Showing papers in "arXiv: Medical Physics in 2016"


Journal ArticleDOI
TL;DR: In this paper, a low-rank inverse problem was proposed to reduce the computational burden by reducing the number of Fourier transformations and the low rank approximation improved the conditioning of the problem, which was further improved by extending the low-ranking inverse problem to an augmented Lagrangian that is solved by the alternating direction method of multipliers (ADMM).
Abstract: Purpose The proposed reconstruction framework addresses the reconstruction accuracy, noise propagation and computation time for Magnetic Resonance Fingerprinting (MRF). Methods Based on a singular value decomposition (SVD) of the signal evolution, MRF is formulated as a low rank inverse problem in which one image is reconstructed for each singular value under consideration. This low rank approximation of the signal evolution reduces the computational burden by reducing the number of Fourier transformations. Also, the low rank approximation improves the conditioning of the problem, which is further improved by extending the low rank inverse problem to an augmented Lagrangian that is solved by the alternating direction method of multipliers (ADMM). The root mean square error and the noise propagation are analyzed in simulations. For verification, in vivo examples are provided. Results The proposed low rank ADMM approach shows a reduced root mean square error compared to the original fingerprinting reconstruction, to a low rank approximation alone and to an ADMM approach without a low rank approximation. Incorporating sensitivity encoding allows for further artifact reduction. Conclusion The proposed reconstruction provides robust convergence, reduced computational burden and improved image quality compared to other MRF reconstruction approaches evaluated in this study.

124 citations


Journal ArticleDOI
TL;DR: In this paper, an atlas-based approach is proposed to learn a dose prediction model for each patient in a training database, and then learns to match novel patients to the most relevant atlases.
Abstract: Recent works in automated radiotherapy treatment planning have used machine learning based on historical treatment plans to infer the spatial dose distribution for a novel patient directly from the planning image. We present an atlas-based approach which learns a dose prediction model for each patient (atlas) in a training database, and then learns to match novel patients to the most relevant atlases. The method creates a spatial dose objective, which specifies the desired dose-per-voxel, and therefore replaces any requirement for specifying dose-volume objectives for conveying the goals of treatment planning. A probabilistic dose distribution is inferred from the most relevant atlases, and is scalarized using a conditional random field to determine the most likely spatial distribution of dose to yield a specific dose prior (histogram) for relevant regions of interest. Voxel-based dose mimicking then converts the predicted dose distribution to a deliverable treatment plan dose distribution. In this study, we investigated automated planning for right-sided oropharaynx head and neck patients treated with IMRT and VMAT. We compare four versions of our dose prediction pipeline using a database of 54 training and 12 independent testing patients. Our preliminary results are promising; automated planning achieved a higher number of dose evaluation criteria in 7 patients and an equal number in 4 patients compared with clinical. Overall, the relative number of criteria achieved was higher for automated planning versus clinical (17 vs 8) and automated planning demonstrated increased sparing for organs at risk (52 vs 44) and better target coverage/uniformity (41 vs 31).

103 citations


Posted Content
TL;DR: It is demonstrated how combining data from multiple sensors within such an integrated wearable device improves both the accuracy of measurements and the ability to deal with artifacts in real-world scenarios.
Abstract: Future health systems require the means to assess and track the neural and physiological function of a user over long periods of time and in the community. Human body responses are manifested through multiple modalities, such as the mechanical, electrical and chemical; yet current physiological monitors (actigraphy, heart rate) largely lack in both the desired cross-modal and non-stigmatizing aspects. We address these challenges through an inconspicuous and comfortable earpiece, equipped with miniature multimodal sensors, which benefits from the relatively stable position of the ear canal with respect to vital organs to robustly measure the brain, cardiac and respiratory functions. Comprehensive experiments validate each modality within the proposed earpiece, while its potential in health monitoring is illustrated through case studies. We further demonstrate how combining data from multiple sensors within such an integrated wearable device improves both the accuracy of measurements and the ability to deal with artifacts in real-life scenarios.

96 citations


Posted Content
TL;DR: A data-driven learning-based method is proposed based on a deep convolutional neural network that provides a simple and efficient approach for improving image quality of the reconstruction results from limited projection data.
Abstract: Limited angle problem is a challenging issue in x-ray computed tomography (CT) field. Iterative reconstruction methods that utilize the additional prior can suppress artifacts and improve image quality, but unfortunately require increased computation time. An interesting way is to restrain the artifacts in the images reconstructed from the practical filtered back projection (FBP) method. Frikel and Quinto have proved that the streak artifacts in FBP results could be characterized. It indicates that the artifacts created by FBP method have specific and similar characteristics in a stationary limited-angle scanning configuration. Based on this understanding, this work aims at developing a method to extract and suppress specific artifacts of FBP reconstructions for limited-angle tomography. A data-driven learning-based method is proposed based on a deep convolutional neural network. An end-to-end mapping between the FBP and artifact-free images is learned and the implicit features involving artifacts will be extracted and suppressed via nonlinear mapping. The qualitative and quantitative evaluations of experimental results indicate that the proposed method show a stable and prospective performance on artifacts reduction and detail recovery for limited angle tomography. The presented strategy provides a simple and efficient approach for improving image quality of the reconstruction results from limited projection data.

