scispace - formally typeset
Search or ask a question

Showing papers in "Journal of Synchrotron Radiation in 2015"


Journal ArticleDOI
TL;DR: DAWN is a generic data analysis software platform developed for use at synchrotron beamlines for data visualization and analysis that is suitable for use in a range of scientific and engineering applications.
Abstract: Synchrotron light source facilities worldwide generate terabytes of data in numerous incompatible data formats from a wide range of experiment types. The Data Analysis WorkbeNch (DAWN) was developed to address the challenge of providing a single visualization and analysis platform for data from any synchrotron experiment (including single-crystal and powder diffraction, tomography and spectroscopy), whilst also being sufficiently extensible for new specific use case analysis environments to be incorporated (e.g. ARPES, PEEM). In this work, the history and current state of DAWN are presented, with two case studies to demonstrate specific functionality. The first is an example of a data processing and reduction problem using the generic tools, whilst the second shows how these tools can be targeted to a specific scientific area.

353 citations


Journal ArticleDOI
TL;DR: The macromolecular crystallography beamline MX1 at the Australian Synchrotron is described.
Abstract: MX1 is a bending-magnet crystallography beamline at the 3 GeV Australian Synchrotron. The beamline delivers hard X-rays in the energy range from 8 to 18 keV to a focal spot at the sample position of 120 µm FWHM. The beamline endstation and ancillary equipment facilitate local and remote access for both chemical and biological macromolecular crystallography. Here, the design of the beamline and endstation are discussed. The beamline has enjoyed a full user program for the last seven years and scientific highlights from the user program are also presented.

305 citations


Journal ArticleDOI
TL;DR: JEEP is a high-energy (50–150 keV) multi-purpose beamline offering polychromatic and monochromatic modes, enabling in situ studies using radiography, tomography, energy-dispersive diffraction, monochROMatic and white-beam two-dimensional diffraction/scattering and small-angle X-ray scattering.
Abstract: I12 is the Joint Engineering, Environmental and Processing (JEEP) beamline, constructed during Phase II of the Diamond Light Source. I12 is located on a short (5 m) straight section of the Diamond storage ring and uses a 4.2 T superconducting wiggler to provide polychromatic and monochromatic X-rays in the energy range 50–150 keV. The beam energy enables good penetration through large or dense samples, combined with a large beam size (1 mrad horizontally × 0.3 mrad vertically). The beam characteristics permit the study of materials and processes inside environmental chambers without unacceptable attenuation of the beam and without the need to use sample sizes which are atypically small for the process under study. X-ray techniques available to users are radiography, tomography, energy-dispersive diffraction, monochromatic and white-beam two-dimensional diffraction/scattering and small-angle X-ray scattering. Since commencing operations in November 2009, I12 has established a broad user community in materials science and processing, chemical processing, biomedical engineering, civil engineering, environmental science, palaeontology and physics.

212 citations


Journal ArticleDOI
TL;DR: A description of the X-ray Pump–Probe (XPP) instrument at the Linac Coherent Light Source is presented and recent scientific highlights illustrate the versatility and the time-resolved X-rays diffraction and spectroscopy capabilities of the instrument.
Abstract: The X-ray Pump–Probe instrument achieves femtosecond time-resolution with hard X-ray methods using a free-electron laser source. It covers a photon energy range of 4–24 keV. A femtosecond optical laser system is available across a broad spectrum of wavelengths for generating transient states of matter. The instrument is designed to emphasize versatility and the scientific goals encompass ultrafast physical, chemical and biological processes involved in the transformation of matter and transfer of energy at the atomic scale.

