scispace - formally typeset
Search or ask a question

Showing papers in "arXiv: Instrumentation and Detectors in 1998"


Journal ArticleDOI
TL;DR: In this article, the performance of hybrid GaAs pixel detectors as X-ray imaging sensors was investigated at room temperature and the signal to noise ratio (SNR) was also determined.
Abstract: The performance of hybrid GaAs pixel detectors as X-ray imaging sensors were investigated at room temperature. These hybrids consist of 300 mu-m thick GaAs pixel detectors, flip-chip bonded to a CMOS Single Photon Counting Chip (PCC). This chip consists of a matrix of 64 x 64 identical square pixels (170 mu-m x 170 mu-m) and covers a total area of 1.2 cm**2. The electronics in each cell comprises a preamplifier, a discriminator with a 3-bit threshold adjust and a 15-bit counter. The detector is realized by an array of Schottky diodes processed on semi-insulating LEC-GaAs bulk material. An IV-charcteristic and a detector bias voltage scan showed that the detector can be operated with voltages around 200 V. Images of various objects were taken by using a standard X-ray tube for dental diagnostics. The signal to noise ratio (SNR) was also determined. The applications of these imaging systems range from medical applications like digital mammography or dental X-ray diagnostics to non destructive material testing (NDT). Because of the separation of detector and readout chip, different materials can be investigated and compared.

23 citations


Journal ArticleDOI
TL;DR: In this article, a photomultiplier setup for precise relative CsI(Tl) crystal light yield and uniformity measurements is described, which is used for wrapping material studies to optimize the uniformity and the yield of the light output of 36 cm long crystals.
Abstract: A photomultiplier setup for precise relative CsI(Tl) crystal light yield and uniformity measurements is described. It is used for wrapping material studies to optimize the uniformity and the yield of the light output of 36 cm long crystals. The uniformity is an important property in high energy photon calorimetry. Results of an optimization of photodiode coupling to crystals, the influence of temperature and radiation damage to light and photoelectron yield are also presented.

15 citations


Journal ArticleDOI
TL;DR: In this paper, the general purpose spherical nonmagnetic detector (SND) is now taking data at VEPP-2M $e^+e^-$ collider in BINP (Novosibirsk) in the centre of mass energy range of $0.2 ÷1.4$ GeV.
Abstract: The general purpose spherical nonmagnetic detector (SND) is now taking data at VEPP-2M $e^+e^-$ collider in BINP (Novosibirsk) in the centre of mass energy range of $0.2 ÷1.4$ GeV. The energy calibration of the NaI(Tl) calorimeter of the SND detector with cosmic muons is described. Using this method, the energy resolution of $5.5 % (\sigma)$ for 500 MeV photons was achieved.

11 citations


Posted Content
TL;DR: This note explains, through the use of diagrams, how CRISTAL can be established for detector production and used as the information source for analyses, such as calibration and slow controls, carried out by physicists.
Abstract: The CRISTAL (Cooperating Repositories and an Information System for Tracking Assembly Lifecycles) project is delivering a software system to facilitate the management of the engineering data collected at each stage of production of CMS. CRISTAL captures all the physical characteristics of CMS components as each sub-detector is tested and assembled. These data are retained for later use in areas such as detector slow control, calibration and maintenance. CRISTAL must, therefore, support different views onto its data dependent on the role of the user. These data viewpoints are investigated in this paper. In the recent past two CMS Notes have been written about CRISTAL. The first note, CMS 1996/003, detailed the requirements for CRISTAL, its relationship to other CMS software, its objectives and reviewed the technology on which it would be based. CMS 1997/104 explained some important design concepts on which CRISTAL is and showed how CRISTAL integrated the domains of product data man- agement and workflow management. This note explains, through the use of diagrams, how CRISTAL can be established for detector production and used as the information source for analyses, such as calibration and slow controls, carried out by physicists. The reader should consult the earlier CMS Notes and conference papers for technical detail on CRISTAL - this note concentrates on issues surrounding the practical use of the CRISTAL software.

9 citations


Journal ArticleDOI
TL;DR: In this article, a general solution to the positive ion feedback problem in Hybrid Photon Detectors (HPD), photo multipliers (PM) and other similar detectors was found in the insertion of a permanent electrostatic potential barrier which prevents drift of positive ions from the anode, or the first dynode, towards the photocathode.
Abstract: A general solution to the positive ion feedback problem in Hybrid Photon Detectors (HPD), photo multipliers (PM) and other similar detectors was found in the insertion of a permanent electrostatic potential barrier which prevents drift of positive ions from the anode, or the first dynode, towards the photocathode. In this paper we present the method as applied to the Intevac HPD.

8 citations


Journal ArticleDOI
TL;DR: In this paper, the three layer NaI(Tl) spherical calorimeter of the SND detector using electron-posite scattering events is described, achieving an energy resolution of 5 % (FWHM/2.36) for 500 MeV photons.
Abstract: Calibration of the three layer NaI(Tl) spherical calorimeter of the SND detector using electron -- positron scattering events is described. Energy resolution of $5 % (FWHM/2.36)$ for 500 MeV photons was achieved.

