scispace - formally typeset
Search or ask a question
Institution

Philips

CompanyVantaa, Finland
About: Philips is a company organization based out in Vantaa, Finland. It is known for research contribution in the topics: Signal & Layer (electronics). The organization has 68260 authors who have published 99663 publications receiving 1882329 citations. The organization is also known as: Koninklijke Philips Electronics N.V. & Royal Philips Electronics.


Papers
More filters
Patent
23 Jun 2005
TL;DR: In this paper, the driving and control device according to the present invention provides a desired switched current to a load including a string of one or more electronic devices, and comprises one or multiple voltage conversion means, one or several dimming control means, feedback means and one or many sensing means.
Abstract: The driving and control device according to the present invention provides a desired switched current to a load including a string of one or more electronic devices, and comprises one or more voltage conversion means, one or more dimming control means, one or more feedback means and one or more sensing means. The voltage conversion means may be a DC-to-DC converter for example and based on an input control signal converts the magnitude of the voltage from the power supply to another magnitude that is desired at the high side of the load. The dimming control means may comprise a switch such as a FET, BJT, relay, or any other type of switching device, for example, and provides control for activation and deactivation of the load. The feedback means is coupled to the voltage conversion means and a current sensing means and provides a feedback signal to the voltage conversion means that is indicative of the voltage drop across the current sensing means which thus represents the current flowing through the load. The current sensing means may comprise a fixed resistor, variable resistor, inductor, or some other element which has a predictable voltage-current relationship and thus will provide a measurement of the current flowing through the load based on a collected voltage signal. Based on the feedback signal received, the voltage conversion means can subsequently adjust its output voltage such that a constant switched current is provided to the load.

293 citations

Journal ArticleDOI
TL;DR: Foot and shoulders are the best alternatives to the finger for ambulatory measurement of skin conductance to reflect emotional arousal, and can help new applications using skin Conductance, like automated emotion measurements, to come to fruition.

292 citations

Journal ArticleDOI
TL;DR: The state-of-the-art methods for optical intra-operative 3D reconstruction in laparoscopic surgery is reviewed and the technical challenges and future perspectives towards clinical translation are discussed.

292 citations

Journal ArticleDOI
TL;DR: The five industrial software architecture design methods are compared and it is found that the five approaches have a lot in common and match more or less the ''ideal'' pattern that can be used for further method comparisons.

292 citations

Journal ArticleDOI
TL;DR: It is concluded that the whole‐heart coronary MRA technique improves visible vessel length and facilitates high‐quality coronary M RA of the complete coronary artery tree in a single measurement.
Abstract: Current implementations of coronary artery magnetic resonance angiography (MRA) suffer from limited coverage of the coronary arterial system. Whole-heart coronary MRA was implemented based on a free-breathing steady-state free-precession (SSFP) technique with magnetization preparation. The technique was compared to a similar implementation of conventional, thin-slab coronary MRA in 12 normal volunteers. Three thin-slab volumes were prescribed: 1) a transverse slab, covering the left main (LM) artery and proximal segments of the left anterior ascending (LAD) and left circumflex (LCX) coronary arteries; 2) a double-oblique slab covering the right coronary artery (RCA); and 3) a double-oblique slab covering the proximal and distal segments of the LCX. The whole-heart data set was reformatted in identical orientations. Visible vessel length, vessel sharpness, and vessel diameter were determined and compared separately for each vessel. Whole-heart coronary MRA visualized LM/LAD (11.7 +/- 3.4 cm) and LCX (6.9 +/- 3.6 cm) over a significantly longer distance than the transverse volume (LM/LAD, 6.1 +/- 1.1 cm, P < 0.001; LCX, 4.2 +/- 1.2 cm, P < 0.05). Improvements in visible vessel length for RCA and LCX in the whole-heart approach vs. their respective targeted volumes were not significant. It is concluded that the whole-heart coronary MRA technique improves visible vessel length and facilitates high-quality coronary MRA of the complete coronary artery tree in a single measurement.

291 citations


Authors

Showing all 68268 results

NameH-indexPapersCitations
Mark Raymond Adams1471187135038
Dario R. Alessi13635474753
Mohammad Khaja Nazeeruddin12964685630
Sanjay Kumar120205282620
Mark W. Dewhirst11679757525
Carl G. Figdor11656652145
Mathias Fink11690051759
David B. Solit11446952340
Giulio Tononi11451158519
Jie Wu112153756708
Claire M. Fraser10835276292
Michael F. Berger10754052426
Nikolaus Schultz106297120240
Rolf Müller10490550027
Warren J. Manning10260638781
Network Information
Related Institutions (5)
Katholieke Universiteit Leuven
176.5K papers, 6.2M citations

91% related

Georgia Institute of Technology
119K papers, 4.6M citations

88% related

Stanford University
320.3K papers, 21.8M citations

88% related

National University of Singapore
165.4K papers, 5.4M citations

88% related

IBM
253.9K papers, 7.4M citations

88% related

Performance
Metrics
No. of papers from the Institution in previous years
YearPapers
20235
202239
2021898
20201,428
20191,665
20181,378