93 citations


Posted Content
TL;DR: A new hybrid metasurface structure, comprising a two-dimensional metamaterial surface and a very high permittivity dielectric substrate, that has been designed to enhance the local performance of an ultra-high field MRI scanner.
Abstract: Developments in metamaterials and related structures such as metasurfaces have opened up new possibilities in designing materials and devices with unique properties. The main progress related to electromagnetic waves applications was done in optical and microwave spectra. Here we report about a new hybrid metasurface structure, comprising a two-dimensional metamaterial surface and a very high permittivity dielectric substrate that was designed to enhance the performance of an ultra-high field MRI scanner. This new flexible and compact resonant structure is the first one which can be integrated into a multi-element close-fitting receive coil array used for all clinical MRI. We successfully demonstrated the operation of the metasurface in acquiring vivo human brain images and spectra with enhanced local sensitivity on a commercial 7 Tesla system. These experimental findings prove the feasibility of real clinical applications of metasurfaces in MRI.

61 citations


Journal ArticleDOI
TL;DR: In this article, indirect plasma treatment using cold atmospheric plasma discharged in DI water using three gases as carriers (argon, helium and nitrogen) was applied to human breast cancer cell line (MDA-MB-231).
Abstract: Cold atmospheric plasma (CAP) has been emerged as a novel technology for cancer treatment. CAP can directly treat cells and tissue but such direct application is limited to skin or can be invoked as a supplement during open surgery. In this study we report indirect plasma treatment using CAP discharged in DI water using three gases as carriers (argon, helium and nitrogen). Plasma stimulated water was applied to human breast cancer cell line (MDA-MB-231). MTT assay tests showed that using argon plasma had the strongest effect on inducing apoptosis in cultured human breast cancer cells. This result is attributed to the elevated production of the reactive oxygen species and reactive nitrogen species in water in the case of argon plasma.

55 citations


Journal ArticleDOI
TL;DR: In this paper, the authors present an approach based on the factorization of the stopping power ratio into the relative electron density and the relative stopping number, which can be used to incorporate proper mixing behavior on several structural levels.
Abstract: The use of dual-energy CT (DECT) potentially decreases range uncertainties in proton and ion therapy treatment planning via determination of the involved physical target quantities. For eventual clinical application, the correct treatment of tissue mixtures and heterogeneities is an essential feature, as they naturally occur within a patient's CT. Here, we present how existing methods for DECT-based ion-range prediction can be modified in order to incorporate proper mixing behavior on several structural levels. Our approach is based on the factorization of the stopping-power ratio into the relative electron density and the relative stopping number. The latter is confined for tissue between about 0.95 and 1.02 at a therapeutic beam energy of 200 MeV/u and depends on the I-value. We show that convenient mixing and averaging properties arise by relating the relative stopping number to the relative cross section obtained by DECT. From this, a maximum uncertainty of the stopping-power ratio prediction below 1% is suggested for arbitrary mixtures of human body tissues.

50 citations


Journal ArticleDOI
TL;DR: In this article, a method to map subcellular magnetic fields in mammalian cells and tissues using nitrogen vacancy diamond magnetometry and connect these maps to voxel-scale MRI contrast is described.
Abstract: Magnetic resonance imaging (MRI) is a widely used biomedical imaging modality that derives much of its contrast from microscale magnetic field gradients in biological tissues. However, the connection between these sub-voxel field patterns and MRI contrast has not been studied experimentally. Here, we describe a new method to map subcellular magnetic fields in mammalian cells and tissues using nitrogen vacancy diamond magnetometry and connect these maps to voxel-scale MRI contrast, providing insights for in vivo imaging and contrast agent design.

50 citations


Posted Content
TL;DR: Visual and quantitative evaluation demonstrates a competing performance of the proposed noise reduction method via deep neural network without accessing original projection data for low-dose CT via deep convolutional neural network.
Abstract: To reduce the potential radiation risk, low-dose CT has attracted much attention. However, simply lowering the radiation dose will lead to significant deterioration of the image quality. In this paper, we propose a noise reduction method for low-dose CT via deep neural network without accessing original projection data. A deep convolutional neural network is trained to transform low-dose CT images towards normal-dose CT images, patch by patch. Visual and quantitative evaluation demonstrates a competing performance of the proposed method.

