Journal ArticleDOI
TL;DR: A Web-based method for MLST of 66 bacterial species based on whole-genome sequencing data that enables investigators to determine the sequence types of their isolates on the basis of WGS data.
Abstract: Accurate strain identification is essential for anyone working with bacteria. For many species, multilocus sequence typing (MLST) is considered the “gold standard” of typing, but it is traditionally performed in an expensive and time-consuming manner. As the costs of whole-genome sequencing (WGS) continue to decline, it becomes increasingly available to scientists and routine diagnostic laboratories. Currently, the cost is below that of traditional MLST. The new challenges will be how to extract the relevant information from the large amount of data so as to allow for comparison over time and between laboratories. Ideally, this information should also allow for comparison to historical data. We developed a Web-based method for MLST of 66 bacterial species based on WGS data. As input, the method uses short sequence reads from four sequencing platforms or preassembled genomes. Updates from the MLST databases are downloaded monthly, and the best-matching MLST alleles of the specified MLST scheme are found using a BLAST-based ranking method. The sequence type is then determined by the combination of alleles identified. The method was tested on preassembled genomes from 336 isolates covering 56 MLST schemes, on short sequence reads from 387 isolates covering 10 schemes, and on a small test set of short sequence reads from 29 isolates for which the sequence type had been determined by traditional methods. The method presented here enables investigators to determine the sequence types of their isolates on the basis of WGS data. This method is publicly available at www.cbs.dtu.dk/services/MLST.

1,620 citations


Journal ArticleDOI
TL;DR: Using a consistent schema for nomenclature of the Stx toxins and stx genes by phylogenetic sequence-based relatedness of the holotoxin proteins, a typing approach should obviate the need to bioassay each newly described toxin and that predicts important biological characteristics.
Abstract: When Shiga toxin-producing Escherichia coli (STEC) strains emerged as agents of human disease, two types of toxin were identified: Shiga toxin type 1 (Stx1) (almost identical to Shiga toxin produced by Shigella dysenteriae type 1) and the immunologically distinct type 2 (Stx2). Subsequently, numerous STEC strains have been characterized that express toxins with variations in amino acid sequence, some of which confer unique biological properties. These variants were grouped within the Stx1 or Stx2 type and often assigned names to indicate that they were not identical in sequence or phenotype to the main Stx1 or Stx2 type. A lack of specificity or consistency in toxin nomenclature has led to much confusion in the characterization of STEC strains. Because serious outcomes of infection have been attributed to certain Stx subtypes and less so with others, we sought to better define the toxin subtypes within the main Stx1 and Stx2 types. We compared the levels of relatedness of 285 valid sequence variants of Stx1 and Stx2 and identified common sequences characteristic of each of three Stx/Stx1 and seven Stx2 subtypes. A novel, simple PCR subtyping method was developed, independently tested on a battery of 48 prototypic STEC strains, and improved at six clinical and research centers to test the reproducibility, sensitivity, and specificity of the PCR. Using a consistent schema for nomenclature of the Stx toxins and stx genes by phylogenetic sequence-based relatedness of the holotoxin proteins, we developed a typing approach that should obviate the need to bioassay each newly described toxin and that predicts important biological characteristics.

677 citations


Journal ArticleDOI
TL;DR: Bacteria that are not or cannot be routinely cultivated (hereinafter called uncultivated bacteria) were common in voided urine, urine collected by transurethral catheter (TUC), and urine collection by suprapubic aspirate (SPA), regardless of whether the subjects had urinary symptoms.
Abstract: Clinical urine specimens are usually considered to be sterile when they do not yield uropathogens using standard clinical cultivation procedures. Our aim was to test if the adult female bladder might contain bacteria that are not identified by these routine procedures. An additional aim was to identify and recommend the appropriate urine collection method for the study of bacterial communities in the female bladder. Consenting participants who were free of known urinary tract infection provided urine samples by voided, transurethral, and/or suprapubic collection methods. The presence of bacteria in these samples was assessed by bacterial culture, light microscopy, and 16S rRNA gene sequencing. Bacteria that are not or cannot be routinely cultivated (hereinafter called uncultivated bacteria) were common in voided urine, urine collected by transurethral catheter (TUC), and urine collected by suprapubic aspirate (SPA), regardless of whether the subjects had urinary symptoms. Voided urine samples contained mixtures of urinary and genital tract bacteria. Communities identified in parallel urine samples collected by TUC and SPA were similar. Uncultivated bacteria are clearly present in the bladders of some women. It remains unclear if these bacteria are viable and/or if their presence is relevant to idiopathic urinary tract conditions.

508 citations


Journal ArticleDOI
TL;DR: This brief review serves as an update on the new developments in the antifungal susceptibility testing of Candida spp.
Abstract: Antifungal susceptibility testing of Candida has been standardized and refined and now may play a useful role in managing Candida infections. Important new developments include validation of 24-h reading times for all antifungal agents and the establishment of species-specific epidemiological cutoff values (ECVs) for the systemically active antifungal agents and both common and uncommon species of Candida. The clinical breakpoints (CBPs) for fluconazole, voriconazole, and the echinocandins have been revised to provide species-specific interpretive criteria for the six most common species. The revised CBPs not only are predictive of clinical outcome but also provide a more sensitive means of identifying those strains with acquired or mutational resistance mechanisms. This brief review serves as an update on the new developments in the antifungal susceptibility testing of Candida spp. using Clinical and Laboratory Standards Institute (CLSI) broth microdilution (BMD) methods.

