Showing papers in "Lab on a Chip in 2011"


Journal ArticleDOI
TL;DR: A unique combination of fluid dynamic effects in a microfluidic system is demonstrated to demonstrate high-throughput continuous label-free cell classification and enrichment based on cell size and deformability, enabling off-chip sample collection without significant gene expression changes.
Abstract: The ability to detect and isolate rare target cells from heterogeneous samples is in high demand in cell biology research, immunology, tissue engineering and medicine. Techniques allowing label-free cell enrichment or detection are especially important to reduce the complexity and costs towards clinical applications. Single-cell deformability has recently been recognized as a unique label-free biomarker for cell phenotype with implications for assessment of cancer invasiveness. Using a unique combination of fluid dynamic effects in a microfluidic system, we demonstrate high-throughput continuous label-free cell classification and enrichment based on cell size and deformability. The system takes advantage of a balance between deformability-induced and inertial lift forces as cells travel in a microchannel flow. Particles and droplets with varied elasticity and viscosity were found to have separate lateral dynamic equilibrium positions due to this balance of forces. We applied this system to successfully classify various cell types using cell size and deformability as distinguishing markers. Furthermore, using differences in dynamic equilibrium positions, we adapted the system to conduct passive, label-free and continuous cell enrichment based on these markers, enabling off-chip sample collection without significant gene expression changes. The presented method has practical potential for high-throughput deformability measurements and cost-effective cell separation to obtain viable target cells of interest in cancer research, immunology, and regenerative medicine.

575 citations


Journal ArticleDOI
TL;DR: The technique enabled the determination of mutant allelic specific imbalance (MASI) in several cancer cell-lines and the precise quantification of a mutated KRAS gene in the presence of a 200,000-fold excess of unmutated KRAS genes.
Abstract: Somatic mutations within tumoral DNA can be used as highly specific biomarkers to distinguish cancer cells from their normal counterparts. These DNA biomarkers are potentially useful for the diagnosis, prognosis, treatment and follow-up of patients. In order to have the required sensitivity and specificity to detect rare tumoral DNA in stool, blood, lymph and other patient samples, a simple, sensitive and quantitative procedure to measure the ratio of mutant to wild-type genes is required. However, techniques such as dual probe TaqMan® assays and pyrosequencing, while quantitative, cannot detect less than ∼1% mutant genes in a background of non-mutated DNA from normal cells. Here we describe a procedure allowing the highly sensitive detection of mutated DNA in a quantitative manner within complex mixtures of DNA. The method is based on using a droplet-based microfluidic system to perform digital PCR in millions of picolitre droplets. Genomic DNA (gDNA) is compartmentalized in droplets at a concentration of less than one genome equivalent per droplet together with two TaqMan®probes, one specific for the mutant and the other for the wild-type DNA, which generate green and red fluorescent signals, respectively. After thermocycling, the ratio of mutant to wild-type genes is determined by counting the ratio of green to red droplets. We demonstrate the accurate and sensitive quantification of mutated KRAS oncogene in gDNA. The technique enabled the determination of mutant allelic specific imbalance (MASI) in several cancer cell-lines and the precise quantification of a mutated KRASgene in the presence of a 200 000-fold excess of unmutated KRASgenes. The sensitivity is only limited by the number of droplets analyzed. Furthermore, by one-to-one fusion of drops containing gDNA with any one of seven different types of droplets, each containing a TaqMan®probe specific for a different KRAS mutation, or wild-type KRAS, and an optical code, it was possible to screen the six common mutations in KRAScodon 12 in parallel in a single experiment.

539 citations


Journal ArticleDOI
TL;DR: The design of a "heart on a chip" that exploits muscular thin film technology--biohybrid constructs of an engineered, anisotropic ventricular myocardium on an elastomeric thin film--to measure contractility, combined with a quantification of action potential propagation, and cytoskeletal architecture in multiple tissues in the same experiment is reported.
Abstract: Traditionally, muscle physiology experiments require multiple tissue samples to obtain morphometric, electrophysiological, and contractility data. Furthermore, these experiments are commonly completed one at a time on cover slips of single cells, isotropic monolayers, or in isolated muscle strips. In all of these cases, variability of the samples hinders quantitative comparisons among experimental groups. Here, we report the design of a “heart on a chip” that exploits muscular thin film technology – biohybrid constructs of an engineered, anisotropic ventricular myocardium on an elastomeric thin film – to measure contractility, combined with a quantification of action potential propagation, and cytoskeletal architecture in multiple tissues in the same experiment. We report techniques for real-time data collection and analysis during pharmacological intervention. The chip is an efficient means of measuring structure-function relationships in constructs that replicate the hierarchical tissue architectures of laminar cardiac muscle.

