scispace - formally typeset
Search or ask a question
Institution

Paul Scherrer Institute

FacilityVilligen, Switzerland
About: Paul Scherrer Institute is a facility organization based out in Villigen, Switzerland. It is known for research contribution in the topics: Neutron & Large Hadron Collider. The organization has 9248 authors who have published 23984 publications receiving 890129 citations. The organization is also known as: PSI.


Papers
More filters
Journal ArticleDOI
A. Adam1, M. Aguilar-Benitez, J. Alarcon, J. Alberdi  +150 moreInstitutions (13)
TL;DR: The forward-backward muon detector of the L3 experiment is presented in this paper, which consists of 96 self-calibrating drift chambers of a new design enclosing the magnet pole pieces of the l3 solenoid.
Abstract: The forward-backward muon detector of the L3 experiment is presented. Intended to be used for LEP 200 physics, it consists of 96 self-calibrating drift chambers of a new design enclosing the magnet pole pieces of the L3 solenoid. The pole pieces are toroidally magnetized to form two independent analyzing spectrometers. A novel trigger is provided by resistive plate counters attached to the drift chambers. Details about the design, construction and performance of the whole system are given together with results obtained during the 1995 running at LEP.

177 citations

Journal ArticleDOI
TL;DR: In this paper, the authors measured diffusivity, permeability, and electric conductivity of a common gas diffusion layer (GDL) material in PEFCs under various levels of compression.
Abstract: Understanding the transport properties of porous materials plays an important role in the development and optimization of polymer electrolyte fuel cells (PEFCs). In this study numerical simulations of different transport properties are compared and validated with data obtained using recently developed experimental techniques. The study is based on a Toray TGP-H-060 carbon paper, a common gas diffusion layer (GDL) material in PEFC. Diffusivity, permeability, and electric conductivity of the anisotropic, porous material are measured experimentally under various levels of compression. A sample of the GDL is imaged with synchrotron-based X-ray tomography under three different compression levels. Based on these three-dimensional images, diffusivity, permeability, and conductivity are calculated numerically. Experimental and numerical results agree in general. Deviations are observed for the through-plane conductivity. An explanation for the discrepancy is presented and affirmed by numerical simulations on a virtually created structure model. This proves that numerical simulation based on tomography data is a versatile tool for the investigation and development of porous structures used in PEFCs.

177 citations

Journal ArticleDOI
TL;DR: From the obtained results, it is confident to be able to treat moderately moving targets on Gantry 2 using repainted pencil-beam spot scanning and Continuous line scanning seems to be the most elegant solution; it provides higher repainting rates and produces superior results but is probably more difficult to realize.
Abstract: Treating moving targets using a scanning gantry for proton therapy is a promising but very challenging, not yet clinically demonstrated treatment modality. The interference of organ motion with the sequence of the beam delivery produces uncontrolled dose inhomogeneities within the target. One promising approach to overcome this difficulty is to increase the speed of scanning in order to apply the dose repeatedly (so-called repainting). To obtain sufficiently high scanning speeds a new, technologically improved gantry-Gantry 2-has been designed and is currently under construction at PSI. As there are many possible repainting strategies, the way repainting will be implemented on Gantry 2 will depend on the result of a careful analysis of the various treatment delivery strategies available. To achieve this aim, and prior to the start of experimental work with Gantry 2, simulations of dose distribution errors due to organ motion under various beam delivery strategies were investigated. The effects of motion on the dose distribution were studied for moderate motion amplitudes (5 mm) for spherical target volumes in a homogeneous medium and with homogeneous dose. In total over 200,000 dose distributions have been simulated and analyzed and selected results are discussed. From the obtained results we are confident to be able to treat moderately moving targets on Gantry 2 using repainted pencil-beam spot scanning. Continuous line scanning seems to be the most elegant solution; it provides higher repainting rates and produces superior results but is probably more difficult to realize. For larger motion amplitudes, continuous line scanning still shows good results, but we plan anyways to use a gating system for these cases, not only to reduce the inhomogeneity within the target volume but also to reduce safety margins.