413 citations


Journal ArticleDOI
TL;DR: These data document the broad emergence of coresistance over time to both azoles and echinocandins in clinical isolates of C. glabrata and suggest that the first-line treatment of bloodstream infections due to Candida glabRata is still the best option.
Abstract: The echinocandin class of antifungal agents is considered to be the first-line treatment of bloodstream infections (BSI) due to Candida glabrata. Recent reports of BSI due to strains of C. glabrata resistant to both fluconazole and the echinocandins are of concern and prompted us to review the experience of two large surveillance programs, the SENTRY Antimicrobial Surveillance Program for the years 2006 through 2010 and the Centers for Disease Control and Prevention population-based surveillance conducted in 2008 to 2010. The in vitro susceptibilities of 1,669 BSI isolates of C. glabrata to fluconazole, voriconazole, anidulafungin, caspofungin, and micafungin were determined by CLSI broth microdilution methods. Fluconazole MICs of ≥64 μg/ml were considered resistant. Strains for which anidulafungin and caspofungin MICs were ≥0.5 μg/ml and for which micafungin MICs were ≥0.25 μg/ml were considered resistant. A total of 162 isolates (9.7%) were resistant to fluconazole, of which 98.8% were nonsusceptible to voriconazole (MIC > 0.5 μg/ml) and 9.3%, 9.3%, and 8.0% were resistant to anidulafungin, caspofungin, and micafungin, respectively. There were 18 fluconazole-resistant isolates that were resistant to one or more of the echinocandins (11.1% of all fluconazole-resistant isolates), all of which contained an acquired mutation in fks1 or fks2. By comparison, there were no echinocandin-resistant strains detected among 110 fluconazole-resistant isolates of C. glabrata tested in 2001 to 2004. These data document the broad emergence of coresistance over time to both azoles and echinocandins in clinical isolates of C. glabrata.

324 citations


Journal ArticleDOI
TL;DR: A MALDI-TOF MS-based assay was set up to investigate different enterobacteria for resistance against different β-lactam antibiotics, and identical classification of the bacteria according to sensitivity and resistance was revealed.
Abstract: Resistance against β-lactam antibiotics is a growing challenge for managing severe bacterial infections. The rapid and cost-efficient determination of β-lactam resistance is an important prerequisite for the choice of an adequate antibiotic therapy. β-Lactam resistance is based mainly on the expression/overexpression of β-lactamases, which destroy the central β-lactam ring of these drugs by hydrolysis. Hydrolysis corresponds to a mass shift of +18 Da, which can be easily detected by matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS). Therefore, a MALDI-TOF MS-based assay was set up to investigate different enterobacteria for resistance against different β-lactam antibiotics: ampicillin, piperacillin, cefotaxime, ceftazidime, ertapenem, imipenem, and meropenem. β-Lactamases are enzymes that have a high turnover rate. Therefore, hydrolysis can be detected by MALDI-TOF MS already after a few hours of incubation of the bacteria to be tested with the given antibiotic. The comparison of the MS-derived data with the data from the routine procedure revealed identical classification of the bacteria according to sensitivity and resistance. The MALDI-TOF MS-based assay delivers the results on the same day. The approved routine procedures require at least an additional overnight incubation.

301 citations


Journal ArticleDOI
TL;DR: Evaluating the modified Hodge test, Mastdiscs ID inhibitor combination disks, Rosco Diagnostica Neo-Sensitabs, and in-house multiplex PCR for the detection of well-characterized carbapenemase-producing Enterobacteriaceae found MDI and RDS were easy to perform and interpret but lacked sensitivity for OXA-48-like enzymes, VIMs, and IMPs.
Abstract: A study was designed to evaluate the modified Hodge test (MHT), Mastdiscs ID inhibitor combination disks (MDI), Rosco Diagnostica Neo-Sensitabs (RDS), metallo-β-lactamase (MBL) Etest, and in-house multiplex PCR for the detection of well-characterized carbapenemase-producing Enterobacteriaceae. One hundred forty-two nonrepeat clinical isolates of carbapenemase-producing Enterobacteriaceae (including Klebsiella spp., Escherichia coli, Citrobacter freundii, and Enterobacter spp.) obtained from the SMART worldwide surveillance program during 2008 to 2009 were included. These included 49 KPC-, 27 NDM-, 19 VIM-, 14 OXA-48-like enzyme-, and 5 IMP-producing isolates and 28 carbapenem-resistant, carbapenemase-negative isolates. The manufacturer9s instructions were followed for MDI, RDS, and MBL Etest and CLSI guidelines for MHT. A multiplex PCR was designed to detect KPC, NDM, VIM, IMP, and OXA-48-like carbapenemases. Overall, the sensitivity and specificity were 78% and 93% for MDI, 80% and 93% for RDS, 58% and 93% for MHT, and 55% and 100% for MBL Etest, respectively. The PCR had 100% sensitivity and specificity. MDI and RDS performed well for the detection of KPCs and NDMs but poorly for VIMs, IMPs, and OXA-48-like enzymes. MHT performed well for KPCs and OXA-48-like enzymes but poorly for NDMs, VIMs, and IMPs. MDI and RDS were easy to perform and interpret but lacked sensitivity for OXA-48-like enzymes, VIMs, and IMPs. MHT and MBL Etest were often difficult to interpret. We recommend using molecular tests for the optimal detection of carbapenemase-producing Enterobacteriaceae.