481 citations


Journal ArticleDOI
TL;DR: The development of a microfluidic device for the separation of CTCs from blood cells based on the physical properties of cells and the serial combination of these two different sorting techniques enabled high-speed continuous flow-through separation without labeling is presented.
Abstract: Circulating tumor cells (CTCs) are highly correlated with the invasive behavior of cancer, so their isolations and quantifications are important for biomedical applications such as cancer prognosis and measuring the responses to drug treatments. In this paper, we present the development of a microfluidic device for the separation of CTCs from blood cells based on the physical properties of cells. For use as a CTC model, we successfully separated human breast cancer cells (MCF-7) from a spiked blood cell sample by combining multi-orifice flow fractionation (MOFF) and dielectrophoretic (DEP) cell separation technique. Hydrodynamic separation takes advantage of the massive and high-throughput filtration of blood cells as it can accommodate a very high flow rate. DEP separation plays a role in precise post-processing to enhance the efficiency of the separation. The serial combination of these two different sorting techniques enabled high-speed continuous flow-through separation without labeling. We observed up to a 162-fold increase in MCF-7 cells at a 126 µL min−1 flow rate. Red and white blood cells were efficiently removed with separation efficiencies of 99.24% and 94.23% respectively. Therefore, we suggest that our system could be used for separation and detection of CTCs from blood cells for biomedical applications.

423 citations


Journal ArticleDOI
TL;DR: A generic single cell manipulation tool that integrates optical tweezers and microfluidic chip technologies for handling small cell population sorting with high accuracy and high recovery rate and purity is reported on.
Abstract: Sorting (or isolation) and manipulation of rare cells with high recovery rate and purity are of critical importance to a wide range of physiological applications. In the current paper, we report on a generic single cell manipulation tool that integrates optical tweezers and microfluidic chip technologies for handling small cell population sorting with high accuracy. The laminar flow nature of microfluidics enables the targeted cells to be focused on a desired area for cell isolation. To recognize the target cells, we develop an image processing methodology with a recognition capability of multiple features, e.g., cell size and fluorescence label. The target cells can be moved precisely by optical tweezers to the desired destination in a noninvasive manner. The unique advantages of this sorter are its high recovery rate and purity in small cell population sorting. The design is based on dynamic fluid and dynamic light pattern, in which single as well as multiple laser traps are employed for cell transportation, and a recognition capability of multiple cell features. Experiments of sorting yeast cells and human embryonic stem cells are performed to demonstrate the effectiveness of the proposed cell sorting approach.

389 citations


Journal ArticleDOI
TL;DR: These polymer alternatives to PDMS, TPE, PUMA and NOA, have some considerable strengths for rapid prototyping when bond strength, predictable operation at high pressure, or transitioning to commercialization are considered important for the application.
Abstract: Multiple methods of fabrication exist for microfluidic devices, with different advantages depending on the end goal of industrial mass production or rapid prototyping for the research laboratory. Polydimethylsiloxane (PDMS) has been the mainstay for rapid prototyping in the academic microfluidics community, because of its low cost, robustness and straightforward fabrication, which are particularly advantageous in the exploratory stages of research. However, despite its many advantages and its broad use in academic laboratories, its low elastic modulus becomes a significant issue for high pressure operation as it leads to a large alteration of channel geometry. Among other consequences, such deformation makes it difficult to accurately predict the flow rates in complex microfluidic networks, change flow speed quickly for applications in stop-flow lithography, or to have predictable inertial focusing positions for cytometry applications where an accurate alignment of the optical system is critical. Recently, other polymers have been identified as complementary to PDMS, with similar fabrication procedures being characteristic of rapid prototyping but with higher rigidity and better resistance to solvents; Thermoset Polyester (TPE), Polyurethane Methacrylate (PUMA) and Norland Adhesive 81 (NOA81). In this review, we assess these different polymer alternatives to PDMS for rapid prototyping, especially in view of high pressure injections with the specific example of inertial flow conditions. These materials are compared to PDMS, for which magnitudes of deformation and dynamic characteristics are also characterized. We provide a complete and systematic analysis of these materials with side-by-side experiments conducted in our lab that also evaluate other properties, such as biocompatibility, solvent compatibility, and ease of fabrication. We emphasize that these polymer alternatives, TPE, PUMA and NOA, have some considerable strengths for rapid prototyping when bond strength, predictable operation at high pressure, or transitioning to commercialization are considered important for the application.