48 citations


Journal ArticleDOI
TL;DR: An image-domain material decomposition algorithm for dual-energy CT (DECT) is developed by incorporating an edge-preserving filter into the Local HighlY constrained backPRojection reconstruction (HYPR-LR) framework, which significantly reduces the DECTmaterial decomposition noise while preserving quantitative measurements and high-frequency edge information.
Abstract: Increased noise is a general concern for dual-energy material decomposition. Here, we develop an image-domain material decomposition algorithm for dual-energy CT (DECT) by incorporating an edge-preserving filter into the Local HighlY constrained backPRojection Reconstruction (HYPR-LR) framework. With effective use of the non-local mean, the proposed algorithm, which is referred to as HYPR-NLM, reduces the noise in dual energy decomposition while preserving the accuracy of quantitative measurement and spatial resolution of the material-specific dual energy images. We demonstrate the noise reduction and resolution preservation of the algorithm with iodine concentrate numerical phantom by comparing the HYPR-NLM algorithm to the direct matrix inversion, HYPR-LR and iterative image-domain material decomposition (Iter-DECT). We also show the superior performance of the HYPR-NLM over the existing methods by using two sets of cardiac perfusing imaging data. The reference drawn from the comparison study includes: (1) HYPR-NLM significantly reduces the DECT material decomposition noise while preserving quantitative measurements and high-frequency edge information, and (2) HYPR-NLM is robust with respect to parameter selection.

39 citations


Journal ArticleDOI
TL;DR: In this article, two coupled lumped-parameter models (systemic and cerebrovascular circulations, respectively) were used to simulate sinus rhythm (SR) and atrial fibrillation (AF).
Abstract: Atrial fibrillation (AF) is associated with an increased risk of dementia and cognitive decline, independent of strokes. Several mechanisms have been proposed to explain this association, but altered cerebral blood flow dynamics during AF has been poorly investigated: in particular, it is unknown how AF influences hemodynamic parameters of the distal cerebral circulation, at the arteriolar and capillary level. Two coupled lumped-parameter models (systemic and cerebrovascular circulations, respectively) were here used to simulate sinus rhythm (SR) and AF. For each simulation 5000 cardiac cycles were analyzed and cerebral hemodynamic parameters were calculated. With respect to SR, AF triggered a higher variability of the cerebral hemodynamic variables which increases proceeding towards the distal circulation, reaching the maximum extent at the arteriolar and capillary levels. This variability led to critical cerebral hemodynamic events of excessive pressure or reduced blood flow: 303 hypoperfusions occurred at the arteriolar level, while 387 hypertensive events occurred at the capillary level during AF. By contrast, neither hypoperfusions nor hypertensive events occurred during SR. Thus, the impact of AF per se on cerebral hemodynamics candidates as a relevant mechanism into the genesis of AF-related cognitive impairment/dementia.

Journal ArticleDOI
TL;DR: In this paper, a generic rigorous Bayesian formalism is introduced to predict the most likely path of any ion crossing a medium between two detection points, based on a combination of the particle scattering in the material and measurements of its initial and final position, direction and energy.
Abstract: In this work, a generic rigorous Bayesian formalism is introduced to predict the most likely path of any ion crossing a medium between two detection points. The path is predicted based on a combination of the particle scattering in the material and measurements of its initial and final position, direction and energy. The path estimate's precision is compared to the Monte Carlo simulated path. Every ion from hydrogen to carbon is simulated in two scenarios to estimate the accuracy achievable: one where the range is fixed and one where the initial velocity is fixed. In the scenario where the range is kept constant, the maximal root-mean-square error between the estimated path and the Monte Carlo path drops significantly between the proton path estimate (0.50 mm) and the helium path estimate (0.18 mm), but less so up to the carbon path estimate (0.09 mm). In the scenario where the initial velocity is kept constant, helium have systematically the minimal root-mean-square error throughout the path. As a result, helium is found to be the optimal particle for ion imaging.

