Institution
University of Ioannina
Education•Ioannina, Greece•
About: University of Ioannina is a education organization based out in Ioannina, Greece. It is known for research contribution in the topics: Population & Large Hadron Collider. The organization has 7654 authors who have published 20594 publications receiving 671560 citations. The organization is also known as: Panepistimio Ioanninon.
Papers published on a yearly basis
Papers
More filters
••
TL;DR: A significant difference was found within the ACL reconstructed group and between the reconstructed and the contralateral intact leg, suggesting ACL reconstruction may not restore tibial rotation even though anterior tibials translation has been reestablished.
Abstract: Recent in vitro research suggests that ACL reconstruction does not restore tibial rotation. This study investigated rotational knee joint stability in vivo during a combined descending and pivoting movement that applies a high rotational load to the knee joint. We studied 20 ACL reconstructed patients (bone–patellar tendon–bone graft) and 15 matched controls with a six-camera optoelectronic system performing the examined movement. In the control group the results showed no significant differences in the amount of tibial rotation between the two sides. No significant differences were also found between the contralateral intact leg of the ACL group and the healthy control. However, a significant difference was found within the ACL reconstructed group and between the reconstructed and the contralateral intact leg. Therefore ACL reconstruction may not restore tibial rotation even though anterior tibial translation has been reestablished.
226 citations
••
Vardan Khachatryan, Albert M. Sirunyan, Armen Tumasyan, Wolfgang Adam1 +2184 more•Institutions (150)
TL;DR: In this article, the W and Z boson production cross sections in pp collisions at 7 TeV are presented, based on 2.9 inverse picobarns of data recorded by the CMS detector at the LHC.
Abstract: Measurements of inclusive W and Z boson production cross sections in pp collisions at sqrt(s)=7 TeV are presented, based on 2.9 inverse picobarns of data recorded by the CMS detector at the LHC. The measurements, performed in the electron and muon decay channels, are combined to give sigma(pp to WX) times B(W to muon or electron + neutrino) = 9.95 \pm 0.07(stat.) \pm 0.28(syst.) \pm 1.09(lumi.) nb and sigma(pp to ZX) times B(Z to oppositely charged muon or electron pairs) = 0.931 \pm 0.026(stat.) \pm 0.023(syst.) \pm 0.102(lumi.) nb. Theoretical predictions, calculated at the next-to-next-to-leading order in QCD using recent parton distribution functions, are in agreement with the measured cross sections. Ratios of cross sections, which incur an experimental systematic uncertainty of less than 4%, are also reported.
225 citations
••
TL;DR: The results suggest that neutral CDs-PEG are the most promising for biological applications as they do not induce any abnormalities in cell morphology, intracellular trafficking, and cell cycle up to concentrations of 300 μg mL−1.
225 citations
••
Boston University1, Perimeter Institute for Theoretical Physics2, University of Waterloo3, Massachusetts Institute of Technology4, Joseph Fourier University5, University of California, Los Angeles6, Occidental College7, University of Pennsylvania8, University of Zaragoza9, University of Sheffield10, Brandeis University11, Harvard University12, Nagasaki Institute of Applied Science13, University of Edinburgh14, University of New Mexico15, University of Huelva16, University of Utah17, University of Nottingham18, Kyoto University19, Lawrence Berkeley National Laboratory20, Temple University21, University of Warwick22, New York University23, Nagoya University24, University of Tokyo25, Saga University26, University of Ioannina27
TL;DR: The case for a dark matter detector with directional sensitivity was presented at the 2009 CYGNUS workshop on directional dark matter detection, and contributions from theorists and experimental groups in the field as mentioned in this paper.
Abstract: We present the case for a dark matter detector with directional sensitivity. This document was developed at the 2009 CYGNUS workshop on directional dark matter detection, and contains contributions from theorists and experimental groups in the field. We describe the need for a dark matter detector with directional sensitivity; each directional dark matter experiment presents their project's status; and we close with a feasibility study for scaling up to a one ton directional detector, which would cost around $150M.
224 citations
••
TL;DR: In this article, a simple molecular approach to control the lipophilic/hydrophilic nature of photoluminescent carbon dots (CDs) based on pyrolysis of alkyl gallate precursors is presented.
223 citations
Authors
Showing all 7724 results
Name | H-index | Papers | Citations |
---|---|---|---|
John P. A. Ioannidis | 185 | 1311 | 193612 |
Kay-Tee Khaw | 174 | 1389 | 138782 |
Elio Riboli | 158 | 1136 | 110499 |
Mercouri G. Kanatzidis | 152 | 1854 | 113022 |
Dimitrios Trichopoulos | 135 | 818 | 84992 |
Gyorgy Vesztergombi | 133 | 1444 | 94821 |
Niki Saoulidou | 132 | 1065 | 81154 |
Apostolos Panagiotou | 132 | 1370 | 88647 |
Ioannis Evangelou | 131 | 1225 | 82178 |
Ioannis Papadopoulos | 129 | 1201 | 85576 |
Nikolaos Manthos | 129 | 1256 | 81865 |
Panagiotis Kokkas | 128 | 1234 | 81051 |
Costas Foudas | 128 | 1112 | 83048 |
Zoltan Szillasi | 128 | 1214 | 84392 |
Matthias Schröder | 126 | 1421 | 82990 |