388 citations


Journal ArticleDOI
TL;DR: A new method of microchip-based Immunomagnetic CTC detection, in which the benefits of both immunomagnetic assay and the microfluidic device are combined is described, which is more than five times faster than those reported previously with a microchannel-based assay.
Abstract: Screening for circulating tumor cells (CTCs) in blood has been an object of interest for evidence of progressive disease, status of disease activity, recognition of clonal evolution of molecular changes and for possible early diagnosis of cancer. We describe a new method of microchip-based immunomagnetic CTC detection, in which the benefits of both immunomagnetic assay and the microfluidic device are combined. As the blood sample flows through the microchannel closely above arrayed magnets, cancer cells labeled with magnetic nanoparticles are separated from blood flow and deposited at the bottom wall of the glass coverslip, which allows direct observation of captured cells with a fluorescence microscope. A polydimethylsiloxane (PDMS)-based microchannel fixed on a glass coverslip was used to screen blood samples. The thin, flat dimensions of the microchannel, combined with the sharp magnetic field gradient in the vicinity of arrayed magnets with alternate polarities, lead to an effective capture of labeled cells. Compared to the commercially available CellSearch™ system, fewer (25%) magnetic particles are required to achieve a comparable capture rate, while the screening speed (at an optimal blood flow rate of 10 mL h−1) is more than five times faster than those reported previously with a microchannel-based assay. For the screening experiment, blood drawn from healthy subjects into CellSave™ tubes was spiked with cultured cancer cell lines of COLO205 and SKBR3. The blood was then kept at room temperature for 48 hours before the screening, emulating the actual clinical cases of blood screening. Customized Fe3O4 magnetic nanoparticles (Veridex Ferrofluid™) conjugated to anti-epithelial cell adhesion molecule (EpCAM) antibodies were introduced into the blood samples to label cancer cells, and the blood was then run through the microchip device to capture the labelled cells. After capture, the cells were stained with fluorescent labelled anti-cytokeratin, DAPI and anti-CD45. Subsequent immunofluorescence images were taken for the captured cells, followed by comprehensive computer aided analysis based on fluorescence intensities and cell morphology. Rare cancer cells (from ∼1000 cells down to ∼5 cells per mL) with very low tumor cell to blood cell ratios (about 1 : 107 to 109, including red blood cells) were successfully detected. Cancer cell capture rates of 90% and 86% were demonstrated for COLO205 and SKBR3 cells, respectively.

382 citations


Journal ArticleDOI
TL;DR: With no need for thermal cycling, isothermal microsystems can be designed to be simple and low-energy consuming and therefore may outperform PCR in portable, battery-operated detection systems in the future.
Abstract: Micro-Total Analysis Systems (µTAS) for use in on-site rapid detection of DNA or RNA are increasingly being developed. Here, amplification of the target sequence is key to increasing sensitivity, enabling single-cell and few-copy nucleic acid detection. The several advantages to miniaturizing amplification reactions and coupling them with sample preparation and detection on the same chip are well known and include fewer manual steps, preventing contamination, and significantly reducing the volume of expensive reagents. To-date, the majority of miniaturized systems for nucleic acid analysis have used the polymerase chain reaction (PCR) for amplification and those systems are covered in previous reviews. This review provides a thorough overview of miniaturized analysis systems using alternatives to PCR, specifically isothermal amplification reactions. With no need for thermal cycling, isothermal microsystems can be designed to be simple and low-energy consuming and therefore may outperform PCR in portable, battery-operated detection systems in the future. The main isothermal methods as miniaturized systems reviewed here include nucleic acid sequence-based amplification (NASBA), loop-mediated isothermal amplification (LAMP), helicase-dependent amplification (HDA), rolling circle amplification (RCA), and strand displacement amplification (SDA). Also, important design criteria for the miniaturized devices are discussed. Finally, the potential of miniaturization of some new isothermal methods such as the exponential amplification reaction (EXPAR), isothermal and chimeric primer-initiated amplification of nucleic acids (ICANs), signal-mediated amplification of RNA technology (SMART) and others is presented.

377 citations


Journal ArticleDOI
TL;DR: A novel and easy method for multiplexing dPCR in picolitre droplets within emulsions-generated and read out in microfluidic devices-that takes advantage of both the very high numbers of reactions possible within emulsion as well as the high likelihood that the amplification of only a single target DNA molecule will initiate within each droplet.
Abstract: Quantitative polymerase chain reactions (qPCR) based on real-time PCR constitute a powerful and sensitive method for the analysis of nucleic acids. However, in qPCR, the ability to multiplex targets using differently colored fluorescent probes is typically limited to 4-fold by the spectral overlap of the fluorophores. Furthermore, multiplexing qPCR assays requires expensive instrumentation and most often lengthy assay development cycles. Digital PCR (dPCR), which is based on the amplification of single target DNA molecules in many separate reactions, is an attractive alternative to qPCR. Here we report a novel and easy method for multiplexing dPCR in picolitre droplets within emulsions—generated and read out in microfluidic devices—that takes advantage of both the very high numbers of reactions possible within emulsions (>106) as well as the high likelihood that the amplification of only a single target DNA molecule will initiate within each droplet. By varying the concentration of different fluorogenic probes of the same color, it is possible to identify the different probes on the basis of fluorescence intensity. Adding multiple colors increases the number of possible reactions geometrically, rather than linearly as with qPCR. Accurate and precise copy numbers of up to sixteen per cell were measured using a model system. A 5-plex assay for spinal muscular atrophy was demonstrated with just two fluorophores to simultaneously measure the copy number of two genes (SMN1 and SMN2) and to genotype a single nucleotide polymorphism (c.815A>G, SMN1). Results of a pilot study with SMA patients are presented.