Posted Content
TL;DR: The ‘White Matter Modeling Challenge’ aimed to compare a range of different kinds of models in their ability to explain a large range of measurable in vivo DW human brain data and found that signal models do not necessarily outperform tissue models; in fact, of those tested, tissue models rank highest on average.
Abstract: A large number of mathematical models have been proposed to describe the measured signal in diffusion-weighted (DW) magnetic resonance imaging (MRI) and infer properties about the white matter microstructure. However, a head-to-head comparison of DW-MRI models is critically missing in the field. To address this deficiency, we organized the "White Matter Modeling Challenge" during the International Symposium on Biomedical Imaging (ISBI) 2015 conference. This competition aimed at identifying the DW-MRI models that best predict unseen DW data. in vivo DW-MRI data was acquired on the Connectom scanner at the A.A.Martinos Center (Massachusetts General Hospital) using gradients strength of up to 300 mT/m and a broad set of diffusion times. We focused on assessing the DW signal prediction in two regions: the genu in the corpus callosum, where the fibres are relatively straight and parallel, and the fornix, where the configuration of fibres is more complex. The challenge participants had access to three-quarters of the whole dataset, and their models were ranked on their ability to predict the remaining unseen quarter of data. In this paper we provide both an overview and a more in-depth description of each evaluated model, report the challenge results, and infer trends about the model characteristics that were associated with high model ranking. This work provides a much needed benchmark for DW-MRI models. The acquired data and model details for signal prediction evaluation are provided online to encourage a larger scale assessment of diffusion models in the future.

Journal ArticleDOI
TL;DR: The yields of prompt photons produced by the interaction of helium, carbon and oxygen ion beams with a poly-methyl methacrylate (PMMA) beam stopping target are reported on, demonstrating the feasibility of a prompt-γ-based monitoring technique for PT treatments using helium,carbon and oxygen Ion beams.
Abstract: Charged particle beams are used in Particle Therapy (PT) to treat oncological patients due to their selective dose deposition in tissues and to their high biological effect in killing cancer cells with respect to photons and electrons used in conventional radiotherapy. Nowadays, protons and carbon ions are used in PT clinical routine but, recently, the interest on the potential application of helium and oxygen beams is growing due to their reduced multiple scattering inside the body and increased linear energy transfer, relative biological effectiveness and oxygen enhancement ratio. The precision of PT demands for online dose monitoring techniques, crucial to improve the quality assurance of treatments. The beam range confined in the irradiated target can be monitored thanks to the neutral or charged secondary radiation emitted by the interactions of hadron beams with matter. Prompt photons are produced by nuclear de-excitation processes and, at present, different dose monitoring and beam range verification techniques based on the prompt {\gamma} detection have been proposed. It is hence of importance to perform the {\gamma} yield measurement in therapeutical-like conditions. In this paper we report the yields of prompt photons produced by the interaction of helium, carbon and oxygen ion beams with a PMMA target. The measurements were performed at the Heidelberg Ion-beam Therapy center (HIT) with beams of different energies. A LYSO scintillator has been used as photon detector. The obtained {\gamma} yields for $^{12}$C ion beams are compared with results from literature, while no other results from $^{4}$He and $^{16}$O beams have been published yet. A discussion on the expected resolution of a slit camera detector is presented, demonstrating the feasibility of a prompt-{\gamma} based monitoring technique for PT treatments using helium, carbon and oxygen ion beams.

Posted Content
TL;DR: The aim of the Magnetic Particle Imaging Data Format (MDF) is to provide a coherent way of exchanging MPI data acquired with different MPI scanners worldwide.
Abstract: Magnetic particle imaging (MPI) is a tomographic method to determine the spatio-temporal distribution of magnetic nanoparticles. In this document, a file format for the standardized storage of MPI and magnetic particle spectroscopy (MPS) data is introduced. The aim of the Magnetic Particle Imaging Data Format (MDF) is to provide a coherent way of exchanging MPI and MPS data acquired with different devices worldwide. The focus of the MDF is on sequence parameters, measurement data, calibration data, and reconstruction data. The format is based on the hierarchical document format in version 5 (HDF5). This document discusses the MDF version 2.1.0, which is not backward compatible with version 1.x.y.

Journal ArticleDOI
TL;DR: In this paper, the authors present continuous-wave magneto-acoustic imaging techniques, which improve SNR and/or reduce the required peak-to-average excitation power ratio to make further integration and larger fields of view feasible.
Abstract: Magneto-acoustic tomography combines near-field radio-frequency (RF) and ultrasound with the aim of creating a safe, high resolution, high contrast hybrid imaging technique. We present continuous-wave magneto-acoustic imaging techniques, which improve SNR and/or reduce the required peak-to-average excitation power ratio, to make further integration and larger fields of view feasible. This method relies on the coherency between RF excitation and the resulting ultrasound generated through Lorentz force interactions, which was confirmed by our previous work. We provide detailed methodology, clarify the details of experiments, and explain how the presence of magneto-acoustic phenomenon was verified. An example magneto-acoustic B-scan image is acquired in order to illustrate the capability of magneto-acoustic tomography in highlighting boundaries where electrical conductivity alters, such as between different tissues.