298 citations


Journal ArticleDOI
TL;DR: In this prospective study, a protocol incorporating MALDI-TOF MS (MALDI protocol) with the current standard identification protocols (standard protocol) is compared to determine the performance in actual practice using a specimen-based, bench-by-bench approach.
Abstract: Matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF MS) has been found to be an accurate, rapid, and inexpensive method for the identification of bacteria and yeasts. Previous evaluations have compared the accuracy, time to identification, and costs of the MALDI-TOF MS method against standard identification systems or commercial panels. In this prospective study, we compared a protocol incorporating MALDI-TOF MS (MALDI protocol) with the current standard identification protocols (standard protocol) to determine the performance in actual practice using a specimen-based, bench-by-bench approach. The potential impact on time to identification (TTI) and costs had MALDI-TOF MS been the first-line identification method was quantitated. The MALDI protocol includes supplementary tests, notably for Streptococcus pneumoniae and Shigella, and indications for repeat MALDI-TOF MS attempts, often not measured in previous studies. A total of 952 isolates (824 bacterial isolates and 128 yeast isolates) recovered from 2,214 specimens were assessed using the MALDI protocol. Compared with standard protocols, the MALDI protocol provided identifications 1.45 days earlier on average (P < 0.001). In our laboratory, we anticipate that the incorporation of the MALDI protocol can reduce reagent and labor costs of identification by $102,424 or 56.9% within 12 months. The model included the fixed annual costs of the MALDI-TOF MS, such as the cost of protein standards and instrument maintenance, and the annual prevalence of organisms encountered in our laboratory. This comprehensive cost analysis model can be generalized to other moderate- to high-volume laboratories.

294 citations


Journal ArticleDOI
TL;DR: Clinical relevance, phenotypic and genetic identification methods, matrix-assisted laser desorption ionization–time of flight evaluations, and antimicrobial susceptibility testing involving species in the genus Corynebacterium and other medically relevant Gram-positive rods, collectively called coryneforms are described.
Abstract: Catalase-positive Gram-positive bacilli, commonly called "diphtheroids" or "coryneform" bacteria were historically nearly always dismissed as contaminants when recovered from patients, but increasingly have been implicated as the cause of significant infections These taxa have been underreported, and the taxa were taxonomically confusing The mechanisms of pathogenesis, especially for newly described taxa, were rarely studied Antibiotic susceptibility data were relatively scant In this minireview, clinical relevance, phenotypic and genetic identification methods, matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) evaluations, and antimicrobial susceptibility testing involving species in the genus Corynebacterium and other medically relevant Gram-positive rods, collectively called coryneforms, are described

282 citations


Journal ArticleDOI
TL;DR: The diagnostic accuracy of the BG assay is high for PJP and moderate for IFI, and the sensitivity for P JP is particularly high, so it can be used as a screening tool forPJP.
Abstract: Serum 1,3-β-d-glucan (BG) assay may be helpful as a marker for the diagnosis of Pneumocystis jiroveci pneumonia (PJP) and invasive fungal infection (IFI). We conducted a systematic review to assess the diagnostic accuracy of this assay. We searched MEDLINE, Web of Science, Cochrane Collaboration databases, Ichushi-Web, reference lists of retrieved studies, and review articles. Our search included studies of serum BG assay that used (i) positive cytological or direct microscopic examination of sputum or bronchoalveolar lavage fluid for PJP and (ii) European Organization for Research and Treatment of Cancer or similar criteria for IFI as a reference standard and provided data to calculate sensitivity and specificity. Only major fungal infections such as invasive candidiasis and invasive aspergillosis were included in the IFI group. Twelve studies for PJP and 31 studies for IFI were included from January 1966 to November 2010. The pooled sensitivity, specificity, diagnostic odds ratio (DOR), and area under the summary receiver operating characteristic curve (AUC-SROC) for PJP were 96% (95% confidence interval [95% CI], 92% to 98%), 84% (95% CI, 83% to 86%), 102.3 (95% CI, 59.2 to 176.6) and 0.96 (95% CI, 0.94 to 0.99), respectively. No heterogeneity was found. For IFI, the values were 80% (95% CI, 77% to 82%), 82% (95% CI, 81% to 83%), 25.7 (95% CI, 15.0 to 44.1), and 0.88 (95% CI, 0.82 to 0.93). Heterogeneity was significant. The diagnostic accuracy of the BG assay is high for PJP and moderate for IFI. Because the sensitivity for PJP is particularly high, the BG assay can be used as a screening tool for PJP.

256 citations


Journal ArticleDOI
TL;DR: There was no change in the proportion of fluconazole resistance between surveillance periods, but overall echinocandin resistance was low but was higher for C. glabrata than other Candida species, which should be closely monitored in future surveillance.
Abstract: Between 2008 and 2011, population-based candidemia surveillance was conducted in Atlanta, GA, and Baltimore, MD. Surveillance had been previously performed in Atlanta in 1992 to 1993 and in Baltimore in 1998 to 2000, making this the first population-based candidemia surveillance conducted over multiple time points in the United States. From 2,675 identified cases of candidemia in the current surveillance, 2,329 Candida isolates were collected. Candida albicans no longer comprised the majority of isolates but remained the most frequently isolated species (38%), followed by Candida glabrata (29%), Candida parapsilosis (17%), and Candida tropicalis (10%). The species distribution has changed over time; in both Atlanta and Baltimore the proportion of C. albicans isolates decreased, and the proportion of C. glabrata isolates increased, while the proportion of C. parapsilosis isolates increased in Baltimore only. There were 98 multispecies episodes, with C. albicans and C. glabrata the most frequently encountered combination. The new species-specific CLSI Candida MIC breakpoints were applied to these data. With the exception of C. glabrata (11.9% resistant), resistance to fluconazole was very low (2.3% of isolates for C. albicans, 6.2% for C. tropicalis, and 4.1% for C. parapsilosis). There was no change in the proportion of fluconazole resistance between surveillance periods. Overall echinocandin resistance was low (1% of isolates) but was higher for C. glabrata isolates, ranging from 2.1% isolates resistant to caspofungin in Baltimore to 3.1% isolates resistant to anidulafungin in Atlanta. Given the increase at both sites and the higher echinocandin resistance, C. glabrata should be closely monitored in future surveillance.