352 citations


Journal ArticleDOI
TL;DR: A high-throughput size-based separation method for processing diluted blood using inertial microfluidics is introduced, demonstrating the isolation of cancer cells spiked in blood by exploiting the difference in size between CTCs and hematologic cells.
Abstract: Blood is a highly complex bio-fluid with cellular components making up >40% of the total volume, thus making its analysis challenging and time-consuming. In this work, we introduce a high-throughput size-based separation method for processing diluted blood using inertial microfluidics. The technique takes advantage of the preferential cell focusing in high aspect-ratio microchannels coupled with pinched flow dynamics for isolating low abundance cells from blood. As an application of the developed technique, we demonstrate the isolation of cancer cells (circulating tumor cells (CTCs)) spiked in blood by exploiting the difference in size between CTCs and hematologic cells. The microchannel dimensions and processing parameters were optimized to enable high throughput and high resolution separation, comparable to existing CTC isolation technologies. Results from experiments conducted with MCF-7 cells spiked into whole blood indicate >80% cell recovery with an impressive 3.25 × 10(5) fold enrichment over red blood cells (RBCs) and 1.2 × 10(4) fold enrichment over peripheral blood leukocytes (PBL). In spite of a 20× sample dilution, the fast operating flow rate allows the processing of ∼10(8) cells min(-1) through a single microfluidic device. The device design can be easily customized for isolating other rare cells from blood including peripheral blood leukocytes and fetal nucleated red blood cells by simply varying the 'pinching' width. The advantage of simple label-free separation, combined with the ability to retrieve viable cells post enrichment and minimal sample pre-processing presents numerous applications for use in clinical diagnosis and conducting fundamental studies.

351 citations


Journal ArticleDOI
TL;DR: Powered by pre-evacuation of its PDMS substrate, SIMBAS' guiding design principle is the integration of the minimal number of components without sacrificing effectiveness in performing rapid complete bioassays, a critical step towards point-of-care molecular diagnostics.
Abstract: We present a self-powered integrated microfluidic blood analysis system (SIMBAS) that does not require any external connections, tethers, or tubing to deliver and analyze a raw whole-blood sample. SIMBAS only requires the user to place a 5 μL droplet of whole-blood at the inlet port of the device, whereupon the stand-alone SIMBAS performs on-chip removal of red and white cells, without external valving or pumping mechanisms, followed by analyte detection in platelet-containing plasma. Five complete biotin–streptavidin sample-to-answer assays are performed in 10 min; the limit of detection is 1.5 pM. Red and white blood cells are removed by trapping them in an integral trench structure. Simulations and experimental data show 99.9% to 100% blood cell retention in the passive structure. Powered by pre-evacuation of its PDMS substrate, SIMBAS' guiding design principle is the integration of the minimal number of components without sacrificing effectiveness in performing rapid complete bioassays, a critical step towards point-of-care molecular diagnostics.

Journal ArticleDOI
TL;DR: This compact and cost-effective fluorescent imaging platform attached to a cell-phone could provide an important tool for wide-field imaging and quantification of various lab-on-a-chip assays developed for global health applications, such as monitoring of HIV+ patients for CD4 counts or viral load measurements.
Abstract: We demonstrate wide-field fluorescent and darkfield imaging on a cell-phone with compact, light-weight and cost-effective optical components that are mechanically attached to the existing camera unit of the cell-phone. For this purpose, we used battery powered light-emitting diodes (LEDs) to pump the sample of interest from the side using butt-coupling, where the pump light was guided within the sample cuvette to uniformly excite the specimen. The fluorescent emission from the sample was then imaged using an additional lens that was positioned right in front of the existing lens of the cell-phone camera. Because the excitation occurs through guided waves that propagate perpendicular to our detection path, an inexpensive plastic colour filter was sufficient to create the dark-field background required for fluorescent imaging, without the need for a thin-film interference filter. We validate the performance of this platform by imaging various fluorescent micro-objects in 2 colours (i.e., red and green) over a large field-of-view (FOV) of ∼81 mm2 with a raw spatial resolution of ∼20 μm. With additional digital processing of the captured cell-phone images, through the use of compressive sampling theory, we demonstrate ∼2 fold improvement in our resolving power, achieving ∼10 μm resolution without a trade-off in our FOV. Further, we also demonstrate darkfield imaging of non-fluorescent specimen using the same interface, where this time the scattered light from the objects is detected without the use of any filters. The capability of imaging a wide FOV would be exceedingly important to probe large sample volumes (e.g., >0.1 mL) of e.g., blood, urine, sputum or water, and for this end we also demonstrate fluorescent imaging of labeled white-blood cells from whole blood samples, as well as water-borne pathogenic protozoan parasites such as Giardia Lamblia cysts. Weighing only ∼28 g (∼1 ounce), this compact and cost-effective fluorescent imaging platform attached to a cell-phone could be quite useful especially for resource-limited settings, and might provide an important tool for wide-field imaging and quantification of various lab-on-a-chip assays developed for global health applications, such as monitoring of HIV+ patients for CD4 counts or viral load measurements.

