scispace - formally typeset
Search or ask a question
Institution

National Physical Laboratory

FacilityLondon, United Kingdom
About: National Physical Laboratory is a facility organization based out in London, United Kingdom. It is known for research contribution in the topics: Dielectric & Thin film. The organization has 7615 authors who have published 13327 publications receiving 319381 citations.


Papers
More filters
Journal ArticleDOI
TL;DR: The viscous heating artefact has been characterized by comparison with novel thin-film thermocouples at 1-2 cm focal depths in fresh degassed ex vivo bovine liver and was found to be intensity independent up to 600 W cm(-2) (below the threshold for cavitation and lesion formation) and remained significant at radial distances out to the first side lobe in the focal plane.
Abstract: Accurate temperature measurements in therapeutic ultrasound fields are necessary for understanding damage mechanisms, verification of thermal modelling and calibration of non-invasive clinical thermometry. However, artefactual heating, primarily due to viscous forces which result from motion relative to the surrounding tissue, occurs when metal thermocouples are used in an ultrasound field. The magnitude and time dependence of this artefact has been characterized by comparison with novel thin-film thermocouples (TFTs) at 1-2 cm focal depths in fresh degassed ex vivo bovine liver. High-intensity focused ultrasound exposures (1.7 MHz; free-field spatial-peak temporal-average intensities 40-600 W cm(-2)) were used. Subtraction of the TFT data from that obtained for other thermocouples yielded the time dependence of the viscous heating artefact. This was found to be intensity independent up to 600 W cm(-2) (below the threshold for cavitation and lesion formation) and remained significant at radial distances out to the first side lobe in the focal plane. The contribution of viscous heating to cooling was also found to be significant for at least 5 s after the end of insonation. The ratio of viscous artefact to absorptive heating after 5 s was: 1.76 +/- 0.07 for a fine-wire, 0.45 +/- 0.07 and 1.93 +/- 0.07 for two different sheathed-wires and 0.24 +/- 0.07 for a needle thermocouple.

108 citations

Journal ArticleDOI
TL;DR: A monolithic, fixed-barrier single-electron pump made entirely from graphene that performs at frequencies up to several gigahertz is presented, bringing an all-graphene closure of the quantum metrological triangle within reach.
Abstract: A single electron pump made entirely from graphene that performs at frequencies up to several gigahertz is now realized

108 citations

Journal ArticleDOI
TL;DR: It is shown that thicknesses derived from XPS data linearly correlated with spectroscopic ellipsometry data on the same samples with a scatter of 10%.
Abstract: Protein adsorption at solid surfaces is central to many phenomena of medical and technological interest. The determination of the amount of protein attached to the surface is a critical measurement performed by using a wide range of methods. X-ray photoelectron spectroscopy (XPS) is able to provide a straightforward quantitative analysis of the amount of protein adsorbed as an overlayer on a material surface. While XPS is commonly employed to assess qualitatively the amount of adsorbed protein, this is usually expressed in terms of the elemental fraction (or at. %) of nitrogen calculated using an assumption of depth homogeneity despite the fact that this does not linearly scale with the amount of protein. In this paper, we have shown that thicknesses derived from XPS data linearly correlated with spectroscopic ellipsometry data on the same samples with a scatter of 10%. A straightforward equation to convert the concentration of nitrogen from XPS into an equivalent thickness of a protein film is presented....

108 citations

Journal ArticleDOI
01 Jan 1977-Polymer
TL;DR: In this article, specific volumes of a series of anionic polystyrenes (M = 2000 to 2 000 000) have been measured dilatometrically over the temperature range −30° to 210°C.

108 citations

Journal ArticleDOI
TL;DR: In this paper, a new primary CMM with a target uncertainty of 300 nm (k = 1.96) within a cubic working volume of side 600 mm has been developed to address the industrial requirement for the calibration of 2D and 3D objects.

108 citations


Authors

Showing all 7655 results

NameH-indexPapersCitations
Rajesh Kumar1494439140830
Akhilesh Pandey10052953741
A. S. Bell9030561177
David R. Clarke9055336039
Praveen Kumar88133935718
Richard C. Thompson8738045702
Xin-She Yang8544461136
Andrew J. Pollard7967326295
Krishnendu Chakrabarty7999627583
Vinod Kumar7781526882
Bansi D. Malhotra7537519419
Matthew Hall7582724352
Sanjay K. Srivastava7336615587
Michael Jones7233118889
Sanjay Singh71113322099
Network Information
Related Institutions (5)
National Institute of Standards and Technology
60.6K papers, 2.2M citations

90% related

National Research Council
76K papers, 2.4M citations

89% related

Los Alamos National Laboratory
74.6K papers, 2.9M citations

88% related

Centre national de la recherche scientifique
382.4K papers, 13.6M citations

87% related

Argonne National Laboratory
64.3K papers, 2.4M citations

87% related

Performance
Metrics
No. of papers from the Institution in previous years
YearPapers
202315
202242
2021356
2020438
2019434
2018406