Posted Content
TL;DR: In this paper, the speed of an elastic motion travelling radially on the skin of canine cadavers was measured with a commercial device called the Reviscometer, and the orientation of the fastest wave was found to correlate with the position of the elongated wound (P < 0.001, R^2 = 74%).
Abstract: Background: Since their discovery by Karl Langer in the 19th Century, Skin Tension Lines (STLs) have been used by surgeons to decide the location and orientation of an incision. Although these lines are patient-specific, most surgeons rely on generic maps to determine their orientation. Beyond the imprecise pinch test, there remains no accepted method for determining STLs in vivo. Methods: (i) The speed of an elastic motion travelling radially on the skin of canine cadavers was measured with a commercial device called the Reviscometer. (ii) Similar to the original experiments conducted by Karl Langer, circular excisions were made on the skin and the geometric changes to the resulting wounds and excised samples were used to determine the orientation of STLs. Results: A marked anisotropy in the speed of the elastic wave travelling radially was observed. The orientation of the fastest wave was found to correlate with the orientation of the elongated wound (P<0.001, R^2 = 74%). Similarly, the orientation of fastest wave was the same for both in vivo and excised isolated samples, indicating that the STLs have a structural basis. Resulting wounds expanded by an average area of 9% (+16% along STL and -10% across) while excised skin shrunk by an average area of 33% (23% along STL and 10% across). Conclusion: Elastic surface wave propagation has been validated experimentally as a robust method for determining the orientation of STLs non-destructively and non-invasively. This study has implications for the identification of STLs and for the prediction of skin tension levels, both important factors in both human and veterinary reconstructive surgery.

Journal ArticleDOI
TL;DR: In this article, a multi-patient atlas-based dose prediction approach was proposed to predict the dose-per-voxel for a novel patient directly from the computed tomography (CT) planning scan without the requirement of specifying any objectives.
Abstract: Automating the radiotherapy treatment planning process is a technically challenging problem. The majority of automated approaches have focused on customizing and inferring dose volume objectives to used in plan optimization. In this work we outline a multi-patient atlas-based dose prediction approach that learns to predict the dose-per-voxel for a novel patient directly from the computed tomography (CT) planning scan without the requirement of specifying any objectives. Our method learns to automatically select the most effective atlases for a novel patient, and then map the dose from those atlases onto the novel patient. We extend our previous work to include a conditional random field for the optimization of a joint distribution prior that matches the complementary goals of an accurately spatially distributed dose distribution while still adhering to the desired dose volume histograms. The resulting distribution can then be used for inverse-planning with a new spatial dose objective, or to create typical dose volume objectives for the canonical optimization pipeline. We investigated six treatment sites (633 patients for training and 113 patients for testing) and evaluated the mean absolute difference (MAD) in all DVHs for the clinical and predicted dose distribution. The results on average are favorable in comparison to our previous approach (1.91 vs 2.57). Comparing our method with and without atlas-selection further validates that atlas-selection improved dose prediction on average in Whole Breast (0.64 vs 1.59), Prostate (2.13 vs 4.07), and Rectum (1.46 vs 3.29) while it is less important in Breast Cavity (0.79 vs 0.92) and Lung (1.33 vs 1.27) for which there is high conformity and minimal dose shaping. In CNS Brain, atlas-selection has the potential to be impactful (3.65 vs 5.09), but selecting the ideal atlas is the most challenging.

Journal ArticleDOI
TL;DR: In this article, a radial fast spin-echo MRI reconstruction method was proposed to obtain spin density and relaxivity maps from only a single radial data set, which is based on an inverse formulation of the problem and involves a modeling of the received MRI signal.
Abstract: In radial fast spin-echo MRI, a set of overlapping spokes with an inconsistent T2 weighting is acquired, which results in an averaged image contrast when employing conventional image reconstruction techniques. This work demonstrates that the problem may be overcome with the use of a dedicated reconstruction method that further allows for T2 quantification by extracting the embedded relaxation information. Thus, the proposed reconstruction method directly yields a spin-density and relaxivity map from only a single radial data set. The method is based on an inverse formulation of the problem and involves a modeling of the received MRI signal. Because the solution is found by numerical optimization, the approach exploits all data acquired. Further, it handles multi-coil data and optionally allows for the incorporation of additional prior knowledge. Simulations and experimental results for a phantom and human brain in vivo demonstrate that the method yields spin-density and relaxivity maps that are neither affected by the typical artifacts from TE mixing, nor by streaking artifacts from the incomplete k-space coverage at individual echo times.