177 citations

Journal ArticleDOI
TL;DR: Making use of the anomalous scrolling, it is possible to fabricate three-dimensional helices with helicity angles less than 45 degrees, which is advantageous for micro- and nanoelectromechanical systems.
Abstract: The fabrication of nanohelices by the scrolling of strained bilayers is investigated. It is shown that structure design is dominated by edge effects rather than bulk crystal properties such as the Young's modulus when the dimensions of the structures are reduced below 400 nm. SiGe/Si/Cr, SiGe/Si, and Si/Cr helical nanobelts are used as test structures. Dimensions of the belt width are reduced from 1.30 μm to 300 nm, and parameters controlling helicity angle, chirality, diameter, and pitch of the nanohelices are investigated. An anomalous scrolling direction deviating from the preferred 〈100〉 scrolling direction has been found for small structures. Making use of the anomalous scrolling, it is possible to fabricate three-dimensional helices with helicity angles less than 45°, which is advantageous for micro- and nanoelectromechanical systems.

177 citations

Journal ArticleDOI
TL;DR: In this paper, a method is demonstrated that relies on hard synchrotron X-rays to obtain diffraction images of shales and applies the crystallographic Rietveld method to deconvolute the images and extract quantitative information about phase fractions and preferred orientation that can then be used to model macroscopic physical properties.
Abstract: Anisotropy in clay-rich sedimentary rocks is receiving increasing attention. Seismic anisotropy is essential in the prospecting for petroleum deposits. Anisotropy of diffusion has become relevant for environmental contaminants, including nuclear waste. In both cases, the orientation of component minerals is a critical ingredient and, largely because of small grain size and poor crystallinity, the orientation distribution of clay minerals has been difficult to quantify. A method is demonstrated that relies on hard synchrotron X-rays to obtain diffraction images of shales and applies the crystallographic Rietveld method to deconvolute the images and extract quantitative information about phase fractions and preferred orientation that can then be used to model macroscopic physical properties. The method is applied to shales from European studies which investigate the suitability of shales as potential nuclear waste repositories (Meuse/Haute-Marne Underground Research Laboratory near Bure, France, and Benken borehole and Mont Terri Rock Laboratory, Switzerland). A Callovo-Oxfordian shale from Meuse/Haute-Marne shows a relatively weak alignment of clay minerals and a random distribution for calcite. Opalinus shales from Benken and Mont Terri show strong alignment of illite-smectite, kaolinite, chlorite, and calcite. This intrinsic contribution to anisotropy is consistent with macroscopic physical properties where anisotropy is caused both by the orientation distribution of crystallites and high-aspect-ratio pores. Polycrystal elastic properties are obtained by averaging single crystal properties over the orientation distribution and polyphase properties by averaging over all phases. From elastic properties we obtain anisotropies for p waves ranging from 7 to 22%.

176 citations


Authors

Showing all 9348 results

NameH-indexPapersCitations
Andrea Bocci1722402176461
Tobin J. Marks1591621111604
Wolfgang Wagner1562342123391
David D'Enterria1501592116210
Andreas Pfeiffer1491756131080
Christoph Grab1441359144174
Maurizio Pierini1431782104406
Alexander Belyaev1421895100796
Ajit Kumar Mohanty141112493062
Felicitas Pauss1411623104493
Chiara Mariotti141142698157
Luc Pape1411441130253
Rainer Wallny1411661105387
Roland Horisberger1391471100458
Emmanuelle Perez138155099016
Network Information
Related Institutions (5)
Los Alamos National Laboratory
74.6K papers, 2.9M citations

93% related

Argonne National Laboratory
64.3K papers, 2.4M citations

93% related

Lawrence Berkeley National Laboratory
66.5K papers, 4.1M citations

93% related

Oak Ridge National Laboratory
73.7K papers, 2.6M citations

93% related

Centre national de la recherche scientifique
382.4K papers, 13.6M citations

89% related

Performance
Metrics
No. of papers from the Institution in previous years
YearPapers
202363
2022199
20211,299
20201,442
20191,330
20181,298