165 citations


Journal ArticleDOI
TL;DR: By providing the capabilities for high-resolution, high-energy and time-resolved powder X-ray diffraction, beamline P02.1 is a versatile tool to tackle various problems in materials science, crystallography and chemistry.
Abstract: Powder X-ray diffraction techniques largely benefit from the superior beam quality provided by high-brilliance synchrotron light sources in terms of photon flux and angular resolution. The High Resolution Powder Diffraction Beamline P02.1 at the storage ring PETRA III (DESY, Hamburg, Germany) combines these strengths with the power of high-energy X-rays for materials research. The beamline is operated at a fixed photon energy of 60 keV (0.207 A wavelength). A high-resolution monochromator generates the highly collimated X-ray beam of narrow energy bandwidth. Classic crystal structure determination in reciprocal space at standard and non-ambient conditions are an essential part of the scientific scope as well as total scattering analysis using the real space information of the pair distribution function. Both methods are complemented by in situ capabilities with time-resolution in the sub-second regime owing to the high beam intensity and the advanced detector technology for high-energy X-rays. P02.1's efficiency in solving chemical and crystallographic problems is illustrated by presenting key experiments that were carried out within these fields during the early stage of beamline operation.

165 citations


Journal ArticleDOI
TL;DR: Recent scientific highlights illustrate the femtosecond crystallography, high power density and extreme matter capabilities of the CXI instrument at the Linac Coherent Light Source.
Abstract: The Coherent X-ray Imaging (CXI) instrument specializes in hard X-ray, in-vacuum, high power density experiments in all areas of science. Two main sample chambers, one containing a 100 nm focus and one a 1 µm focus, are available, each with multiple diagnostics, sample injection, pump–probe and detector capabilities. The flexibility of CXI has enabled it to host a diverse range of experiments, from biological to extreme matter.

151 citations


Journal ArticleDOI
TL;DR: A performance description of the Extreme Conditions Beamline (ECB, P02.2) at PETRA III that is optimized for micro-diffraction at simultaneous high pressure and high and low temperatures created in different diamond anvil cells environments is provided.
Abstract: A detailed description is presented of the Extreme Conditions Beamline P02.2 for micro X-ray diffraction studies of matter at simultaneous high pressure and high/low temperatures at PETRA III, in Hamburg, Germany. This includes performance of the X-ray optics and instrumental resolution as well as an overview of the different sample environments available for high-pressure studies in the diamond anvil cell. Particularly emphasized are the high-brilliance and high-energy X-ray diffraction capabilities of the beamline in conjunction with the use of fast area detectors to conduct time-resolved compression studies in the millisecond time regime. Finally, the current capability of the Extreme Conditions Science Infrastructure to support high-pressure research at the Extreme Conditions Beamline and other PETRA III beamlines is described.

134 citations


Journal ArticleDOI
TL;DR: The BM23 beamline at the ESRF offers high-signal-to-noise ratio EXAFS in a large energy range (5–75 keV), continuous energy scanning for quick-EXAFS on the second timescale and a micro-XAS station delivering a spot size of 4‵m × 4 µm FWHM.
Abstract: BM23 is the general-purpose EXAFS bending-magnet beamline at the ESRF, replacing the former BM29 beamline in the framework of the ESRF upgrade. Its mission is to serve the whole XAS user community by providing access to a basic service in addition to the many specialized instruments available at the ESRF. BM23 offers high signal-to-noise ratio EXAFS in a large energy range (5–75 keV), continuous energy scanning for quick-EXAFS on the second timescale and a micro-XAS station delivering a spot size of 4 µm × 4 µm FWHM. It is a user-friendly facility featuring a high degree of automation, online EXAFS data reduction and a flexible sample environment.

127 citations


Journal ArticleDOI
TL;DR: MASSIF-1 (ID30A-1) is a new beamline dedicated to the completely automatic characterization and data collection from crystals of biological macromolecules.
Abstract: MASSIF-1 (ID30A-1) is an ESRF undulator beamline operating at a fixed wavelength of 0.969 A (12.8 keV) that is dedicated to the completely automatic characterization of and data collection from crystals of biological macromolecules. The first of the ESRF Upgrade MASSIF beamlines to be commissioned, it has been open since September 2014, providing a unique automated data collection service to academic and industrial users. Here, the beamline characteristics and details of the new service are outlined.