7 citations


Journal ArticleDOI
TL;DR: In this article, the authors proposed a method for in-situ measurement of the length of kilometer size Fabry-Perot cavities in laser gravitational wave detectors based on thevernier, which occurs naturally when the laser incident on the cavity has a sideband.
Abstract: We propose a method for in-situ measurement of the length of kilometer size Fabry-Perot cavities in laser gravitational wave detectors. The method is based on the vernier, which occurs naturally when the laser incident on the cavity has a sideband. By changing the length of the cavity over several wavelengths we obtain a set of carrier resonances alternating with sideband resonances. From the measurement of the separation between the carrier and a sideband resonance we determine the length of the cavity. We apply the technique to the measurement of the length of a Fabry-Perot cavity in the Caltech 40m Interferometer and discuss the accuracy of the technique.

6 citations


Posted Content
TL;DR: The inner tracker system of the HERA-B experiment at DESY consists of 184 Microstrip Gas Chambers (MSGC) with a total number of 147 456 electronic read out channels as discussed by the authors.
Abstract: The Inner Tracker System of the HERA-B experiment at DESY consists of 184 Microstrip Gas Chambers (MSGC) with a total number of 147 456 electronic read out channels. The detectors have to cope with particle fluxes up to 25 kHz/mm**2 and to tolerate radiation doses of 1 Mrad per year. During the development of these chambers it was found that conventional MSGC, operated in intenses hadronic fluxes, are rapidly destroyed due to induced discharges. The introduction of a Gas Electron Multiplier (GEM) as pre-amplification structure offers the possibility to build robust and reliable detectors allowing for ample gain reserve in the hostile environment of HERA-B.

4 citations


Posted Content
TL;DR: An introductory review of subatomic-particle detection techniques can be found in this article, which is suitable for the beginning student of high energy physics or professionals from other fields who may desire familiarity with subatomic particle detection techniques.
Abstract: An introductory review, suitable for the beginning student of high-energy physics or professionals from other fields who may desire familiarity with subatomic-particle detection techniques. Subatomic-particle fundamentals and the basics of particle interactions with matter are summarized, after which we review particle detectors. We conclude with three examples that illustrate the variety of subatomic-particle spectrometers and exemplify the combined use of several detection techniques to characterize interaction events more-or-less completely.

4 citations


Posted Content
TL;DR: In this article, a photoelectron focussing method was introduced to achieve the highest possible surface coverage in a RICH detector, which is efficient to the periphery of the photocathode.
Abstract: New developments in HPD design are presented, triggered by applications in high energy physics and astrophysics. The presented HPD designs are based on three innovations. (i) In order to achieve the highest possible surface coverage in a RICH detector, we introduced a photoelectron focussing method which is efficient to the periphery of the photocathode. (ii) To prevent positive ion feedback in HPDs, we introduced a permanent potential barrier in front of the anode. (iii) To replace a transmittive by a reflective photocathode, we arrived at a conceptually new HPD design with surprisingly good imaging characteristics, high quantum efficiency and low cost.

4 citations


Posted Content
TL;DR: In this article, the Compton back scattering of laser photons on high energy electrons is evaluated by Monte-Carlo simulations, and the results indicate a reasonability for construction of gamma-polarimeters on existing and planned facilities for the on-line measurement of the final photon beam polarization.
Abstract: Polarization characteristics of the gamma beam obtained by the Compton back scattering of laser photons on high energy electrons are evaluated by Monte-Carlo simulations. It is assumed that outgoing photons are tagged; the energy dispersion of the tagging photons and emittance of the initial electrons are taken into account. Dependence of the final photon polarization parameters on measured photon energy is obtained. It is shown that polarization of final photons is decreasing with change for the worth of the tagging energy resolution. Calculations have been applied for the storage ring SIBERIA-2 at Kurchatov Institute. The obtained results indicate a reasonability for construction of gamma-polarimeters on existing and planned facilities for the on-line measurement of the final photon beam polarization.

Journal ArticleDOI
TL;DR: In this article, an electronic system developed for the SpaCal lead/scintillating-fibre calorimeters of the H1 detector in operation at the HERA ep collider is described and the performance achieved during H1 data-taking is presented.
Abstract: The electronic system developed for the SpaCal lead/scintillating-fibre calorimeters of the H1 detector in operation at the HERA ep collider is described in detail and the performance achieved during H1 data-taking is presented. The 10 MHz bunch crossing rate of HERA puts severe constraints on the requirements of the electronics. The energy and time readout are performed respectively with a 14-bit dynamic range and with a resolution of about 0.4 ns. The trigger branch consists of a nanosecond-resolution calorimetric time-of-flight for background rejection and an electron trigger based on analog `sliding windows'. The on-line background rejection currently achieved is o(10**6). The electron trigger allows a low energy trigger threshold to be set at about 0.50 +/- 0.08 (RMS) GeV with an efficiency >99.9%. The energy and time performance of the readout and trigger electronics is based on a newly-developed low noise (sigma_noise ca. 0.4 MeV) wideband (f < 200 MHz) preamplifier located at the output of the photomultipliers which are used for the fibre light readout in the ca. 1 Tesla magnetic field of H1.

