scispace - formally typeset
Search or ask a question
Institution

Paul Scherrer Institute

FacilityVilligen, Switzerland
About: Paul Scherrer Institute is a facility organization based out in Villigen, Switzerland. It is known for research contribution in the topics: Neutron & Large Hadron Collider. The organization has 9248 authors who have published 23984 publications receiving 890129 citations. The organization is also known as: PSI.


Papers
More filters
Journal ArticleDOI
TL;DR: The degree of substitution of Si(4+) by Al(3+) in the oxygen-terminated tetrahedra (Al T-sites) of zeolites determines the concentration of ion-exchange and Brønsted acid sites and is observed that identical zeolite types show dramatically different Al distributions.
Abstract: The degree of substitution of Si4+ by Al3+ in the oxygen-terminated tetrahedra (Al T-sites) of zeolites determines the concentration of ion-exchange and Bronsted acid sites. Because the location of the tetrahedra and the associated subtle variations in bond angles influence the acid strength, quantitative information about Al T-sites in the framework is critical to rationalize catalytic properties and to design new catalysts. A quantitative analysis is reported that uses a combination of extended X-ray absorption fine structure (EXAFS) analysis and 27Al MAS NMR spectroscopy supported by DFT-based molecular dynamics simulations. To discriminate individual Al atoms, sets of ab initio EXAFS spectra for various T-sites are generated from DFT-based molecular dynamics simulations, allowing quantitative treatment of the EXAFS single- and multiple-photoelectron scattering processes out to 3–4 atom shells surrounding the Al absorption center. It is observed that identical zeolite types show dramatically different ...

183 citations

Journal ArticleDOI
TL;DR: In this article, a temperature-vacuum swing (TVS) process was used to extract pure CO2 from dry and humid atmospheric air, and the results showed that up to 158 ml of CO2 (6.8 ml per gram) with a purity of up to 97.6% was recovered per cycle.
Abstract: A temperature-vacuum swing (TVS) process, capable of extracting pure CO2 from dry and humid atmospheric air, is experimentally analyzed. Adsorption/desorption cycles utilizing a packed bed of a sorbent material made of diamine-functionalized commercial silica gel are performed under equilibrium and non-equilibrium (short-cycle) conditions. Thereby, the CO2 capture capacity of the material is determined over a wide range of operational parameters, namely 10–150 mbarabs desorption pressure, 74–90 °C desorption temperature, and 0–80% relative humidity during adsorption. Up to 158 ml of CO2 (6.8 ml per gram sorbent) with a purity of up to 97.6% is recovered per cycle. Adsorption isotherms of the sorbent material are experimentally determined by thermogravimetry and fitted to isotherm models, which are successfully applied to predict desorption capacities achieved in the TVS process. Under dry conditions, desorption pressures above 100 mbarabs lead to strongly decreasing CO2 capture capacities below 0.03 mmol g−1. Under humid conditions with 40% relative humidity during adsorption, the desorption pressure can be raised to 150 mbarabs with capture capacities remaining above 0.2 mmol g−1. Stable performance of the sorbent material in the TVS process is demonstrated over 40 consecutive adsorption/desorption cycles.

183 citations

Journal ArticleDOI
TL;DR: In this paper, the sensitivity of the SP2 to different BC types was determined, using an aerosol particle mass analyzer, for rBC from thermodenuded diesel exhaust, wood burning exhaust and ambient particles as well as for commercially available products: Aquadag® and fullerene soot.
Abstract: . Black carbon (BC) is now mainly of anthropogenic origin. It is the dominant light absorbing component of atmospheric aerosols, playing an important role in the earth's radiative balance and therefore relevant to climate change studies. In addition, BC is known to be harmful to human beings making it relevant to policy makers. Nevertheless, the measurement of BC remains biased by the instrument-based definition of BC. The Single Particle Soot Photometer (SP2), allows the measurement of the refractory BC (rBC) mass of individual particles using laser-induced incandescence. However, the SP2 needs an empirical calibration to retrieve the rBC mass from the incandescence signal and the sensitivity of the SP2 differs between different BC types. Ideally, for atmospheric studies, the SP2 should be calibrated using ambient particles containing a known mass of ambient rBC. However, such "ambient BC" calibration particles cannot easily be obtained and thus commercially available BC particles are commonly used for SP2 calibration instead. In this study we tested the sensitivity of the SP2 to different BC types in order to characterize the potential error introduced by using non-ambient BC for calibration. The sensitivity of the SP2 was determined, using an aerosol particle mass analyzer, for rBC from thermodenuded diesel exhaust, wood burning exhaust and ambient particles as well as for commercially available products: Aquadag® and fullerene soot. Thermodenuded, fresh diesel exhaust has been found to be ideal for SP2 calibration for two reasons. First, the small amount of non-BC matter upon emission reduces the risk of bias due to incomplete removal of non-BC matter and second, it is considered to represent atmospheric rBC in urban locations where diesel exhaust is the main source of BC. The SP2 was found to be up to 16% less sensitive to rBC from thermodenuded ambient particles (≤15 fg) than rBC from diesel exhaust, however, at least part of this difference can be explained by incomplete removal of non-refractory components in the thermodenuder. The amount of remaining non-refractory matter was estimated to be below 30% by mass, according to a comparison of the scattering cross sections of the whole particles with that of the pure BC cores. The SP2 sensitivity to rBC from wood burning exhaust agrees with the SP2 sensitivity to rBC from diesel exhaust within an error of less than 14% (≤40 fg). If, due to experimental restrictions, diesel exhaust cannot be used, untreated fullerene soot was found to give an SP2 calibration curve similar to diesel exhaust and ambient rBC (within ±10% for a rBC mass ≤15 fg) and is therefore recommended although two different batches differed by ~14% between themselves. In addition, the SP2 was found to be up to 40% more sensitive to Aquadag® than to diesel exhaust rBC. Therefore Aquadag® cannot be recommended for atmospheric application without accounting for the sensitivity difference. These findings for fullerene soot and Aquadag® confirm results from previous literature.