122 citations


Journal ArticleDOI
TL;DR: A new X-ray absorption fine-structure (XAFS) spectroscopy beamline for fundamental and applied catalysis research, called XAFCA, has been built by the Institute of Chemical and Engineering Sciences, and the Singapore Synchrotron Light Source.
Abstract: A new X-ray absorption fine-structure (XAFS) spectroscopy beamline for fundamental and applied catalysis research, called XAFCA, has been built by the Institute of Chemical and Engineering Sciences, and the Singapore Synchrotron Light Source. XAFCA covers the photon energy range from 1.2 to 12.8 keV, making use of two sets of monochromator crystals, an Si (111) crystal for the range from 2.1 to 12.8 keV and a KTiOPO4 crystal [KTP (011)] for the range between 1.2 and 2.8 keV. Experiments can be carried out in the temperature range from 4.2 to 1000 K and pressures up to 30 bar for catalysis research. A safety system has been incorporated, allowing the use of flammable and toxic gases such as H2 and CO.

120 citations


Journal ArticleDOI
TL;DR: An overview of SACLA operating as a user facility and the updated status of the light source and the beamline is summarized.
Abstract: In March 2012, SACLA started user operations of the first compact X-ray free-electron laser (XFEL) facility. SACLA has been routinely providing users with stable XFEL light over a wide photon energy range from 4 to 15 keV and an ultrafast pulse duration below 10 fs. The facility supports experimental activities in broad fields by offering high-quality X-ray optics and diagnostics, as well as reliable multiport charge-coupled-device detectors, with flexible experimental configurations. A two-stage X-ray focusing system was developed that enables the highest intensity of 1020 W cm−2. Key scientific results published in 2013 and 2014 in diverse fields are reviewed. The main experimental systems developed for these applications are summarized. A perspective on the facility upgrade is presented.

Journal ArticleDOI
TL;DR: Various practical approaches are evaluated that users can implement to limit radiation damage at the P12 beamline to maximize the chances of collecting quality data from radiation sensitive samples.
Abstract: Radiation damage is the general curse of structural biologists who use synchrotron small-angle X-ray scattering (SAXS) to investigate biological macromolecules in solution. The EMBL-P12 biological SAXS beamline located at the PETRAIII storage ring (DESY, Hamburg, Germany) caters to an extensive user community who integrate SAXS into their diverse structural biology programs. The high brilliance of the beamline [5.1 × 1012 photons s−1, 10 keV, 500 (H) µm × 250 (V) µm beam size at the sample position], combined with automated sample handling and data acquisition protocols, enable the high-throughput structural characterization of macromolecules in solution. However, considering the often-significant resources users invest to prepare samples, it is crucial that simple and effective protocols are in place to limit the effects of radiation damage once it has been detected. Here various practical approaches are evaluated that users can implement to limit radiation damage at the P12 beamline to maximize the chances of collecting quality data from radiation sensitive samples.

Journal ArticleDOI
TL;DR: The performance of MISTRAL is reported, the soft X-ray transmission microscopy beamline at the ALBA light source (Barcelona, Spain) which is primarily dedicated to cryo softX-ray tomography (cryo-SXT) for three-dimensional visualization of whole unstained cells at spatial resolutions down to 30 nm (half pitch).
Abstract: The performance of MISTRAL is reported, the soft X-ray transmission microscopy beamline at the ALBA light source (Barcelona, Spain) which is primarily dedicated to cryo soft X-ray tomography (cryo-SXT) for three-dimensional visualization of whole unstained cells at spatial resolutions down to 30 nm (half pitch). Short acquisition times allowing for high-throughput and correlative microscopy studies have promoted cryo-SXT as an emerging cellular imaging tool for structural cell biologists bridging the gap between optical and electron microscopy. In addition, the beamline offers the possibility of imaging magnetic domains in thin magnetic films that are illustrated here with an example.

