Institution
Paul Scherrer Institute
Facility•Villigen, Switzerland•
About: Paul Scherrer Institute is a facility organization based out in Villigen, Switzerland. It is known for research contribution in the topics: Neutron & Large Hadron Collider. The organization has 9248 authors who have published 23984 publications receiving 890129 citations. The organization is also known as: PSI.
Topics: Neutron, Large Hadron Collider, Aerosol, Magnetization, Muon
Papers published on a yearly basis
Papers
More filters
••
Vardan Khachatryan, Albert M. Sirunyan, Armen Tumasyan, Wolfgang Adam1 +2184 more•Institutions (152)
TL;DR: In this article, the production of J/psi mesons from b-hadron decays at the LHC was studied in pp collisions at 6.5 to 30 GeV/c and in three rapidity ranges.
Abstract: The production of J/psi mesons is studied in pp collisions at sqrt(s)=7 TeV with the CMS experiment at the LHC. The measurement is based on a dimuon sample corresponding to an integrated luminosity of 314 inverse nanobarns. The J/psi differential cross section is determined, as a function of the J/psi transverse momentum, in three rapidity ranges. A fit to the decay length distribution is used to separate the prompt from the non-prompt (b hadron to J/psi) component. Integrated over J/psi transverse momentum from 6.5 to 30 GeV/c and over rapidity in the range |y| < 2.4, the measured cross sections, times the dimuon decay branching fraction, are 70.9 \pm 2.1 (stat.) \pm 3.0 (syst.) \pm 7.8(luminosity) nb for prompt J/psi mesons assuming unpolarized production and 26.0 \pm 1.4 (stat.) \pm 1.6 (syst.) \pm 2.9 (luminosity) nb for J/psi mesons from b-hadron decays.
175 citations
••
175 citations
••
TL;DR: For the patients in this study, 2y-LC could be preserved in the presence of interplay using a large spot size and conventional fractionation, and for treatments using smaller spot sizes and/or in the delivery of single fractions, interplay effects can lead to significant deterioration of the dose distribution and lower 2Y-LC.
Abstract: Purpose To quantify the impact of respiratory motion on the treatment of lung tumors with spot scanning proton therapy. Methods and Materials Four-dimensional Monte Carlo simulations were used to assess the interplay effect, which results from relative motion of the tumor and the proton beam, on the dose distribution in the patient. Ten patients with varying tumor sizes (2.6-82.3 cc) and motion amplitudes (3-30 mm) were included in the study. We investigated the impact of the spot size, which varies between proton facilities, and studied single fractions and conventionally fractionated treatments. The following metrics were used in the analysis: minimum/maximum/mean dose, target dose homogeneity, and 2-year local control rate (2y-LC). Results Respiratory motion reduces the target dose homogeneity, with the largest effects observed for the highest motion amplitudes. Smaller spot sizes (σ ≈ 3 mm) are inherently more sensitive to motion, decreasing target dose homogeneity on average by a factor 2.8 compared with a larger spot size (σ ≈ 13 mm). Using a smaller spot size to treat a tumor with 30-mm motion amplitude reduces the minimum dose to 44.7% of the prescribed dose, decreasing modeled 2y-LC from 87.0% to 2.7%, assuming a single fraction. Conventional fractionation partly mitigates this reduction, yielding a 2y-LC of 71.6%. For the large spot size, conventional fractionation increases target dose homogeneity and prevents a deterioration of 2y-LC for all patients. No correlation with tumor volume is observed. The effect on the normal lung dose distribution is minimal: observed changes in mean lung dose and lung V 20 are Conclusions For the patients in this study, 2y-LC could be preserved in the presence of interplay using a large spot size and conventional fractionation. For treatments using smaller spot sizes and/or in the delivery of single fractions, interplay effects can lead to significant deterioration of the dose distribution and lower 2y-LC.
175 citations
••
TL;DR: In this paper, extremely high concentrations (i.e., 4-20 times higher than the World Health Organization guideline) of PM2.5 (particulate matter with an aerodynamic diameter) were reported during winter 2013.
Abstract: . During winter 2013, extremely high concentrations (i.e., 4–20 times higher than the World Health Organization guideline) of PM2.5 (particulate matter with an aerodynamic diameter
175 citations
••
TL;DR: In this article, the authors performed continuous measurements of aerosol emissions within the scope of emission measurements in the Gubrist tunnel, a 3250 m long freeway tunnel near Zurich, Switzerland, from 20 September to 26 September 1993.
174 citations
Authors
Showing all 9348 results
Name | H-index | Papers | Citations |
---|---|---|---|
Andrea Bocci | 172 | 2402 | 176461 |
Tobin J. Marks | 159 | 1621 | 111604 |
Wolfgang Wagner | 156 | 2342 | 123391 |
David D'Enterria | 150 | 1592 | 116210 |
Andreas Pfeiffer | 149 | 1756 | 131080 |
Christoph Grab | 144 | 1359 | 144174 |
Maurizio Pierini | 143 | 1782 | 104406 |
Alexander Belyaev | 142 | 1895 | 100796 |
Ajit Kumar Mohanty | 141 | 1124 | 93062 |
Felicitas Pauss | 141 | 1623 | 104493 |
Chiara Mariotti | 141 | 1426 | 98157 |
Luc Pape | 141 | 1441 | 130253 |
Rainer Wallny | 141 | 1661 | 105387 |
Roland Horisberger | 139 | 1471 | 100458 |
Emmanuelle Perez | 138 | 1550 | 99016 |