis-inducing pharmaceutical compound, and provided the basis for studying Cellular uptake of pharmaceutical compounds and their metabolites on the single cell level.
Abstract: Detecting metabolites and parent compound within a cell type is now a priority for pharmaceutical development. In this context, three-dimensional secondary ion mass spectrometry (SIMS) imaging was used to investigate the cellular uptake of the antiarrhythmic agent amiodarone, a phospholipidosis-inducing pharmaceutical compound. The high lateral resolution and 3D imaging capabilities of SIMS combined with the multiplex capabilities of ToF mass spectrometric detection allows for the visualization of pharmaceutical compound and metabolites in single cells. The intact, unlabeled drug compound was successfully detected at therapeutic dosages in macrophages (cell line: NR8383). Chemical information from endogenous biomolecules was used to correlate drug distributions with morphological features. From this spatial analysis, amiodarone was detected throughout the cell, with the majority of the compound found in the membrane and subsurface regions and absent in the nuclear regions. Similar results were obtained when the macrophages were doped with amiodarone metabolite, desethylamiodarone. The fwhm lateral resolution measured across an intracellular interface in high lateral resolution ion images was approximately 550 nm. Overall, this approach provides the basis for studying cellular uptake of pharmaceutical compounds and their metabolites on the single cell level.

Journal ArticleDOI
TL;DR: The hybrid improper ferroelectric mechanism recently proposed by Benedek and Fennie for these Ruddlesden-Popper compounds is confirmed and a systematic strategy for designing and searching for ceramics with large NTE coefficients is suggested.
Abstract: We present new results on the microscopic nature of the ferroelectricity mechanisms in ${\mathrm{Ca}}_{3}{\mathrm{Mn}}_{2}{\mathrm{O}}_{7}$ and ${\mathrm{Ca}}_{3}{\mathrm{Ti}}_{2}{\mathrm{O}}_{7}$. To the first approximation, we confirm the hybrid improper ferroelectric mechanism recently proposed by Benedek and Fennie for these Ruddlesden-Popper compounds. However, in ${\mathrm{Ca}}_{3}{\mathrm{Mn}}_{2}{\mathrm{O}}_{7}$ we find that there is a complex competition between lattice modes of different symmetry which leads to a phase coexistence over a large temperature range and the ``symmetry trapping'' of a soft mode. This trapping of the soft mode leads to a large uniaxial negative thermal expansion (NTE) reaching a maximum between 250 and 350 K ($3.6\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}6}\text{ }\text{ }{\mathrm{K}}^{\ensuremath{-}1}$) representing the only sizable NTE reported for these and related perovskite materials to date. Our results suggest a systematic strategy for designing and searching for ceramics with large NTE coefficients.

Journal ArticleDOI
TL;DR: A detailed overview of the state of the art in tip-enhanced Raman spectroscopy (TERS) and its applications at the horizon including those in materials science, chemical science and biological science is provided in this paper.
Abstract: This review provides a detailed overview of the state of the art in tip-enhanced Raman spectroscopy (TERS) and focuses on its applications at the horizon including those in materials science, chemical science and biological science. The capabilities and potential of TERS are demonstrated by summarising major achievements of TERS applications in disparate fields of scientific research. Finally, an outlook has been given on future development of the technique and the mechanisms of achieving high signal enhancement and spatial resolution.

Journal ArticleDOI
TL;DR: In this paper, the authors discuss the issues in relation to hydrogen uptake and diffusion in steels and discuss the outstanding challenges in modelling hydrogen diffusion in terms of hydrogen assisted cracking and optimal charging conditions in hydrogen permeation measurements.

Journal ArticleDOI
TL;DR: This paper is a review of research that contributes to the development of a geometrical calibration procedure for XCT systems, and the various methods that have been developed to measure certainGeometrical errors are reviewed.
Abstract: Industrial x-ray computed tomography (XCT) is seen as a potentially effective tool for the industrial inspection of complex parts. In particular, XCT is an attractive solution for the measurement of internal geometries, which are inaccessible by conventional coordinate measuring systems. While the technology is available and the benefits are recognized, methods to establish the measurement assurance of XCT systems are lacking. More specifically, the assessment of measurement uncertainty and the subsequent establishment of measurement traceability is a largely unknown process. This paper is a review of research that contributes to the development of a geometrical calibration procedure for XCT systems. A brief introduction to the geometry of cone-beam tomography systems is given, after which the geometrical influence factors are outlined. Mathematical measurement models play a significant role in understanding how geometrical offsets and misalignments contribute to error in measurements; therefore, the application of mathematical models in simulating geometrical errors is discussed and the corresponding literature is presented. Then, the various methods that have been developed to measure certain geometrical errors are reviewed. The findings from this review are discussed and suggestions are provided for future work towards the development of a comprehensive and practical geometrical calibration procedure.