Journal ArticleDOI
TL;DR: The GALAXIES beamline at the SOLEIL synchrotron is dedicated to inelastic X-ray scattering (IXS) and photoelectron spectroscopy (HAXPES) in the 2.3-12 keV hard X-rays range, offering powerful complementary methods of characterization of materials with bulk sensitivity, chemical and orbital selectivity, resonant enhancement and high resolving power.
Abstract: The GALAXIES beamline at the SOLEIL synchrotron is dedicated to inelastic X-ray scattering (IXS) and photoelectron spectroscopy (HAXPES) in the 2.3–12 keV hard X-ray range. These two techniques offer powerful complementary methods of characterization of materials with bulk sensitivity, chemical and orbital selectivity, resonant enhancement and high resolving power. After a description of the beamline components and endstations, the beamline capabilities are demonstrated through a selection of recent works both in the solid and gas phases and using either IXS or HAXPES approaches. Prospects for studies on liquids are discussed.

Journal ArticleDOI
TL;DR: A description of the Matter in Extreme Conditions instrument at the Linac Coherent Light Source is given and recent scientific highlights illustrate phase-contrast imaging of shock waves, X-ray Thomson scattering andX-ray diffraction of shocked materials.
Abstract: The LCLS beam provides revolutionary capabilities for studying the transient behavior of matter in extreme conditions. The particular strength of the Matter in Extreme Conditions instrument is that it combines the unique LCLS beam with high-power optical laser beams, and a suite of dedicated diagnostics tailored for this field of science. In this paper an overview of the beamline, the capabilities of the instrumentation, and selected highlights of experiments and commissioning results are presented.

Journal ArticleDOI
TL;DR: In this article, the effects of local damage in serial femtosecond crystallography (SFX), Clostridium ferredoxin was used as a model system, and the electron density maps calculated from high-dose SFX and synchrotron data showed peaks at the iron positions of the clusters, indicative of decrease of atomic scattering factors due to ionization.
Abstract: Proteins that contain metal cofactors are expected to be highly radiation sensitive since the degree of X-ray absorption correlates with the presence of high-atomic-number elements and X-ray energy. To explore the effects of local damage in serial femtosecond crystallography (SFX), Clostridium ferredoxin was used as a model system. The protein contains two [4Fe–4S] clusters that serve as sensitive probes for radiation-induced electronic and structural changes. High-dose room-temperature SFX datasets were collected at the Linac Coherent Light Source of ferredoxin microcrystals. Difference electron density maps calculated from high-dose SFX and synchrotron data show peaks at the iron positions of the clusters, indicative of decrease of atomic scattering factors due to ionization. The electron density of the two [4Fe–4S] clusters differs in the FEL data, but not in the synchrotron data. Since the clusters differ in their detailed architecture, this observation is suggestive of an influence of the molecular bonding and geometry on the atomic displacement dynamics following initial photoionization. The experiments are complemented by plasma code calculations.

Journal ArticleDOI
TL;DR: The performance of the spectroscopic LEEM-PEEM experimental station at the ALBA Synchrotron is presented: XPEEM lateral resolution down to better than 20 nm, electron energy resolution below 0.15 eV, and excellent long-term stability.
Abstract: The spectroscopic LEEM-PEEM experimental station at the CIRCE helical undulator beamline, which started user operation at the ALBA Synchrotron Light Facility in 2012, is presented. This station, based on an Elmitec LEEM III microscope with electron imaging energy analyzer, permits surfaces to be imaged with chemical, structural and magnetic sensitivity down to a lateral spatial resolution better than 20 nm with X-ray excited photoelectrons and 10 nm in LEEM and UV-PEEM modes. Rotation around the surface normal and application of electric and (weak) magnetic fields are possible in the microscope chamber. In situ surface preparation capabilities include ion sputtering, high-temperature flashing, exposure to gases, and metal evaporation with quick evaporator exchange. Results from experiments in a variety of fields and imaging modes will be presented in order to illustrate the ALBA XPEEM capabilities.

