scispace - formally typeset
Search or ask a question
Institution

Riverside Methodist Hospital

HealthcareColumbus, Ohio, United States
About: Riverside Methodist Hospital is a healthcare organization based out in Columbus, Ohio, United States. It is known for research contribution in the topics: Stroke & Stent. The organization has 667 authors who have published 797 publications receiving 37036 citations. The organization is also known as: Protestant Hospital & Riverside Hospital.


Papers
More filters
Journal ArticleDOI
TL;DR: Among patients with acute stroke who had last been known to be well 6 to 24 hours earlier and who had a mismatch between clinical deficit and infarct, outcomes for disability at 90 days were better with thrombectomy plus standard care than with standard care alone.
Abstract: BackgroundThe effect of endovascular thrombectomy that is performed more than 6 hours after the onset of ischemic stroke is uncertain. Patients with a clinical deficit that is disproportionately severe relative to the infarct volume may benefit from late thrombectomy. MethodsWe enrolled patients with occlusion of the intracranial internal carotid artery or proximal middle cerebral artery who had last been known to be well 6 to 24 hours earlier and who had a mismatch between the severity of the clinical deficit and the infarct volume, with mismatch criteria defined according to age (<80 years or ≥80 years). Patients were randomly assigned to thrombectomy plus standard care (the thrombectomy group) or to standard care alone (the control group). The coprimary end points were the mean score for disability on the utility-weighted modified Rankin scale (which ranges from 0 [death] to 10 [no symptoms or disability]) and the rate of functional independence (a score of 0, 1, or 2 on the modified Rankin scale, whic...

3,331 citations

Journal ArticleDOI
TL;DR: In patients with severe aortic stenosis who are at increased surgical risk, TAVR with a self-expanding transcatheter aorti-valve bioprosthesis was associated with a significantly higher rate of survival at 1 year than surgical aorticsvalve replacement.
Abstract: BACKGROUND We compared transcatheter aortic-valve replacement (TAVR), using a self-expanding transcatheter aortic-valve bioprosthesis, with surgical aortic-valve replacement in patients with severe aortic stenosis and an increased risk of death during surgery. METHODS We recruited patients with severe aortic stenosis who were at increased surgical risk as determined by the heart team at each study center. Risk assessment included the Society of Thoracic Surgeons Predictor Risk of Mortality estimate and consideration of other key risk factors. Eligible patients were randomly assigned in a 1:1 ratio to TAVR with the self-expanding transcatheter valve (TAVR group) or to surgical aortic-valve replacement (surgical group). The primary end point was the rate of death from any cause at 1 year, evaluated with the use of both noninferiority and superiority testing. RESULTS A total of 795 patients underwent randomization at 45 centers in the United States. In the as-treated analysis, the rate of death from any cause at 1 year was significantly lower in the TAVR group than in the surgical group (14.2% vs. 19.1%), with an absolute reduction in risk of 4.9 percentage points (upper boundary of the 95% confidence interval, −0.4; P<0.001 for noninferiority; P = 0.04 for superiority). The results were similar in the intention-to-treat analysis. In a hierarchical testing procedure, TAVR was noninferior with respect to echocardiographic indexes of valve stenosis, functional status, and quality of life. Exploratory analyses suggested a reduction in the rate of major adverse cardiovascular and cerebrovascular events and no increase in the risk of stroke. CONCLUSIONS In patients with severe aortic stenosis who are at increased surgical risk, TAVR with a self-expanding transcatheter aortic-valve bioprosthesis was associated with a significantly higher rate of survival at 1 year than surgical aortic-valve replacement. (Funded by Medtronic; U.S. CoreValve High Risk Study ClinicalTrials.gov number, NCT01240902.)

2,432 citations

Journal ArticleDOI
TL;DR: TAVR was a noninferior alternative to surgery in patients with severe aortic stenosis at intermediate surgical risk, with a different pattern of adverse events associated with each procedure.
Abstract: BackgroundAlthough transcatheter aortic-valve replacement (TAVR) is an accepted alternative to surgery in patients with severe aortic stenosis who are at high surgical risk, less is known about comparative outcomes among patients with aortic stenosis who are at intermediate surgical risk. MethodsWe evaluated the clinical outcomes in intermediate-risk patients with severe, symptomatic aortic stenosis in a randomized trial comparing TAVR (performed with the use of a self-expanding prosthesis) with surgical aortic-valve replacement. The primary end point was a composite of death from any cause or disabling stroke at 24 months in patients undergoing attempted aortic-valve replacement. We used Bayesian analytical methods (with a margin of 0.07) to evaluate the noninferiority of TAVR as compared with surgical valve replacement. ResultsA total of 1746 patients underwent randomization at 87 centers. Of these patients, 1660 underwent an attempted TAVR or surgical procedure. The mean (±SD) age of the patients was 7...