Journal ArticleDOI
TL;DR: Broad-range PCR and culture of sonicate fluid have equivalent performance for PJI diagnosis and sensitivity was higher than those of individual tests, with similar specificity.
Abstract: Periprosthetic tissue and/or synovial fluid PCR has been previously studied for prosthetic joint infection (PJI) diagnosis; however, few studies have assessed the utility of PCR on biofilms dislodged from the surface of explanted arthroplasties using vortexing and sonication (i.e., sonicate fluid PCR). We compared sonicate fluid 16S rRNA gene real-time PCR and sequencing to culture of synovial fluid, tissue, and sonicate fluid for the microbiologic diagnosis of PJI. PCR sequences generating mixed chromatograms were decatenated using RipSeq Mixed. We studied sonicate fluids from 135 and 231 subjects with PJI and aseptic failure, respectively. Synovial fluid, tissue, and sonicate fluid culture and sonicate fluid PCR had similar sensitivities (64.7, 70.4, 72.6, and 70.4%, respectively; P > 0.05) and specificities (96.9, 98.7, 98.3, and 97.8%, respectively; P > 0.05). Combining sonicate fluid culture and PCR, the sensitivity was higher (78.5%, P < 0.05) than those of individual tests, with similar specificity (97.0%). Thirteen subjects had positive sonicate fluid culture but negative PCR, and 11 had negative sonicate fluid culture but positive PCR (among which 7 had prior use of antimicrobials). Broad-range PCR and culture of sonicate fluid have equivalent performance for PJI diagnosis.

Journal ArticleDOI
TL;DR: The modified Hodge test has an excellent sensitivity for detecting enterobacterial isolates producing Ambler class A (KPC) and class D (OXA-48) carbapenemases as discussed by the authors.
Abstract: The modified Hodge test has an excellent sensitivity for detecting enterobacterial isolates producing Ambler class A (KPC) and class D (OXA-48) carbapenemases. Its sensitivity is low for NDM-1 producers (50%) but is increased to 85.7% by adding ZnSO4 (100 μg/ml) in the culture medium. However, this test has a low specificity and is time-consuming.

Journal ArticleDOI
TL;DR: Compared the performance of three matrix-assisted laser desorption ionization–time of flight mass spectrometry systems, the Microflex LT and Vitek-MS systems are equally good choices in terms of analytical efficiency.
Abstract: This study compared the performance of three matrix-assisted laser desorption ionization–time of flight mass spectrometry systems: Microflex LT (Bruker Daltonics, Bremen, Germany), Vitek MS RUO (Axima Assurance-Saramis database; bioMerieux, Marcy l'Etoile, France), and Vitek MS IVD (bioMerieux). A total of 1,129 isolates, including 1,003 routine isolates, 73 anaerobes, and 53 bacterial enteropathogens, were tested on the Microflex LT and Axima Assurance devices. The spectra were analyzed using three databases: Biotyper (Bruker Daltonics), Saramis, and Vitek MS (bioMerieux). Among the routine isolates requiring identification to the species level (n = 986), 92.7% and 93.2% were correctly identified by the Biotyper and Vitek MS databases, respectively. The Vitek MS database is more specific for the identification of Streptococcus viridans. For the anaerobes, the Biotyper database often identified Fusobacterium isolates to only the genus level, which is of low clinical significance, whereas 20% of the Bacteroides species were not identified or were misidentified by the Vitek MS database. For the enteropathogens, the poor discrimination between Escherichia coli and Shigella explains the high proportion of unidentified organisms. In contrast to the Biotyper database, the Vitek MS database properly discriminated all of the Salmonella entrica serovar Typhi isolates (n = 5). The performance of the Saramis database was globally poorer. In conclusion, for routine procedures, the Microflex LT and Vitek-MS systems are equally good choices in terms of analytical efficiency. Other factors, including price, work flow, and lab activity, will affect the choice of a system.