Journal ArticleDOI
TL;DR: An overview of area detectors developed for use at the Linac Coherent Light Source (LCLS) with particular emphasis on their impact on science is offered.
Abstract: Free-electron lasers (FELs) present new challenges for camera development compared with conventional light sources. At SLAC a variety of technologies are being used to match the demands of the Linac Coherent Light Source (LCLS) and to support a wide range of scientific applications. In this paper an overview of X-ray detector design requirements at FELs is presented and the various cameras in use at SLAC are described for the benefit of users planning experiments or analysts looking at data. Features and operation of the CSPAD camera, which is currently deployed at LCLS, are discussed, and the ePix family, a new generation of cameras under development at SLAC, is introduced.

Journal ArticleDOI
TL;DR: The results of recent measurements on copper and on several tetrahedral semiconductors are here critically compared and some properties of the MSRDs are discussed, such as the dependence of correlation, force constants and vibrational anisotropy on crystal structure and bond ionicity as well as the relative merits of the correlated Debye and Einstein models.
Abstract: The effects of structural and vibrational disorder on the EXAFS signals are parameterized in terms of the Debye Waller (DW) factor. Here the vibrational contribution is addressed, which for most systems can be singled out by studying the temperature dependence of the EXAFS DW factor, which corresponds to a good accuracy to the parallel mean square relative displacement (MSRD) around the inter-atomic equilibrium distance. By comparing the first-shell EXAFS thermal expansion with the crystallographic thermal expansion one can evaluate the perpendicular MSRD. The results of recent measurements on copper and on several tetrahedral semiconductors are here critically compared and some properties of the MSRDs are discussed, such as the dependence of correlation, force constants and vibrational anisotropy on crystal structure and bond ionicity as well as the relative merits of the correlated Debye and Einstein models. The anharmonic contribution to the parallel MSRD of CdTe has been evaluated and a quasi-harmonic analysis has been attempted, leading to an estimation of the bond Gruneisen parameter.

Journal ArticleDOI
TL;DR: A compound optical system for coherent focusing and imaging at the nanoscale is reported, realised by high-gain fixed-curvature elliptical mirrors in combination with X-ray waveguide optics or different cleaning apertures.
Abstract: A compound optical system for coherent focusing and imaging at the nanoscale is reported, realised by high-gain fixed-curvature elliptical mirrors in combination with X-ray waveguide optics or different cleaning apertures. The key optical concepts are illustrated, as implemented at the Gottingen Instrument for Nano-Imaging with X-rays (GINIX), installed at the P10 coherence beamline of the PETRA III storage ring at DESY, Hamburg, and examples for typical applications in biological imaging are given. Characteristic beam configurations with the recently achieved values are also described, meeting the different requirements of the applications, such as spot size, coherence or bandwidth. The emphasis of this work is on the different beam shaping, filtering and characterization methods.

Journal ArticleDOI
TL;DR: A summarising review of data treatment for non-resonant inelastic X-ray scattering data from modern synchrotron-based multi-analyzer spectrometers.
Abstract: A compilation of procedures for planning and performing X-ray Raman scattering (XRS) experiments and analyzing data obtained from them is presented. In particular, it is demonstrated how to predict the overall shape of the spectra, estimate detection limits for dilute samples, and how to normalize the recorded spectra to absolute units. In addition, methods for processing data from multiple-crystal XRS spectrometers with imaging capability are presented, including a super-resolution method that can be used for direct tomography using XRS spectra as the contrast. An open-source software package with these procedures implemented is also made available.