Journal ArticleDOI
TL;DR: This work demonstrates both end-point and real-time imaging ability to perform on-chip quantitative digital PCR analysis of the entire droplet array, and yields a 100-fold increase in the number of on- chip digitized reactors with simultaneous fluorescence imaging for digital PCR based assays.
Abstract: Digital droplet reactors are useful as chemical and biological containers to discretize reagents into picolitre or nanolitre volumes for analysis of single cells, organisms, or molecules. However, most DNA based assays require processing of samples on the order of tens of microlitres and contain as few as one to as many as millions of fragments to be detected. Presented in this work is a droplet microfluidic platform and fluorescence imaging setup designed to better meet the needs of the high-throughput and high-dynamic-range by integrating multiple high-throughput droplet processing schemes on the chip. The design is capable of generating over 1-million, monodisperse, 50 picolitre droplets in 2–7 minutes that then self-assemble into high density 3-dimensional sphere packing configurations in a large viewing chamber for visualization and analysis. This device then undergoes on-chip polymerase chain reaction (PCR) amplification and fluorescence detection to digitally quantify the sample's nucleic acid contents. Wide-field fluorescence images are captured using a low cost 21-megapixel digital camera and macro-lens with an 8–12 cm2 field-of-view at 1× to 0.85× magnification, respectively. We demonstrate both end-point and real-time imaging ability to perform on-chip quantitative digital PCR analysis of the entire droplet array. Compared to previous work, this highly integrated design yields a 100-fold increase in the number of on-chip digitized reactors with simultaneous fluorescence imaging for digital PCR based assays.

Journal ArticleDOI
Jinghua Yu1, Lei Ge1, Jiadong Huang1, Shoumei Wang1, Shenguang Ge1 
TL;DR: This study shows the successful integration of the μPCAD and the chemiluminescence method will be an easy-to-use, inexpensive, and portable alternative for point-of-care monitoring.
Abstract: In this study, a novel microfluidic paper-based chemiluminescence analytical device (μPCAD) with a simultaneous, rapid, sensitive and quantitative response for glucose and uric acid was designed. This novel lab-on-paper biosensor is based on oxidase enzyme reactions (glucose oxidase and urate oxidase, respectively) and the chemiluminescence reaction between a rhodanine derivative and generated hydrogen peroxide in an acid medium. The possible chemiluminescence assay principle of this μPCAD is explained. We found that the simultaneous determination of glucose and uric acid could be achieved by differing the distances that the glucose and uric acid samples traveled. This lab-on-paper biosensor could provide reproducible results upon storage at 4 °C for at least 10 weeks. The application test of our μPCAD was then successfully performed with the simultaneous determination of glucose and uric acid in artificial urine. This study shows the successful integration of the μPCAD and the chemiluminescence method will be an easy-to-use, inexpensive, and portable alternative for point-of-care monitoring.

Journal ArticleDOI
Jong Hwan Sung1, Jiajie Yu1, Dan Luo1, Michael L. Shuler1, John C. March1 
TL;DR: Combination of laser ablation and sacrificial molding technique using calcium alginate minimizes the stress associated with separating the mold from the hydrogel structure, and therefore allows fabrication of complex structures without damaging them.
Abstract: Here we describe a simple and efficient method for fabricating natural and synthetic hydrogels into 3-D geometries with high aspect ratio and curvature. Fabricating soft hydrogels into such shapes using conventional techniques has been extremely difficult. Combination of laser ablation and sacrificial molding technique using calcium alginate minimizes the stress associated with separating the mold from the hydrogel structure, and therefore allows fabrication of complex structures without damaging them. As a demonstration of this technique, we have fabricated a microscale collagen structure mimicking the actual density and size of human intestinal villi. Colon carcinoma cell line, Caco-2 cells, was seeded onto the structure and cultured for 3 weeks until the whole structure was covered, forming finger-like structures mimicking the intestinal villi covered with epithelial cells. This method will enable construction of in vitro tissue models with physiologically realistic geometries at microscale resolutions.

Journal ArticleDOI
TL;DR: This results constitute the first-time that a lensfree on-chip microscope has successfully imaged malaria parasites and would be important for global health problems such as diagnosis of infectious diseases in remote locations.
Abstract: We report a portable lensless on-chip microscope that can achieve <1 µm resolution over a wide field-of-view of ∼24 mm2 without the use of any mechanical scanning. This compact on-chip microscope weighs ∼95 g and is based on partially coherent digital in-line holography. Multiple fiber-optic waveguides are butt-coupled to light emitting diodes, which are controlled by a low-cost micro-controller to sequentially illuminate the sample. The resulting lensfree holograms are then captured by a digital sensor-array and are rapidly processed using a pixel super-resolution algorithm to generate much higher resolution holographic images (both phase and amplitude) of the objects. This wide-field and high-resolution on-chip microscope, being compact and light-weight, would be important for global health problems such as diagnosis of infectious diseases in remote locations. Toward this end, we validate the performance of this field-portable microscope by imaging human malaria parasites (Plasmodium falciparum) in thin blood smears. Our results constitute the first-time that a lensfree on-chip microscope has successfully imaged malaria parasites.