Journal ArticleDOI
TL;DR: In this paper, a fiber detector concept has been realized allowing to register particles within less than 100 nsec with a space point precision of about 0.1 mm at low occupancy.
Abstract: A fiber detector concept has been realized allowing to registrate particles within less than 100 nsec with a space point precision of about 0.1 mm at low occupancy. Three full size prototypes have been build by different producers and tested at a 3 GeV electron beam at DESY. After 3 m of light guides 8-10 photoelectrons were registrated by multichannel photomultipliers providing an efficiency of more than 99%. Using all available data a resolution of 0.086 mm was measured.

Posted Content
TL;DR: In this article, a parallel geometry gaseous detector constituted by a thin (06 mm) amplifying gap preceded by a drift region is described, delimited by a metal plate and by a wire mesh.
Abstract: In this work we describe a parallel geometry gaseous detector constituted by a thin (06 mm) amplifying gap preceded by a drift region The gap is delimited by a metal plate and by a wire mesh The detector can count up to a rate of 10^7 Hz/mm2 at gain 1000 and retains at lower counting rates the high gains (close to 10^6) that are typical of parallel geometry detectors Additionally it was found that in the thin amplifying gap the discharges seem to be self-quenched and that full sparks do not develop This fact, together with the robustness of the electrode materials, makes this an extremely resilient high-rate detector

Posted Content
TL;DR: This paper outlines how viewpoints can be populated with data extracted from the construction database, for a set of detector elements relevant for analysis.
Abstract: CMS ECAL physicists must be able to extract physics characteristics from the ECAL construction database for the calibration of sets of detector components. Other applications, such as geometry for simulation and physics event reconstruction, will also need to extract data from the construction database. In each case, application software needs to query the construction database and to extract data that satisfies a particular view. These viewpoints are defined for a specific purpose (e.g. simulation, slow control, calibration) and data must be extracted into the viewpoint for a set of defined detector components (e.g. readout channels) called physics elements. The ECAL construction database follows an object-oriented design to maximise flexibility and reusability. An meta-modelling approach has been taken in its design, which promotes self-description and a degree of data independence. A query facility is being provided to allow navigation around so-called meta-objects in the construction database, facilitating the extraction of physics data into a particular viewpoint. This paper outlines how viewpoints can be populated with data extracted from the construction database, for a set of detector elements relevant for analysis.

Proceedings ArticleDOI
TL;DR: Using scintillator tile technology several square meters of plastic scintillation are read out by only two photomultiplier with a time precision of about 1.5 nsec as mentioned in this paper.
Abstract: Using scintillator tile technology several square meters of plastic scintillator are read out by only two photomultiplier with a time precision of about 1.5 nsec. Two examples are discussed to build a detector based on this technology to search for cosmic muons and neutrinos.

Journal ArticleDOI
TL;DR: In this article, a method was presented of profiling the magnetic field, with a zero vector of magnetic flux density and strong gradient G, enabling conditions for the Stern-Gerlach spectroscopy to be accomplished in condensed matter.
Abstract: A method was presented of profiling the magnetic field, with a zero vector of magnetic flux density $B_{r}$ and strong gradient G, enabling conditions for the Stern-Gerlach spectroscopy to be accomplished in condensed matter (the method has been called magnetic field gradient spectroscopy - MGRS), as well the previously proposed magnetic resonance spectroscopy for selected energy states (SSMRS). Magnetic field distribution in a model electromagnet were shown when condition $B_{r}= 0$ for resultant magnetic field was satisfied within the sample

Journal ArticleDOI
D. Ferenc1
TL;DR: In this paper, a hybrid photon detector (HPD) was developed for integration in large area Cherenkov detectors for high energy physics and astrophysics applications, including MAGIC, LHCb and AQUA-RICH.
Abstract: Imaging Hybrid Photon Detectors (HPD) have been developed for integration in large area Cherenkov detectors for high energy physics and astrophysics. The presented designs - developed particularly for the experiments MAGIC, LHCb and AQUA-RICH - comprise very good imaging properties, protection against positive ion feedback and(or) minimum dead area. The underlying innovations are discussed in some detail.

Posted Content
TL;DR: In this paper, the apparatus description for control of the time parameters of photomultipliers with high time resolution is described for generation of ultrashort light flashes have been used sonoluminescence effect -- emission of the light flashes which is appearing at the stressed interior of collapsing air microbubble by sound wave in water.
Abstract: The apparatus description for control of the time parameters of photomultipliers with high time resolution is described. For generation of ultrashort light flashes have been used sonoluminescence effect -- emission of the light flashes which is appearing at the stressed interior of collapsing air microbubble by sound wave in water.