2,095 citations

Journal ArticleDOI
TL;DR: The trial showed similar safety outcomes and no significant difference in functional independence with endovascular therapy after intravenous t-PA, as compared with intravenoust-PA alone.
Abstract: BACKGROUND Endovascular therapy is increasingly used after the administration of intravenous tissue plasminogen activator (t-PA) for patients with moderate-to-severe acute ischemic stroke, but whether a combined approach is more effective than intravenous t-PA alone is uncertain. METHODS We randomly assigned eligible patients who had received intravenous t-PA within 3 hours after symptom onset to receive additional endovascular therapy or intravenous t-PA alone, in a 2:1 ratio. The primary outcome measure was a modified Rankin scale score of 2 or less (indicating functional independence) at 90 days (scores range from 0 to 6, with higher scores indicating greater disability). RESULTS The study was stopped early because of futility after 656 participants had undergone randomization (434 patients to endovascular therapy and 222 to intravenous t-PA alone). The proportion of participants with a modified Rankin score of 2 or less at 90 days did not differ significantly according to treatment (40.8% with endovascular therapy and 38.7% with intravenous t-PA; absolute adjusted difference, 1.5 percentage points; 95% confidence interval [CI], −6.1 to 9.1, with adjustment for the National Institutes of Health Stroke Scale [NIHSS] score [8–19, indicating moderately severe stroke, or ≥20, indicating severe stroke]), nor were there significant differences for the predefined subgroups of patients with an NIHSS score of 20 or higher (6.8 percentage points; 95% CI, −4.4 to 18.1) and those with a score of 19 or lower (−1.0 percentage point; 95% CI, −10.8 to 8.8). Findings in the endovascular-therapy and intravenous t-PA groups were similar for mortality at 90 days (19.1% and 21.6%, respectively; P = 0.52) and the proportion of patients with symptomatic intracerebral hemorrhage within 30 hours after initiation of t-PA (6.2% and 5.9%, respectively; P = 0.83). CONCLUSIONS The trial showed similar safety outcomes and no significant difference in functional independence with endovascular therapy after intravenous t-PA, as compared with intravenous t-PA alone. (Funded by the National Institutes of Health and others; ClinicalTrials.gov number, NCT00359424.)

1,702 citations

Journal ArticleDOI
01 Jul 2005-Stroke
TL;DR: A novel endovascular embolectomy device can significantly restore vascular patency during acute ischemic stroke within 8 hours of stroke symptom onset and provides an alternative intervention for patients who are otherwise ineligible for thrombolytics.
Abstract: Background and Purpose—The only Food and Drug Administration (FDA)-approved treatment for acute ischemic stroke is tissue plasminogen activator (tPA) given intravenously within 3 hours of symptom onset. An alternative strategy for opening intracranial vessels during stroke is mechanical embolectomy, especially for patients ineligible for intravenous tPA. Methods—We investigated the safety and efficacy of a novel embolectomy device (Merci Retriever) to open occluded intracranial large vessels within 8 hours of the onset of stroke symptoms in a prospective, nonrandomized, multicenter trial. All patients were ineligible for intravenous tPA. Primary outcomes were recanalization and safety, and secondary outcomes were neurological outcome at 90 days in recanalized versus nonrecanalized patients. Results—Recanalization was achieved in 46% (69/151) of patients on intention to treat analysis, and in 48% (68/141) of patients in whom the device was deployed. This rate is significantly higher than that expected using an historical control of 18% (P0.0001). Clinically significant procedural complications occurred in 10 of 141 (7.1%) patients. Symptomatic intracranial hemorrhages was observed in 11 of 141 (7.8%) patients. Good neurological outcomes (modified Rankin score 2) were more frequent at 90 days in patients with successful recanalization compared with patients with unsuccessful recanalization (46% versus 10%; relative risk [RR], 4.4; 95% CI, 2.1 to 9.3; P0.0001), and mortality was less (32% versus 54%; RR, 0.59; 95% CI, 0.39 to 0.89; P0.01). Conclusions—A novel endovascular embolectomy device can significantly restore vascular patency during acute ischemic stroke within 8 hours of stroke symptom onset and provides an alternative intervention for patients who are otherwise ineligible for thrombolytics. (Stroke. 2005;36:1432-1440.)

1,298 citations


Authors

Showing all 672 results

NameH-indexPapersCitations
Robert M. Califf1961561167961
Eric J. Topol1931373151025
David R. Holmes1611624114187
Stephen G. Ellis12765565073
Daniel B. Mark12457678385
E. Magnus Ohman12462268976
Spencer B. King7326623814
Kate E. Webster6127814905
Paul K. Maciejewski5416515005
Patrick G. Gallagher5228010279
Bernard G. Forget521738328
Emile G. Daoud451267508
Dean J. Kereiakes438910266
Barry S. George42798605
Harry R. Phillips411346945
Network Information
Related Institutions (5)
Kaiser Permanente
24.3K papers, 1.2M citations

86% related

Henry Ford Hospital
12.4K papers, 465.3K citations

85% related

Tufts Medical Center
14.6K papers, 775.8K citations

84% related

Rush University Medical Center
29K papers, 1.3M citations

84% related

Cleveland Clinic
79.3K papers, 3.4M citations

84% related

Performance
Metrics
No. of papers from the Institution in previous years
YearPapers
20223
202188
202060
201951
201844
201745