183 citations

Journal ArticleDOI
TL;DR: In this paper, the effect of aerosol water uptake on the aerosol particle light scattering coefficient (σsp) is described by comparing measurements from five European sites: the Jungfraujoch, located in the Swiss Alps at 3580 m a.s.l., Ny-Alesund, located on Spitsbergen in the Arctic, Mace Head, a coastal site in Ireland, Cabauw, a rural site in the Netherlands; and Melpitz, a regional background site in Eastern Germany.
Abstract: . The effect of aerosol water uptake on the aerosol particle light scattering coefficient (σsp) is described in this study by comparing measurements from five European sites: the Jungfraujoch, located in the Swiss Alps at 3580 m a.s.l.; Ny-Alesund, located on Spitsbergen in the Arctic; Mace Head, a coastal site in Ireland; Cabauw, a rural site in the Netherlands; and Melpitz, a regional background site in Eastern Germany. These sites were selected according to the aerosol type usually encountered at that location. The scattering enhancement factor f(RH, λ) is the key parameter to describe the effect of water uptake on the particle light scattering. It is defined as the σsp(RH) at a certain relative humidity (RH) and wavelength λ divided by its dry value. f(RH) at the five sites varied widely, starting at very low values of f(RH = 85%, λ = 550 nm) around 1.28 for mineral dust, and reaching up to 3.41 for Arctic aerosol. Hysteresis behavior was observed at all sites except at the Jungfraujoch (due to the absence of sea salt). Closure studies and Mie simulations showed that both size and chemical composition determine the magnitude of f(RH). Both parameters are also needed to successfully predict f(RH). Finally, the measurement results were compared to the widely used aerosol model, OPAC (Hess et al., 1998). Significant discrepancies were seen, especially at intermediate RH ranges; these were mainly attributed to inappropriate implementation of hygroscopic growth in the OPAC model. Replacement of the hygroscopic growth with values from the recent literature resulted in a clear improvement of the OPAC model.

183 citations


Authors

Showing all 9348 results

NameH-indexPapersCitations
Andrea Bocci1722402176461
Tobin J. Marks1591621111604
Wolfgang Wagner1562342123391
David D'Enterria1501592116210
Andreas Pfeiffer1491756131080
Christoph Grab1441359144174
Maurizio Pierini1431782104406
Alexander Belyaev1421895100796
Ajit Kumar Mohanty141112493062
Felicitas Pauss1411623104493
Chiara Mariotti141142698157
Luc Pape1411441130253
Rainer Wallny1411661105387
Roland Horisberger1391471100458
Emmanuelle Perez138155099016
Network Information
Related Institutions (5)
Los Alamos National Laboratory
74.6K papers, 2.9M citations

93% related

Argonne National Laboratory
64.3K papers, 2.4M citations

93% related

Lawrence Berkeley National Laboratory
66.5K papers, 4.1M citations

93% related

Oak Ridge National Laboratory
73.7K papers, 2.6M citations

93% related

Centre national de la recherche scientifique
382.4K papers, 13.6M citations

89% related

Performance
Metrics
No. of papers from the Institution in previous years
YearPapers
202363
2022199
20211,299
20201,442
20191,330
20181,298