Journal ArticleDOI
TL;DR: Results suggest that MRSA genotypes associated with hospitals and community can be isolated from milk at very low rates.
Abstract: Staphylococcus aureus is a common causative agent of bovine mastitis in dairy herds. The emergence of methicillin-resistant Staphylococcus aureus (MRSA) in hospitals as well as the community is a significant and costly public health concern. S. aureus-related bovine mastitis is a common reason for therapeutic and/or prophylactic use of antibiotics on dairy farms. In this study, herd prevalence of S. aureus, including MRSA, was estimated from bulk tank milk (BTM) from Minnesota farms. A total of 150 pooled BTM samples from 50 farms, collected over 3 seasons (spring, summer, and fall of 2009), were assessed. Herd prevalence of methicillin-susceptible S. aureus (MSSA) was 84%, while MRSA herd prevalence was 4%. A total of 93 MSSA isolates and 2 MRSA isolates were recovered from 150 BTM samples. Antibiotic susceptibility testing of S. aureus isolates showed pansusceptibility in 54 isolates, resistance to a single antibiotic class in 21 isolates, resistance to two antibiotic classes in 13 isolates, and resistance to ≥3 antibiotics classes and thus multidrug resistance in 5 isolates. The two MRSA isolates displayed resistance to β-lactams, cephalosporins, and lincosamides and were multiresistant. Staphylococcal protein A gene (spa) typing identified spa types t529 and t034 most frequently among methicillin-susceptible isolates, while t121 was observed in MRSA isolates. Seven isolates, including the two MRSA isolates, produced staphylococcal enterotoxins B, C, D, and E on overnight culture. MRSA isolates were further genotyped using multilocus sequence typing (MLST) and pulsed-field gel electrophoresis (PFGE). Of the 2 MRSA isolates, one had a composite genotype profile of MLST ST 5-PFGE USA100-unknown spa type, which has been reported among hospital-associated MRSA isolates, while the second isolate carried the MLST ST 8-PFGE USA300-spa type t121 genotype, commonly identified among community-associated MRSA isolates. These results suggest that MRSA genotypes associated with hospitals and community can be isolated from milk at very low rates.

Journal ArticleDOI
TL;DR: The carriage rate of Clostridium difficile by culture as a function of fecal microbiota composition in elderly subjects recruited from the community, including outpatient, short-term respite, and long-term hospital stay subjects was examined.
Abstract: Clostridium difficile is an important nosocomial pathogen associated particularly with diarrheal disease in elderly individuals in hospitals and long-term care facilities. We examined the carriage rate of Clostridium difficile by culture as a function of fecal microbiota composition in elderly subjects recruited from the community, including outpatient, short-term respite, and long-term hospital stay subjects. The carriage rate ranged from 1.6% (n = 123) for subjects in the community, to 9.5% (n = 43) in outpatient settings, and increasing to 21% (n = 151) for patients in short- or long-term care in hospital. The dominant 072 ribotype was carried by 43% (12/28) of subjects, while the hypervirulent strain R027 (B1/NAP1/027) was isolated from 3 subjects (11%), 2 of whom displayed C. difficile associated diarrhea (CDAD) symptoms at the time of sampling. Emerging ribotypes with enhanced virulence (078 and 018) were also isolated from two asymptomatic subjects. Pyrosequencing of rRNA gene amplicons was used to determine the composition of the fecal microbiota as a surrogate for the microbial population structure of the distal intestine. Asymptomatic subjects (n = 20) from whom C. difficile was isolated showed no dramatic difference at the phylum or family taxonomic level compared to those that were culture negative (n = 252). However, in contrast, a marked reduction in microbial diversity at genus level was observed in patients who had been diagnosed with CDAD at the time of sampling and from whom C. difficile R027 was isolated.

Journal ArticleDOI
TL;DR: The data confirm that the bronchial tree is not sterile in COPD patients and support the existence of a different microbiota in the upper and lower compartments.
Abstract: Culture of bacteria from bronchial secretions in respiratory patients has low sensitivity and does not allow for complete assessment of microbial diversity across different bronchial compartments. In addition, a significant number of clinical studies are based on sputum samples, and it is not known to what extent they describe the real diversity of the mucosa. In order to identify previously unrecognized lower airway bacteria and to investigate the complexity and distribution of microbiota in patients with chronic obstructive pulmonary disease (COPD), we performed PCR amplification and pyrosequencing of the 16S rRNA gene in patients not showing signs or symptoms of infection. Four types of respiratory samples (sputum, bronchial aspirate, bronchoalveolar lavage, and bronchial mucosa) were taken from each individual, obtaining on average >1,000 16S rRNA sequences per sample. The total number of genera per patient was >100, showing a high diversity, with Streptococcus, Prevotella, Moraxella, Haemophilus, Acinetobacter, Fusobacterium, and Neisseria being the most commonly identified. Sputum samples showed significantly lower diversity than the other three sample types. Lower-bronchial-tree samples, i.e., bronchoalveolar lavage and bronchial mucosa, showed a very similar bacterial compositions in contrast to sputum and bronchial aspirate samples. Thus, sputum and bronchial aspirate samples are upper bronchial tree samples that are not representative of the lower bronchial mucosa flora, and bronchoalveolar lavage samples showed the results closest to those for the bronchial mucosa. Our data confirm that the bronchial tree is not sterile in COPD patients and support the existence a different microbiota in the upper and lower compartments.

Journal ArticleDOI
TL;DR: The reliability of the Bruker Daltonik's MALDI Biotyper system in species-level identification of yeasts directly from blood culture bottles is evaluated, suggesting that this approach is a reliable, time-saving tool for routine identification of Candida species causing bloodstream infection.
Abstract: We evaluated the reliability of the Bruker Daltonik's MALDI Biotyper system in species-level identification of yeasts directly from blood culture bottles. Identification results were concordant with those of the conventional culture-based method for 95.9% of Candida albicans (187/195) and 86.5% of non-albicans Candida species (128/148). Results were available in 30 min (median), suggesting that this approach is a reliable, time-saving tool for routine identification of Candida species causing bloodstream infection.

