Institution
National Physical Laboratory
Facility•London, United Kingdom•
About: National Physical Laboratory is a facility organization based out in London, United Kingdom. It is known for research contribution in the topics: Dielectric & Thin film. The organization has 7615 authors who have published 13327 publications receiving 319381 citations.
Papers published on a yearly basis
Papers
More filters
••
TL;DR: In this article, preliminary studies of gel electrolytes based on PMMA and solutions of the lithium salt LiN (CF 3 SO 2 ) 2 in propylene carbonate (PC) and the mixed solvent PC+EC are presented.
97 citations
••
TL;DR: The Radiometric Calibration Network (RadCalNet) is an effort to provide automated surface and atmosphere in situ data as part of a network including multiple sites for the purpose of optical imager radiometric calibration in the visible to shortwave infrared spectral range.
Abstract: Vicarious calibration approaches using in situ measurements saw first use in the early 1980s and have since improved to keep pace with the evolution of the radiometric requirements of the sensors that are being calibrated. The advantage of in situ measurements for vicarious calibration is that they can be carried out with traceable and quantifiable accuracy, making them ideal for interconsistency studies of on-orbit sensors. The recent development of automated sites to collect the in situ data has led to an increase in the available number of datasets for sensor calibration. The current work describes the Radiometric Calibration Network (RadCalNet) that is an effort to provide automated surface and atmosphere in situ data as part of a network including multiple sites for the purpose of optical imager radiometric calibration in the visible to shortwave infrared spectral range. The key goals of RadCalNet are to standardize protocols for collecting data, process to top-of-atmosphere reflectance, and provide uncertainty budgets for automated sites traceable to the international system of units. RadCalNet is the result of efforts by the RadCalNet Working Group under the umbrella of the Committee on Earth Observation Satellites (CEOS) Working Group on Calibration and Validation (WGCV) and the Infrared Visible Optical Sensors (IVOS). Four radiometric calibration instrumented sites located in the USA, France, China, and Namibia are presented here that were used as initial sites for prototyping and demonstrating RadCalNet. All four sites rely on collection of data for assessing the surface reflectance as well as atmospheric data over that site. The data are converted to top-of-atmosphere reflectance within RadCalNet and provided through a web portal to allow users to either radiometrically calibrate or verify the calibration of their sensors of interest. Top-of-atmosphere reflectance data with associated uncertainties are available at 10 nm intervals over the 400 nm to 1000 nm spectral range at 30 min intervals for a nadir-viewing geometry. An example is shown demonstrating how top-of-atmosphere data from RadCalNet can be used to determine the interconsistency between two sensors.
97 citations
••
TL;DR: In this article, a p-n junction PEDOT:PSS was used for energy harvesting in ZnO nanorods, and the voltage and current output were measured to be in the range of 10 mV and 10 μA cm−2.
Abstract: Piezoelectric ZnO nanorods grown on a flexible substrate are combined with the p-type semiconducting polymer PEDOT:PSS to produce a p-n junction device that successfully demonstrates kinetic-to-electrical energy conversion. Both the voltage and current output of the devices are measured to be in the range of 10 mV and 10 μA cm−2. Combining these figures for the best device gives a maximum possible power density of 0.4 mW cm−3. Systematic testing of the devices is performed showing that the voltage output increases linearly with applied stress, and is reduced significantly by illumination with super-band gap light. This provides strong evidence that the voltage output results from piezoelectric effects in the ZnO. The behavior of the devices is explained by considering the time-dependent changes in band structure resulting from the straining of a piezoelectric material within a p-n junction. It is shown that the rate of screening of the depolarisation field determines the power output of a piezoelectric energy harvesting device. This model is consistent with the behavior of a number of previous devices utilising the piezoelectric effect in ZnO.
97 citations
••
TL;DR: In this paper, the authors studied the thickness dependence of transparent conducting indium-doped ZnO films and found that the density of trap states due to chemisorbed oxygen at the grain boundaries was found to depend on the orientation of grains which depended on the film thickness.
96 citations
••
TL;DR: In this article, the authors reported synthesis of aqueous based gold coated iron oxide nanoparticles to integrate the localized surface plasma resonance (SPR) properties of gold and magnetic properties of iron oxide in a single system.
96 citations
Authors
Showing all 7655 results
Name | H-index | Papers | Citations |
---|---|---|---|
Rajesh Kumar | 149 | 4439 | 140830 |
Akhilesh Pandey | 100 | 529 | 53741 |
A. S. Bell | 90 | 305 | 61177 |
David R. Clarke | 90 | 553 | 36039 |
Praveen Kumar | 88 | 1339 | 35718 |
Richard C. Thompson | 87 | 380 | 45702 |
Xin-She Yang | 85 | 444 | 61136 |
Andrew J. Pollard | 79 | 673 | 26295 |
Krishnendu Chakrabarty | 79 | 996 | 27583 |
Vinod Kumar | 77 | 815 | 26882 |
Bansi D. Malhotra | 75 | 375 | 19419 |
Matthew Hall | 75 | 827 | 24352 |
Sanjay K. Srivastava | 73 | 366 | 15587 |
Michael Jones | 72 | 331 | 18889 |
Sanjay Singh | 71 | 1133 | 22099 |