Journal ArticleDOI
TL;DR: The modified surface exhibited a highly porous structure which helped to trap/localize chemical and biological aqueous reagents for analysis and the applicability of this platform to perform chemical reactions using luminol-based hemoglobin detection was demonstrated.
Abstract: We report a method for fabricating inexpensive microfluidic platforms on paper using laser treatment. Any paper with a hydrophobic surface coating (e.g., parchment paper, wax paper, palette paper) can be used for this purpose. We were able to selectively modify the surface structure and property (hydrophobic to hydrophilic) of several such papers using a CO2 laser. We created patterns down to a minimum feature size of 62 ± 1 µm. The modified surface exhibited a highly porous structure which helped to trap/localize chemical and biological aqueous reagents for analysis. The treated surfaces were stable over time and were used to self-assemble arrays of aqueous droplets. Furthermore, we selectively deposited silica microparticles on patterned areas to allow lateral diffusion from one end of a channel to the other. Finally, we demonstrated the applicability of this platform to perform chemical reactions using luminol-based hemoglobin detection.

Journal ArticleDOI
TL;DR: A novel method for sheathless particle focusing, called "Elasto-Inertial Particle Focusing", was demonstrated in a straight microchannel and it is expected that this method can contribute to develop the miniaturized flow cytometry and microdevices for cell and particle manipulation.
Abstract: Particle focusing in planar geometries is essentially required in order to develop cost-effective lab-on-a-chips, such as cell counting and point-of-care (POC) devices. In this study, a novel method for sheathless particle focusing, called “Elasto-Inertial Particle Focusing”, was demonstrated in a straight microchannel. The particles were notably aligned along the centerline of the straight channel under a pressure-driven flow without any additional external force or apparatus after the addition of an elasticity enhancer: PEO (poly(ethylene oxide)) (∼O(100) ppm). As theoretically predicted (elasticity number: El ≈ O(100)), multiple equilibrium positions (centerline and corners) were observed for the viscoelastic flow without inertia, whereas three-dimensional particle focusing only occurred when neither the elasticity nor the inertia was negligible. Therefore, the three-dimensional particle focusing mechanism was attributed to the synergetic combination of the elasticity and the inertia (elasticity number: El ≈ O(1–10)). Furthermore, from the size dependence of the elastic force upon particles, we demonstrated that a mixture of 5.9 and 2.4 µm particles was separated at the exit of the channel in viscoelastic flows. We expect that this method can contribute to develop the miniaturized flow cytometry and microdevices for cell and particle manipulation.

Journal ArticleDOI
TL;DR: A versatile centrifuge-analogue may open opportunities in automated, low-cost and high-throughput sample preparation as an alternative to the standard benchtop centrifuge in standardized clinical diagnostics or resource poor settings.
Abstract: The standard centrifuge is a laboratory instrument widely used by biologists and medical technicians for preparing cell samples. Efforts to automate the operations of concentration, cell separation, and solution exchange that a centrifuge performs in a simpler and smaller platform have had limited success. Here, we present a microfluidic chip that replicates the functions of a centrifuge without moving parts or external forces. The device operates using a purely fluid dynamic phenomenon in which cells selectively enter and are maintained in microscale vortices. Continuous and sequential operation allows enrichment of cancer cells from spiked blood samples at the mL min−1 scale, followed by fluorescent labeling of intra- and extra-cellular antigens on the cells without the need for manual pipetting and washing steps. A versatile centrifuge-analogue may open opportunities in automated, low-cost and high-throughput sample preparation as an alternative to the standard benchtop centrifuge in standardized clinical diagnostics or resource poor settings.

Journal ArticleDOI
Angela Walter1, Anne März1, Wilm Schumacher1, Petra Rösch1, Jürgen Popp1 
TL;DR: It is demonstrated that the requirements can be fulfilled by measuring ultrasonic busted bacteria by means of microfluidic lab-on-a-chip based SERS and the applied sample preparation, high specificity and reproducibility of the spectra are achieved.
Abstract: The interest in a fast, high specific and reliable detection method for bacteria identification is increasing. We will show that the application of vibrational spectroscopy is feasible for the validation of bacteria in microfluidic devices. For this purpose, reproducible and specific spectral pattern as well as the establishment of large databases are essential for statistical analysis. Therefore, short recording times are beneficial concerning the time aspect of fast identification. We will demonstrate that the requirements can be fulfilled by measuring ultrasonic busted bacteria by means of microfluidic lab-on-a-chip based SERS. With the applied sample preparation, high specificity and reproducibility of the spectra are achieved. Taking advantage of the SERS enhancement, the spectral recording time is reduced to 1 s and a database of 11 200 spectra is established for a model system E. coli including nine different strains. The validation of the bacteria on strain level is achieved accomplishing SVM accuracies of 92%. Within this contribution the potential of our approach of bacterial identification for future application is discussed, focusing on the time-benefit and the combination with other microfluidic applications.