Journal ArticleDOI
TL;DR: The introduction of copper surfaces to objects formerly covered with plastic, wood, stainless steel, and other materials found in the patient care environment significantly reduced the overall MB on a continuous basis, thereby providing a potentially safer environment for hospital patients, health care workers, and visitors.
Abstract: The contribution of environmental surface contamination with pathogenic organisms to the development of health care-associated infections (HAI) has not been well defined The microbial burden (MB) associated with commonly touched surfaces in intensive care units (ICUs) was determined by sampling six objects in 16 rooms in ICUs in three hospitals over 43 months At month 23, copper-alloy surfaces, with inherent antimicrobial properties, were installed onto six monitored objects in 8 of 16 rooms, and the effect that this application had on the intrinsic MB present on the six objects was assessed Census continued in rooms with and without copper for an additional 21 months In concert with routine infection control practices, the average MB found for the six objects assessed in the clinical environment during the preintervention phase was 28 times higher (6,985 CFU/ 100 cm 2 ;n3,977 objects sampled) than levels proposed as benign immediately after terminal cleaning (<250 CFU/100 cm 2 ) During the intervention phase, the MB was found to be significantly lower for both the control and copper-surfaced objects Copper was found to cause a significant (83%) reduction in the average MB found on the objects (465 CFU/100 cm 2 ;n2714 objects) compared to the controls (2,674 CFU/100 cm 2 ;n2,831 objects [P<00001]) The introduction of copper surfaces to objects formerly covered with plastic, wood, stainless steel, and other materials found in the patient care environment significantly reduced the overall MB on a continuous basis, thereby providing a potentially safer environment for hospital patients, health care workers (HCWs), and visitors

Journal ArticleDOI
TL;DR: The new species and the new variety have a multiresistant antifungal profile, which includes high MICs of amphotericin B and cross-resistance to azole compounds and should be based on molecular methods, such as sequence analysis of ITS regions and matrix-assisted laser desorption ionization–time of flight mass spectrometry.
Abstract: The Candida haemulonii species complex is currently known as C. haemulonii groups I and II. Here we describe C. haemulonii group II as a new species, Candida duobushaemulonii sp. nov., and C. haemulonii var. vulnera as new a variety of C. haemulonii group I using phenotypic and molecular methods. These taxa and other relatives of C. haemulonii (i.e., Candida auris and Candida pseudohaemulonii) cannot be differentiated by the commercial methods now used for yeast identification. Four isolates (C. haemulonii var. vulnera) differed from the other isolates of C. haemulonii in the sequence of the internal transcribed spacer (ITS) regions of the nuclear rRNA gene operon. The new species and the new variety have a multiresistant antifungal profile, which includes high MICs of amphotericin B (geometric mean MIC, 1.18 mg/liter for C. haemulonii var. vulnera and 2 mg/liter for C. duobushaemulonii sp. nov) and cross-resistance to azole compounds. Identification of these species should be based on molecular methods, such as sequence analysis of ITS regions and matrix-assisted laser desorption ionization-time of flight mass spectrometry.

Journal ArticleDOI
TL;DR: This work describes a modification of a previously reported MALDI-TOF MS meropenem hydrolysis assay that was validated on 108 carbapenemase-producing members of the Enterobacteriaceae, two NDM-1-producing Acinetobacter baumannii isolates, and 35 carbAPenem-resistant enterobacteria producing no carbapanemase.
Abstract: Matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF MS) is a potentially useful tool for the detection of antimicrobial resistance, especially that conferred by β-lactamases. Here we describe a modification of a previously reported MALDI-TOF MS meropenem hydrolysis assay. The modified method was validated on 108 carbapenemase-producing members of the Enterobacteriaceae, two NDM-1-producing Acinetobacter baumannii isolates, and 35 carbapenem-resistant enterobacteria producing no carbapenemase. The detection of carbapenemases by MALDI-TOF MS seems to be a powerful, quick, and cost-effective method for microbiological laboratories.

Journal ArticleDOI
TL;DR: An evaluation of the accuracy, cost, and turnaround time of this method for 61 positive monomicrobial and 2 polymicrobial cultures representing 26 species shows that the use of MALDI-TOF for direct identification is accurate and should result in reduced turnaround time to identification.
Abstract: Matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry represents a revolution in the rapid identification of bacterial and fungal pathogens in the clinical microbiology laboratory. Recently, MALDI-TOF has been applied directly to positive blood culture bottles for the rapid identification of pathogens, leading to reductions in turnaround time and potentially beneficial patient impacts. The development of a commercially available extraction kit (Bruker Sepsityper) for use with the Bruker MALDI BioTyper has facilitated the processing required for identification of pathogens directly from positive from blood cultures. We report the results of an evaluation of the accuracy, cost, and turnaround time of this method for 61 positive monomicrobial and 2 polymicrobial cultures representing 26 species. The Bruker MALDI BioTyper with the Sepsityper gave a valid (score, >1.7) identification for 85.2% of positive blood cultures with no misidentifications. The mean reduction in turnaround time to identification was 34.3 h (P < 0.0001) in the ideal situation where MALDI-TOF was used for all blood cultures and 26.5 h in a more practical setting where conventional identification or identification from subcultures was required for isolates that could not be directly identified by MALDI-TOF. Implementation of a MALDI-TOF-based identification system for direct identification of pathogens from blood cultures is expected to be associated with a marginal increase in operating costs for most laboratories. However, the use of MALDI-TOF for direct identification is accurate and should result in reduced turnaround time to identification.