Journal ArticleDOI
TL;DR: Chemical mapping of a photocatalytic reaction with nanoscale spatial resolution is demonstrated for the first time using tip-enhanced Raman spectroscopy (TERS) with near-field electromagnetic enhancement.
Abstract: Chemical mapping of a photocatalytic reaction with nanoscale spatial resolution is demonstrated for the first time using tip-enhanced Raman spectroscopy (TERS). An ultrathin alumina film applied to the Ag-coated TERS tip blocks catalytic interference whilst maintaining near-field electromagnetic enhancement, thus enabling spectroscopic imaging of catalytic activity on nanostructured Ag surfaces.

Journal ArticleDOI
TL;DR: In this paper, the authors present a review of the most promising high temperature polycrystalline materials where their properties allow operation above that of the ubiquitous commercial material lead zirconate titanate, as well as work done to modify a promising high-temperature system, for use as a material standard.
Abstract: Piezoelectric sensors and actuators are a mature technology, commonplace amongst a plethora of industrial fields including automotive, maritime and non-destructive testing. However the environments that these devices are required to serve in are becoming more demanding, with temperatures being driven higher to increase efficiencies and reduce shut-downs. Materials to survive these temperatures have been the focus of many research groups over the last decade, but there still remains no standard for the measurement of piezoelectric materials at high temperature. This is required to effectively determine comparable Figures of Merit into which devices can be successfully designed. As part of a recent European effort to establish metrological techniques for high temperature evaluation of electro-mechanical properties, we present here a review of the most promising high temperature polycrystalline materials. Where their properties allow operation above that of the ubiquitous commercial material lead zirconate titanate, as well as work done to modify a promising high temperature system, for use as a material standard.

Journal ArticleDOI
TL;DR: It is demonstrated that the failure to meet classical cavity theory requirements, such as CPE, is not the reason for significant quality correction factors and that what matters most, apart from volume averaging effects, is the relationship between the lack of CPE in the small field itself and the density of the detector cavity.
Abstract: Purpose: To explain the reasons for significant quality correction factors in megavoltage small photon fields and clarify the underlying concepts relevant to dosimetry under such conditions. Methods: The validity of cavity theory and the requirement of charged particle equilibrium (CPE) are addressed from a theoretical point of view in the context of nonstandard beams. Perturbation effects are described into four main subeffects, explaining their nature and pointing out their relative importance in small photon fields. Results: It is demonstrated that the failure to meet classical cavity theory requirements, such as CPE, is not the reason for significant quality correction factors. On the contrary, it is shown that the lack of CPE alone cannot explain these corrections and that what matters most, apart from volume averaging effects, is the relationship between the lack of CPE in the small field itself and the density of the detector cavity. The density perturbation effect is explained based on Fano’s theorem, describing the compensating effect of two main contributions to cavity absorbed dose. Using the same approach, perturbation effects arising from the difference in atomic properties of the cavity medium and the presence of extracameral components are explained. Volume averaging effects are also discussed in detail. Conclusions: Quality correction factors of small megavoltage photon fields are mainly due to differences in electron density between water and the detector medium and to volume averaging over the detector cavity. Other effects, such as the presence of extracameral components and differences in atomic properties of the detection medium with respect to water, can also play an accentuated role in small photon fields compared to standard beams.

Journal ArticleDOI
24 Aug 2015-Analyst
TL;DR: It is shown for the first time that the excreted metabolites of drugs of abuse can be detected in fingerprints using ambient mass spectrometry.
Abstract: Latent fingerprints provide a potential route to the secure, high throughput and non-invasive detection of drugs of abuse. In this study we show for the first time that the excreted metabolites of drugs of abuse can be detected in fingerprints using ambient mass spectrometry. Fingerprints and oral fluid were taken from patients attending a drug and alcohol treatment service. Gas chromatography mass spectrometry (GC-MS) was used to test the oral fluid of patients for the presence of cocaine and benzoylecgonine. The corresponding fingerprints were analysed using Desorption Electrospray Ionization (DESI) which operates under ambient conditions and Ion Mobility Tandem Mass Spectrometry Matrix Assisted Laser Desorption Ionization (MALDI-IMS-MS/MS) and Secondary Ion Mass Spectrometry (SIMS). The detection of cocaine, benzoylecgonine (BZE) and methylecgonine (EME) in latent fingerprints using both DESI and MALDI showed good correlation with oral fluid testing. The sensitivity of SIMS was found to be insufficient for this application. These results provide exciting opportunities for the use of fingerprints as a new sampling medium for secure, non-invasive drug detection. The mass spectrometry techniques used here offer a high level of selectivity and consume only a small area of a single fingerprint, allowing repeat and high throughput analyses of a single sample.