Journal ArticleDOI
TL;DR: This review will provide a comprehensive overview of chip based immunosensing technology as applied to cardiac biomarker detection, while discussing the potential suitability and limitations of each configuration for incorporation within a clinical diagnostics device suitable for point-of-care applications.
Abstract: This review examines the current state of the art lab-on-a-chip and microfluidic based biosensor technologies used in the detection of cardiac biomarkers. The determination and quantification of blood based, cardiac biomarkers are crucial in the triage and management of a range of cardiac related conditions, where time delay has a major impact on short and longer-term outcomes of a patient. The design and manufacturing of biomarker detection systems are multi-disciplinary in nature and require researchers to have knowledge of both life sciences and engineering for the full potential of this field to be realised. This review will therefore provide a comprehensive overview of chip based immunosensing technology as applied to cardiac biomarker detection, while discussing the potential suitability and limitations of each configuration for incorporation within a clinical diagnostics device suitable for point-of-care applications.

Journal ArticleDOI
TL;DR: An automated microfabricated "deformability cytometer" is introduced that measures dynamic mechanical responses of 10(3) to 10(4) individual RBCs in a cell population, resulting in a population-based correlation between biochemical properties, such as cell surface markers, and dynamic mechanical deformability.
Abstract: Malaria resulting from Plasmodium falciparum infection is a major cause of human suffering and mortality. Red blood cell (RBC) deformability plays a major role in the pathogenesis of malaria. Here we introduce an automated microfabricated “deformability cytometer” that measures dynamic mechanical responses of 103 to 104 individual RBCs in a cell population. Fluorescence measurements of each RBC are simultaneously acquired, resulting in a population-based correlation between biochemical properties, such as cell surface markers, and dynamic mechanical deformability. This device is especially applicable to heterogeneous cell populations. We demonstrate its ability to mechanically characterize a small number of P. falciparum-infected (ring stage) RBCs in a large population of uninfected RBCs. Furthermore, we are able to infer quantitative mechanical properties of individual RBCs from the observed dynamic behavior through a dissipative particle dynamics (DPD) model. These methods collectively provide a systematic approach to characterize the biomechanical properties of cells in a high-throughput manner.

Journal ArticleDOI
TL;DR: In this paper, a novel polymer platform based on off-stoichiometry thiol-enes (OSTEs) is introduced to bridge the gap between research prototyping and commercial production of microfluidic devices.
Abstract: In this article we introduce a novel polymer platform based on off-stoichiometry thiol–enes (OSTEs), aiming to bridge the gap between research prototyping and commercial production of microfluidic devices. The polymers are based on the versatile UV-curable thiol–ene chemistry but takes advantage of off-stoichiometry ratios to enable important features for a prototyping system, such as one-step surface modifications, tuneable mechanical properties and leakage free sealing through direct UV-bonding. The platform exhibits many similarities with PDMS, such as rapid prototyping and uncomplicated processing but can at the same time mirror the mechanical and chemical properties of both PDMS as well as commercial grade thermoplastics. The OSTE-prepolymer can be cast using standard SU-8 on silicon masters and a table-top UV-lamp, the surface modifications are precisely grafted using a stencil mask and the bonding requires only a single UV-exposure. To illustrate the potential of the material we demonstrate key concepts important in microfluidic chip fabrication such as patterned surface modifications for hydrophobic stops, pneumatic valves using UV-lamination of stiff and rubbery materials as well as micromachining of chip-to-world connectors in the OSTE-materials.

Journal ArticleDOI
TL;DR: In this paper, a simple and inexpensive microchip ELISA-based detection module that employs a portable detection system, i.e., a cell phone/charge-coupled device (CCD) to quantify an ovarian cancer biomarker, HE4, in urine.
Abstract: Ovarian cancer is asymptomatic in the early stages and most patients present with advanced levels of disease. The lack of cost-effective methods that can achieve frequent, simple and non-invasive testing hinders early detection and causes high mortality in ovarian cancer patients. Here, we report a simple and inexpensive microchip ELISA-based detection module that employs a portable detection system, i.e., a cell phone/charge-coupled device (CCD) to quantify an ovarian cancer biomarker, HE4, in urine. Integration of a mobile application with a cell phone enabled immediate processing of microchip ELISA results, which eliminated the need for a bulky, expensive spectrophotometer. The HE4 level detected by a cell phone or a lensless CCD system was significantly elevated in urine samples from cancer patients (n = 19) than healthy controls (n = 20) (p < 0.001). Receiver operating characteristic (ROC) analyses showed that the microchip ELISA coupled with a cell phone running an automated analysis mobile application had a sensitivity of 89.5% at a specificity of 90%. Under the same specificity, the microchip ELISA coupled with a CCD had a sensitivity of 84.2%. In conclusion, integration of microchip ELISA with cell phone/CCD-based colorimetric measurement technology can be used to detect HE4 biomarker at the point-of-care (POC), paving the way to create bedside technologies for diagnostics and treatment monitoring.