Journal ArticleDOI
TL;DR: Correcting to the full-spot equivalent, relying on both a physical model for crystal disorder and postrefinement of the crystal orientation, improves the electron density map in serial crystallography.
Abstract: Serial crystallography, using either femtosecond X-ray pulses from free-electron laser sources or short synchrotron-radiation exposures, has the potential to reveal metalloprotein structural details while minimizing damage processes. However, deriving a self-consistent set of Bragg intensities from numerous still-crystal exposures remains a difficult problem, with optimal protocols likely to be quite different from those well established for rotation photography. Here several data processing issues unique to serial crystallography are examined. It is found that the limiting resolution differs for each shot, an effect that is likely to be due to both the sample heterogeneity and pulse-to-pulse variation in experimental conditions. Shots with lower resolution limits produce lower-quality models for predicting Bragg spot positions during the integration step. Also, still shots by their nature record only partial measurements of the Bragg intensity. An approximate model that corrects to the full-spot equivalent (with the simplifying assumption that the X-rays are monochromatic) brings the distribution of intensities closer to that expected from an ideal crystal, and improves the sharpness of anomalous difference Fourier peaks indicating metal positions.

Journal ArticleDOI
TL;DR: The present status of the Linac Coherent Light Source as a user facility is presented and opportunities and challenges as well as the scientific impact of X-ray free-electron lasers are discussed.
Abstract: The Linac Coherent Light Source (LCLS) at the SLAC National Accelerator Laboratory was the first hard X-ray free-electron laser (FEL) to operate as a user facility After five years of operation, LCLS is now a mature FEL user facility Our personal views about opportunities and challenges inherent to these unique light sources are discussed

Journal ArticleDOI
TL;DR: An experimental platform for serial femtosecond crystallography using an X-ray free-electron laser and its applications at SACLA are described.
Abstract: An experimental system for serial femtosecond crystallography using an X-ray free-electron laser (XFEL) has been developed. It basically consists of a sample chamber, fluid injectors and a two-dimensional detector. The chamber and the injectors are operated under helium atmosphere at 1 atm. The ambient pressure operation facilitates applications to fluid samples. Three kinds of injectors are employed to feed randomly oriented crystals in aqueous solution or highly viscous fluid. Experiments on lysozyme crystals were performed by using the 10 keV XFEL of the SPring-8 Angstrom Compact free-electron LAser (SACLA). The structure of model protein lysozyme from 1 µm crystals at a resolution of 2.4 A was obtained.

Journal ArticleDOI
TL;DR: The optical concept and the first measured performance of the Nanoscopium beamline is described followed by the hierarchical length-scale multi-technique imaging experiments performed with dwell times down to 3 ms per pixel.
Abstract: The Nanoscopium 155 m-long beamline of Synchrotron Soleil is dedicated to scanning hard X-ray nanoprobe techniques. Nanoscopium aims to reach ≤100 nm resolution in the 5–20 keV energy range for routine user experiments. The beamline design tackles the tight stability requirements of such a scanning nanoprobe by creating an overfilled secondary source, implementing all horizontally reflecting main beamline optics, applying high mechanical stability equipment and constructing a dedicated high-stability building envelope. Multi-technique scanning imaging and tomography including X-ray fluorescence spectrometry and spectro-microscopy, absorption, differential phase and dark-field contrasts are implemented at the beamline in order to provide simultaneous information on the elemental distribution, speciation and sample morphology. This paper describes the optical concept and the first measured performance of the Nanoscopium beamline followed by the hierarchical length-scale multi-technique imaging experiments performed with dwell times down to 3 ms per pixel.

Journal ArticleDOI
TL;DR: In this work a microscopy system designed and constructed to accommodate multilayer Laue lenses as nanofocusing optics is presented and has been thoroughly characterized in terms of resolution and stability followed by imaging experiments at a synchrotron facility.
Abstract: Hard X-ray microscopy is a prominent tool suitable for nanoscale-resolution non-destructive imaging of various materials used in different areas of science and technology With an ongoing effort to push the 2D/3D imaging resolution down to 10 nm in the hard X-ray regime, both the fabrication of nano-focusing optics and the stability of the microscope using those optics become extremely challenging In this work a microscopy system designed and constructed to accommodate multilayer Laue lenses as nanofocusing optics is presented The developed apparatus has been thoroughly characterized in terms of resolution and stability followed by imaging experiments at a synchrotron facility Drift rates of ∼2 nm h−1 accompanied by 13 nm × 33 nm imaging resolution at 118 keV are reported