Journal ArticleDOI
TL;DR: The results suggest that it is necessary to monitor displacement continuously during HIFU therapy in order to ascertain when ablation occurs, and both conventional and fractional Zener models are used to fit the data.
Abstract: Multiple ultrasound elastography techniques rely on acoustic radiation force (ARF) in monitoring high-intensity focused ultrasound (HIFU) therapy. However, ARF is dependent on tissue attenuation and sound speed, both of which are also known to change with temperature making the therapy monitoring more challenging. Furthermore, the viscoelastic properties of tissue are also temperature dependent, which affects the displacements induced by ARF. The aim of this study is to quantify the temperature dependent changes in the acoustic and viscoelastic properties of liver and investigate their effect on ARF induced displacements by using both experimental methods and simulations. Furthermore, the temperature dependent viscoelastic properties of liver are experimentally measured over a frequency range of 0.1-200 Hz at temperatures reaching 80 C, and both conventional and fractional Zener models are used to fit the data. The fractional Zener model was found to fit better with the experimental viscoelasticity data with respect to the conventional model with up to two magnitudes lower sum of squared errors (SSE). The characteristics of experimental displacement data were also seen in the simulations due to the changes in attenuation coefficient and lesion development. At low temperatures before thermal ablation, attenuation was found to affect the displacement amplitude. At higher temperature, the decrease in displacement amplitude occurs approximately at 60-70 C due to the combined effect of viscoelasticity changes and lesion growth overpowering the effect of attenuation. The results suggest that it is necessary to monitor displacement continuously during HIFU therapy in order to ascertain when ablation occurs.

Journal ArticleDOI
TL;DR: Given the high suitability for clinical application of the alpha‐blending approach in combination with a very small methodological uncertainty, it is concluded that further refinement of image‐based DECT‐algorithms for electron density assessment is not advisable.
Abstract: Purpose: Electron density is the most important tissue property influencing photon and ion dose distributions in radiotherapy patients. Dual-energy computed tomography (DECT) enables the determination of electron density by combining the information on photon attenuation obtained at two different tube voltages. Most algorithms suggested so far use the CT numbers provided after image reconstruction as input parameters, i.e. are imaged-based. To explore the accuracy that can be achieved with these approaches, we quantify the intrinsic methodological and calibration uncertainty of the seemingly simplest approach.

Journal ArticleDOI
TL;DR: In this article, the authors established a method for estimating effective doses based on the available ambient dose rate survey data and examined the relationship between the individual external doses and the corresponding ambient doses assessed from airborne surveys.
Abstract: Date City in Fukushima Prefecture has conducted a population-wide individual dose monitoring program after the Fukushima Daiichi Nuclear Power Plant Accident, which provides a unique and comprehensive data set of the individual doses of citizens. The purpose of this paper, the first in the series, is to establish a method for estimating effective doses based on the available ambient dose rate survey data. We thus examined the relationship between the individual external doses and the corresponding ambient doses assessed from airborne surveys. The results show that the individual doses were about 0.15 times the ambient doses, the coefficient of 0.15 being a factor of 4 smaller than the value employed by the Japanese government, throughout the period of the airborne surveys used. The method obtained in this study could aid in the prediction of individual doses in the early phase of future radiological accidents involving large-scale contamination.

Journal ArticleDOI
TL;DR: In this paper, the simulation results of the scatter fraction, representing one of the parameters crucial for background studies defined in the NEMA-NU-2-2012 norm, are presented.
Abstract: A novel Positron Emission Tomography system, based on plastic scintillators, is being developed by the J-PET collaboration. In this article we present the simulation results of the scatter fraction, representing one of the parameters crucial for background studies defined in the NEMA-NU-2-2012 norm. We elaborate an event selection methods allowing to suppress events in which gamma quanta were scattered in the phantom or underwent the multiple scattering in the detector. The estimated scatter fraction for the single-layer J-PET scanner varies from 37% to 53% depending on the applied energy threshold.

Posted Content
TL;DR: A quick review of modalities used in functional brain imaging is presented, focusing on the most used techniques in functional imaging which are functional magnetic resonance imaging (fMRI) and functional optical imaging, which is one of novelties in this area of study.
Abstract: Functional brain imaging allows measuring dynamic functionality in all brain regions. It is broadly used in clinical cognitive neuroscience as, well as in research. It will allow the observation of neural activities in the brain simultaneously. From the beginning when functional brain imaging was initiated by the mapping of brain functions proposed by phrenologists, many scientists were asking why we need to image brain functionality since we have already structural information. Simply, their important question was including a great answer. Functional information of the human brain would definitely complement structural information, helping to have a better understanding of what is happening in the brain. This paper, which could be useful to those who have an interest in functional brain imaging, such as engineers, will present a quick review of modalities used in functional brain imaging. We will concentrate on the most used techniques in functional imaging which are functional magnetic resonance imaging (fMRI) and functional optical imaging, which is one of novelties in this area of study.