Journal ArticleDOI
TL;DR: Coordination polymers (CPs) are emerging as the next generation of macromolecules for many industrial and technological applications as mentioned in this paper, which offers the opportunity to exploit them as very effective adsorbents for gaseous molecules, including volatile organic compounds (VOCs).

Journal ArticleDOI
TL;DR: The calibration and verification infrastructure to support areal surface texture measurement and characterisation will be reviewed and the concept and current infrastructure for determining the metrological characteristics of instruments will be highlighted.

Journal ArticleDOI
20 Feb 2015
TL;DR: In this paper, the intrinsic electrostatic effects arising in monolayer and few-layer MoS2 from those influenced by the flake-substrate interaction were decoupled using ultrasonic force microscopy nanomechanical mapping.
Abstract: We have decoupled the intrinsic electrostatic effects arising in monolayer and few-layer MoS2 from those influenced by the flake-substrate interaction. Using ultrasonic force microscopy nanomechanical mapping, we identify the change from supported to suspended flake regions on a trenched substrate. These regions are correlated with the surface potential as measured by scanning Kelvin probe microscopy. Relative to the supported region, we observe an increase in surface potential contrast due to suppressed charge transfer for the suspended monolayer. Using Raman spectroscopy we observe a red shift of the E12g mode for monolayer MoS2 deposited on Si, consistent with a more strained MoS2 on the Si substrate compared to the Au substrate.

Journal ArticleDOI
TL;DR: In this paper, a comparison exercise on thermal-optical elemental carbon/organic carbon (ECOC) analysers was carried out among 17 European laboratories, and the participants made use of an identical instrument set-up, after correcting for temperature offsets with the application of a recently developed temperature calibration kit.
Abstract: . A comparison exercise on thermal-optical elemental carbon/organic carbon (ECOC) analysers was carried out among 17 European laboratories. Contrary to previous comparison exercises, the 17 participants made use of an identical instrument set-up, after correcting for temperature offsets with the application of a recently developed temperature calibration kit (Sunset Laboratory Inc, OR, US). Temperature offsets reported by participants ranged from −93 to +100 °C per temperature step. Five filter samples and two sucrose solutions were analysed with both the EUSAAR2 and NIOSH870 thermal protocols. z scores were calculated for total carbon (TC); nine outliers and three stragglers were identified. Three outliers and eight stragglers were found for EC. Overall, the participants provided results between the warning levels with the exception of two laboratories that showed poor performance, the causes of which were identified and corrected through the course of the comparison exercise. The TC repeatability and reproducibility (expressed as relative standard deviations) were 11 and 15% for EUSAAR2 and 9.2 and 12% for NIOSH870; the standard deviations for EC were 15 and 20% for EUSAAR2 and 20 and 26% for NIOSH870. TC was in good agreement between the two protocols, TCNIOSH870 = 0.98 × TCEUSAAR2 (R2 = 1.00, robust means). Transmittance (TOT) calculated EC for NIOSH870 was found to be 20% lower than for EUSAAR2, ECNIOSH870 = 0.80 × ECEUSAAR2 (R2 = 0.96, robust means). The thermograms and laser signal values were compared and similar peak patterns were observed per sample and protocol for most participants. Notable deviations from the typical patterns indicated either the absence or inaccurate application of the temperature calibration procedure and/or pre-oxidation during the inert phase of the analysis. Low or zero pyrolytic organic carbon (POC), as reported by a few participants, is suggested as an indicator of an instrument-specific pre-oxidation. A sample-specific pre-oxidation effect was observed for filter G, for all participants and both thermal protocols, indicating the presence of oxygen donors on the suspended particulate matter. POC (TOT) levels were lower for NIOSH870 than for EUSAAR2, which is related to the heating profile differences of the two thermal protocols.

Journal ArticleDOI
TL;DR: The use of EBT-XD is validated for high-dose, small-field radiotherapy, for routine QC and a forthcoming multi-centre SRS dosimetry intercomparison, and the effective atomic number for both may be considered water-equivalent in MV radiotherapy.
Abstract: There is renewed interest in film dosimetry for the verification of dose delivery of complex treatments, particularly small fields, compared to treatment planning system calculations. A new radiochromic film, Gafchromic EBT-XD, is available for high-dose treatment verification and we present the first published evaluation of its use. We evaluate the new film for MV photon dosimetry, including calibration curves, performance with single- and triple-channel dosimetry, and comparison to existing EBT3 film. In the verification of a typical 25 Gy stereotactic radiotherapy (SRS) treatment, compared to TPS planned dose distribution, excellent agreement was seen with EBT-XD using triple-channel dosimetry, in isodose overlay, maximum 1.0 mm difference over 200-2400 cGy, and gamma evaluation, mean passing rate 97% at 3% locally-normalised, 1.5 mm criteria. In comparison to EBT3, EBT-XD gave improved evaluation results for the SRS-plan, had improved calibration curve gradients at high doses, and had reduced lateral scanner effect. The dimensions of the two films are identical. The optical density of EBT-XD is lower than EBT3 for the same dose. The effective atomic number for both may be considered water-equivalent in MV radiotherapy. We have validated the use of EBT-XD for high-dose, small-field radiotherapy, for routine QC and a forthcoming multi-centre SRS dosimetry intercomparison.