Journal ArticleDOI
TL;DR: In this paper, Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) was used to identify vanB-positive enterococcus faecium VRE from susceptible isolates.
Abstract: The control of vancomycin-resistant enterococci (VRE) has become an increasing burden on health care resources since their discovery over 20 years ago. Current techniques employed for their detection include time-consuming and laborious phenotypic methods or molecular methods requiring costly equipment and consumables and highly trained staff. An accurate, rapid diagnostic test has the ability to greatly reduce the spread of this organism, which has the ability to colonize patients for long periods, potentially even lifelong. Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) is a technology with the ability to identify organisms in seconds and has shown promise in the identification of other forms of antimicrobial resistance in other organisms. Here we show that MALDI-TOF MS is capable of rapidly and accurately identifying vanB-positive Enterococcus faecium VRE from susceptible isolates. Internal validation of the optimal model generated produced a sensitivity of 92.4% and a specificity of 85.2%. Prospective validation results, following incorporation into the routine laboratory work flow, demonstrated a greater sensitivity and specificity at 96.7% and 98.1%, respectively. In addition, the utilization of MALDI-TOF MS to determine the relatedness of isolates contributing to an outbreak is also demonstrated.

Journal ArticleDOI
TL;DR: This Compared the matrix-assisted laser desorption ionization (MALDI) Biotyper system with Sepsityper specimen processing to routine methods for the identification of microorganisms from 164 positive blood cultures found that Gram-negative isolates were more likely to produce acceptable confidence scores than Gram-positive isolates.
Abstract: Bloodstream infections are a leading cause of admissions to hospital intensive care units and carry a high mortality rate. Clinical outcome can be greatly improved by early effective antibiotic therapy; therefore, broad-spectrum antimicrobial therapy is often initiated when there is a clinical suspicion of bloodstream infection. Unfortunately, this method may not always be effective when dealing with inherently resistant organisms and can also result in iatrogenic infection and the development of resistant isolates. Rapid identification of the infecting organism may aid in choosing appropriate antimicrobial therapy, thereby reducing these potential adverse events. We compared the matrix-assisted laser desorption ionization (MALDI) Biotyper system with Sepsityper specimen processing (Bruker Daltonics, Billerica, MA) to routine methods for the identification of microorganisms from 164 positive blood cultures. The MALDI Biotyper/Sepsityper identified 85.5% of bacterial isolates directly from positive monomicrobial blood cultures with 97.6% concordance to genus and 94.1% concordance to species with routine identification methods. Gram-negative isolates were more likely to produce acceptable confidence scores (97.8%) than gram-positive isolates (80.0%); however, genus and species concordance with routine identification methods were similar in both groups. Reanalysis of collected spectra using modified blood culture-specific parameters resulted in an improved overall identification rate for gram-positive bacteria (89.0%). Median times to identification using the MALDI Biotyper/Sepsityper were 23 to 83 h faster than routine methods for gram-positive isolates and 34 to 51 h faster for gram-negative isolates.

Journal ArticleDOI
TL;DR: The results indicate that the antigenic epitopes of RVA strains contained in the vaccines differ substantially from those of the currently circulating R VA strains in Belgium, which might result in selection for strains that escape the RVA neutralizing-antibody pressure induced by vaccines.
Abstract: Two live-attenuated rotavirus group A (RVA) vaccines, Rotarix (G1P[8]) and RotaTeq (G1-G4, P[8]), have been successfully introduced in many countries worldwide, including Belgium. The parental RVA strains used to generate the vaccines were isolated more than 20 years ago in France (G4 parental strain in RotaTeq) and the United States (all other parental strains). At present, little is known about the relationship between currently circulating human RVAs and the vaccine strains. In this study, we determined sequences for the VP7 and VP4 outer capsid proteins of representative G1P[8], G2P[4], G3P[8], G4P[8], G9P[8], and G12P[8] RVAs circulating in Belgium during 2007 to 2009. The analyses showed that multiple amino acid differences existed between the VP7 and VP4 antigenic epitopes of the vaccine viruses and the Belgian isolates, regardless of their G and P genotypes. However, the highest variability was observed among the circulating G1P[8] RVA strains and the G1 and P[8] components of both RVA vaccines. In particular, RVA strains of the P[8] lineage 4 (OP354-like) showed a significant number of amino acid differences with the P[8] VP4 of both vaccines. In addition, the circulating Belgian G3 RVA strains were found to possibly possess an extra N-linked glycosylation site compared to the G3 RVA vaccine strain of RotaTeq. These results indicate that the antigenic epitopes of RVA strains contained in the vaccines differ substantially from those of the currently circulating RVA strains in Belgium. Over time, these differences might result in selection for strains that escape the RVA neutralizing-antibody pressure induced by vaccines.

Journal ArticleDOI
TL;DR: An updated multiplex PCR strategy was developed to assign Escherichia coli isolates rapidly to major phylogenetic groups and showed improved congruence with multilocus sequence typing data, thereby increasing sensitivity and reliability.
Abstract: Using data from whole-genome projects, an updated multiplex PCR strategy was developed to assign Escherichia coli isolates rapidly to major phylogenetic groups. This assay accommodates sequence variations detected within target sequences, thereby increasing sensitivity and reliability. It was validated using 185 isolates of known sequence types and showed improved congruence with multilocus sequence typing data.