Journal ArticleDOI
TL;DR: In this article, a denoising algorithm designed specifically for Poisson signals is applied to derive the final scatter distribution, which can significantly reduce scatter artifacts and recover the correct HU in either projection domain or image domain.
Abstract: The purpose of this work is to provide a fast and accurate scatter artifacts correction algorithm for cone beam CT (CBCT) imaging. The method starts with an estimation of coarse scatter profiles for a set of CBCT data in either image domain or projection domain. A denoising algorithm designed specifically for Poisson signals is then applied to derive the final scatter distribution. Qualitative and quantitative evaluations using thorax and abdomen phantoms with Monte Carlo (MC) simulations, experimental Catphan phantom data, and in vivo human data acquired for a clinical image guided radiation therapy were performed. Results show that the proposed algorithm can significantly reduce scatter artifacts and recover the correct HU in either projection domain or image domain. For the MC thorax phantom study, four components segmentation yield the best results, while the results of three components segmentation are still acceptable. For the Catphan phantom data, the mean value over all pixels in the residual image is reduced from -21.8 HU to -0.2 HU and 0.7 HU for projection domain and image domain, respectively. The contrast of the in vivo human images are greatly improved after correction. The software-based technique has a number of advantages, such as high computational efficiency and accuracy, and the capability of performing scatter correction without modifying the clinical workflow or modifying the imaging hardware. When implemented practically, this should improve the accuracy of CBCT image quantitation and significantly impact CBCT-based interventional procedures and adaptive radiation therapy.

Journal ArticleDOI
TL;DR: In this article, the authors proposed a convex optimization of the mean-tail-dose of the DVH histogram to obtain better distribution of DVH statistics in intensity-modulated radiotherapy treatment.
Abstract: Conventional planning objectives in optimization of intensity-modulated radiotherapy treatment (IMRT) plans are designed to minimize the violation of dose-volume histogram (DVH) thresholds using penalty functions. Although successful in guiding the DVH curve towards these thresholds, conventional planning objectives offer limited control of the individual points on the DVH curve (doses-at-volume) used to evaluate plan quality. In this study, we abandon the usual penalty-function framework and propose planning objectives that more explicitly relate to DVH statistics. The proposed planning objectives are based on mean-tail-dose, resulting in convex optimization. We also demonstrate how to adapt a standard optimization method to the proposed formulation in order to obtain a substantial reduction in computational cost. We investigate the potential of the proposed planning objectives as tools for optimizing DVH statistics through juxtaposition with the conventional planning objectives on two patient cases. Sets of treatment plans with differently balanced planning objectives are generated using either the proposed or the conventional approach. Dominance in the sense of better distributed doses-at-volume is observed in plans optimized within the proposed framework, indicating that the DVH statistics are better optimized and more efficiently balanced using the proposed planning objectives.

Journal ArticleDOI
TL;DR: This work proposes an innovative, registration free, imaging protocol implemented to image a human tumor spheroid at mesoscopic regime, and demonstrates increased deep resolution abilities, not achievable with the current approaches, rendering the data alignment process obsolete.
Abstract: Optical tomographic imaging of biological specimen bases its reliability on the combination of both accurate experimental measures and advanced computational techniques. In general, due to high scattering and absorption in most of the tissues, multi view geometries are required to reduce diffuse halo and blurring in the reconstructions. Scanning processes are used to acquire the data but they inevitably introduces perturbation, negating the assumption of aligned measures. Here we propose an innovative, registration free, imaging protocol implemented to image a human tumor spheroid at mesoscopic regime. The technique relies on the calculation of autocorrelation sinogram and object autocorrelation, finalizing the tomographic reconstruction via a three dimensional Gerchberg Saxton algorithm that retrieves the missing phase information. Our method is conceptually simple and focuses on single image acquisition, regardless of the specimen position in the camera plane. We demonstrate increased deep resolution abilities, not achievable with the current approaches, rendering the data alignment process obsolete.

