scispace - formally typeset
Search or ask a question
JournalISSN: 0885-3010

IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control 

Institute of Electrical and Electronics Engineers
About: IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control is an academic journal published by Institute of Electrical and Electronics Engineers. The journal publishes majorly in the area(s): Ultrasonic sensor & Transducer. It has an ISSN identifier of 0885-3010. Over the lifetime, 7299 publications have been published receiving 248852 citations. The journal is also known as: Transactions on ultrasonics, ferroelectrics, and frequency control & IEEE Trans Ultrason Ferroelectr Freq Control.


Papers
More filters
Journal ArticleDOI
TL;DR: A method for simulation of pulsed pressure fields from arbitrarily shaped, apodized and excited ultrasound transducers is suggested, which relies on the Tupholme-Stepanishen method for calculating pulsing pressure fields and can also handle the continuous wave and pulse-echo case.
Abstract: A method for simulation of pulsed pressure fields from arbitrarily shaped, apodized and excited ultrasound transducers is suggested. It relies on the Tupholme-Stepanishen method for calculating pulsed pressure fields, and can also handle the continuous wave and pulse-echo case. The field is calculated by dividing the surface into small rectangles and then Summing their response. A fast calculation is obtained by using the far-field approximation. Examples of the accuracy of the approach and actual calculation times are given. >

2,340 citations

Journal ArticleDOI
TL;DR: The first in vivo investigations made on healthy volunteers emphasize the potential clinical applicability of SSI for breast cancer detection and results validating SSI in heterogeneous phantoms are presented.
Abstract: Supersonic shear imaging (SSI) is a new ultrasound-based technique for real-time visualization of soft tissue viscoelastic properties. Using ultrasonic focused beams, it is possible to remotely generate mechanical vibration sources radiating low-frequency, shear waves inside tissues. Relying on this concept, SSI proposes to create such a source and make it move at a supersonic speed. In analogy with the "sonic boom" created by a supersonic aircraft, the resulting shear waves will interfere constructively along a Mach cone, creating two intense plane shear waves. These waves propagate through the medium and are progressively distorted by tissue heterogeneities. An ultrafast scanner prototype is able to both generate this supersonic source and image (5000 frames/s) the propagation of the resulting shear waves. Using inversion algorithms, the shear elasticity of medium can be mapped quantitatively from this propagation movie. The SSI enables tissue elasticity mapping in less than 20 ms, even in strongly viscous medium like breast. Modalities such as shear compounding are implementable by tilting shear waves in different directions and improving the elasticity estimation. Results validating SSI in heterogeneous phantoms are presented. The first in vivo investigations made on healthy volunteers emphasize the potential clinical applicability of SSI for breast cancer detection.

2,300 citations

Journal ArticleDOI
TL;DR: It is proposed to improve the beamforming process by using a coherent recombination of compounded plane-wave transmissions to recover high-quality echographic images without degrading the high frame rate capabilities.
Abstract: The emergence of ultrafast frame rates in ultrasonic imaging has been recently made possible by the development of new imaging modalities such as transient elastography. Data acquisition rates reaching more than thousands of images per second enable the real-time visualization of shear mechanical waves propagating in biological tissues, which convey information about local viscoelastic properties of tissues. The first proposed approach for reaching such ultrafast frame rates consists of transmitting plane waves into the medium. However, because the beamforming process is then restricted to the receive mode, the echographic images obtained in the ultrafast mode suffer from a low quality in terms of resolution and contrast and affect the robustness of the transient elastography mode. It is here proposed to improve the beamforming process by using a coherent recombination of compounded plane-wave transmissions to recover high-quality echographic images without degrading the high frame rate capabilities. A theoretical model is derived for the comparison between the proposed method and the conventional B-mode imaging in terms of contrast, signal-to-noise ratio, and resolution. Our model predicts that a significantly smaller number of insonifications, 10 times lower, is sufficient to reach an image quality comparable to conventional B-mode. Theoretical predictions are confirmed by in vitro experiments performed in tissue-mimicking phantoms. Such results raise the appeal of coherent compounds for use with standard imaging modes such as B-mode or color flow. Moreover, in the context of transient elastography, ultrafast frame rates can be preserved while increasing the image quality compared with flat insonifications. Improvements on the transient elastography mode are presented and discussed.

1,442 citations

Journal ArticleDOI
Mathias Fink1
TL;DR: Pulsed wave time-reversal focusing is shown using reciprocity valid in inhomogeneous medium to be optimal in the sense that it realizes the spatial-temporal matched filter to the inhomogeneity propagation transfer function between the array and the target.
Abstract: Time reversal of ultrasonic fields represents a way to focus through an inhomogeneous medium. This may be accomplished by a time-reversal mirror (TRM) made from an array of transmit-receive transducers that respond linearly and allow the incident acoustic pressure to be sampled. The pressure field is then time-reversed and re-emitted. This process can be used to focus through inhomogeneous media on a reflective target that behaves as an acoustic source after being insonified. The time-reversal approach is introduced in a discussion of the classical techniques used for focusing pulsed waves through inhomogeneous media (adaptive time-delay techniques). Pulsed wave time-reversal focusing is shown using reciprocity valid in inhomogeneous medium to be optimal in the sense that it realizes the spatial-temporal matched filter to the inhomogeneous propagation transfer function between the array and the target. The research on time-reversed wave fields has also led to the development of new concepts that are described: time-reversal cavity that extends the concept of the TRM, and iterative time-reversal processing for automatic sorting of targets according to their reflectivity and resonating of extended targets. >

1,407 citations

Journal ArticleDOI
TL;DR: This technique, called synchronized switch harvesting (SSH), is derived from the synchronized switch damping (SSD), which is a nonlinear technique previously developed to address the problem of vibration damping on mechanical structures, results in a significant increase of the electromechanical conversion capability of piezoelectric materials.
Abstract: This paper presents a new technique of electrical energy generation using mechanically excited piezoelectric materials and a nonlinear process. This technique, called synchronized switch harvesting (SSH), is derived from the synchronized switch damping (SSD), which is a nonlinear technique previously developed to address the problem of vibration damping on mechanical structures. This technique results in a significant increase of the electromechanical conversion capability of piezoelectric materials. Comparatively with standard technique, the electrical harvested power may be increased above 900%. The performance of the nonlinear processing is demonstrated on structures excited at their resonance frequency as well as out of resonance.

949 citations

Performance
Metrics
No. of papers from the Journal in previous years
YearPapers
2023178
2022480
2021337
2020276
2019187
2018238