Journal ArticleDOI
TL;DR: In this paper, the local environment experienced by a bipolar plate during fuel cell operation via in situ measurement of pH and corrosion potential for an uncoated 316L stainless steel bipolar plate in a single cell PEMFC was characterized.

Journal ArticleDOI
TL;DR: This work shows that LESA mass spectrometry may be coupled with high field asymmetric waveform ion mobility spectrometer (FAIMS) for top-down protein analysis directly from thin tissue sections and from bacterial colonies growing on agar.
Abstract: Previously we have shown that liquid extraction surface analysis (LESA) mass spectrometry is suitable for the analysis of intact proteins from a range of biological substrates. Here we show that LESA mass spectrometry may be coupled with high field asymmetric waveform ion mobility spectrometry (FAIMS) for top-down protein analysis directly from thin tissue sections (mouse liver, mouse brain) and from bacterial colonies (Escherichia coli) growing on agar. Incorporation of FAIMS results in significant improvements in signal-to-noise and reduced analysis time. Abundant protein signals are observed in single scan mass spectra. In addition, FAIMS enables gas-phase separation of molecular classes, for example, lipids and proteins, enabling improved analysis of both sets of species from a single LESA extraction.

Journal ArticleDOI
TL;DR: A modern approach to radiation dosimetry is defined for any detector and applied to small photon fields and Monte Carlo simulations are valuable to describe pencil beam perturbation effects and detail the nature of dosimetric factors in megavoltagesmall photon fields.
Abstract: Purpose: To quantify detector perturbation effects in megavoltage small photon fields and support the theoretical explanation on the nature of quality correction factors in these conditions. Methods: In this second paper, a modern approach to radiation dosimetry is defined for any detector and applied to small photon fields. Fano's theorem is adapted in the form of a cavity theory and applied in the context of nonstandard beams to express four main effects in the form of perturbation factors. The pencil-beam decomposition method is detailed and adapted to the calculation of perturbation factors and quality correction factors. The approach defines a perturbation function which, for a given field size or beam modulation, entirely determines these dosimetric factors. Monte Carlo calculations are performed in different cavity sizes for different detection materials, electron densities, and extracameral components. Results: Perturbation effects are detailed with calculated perturbation functions, showing the relative magnitude of the effects as well as the geometrical extent to which collimating or modulating the beam impacts the dosimetric factors. The existence of a perturbation zone around the detector cavity is demonstrated and the approach is discussed and linked to previous approaches in the literature to determine critical field sizes. Conclusions: Monte Carlo simulations are valuable to describe pencil beam perturbation effects and detail the nature of dosimetric factors in megavoltage small photon fields. In practice, it is shown that dosimetric factors could be avoided if the field size remains larger than the detector perturbation zone. However, given a detector and beam quality, a full account for the detector geometry is necessary to determine critical field sizes.

Journal ArticleDOI
TL;DR: The nanorods with unusually high optical bandgap for a VO2 material are effective in enhancing the thermal performance of ethylene glycol nanofluids over a wide temperature range as is indicated by the temperature dependent thermal conductivity measurements.
Abstract: VO2 (B) nanorods with average width ranging between 50-100 nm are synthesized via a hydrothermal method and the post hydrothermal treatment drying temperature is found to be influential in their overall phase and growth morphology evolution. The nanorods with unusually high optical bandgap for a VO2 material are effective in enhancing the thermal performance of ethylene glycol nanofluids over a wide temperature range as is indicated by the temperature dependent thermal conductivity measurements. Humidity and LPG sensors fabricated using the VO2 (B) nanorods bear testament to their efficient sensing performance, which can be partially attributed to the mesoporous nature of the nanorods.

Journal ArticleDOI
TL;DR: In this article, the antineutrino spectra measured in recent experiments at reactors are inconsistent with calculations based on the conversion of integral beta spectra recorded at the ILL reactor.
Abstract: The antineutrino spectra measured in recent experiments at reactors are inconsistent with calculations based on the conversion of integral beta spectra recorded at the ILL reactor. (92)Rb makes the dominant contribution to the reactor antineutrino spectrum in the 5-8 MeV range but its decay properties are in question. We have studied (92)Rb decay with total absorption spectroscopy. Previously unobserved beta feeding was seen in the 4.5-5.5 region and the GS to GS feeding was found to be 87.5(25)%. The impact on the reactor antineutrino spectra calculated with the summation method is shown and discussed.