Journal ArticleDOI
TL;DR: A description of the Atomic, Molecular and Optical Sciences (AMO) instrument at the Linac Coherent Light Source is presented and recent scientific highlights illustrate the imaging, time-resolved spectroscopy and high-power density capabilities of the AMO instrument.
Abstract: The Atomic, Molecular and Optical Science (AMO) instrument at the Linac Coherent Light Source (LCLS) provides a tight soft X-ray focus into one of three experimental endstations. The flexible instrument design is optimized for studying a wide variety of phenomena requiring peak intensity. There is a suite of spectrometers and two photon area detectors available. An optional mirror-based split-and-delay unit can be used for X-ray pump–probe experiments. Recent scientific highlights illustrate the imaging, time-resolved spectroscopy and high-power density capabilities of the AMO instrument.

Journal ArticleDOI
TL;DR: The article is aiming to demonstrate how the beamline performances have been specifically optimized to fulfill the specific requirements of a soft X-ray microscopy beamline in terms of flux, resolution, beam size etc.
Abstract: The HERMES beamline (High Efficiency and Resolution beamline dedicated to X-ray Microscopy and Electron Spectroscopy), built at Synchrotron SOLEIL (Saint-Auban, France), is dedicated to soft X-ray microscopy. The beamline combines two complementary microscopy methods: XPEEM (X-ray Photo Emitted Electron Microscopy) and STXM (Scanning Transmission X-ray Microscopy) with an aim to reach spatial resolution below 20 nm and to fully exploit the local spectroscopic capabilities of the two microscopes. The availability of the two methods within the same beamline enables the users to select the appropriate approach to study their specific case in terms of sample environment, spectroscopy methods, probing depth etc. In this paper a general description of the beamline and its design are presented. The performance and specifications of the beamline will be reviewed in detail. Moreover, the article is aiming to demonstrate how the beamline performances have been specifically optimized to fulfill the specific requirements of a soft X-ray microscopy beamline in terms of flux, resolution, beam size etc. Special attention has been dedicated to overcome some limiting and hindering problems that are usually encountered on soft X-ray beamlines such as carbon contamination, thermal stability and spectral purity.

Journal ArticleDOI
TL;DR: CDApps software at Diamond B23 SRCD beamline is presented and new CDApps software for beamline diagnostics is presented.
Abstract: The B23 Circular Dichroism beamline at Diamond Light Source has been operational since 2009 and has seen visits from more than 200 user groups, who have generated large amounts of data. Based on the experience of overseeing the users' progress at B23, four key areas requiring the most assistance are identified: planning of experiments and note-keeping; designing titration experiments; processing and analysis of the collected data; and production of experimental reports. To streamline these processes an integrated software package has been developed and made available for the users. The subsequent article summarizes the main features of the software.

Journal ArticleDOI
TL;DR: An approach to high-resolution X-ray emission spectroscopy that uses a microcalorimeter detector array of superconducting transition-edge sensors (TESs) is updates and TES arrays are discussed and compared with conventional methods, and it is shown under which circumstances they are superior.
Abstract: X-ray emission spectroscopy (XES) is a powerful element-selective tool to analyze the oxidation states of atoms in complex compounds, determine their electronic configuration, and identify unknown compounds in challenging environments. Until now the low efficiency of wavelength-dispersive X-ray spectrometer technology has limited the use of XES, especially in combination with weaker laboratory X-ray sources. More efficient energy-dispersive detectors have either insufficient energy resolution because of the statistical limits described by Fano or too low counting rates to be of practical use. This paper updates an approach to high-resolution X-ray emission spectroscopy that uses a microcalorimeter detector array of superconducting transition-edge sensors (TESs). TES arrays are discussed and compared with conventional methods, and shown under which circumstances they are superior. It is also shown that a TES array can be integrated into a table-top time-resolved X-ray source and a soft X-ray synchrotron beamline to perform emission spectroscopy with good chemical sensitivity over a very wide range of energies.