Journal ArticleDOI
TL;DR: A multilocus sequence typing (MLST) approach employing the alleles of 7 genes was used to investigate the phylogenetic relationship of 325 Cronobacter species isolates and found C. sakazakii sequence type 4 was the predominant sequence type of cerebral spinal fluid isolates from cases of meningitis.
Abstract: Cronobacter (previously known as Enterobacter sakazakii) is a diverse bacterial genus consisting of seven species: C. sakazakii, C. malonaticus, C. turicensis, C. universalis, C. muytjensii, C. dublinensis, and C. condimenti. In this study, we have used a multilocus sequence typing (MLST) approach employing the alleles of 7 genes (atpD, fusA, glnS, gltB, gyrB, infB, and ppsA; total length, 3,036 bp) to investigate the phylogenetic relationship of 325 Cronobacter species isolates. Strains were chosen on the basis of their species, geographic and temporal distribution, source, and clinical outcome. The earliest strain was isolated from milk powder in 1950, and the earliest clinical strain was isolated in 1953. The existence of seven species was supported by MLST. Intraspecific variation ranged from low diversity in C. sakazakii to extensive diversity within some species, such as C. muytjensii and C. dublinensis, including evidence of gene conversion between species. The predominant species from clinical sources was found to be C. sakazakii. C. sakazakii sequence type 4 (ST4) was the predominant sequence type of cerebral spinal fluid isolates from cases of meningitis.

Journal ArticleDOI
TL;DR: The time-consuming, error-prone, and dreadfully boring manual sequence analysis step is replaced with a fully automated system without compromising the accuracy of reported HIV drug resistance data.
Abstract: Genotypic HIV drug resistance testing is routinely used to guide clinical decisions. While genotyping methods can be standardized, a slow, labor-intensive, and subjective manual sequence interpretation step is required. We therefore performed external validation of our custom software RECall, a fully automated sequence analysis pipeline. HIV-1 drug resistance genotyping was performed on 981 clinical samples at the Stanford Diagnostic Virology Laboratory. Sequencing trace files were first interpreted manually by a laboratory technician and subsequently reanalyzed by RECall, without intervention. The relative performances of the two methods were assessed by determination of the concordance of nucleotide base calls, identification of key resistance-associated substitutions, and HIV drug resistance susceptibility scoring by the Stanford Sierra algorithm. RECall is freely available at http://pssm.cfenet.ubc.ca. In total, 875 of 981 sequences were analyzed by both human and RECall interpretation. RECall analysis required minimal hands-on time and resulted in a 25-fold improvement in processing speed (∼150 technician-hours versus ∼6 computation-hours). Excellent concordance was obtained between human and automated RECall interpretation (99.7% agreement for >1,000,000 bases compared). Nearly all discordances (99.4%) were due to nucleotide mixtures being called by one method but not the other. Similarly, 98.6% of key antiretroviral resistance-associated mutations observed were identified by both methods, resulting in 98.5% concordance of resistance susceptibility interpretations. This automated sequence analysis tool provides both standardization of analysis and a significant improvement in data workflow. The time-consuming, error-prone, and dreadfully boring manual sequence analysis step is replaced with a fully automated system without compromising the accuracy of reported HIV drug resistance data.

Journal ArticleDOI
TL;DR: Results show cross-reactivity of Fusarium spp.
Abstract: Nine of 11 hematological patients with disseminated/deep-seated Fusarium infection tested at least twice for Aspergillus galactomannan (GM) had repeated positive results in the absence of Aspergillus isolation in culture. The centrifuged supernatants of 12 Fusarium isolates were tested by a GM enzyme-linked immunosorbent assay (EIA). All the isolates produced positive reactions when tested undiluted. These results show cross-reactivity of Fusarium spp. with Aspergillus GM that may constitute a drawback with respect to the specificity of the Platelia EIA.

Journal ArticleDOI
TL;DR: Invasive pulmonary aspergillosis (IPA) is frequent and often fatal in immunosuppressed patients as mentioned in this paper, and timely diagnosis of IPA improves survival but is difficult to make.
Abstract: Invasive pulmonary aspergillosis (IPA) is frequent and often fatal in immunosuppressed patients. Timely diagnosis of IPA improves survival but is difficult to make. We examined the analytical and clinical validity of galactomannan (GM) testing of bronchoalveolar lavage (BAL) fluid in diagnosing IPA in a mixed population by retrospectively reviewing records of 251 consecutive at-risk patients for whom BAL fluid GM testing was ordered. The performance of the enzyme immunoassay was evaluated by using a range of index cutoffs to define positivity. Three samples were associated with proven IPA, 56 were associated with probable IPA, 63 were associated with possible invasive fungal disease (IFD), and 129 were associated with no IFD. Using a BAL fluid GM index of ≥0.8 (optimal optical density [OD] index cutoff identified by a receiver operating characteristic curve), the sensitivity in diagnosing proven and probable IPA was 86.4%, and the specificity was 90.7%. At this cutoff, positive and negative predictive values were 81% and 93.6%, respectively. However, an OD index value of ≥3.0 corresponded to a 100% specificity, thus ruling the disease in, irrespective of the pretest probability. Conversely, an OD index cutoff of <0.5 corresponded to a high sensitivity, virtually always ruling the disease out. For all values in between, the posttest probability of IPA depends largely on the prevalence of disease in the at-risk population and the likelihood ratio of the OD index value. Detection of GM in BAL fluid samples of patients at risk of IPA has an excellent diagnostic accuracy provided results are interpreted in parallel with clinico-radiological findings and pretest probabilities.