Journal ArticleDOI
TL;DR: This study quantifies the reduction of high-dose subvolumes and the robustness against these uncertainties by applying a DTMR to template-based prostate HDR brachytherapy implants and found that DTMRs were not capable of improving robustness of PTV D90% against uncertainty in dwell positions for both models.
Abstract: Inverse planning algorithms for dwell time optimisation in interstitial high-dose-rate (HDR) brachytherapy may produce solutions with large dwell time variations within catheters, which may result in undesirable selective high-dose subvolumes. Extending the optimisation model with a dwell time modulation restriction (DTMR) that limits dwell time differences between neighboring dwell positions has been suggested to eliminate this issue. DTMRs may additionally reduce the sensitivity for uncertainties in dwell positions that result from catheter reconstruction errors and source positioning inaccuracies. This study quantifies the reduction of high-dose subvolumes and the robustness against these uncertainties by applying a DTMR to template-based prostate HDR brachytherapy implants. Three different DTMRs were consecutively applied to a linear dose-based penalty model (LD) and a dose-volume based model (LDV), both obtained from literature. The models were solved with DTMR levels ranging from no restriction to uniform dwell times within catheters. Uncertainties were simulated on clinical cases using in-house developed software, and dose-volume metrics were calculated in each simulation. For the assessment of high-dose subvolumes, the dose homogeneity index (DHI) and the contiguous dose volume histogram were analysed. Robustness was measured by the improvement of the lowest $D_{90\%}$ of the planning target volume (PTV) observed in the simulations. For (LD), a DTMR yields an increase in DHI of 30% and reduces the size of the largest high-dose volume by 2 to 5 cc. This came at a cost of a reduction in $D_{90\%}$ of the PTV of 10%, which often implies that it drops below the desired minimum of 100%. For (LDV), none of the DTMRs improved high-dose volume measures. DTMRs were not capable of improving robustness of PTV $D_{90\%}$ against uncertainty in dwell positions for both models.

Posted Content
TL;DR: In this article, a series of simulations about the potential use of Boron isotopes to trigger neutron-free (aneutronic) nuclear reactions in cancer cells through the interaction with an incoming energetic proton beam, thus resulting in the emission of characteristic prompt gamma radiation (429 keV, 718 keV and 1435 keV).
Abstract: We propose a series of simulations about the potential use of Boron isotopes to trigger neutron-free (aneutronic) nuclear reactions in cancer cells through the interaction with an incoming energetic proton beam, thus resulting in the emission of characteristic prompt gamma radiation (429 keV, 718 keV and 1435 keV). Furthermore assuming that the Boron isotopes are absorbed in cancer cells, the three alpha-particles produced in each p-11B aneutronic nuclear fusion reactions can potentially result in the enhancement of the biological dose absorbed in the tumor region since these multi-MeV alpha-particles are stopped inside the single cancer cell, thus allowing to spare the surrounding tissues. Although a similar approach based on the use of 11B nuclei has been proposed in [1], our work demonstrate, using Monte Carlo simulations, the crucial importance of the use of 10B nuclei (in a solution containing also 11B) for the generation of prompt gamma-rays, which can be applied to medical imaging. In fact, we demonstrate that the use of 10B nuclei can enhance the intensity of the 718 keV gamma-ray peak more than 30 times compared to the solution containing only 11B nuclei. A detailed explanation of the origin of the different prompt gamma-rays, as well as of their application as real-time diagnostics during a potential cancer treatment, is here discussed.

Posted Content
TL;DR: The two systems Catalyst and AlignRT were most accurate in the head & neck region, where conventional mask alignment is already sufficiently accurate, but for both systems there is still a need for improvement to reduce statistical variation.
Abstract: Precise patient positioning and thus precise positioning of the planning target volume (PTV) is a prerequisite for effective treatment in percutaneous radiation therapy. Conventional imaging modalities used to ensure exact positioning for treatment typically involve additional radiation exposure of the patient. A different approach to patient alignment without additional exposure is provided by optical 3D surface scanning and registration systems. We investigated two systems Catalyst and AlignRT, which allowed us to generate and validate surface images of 50 patients undergoing irradiation on a Tomotherapy system. We compared the positions proposed by these two surface imaging systems (SIS) with the actual adjustments in patient positions made on the basis of MVCT scans. With the two SIS, the surface of every single patient was repeatedly recorded throughout treatment. In addition, we performed a systematic analysis of both systems using a body phantom. At least 10 surface images were available from each patient included in the analysis. The large number of patients allowed us to subdivide the study population into three groups by body region treated: head & neck, chest, and pelvic. The results for each of these three body regions were separately analyzed. Thus, the focus of our investigation is on body regions registered with the two systems rather than tumor entities. For AlignRT, for instance, we found an improvement in positioning for the Pelvic region of 0.9mm in 75% and 6.4mm in 95% of the collected data in comparison to conventional marker alignment. The two systems were most accurate in the head & neck region, where conventional mask alignment is already sufficiently accurate. The other two body regions, pelvic and chest, might benefit from positioning by SIS. But for both systems there is still a need for improvement to reduce statistical variation.