Journal ArticleDOI
TL;DR: This work developed a new method to micropattern extracellular matrix proteins on poly-acrylamide gels in order to simultaneously control cell geometry and mechanics and found that, contrary to the current view, all transformation phenotypes were not always associated to an increased level of cell contractility.
Abstract: In tissues, cell microenvironment geometry and mechanics strongly impact on cell physiology. Surface micropatterning allows the control of geometry while deformable substrates of tunable stiffness are well suited for the control of the mechanics. We developed a new method to micropattern extracellular matrix proteins on poly-acrylamide gels in order to simultaneously control cell geometry and mechanics. Microenvironment geometry and mechanics impinge on cell functions by regulating the development of intra-cellular forces. We measured these forces in micropatterned cells. Micropattern geometry was streamlined to orient forces and place cells in comparable conditions. Thereby force measurement method could be simplified and applied to large-scale experiment on chip. We applied this method to mammary epithelial cells with traction force measurements in various conditions to mimic tumoral transformation. We found that, contrary to the current view, all transformation phenotypes were not always associated to an increased level of cell contractility.

Journal ArticleDOI
TL;DR: Some of the most common implementations of near-field photonics for trapping, transport and handling of nanomaterials are introduced, focusing on those which have relevance to microfluidic or optofluidic applications.
Abstract: In this article we review the use of near-field photonics for trapping, transport and handling of nanomaterials. While the advantages of traditional optical tweezing are well known at the microscale, direct application of these techniques to the handling of nanoscale materials has proven difficult due to unfavourable scaling of the fundamental physics. Recently a number of research groups have demonstrated how the evanescent fields surrounding photonic structures like photonic waveguides, optical resonators, and plasmonic nanoparticles can be used to greatly enhance optical forces. Here, we introduce some of the most common implementations of these techniques, focusing on those which have relevance to microfluidic or optofluidic applications. Since the field is still relatively nascent, we spend much of the article laying out the fundamental and practical advantages that near field optical manipulation offers over both traditional optical tweezing and other particle handling techniques. In addition we highlight three application areas where these techniques namely could be of interest to the lab-on-a-chip community, namely: single molecule analysis, nanoassembly, and optical chromatography.

Journal ArticleDOI
TL;DR: The most recent research and development of the past two years in SAW based particle and liquid droplet manipulation for lab-on-a-chip devices including particle focusing and separation, particle alignment and patterning, particle directing, and liquid Droplet delivery are reviewed.
Abstract: Manipulation of microscale particles and fluid liquid droplets is an important task for lab-on-a-chip devices for numerous biological researches and applications, such as cell detection and tissue engineering. Particle manipulation techniques based on surface acoustic waves (SAWs) appear effective for lab-on-a-chip devices because they are non-invasive, compatible with soft lithography micromachining, have high energy density, and work for nearly any type of microscale particles. Here we review the most recent research and development of the past two years in SAW based particle and liquid droplet manipulation for lab-on-a-chip devices including particle focusing and separation, particle alignment and patterning, particle directing, and liquid droplet delivery.

Journal ArticleDOI
TL;DR: An emulsification technique is introduced that creates monodisperse double-emulsion drops with a core-shell geometry having an ultra-thin wall as a middle layer, potentially useful for encapsulation and delivery of drugs, cosmetics, and nutrients.
Abstract: We introduce an emulsification technique that creates monodisperse double-emulsion drops with a core–shell geometry having an ultra-thin wall as a middle layer. We create a biphasic flow in a microfluidic capillary device by forming a sheath flow consisting of a thin layer of a fluid with high affinity to the capillary wall flowing along the inner wall of the capillary, surrounding the innermost fluid. This creates double-emulsion drops, using a single-step emulsification, having a very thin fluid shell. If the shell is solidified, its thickness can be small as a hundred nanometres or even less. Despite the small thickness of this shell, these structures are nevertheless very stable, giving them great potential for encapsulation. We demonstrate this by creating biodegradable microcapsules of poly(lactic acid) with a shell thickness of a few tens of nanometres, which are potentially useful for encapsulation and delivery of drugs, cosmetics, and nutrients.

Journal ArticleDOI
TL;DR: By modifying the method of deterministic lateral displacement, confining parasites and red blood cells in channels of optimized depth which accentuates morphological differences, the technique was able to achieve separation thus offering a potential route to diagnostics.
Abstract: We present the use of a simple microfluidic technique to separate living parasites from human blood. Parasitic trypanosomatids cause a range of human and animal diseases. African trypanosomes, responsible for human African trypanosomiasis (sleeping sickness), live free in the blood and other tissue fluids. Diagnosis relies on detection and due to their often low numbers against an overwhelming background of predominantly red blood cells it is crucial to separate the parasites from the blood. By modifying the method of deterministic lateral displacement, confining parasites and red blood cells in channels of optimized depth which accentuates morphological differences, we were able to achieve separation thus offering a potential route to diagnostics.

Journal ArticleDOI
TL;DR: The axon diode concept brings in a paradigmatic change in neuronal culture platforms, with potential applications for studying neuronal development, synaptic transmission and neurodegenerative disorder such as Alzheimer and Parkinson diseases at the sub-cellular, cellular and network levels.
Abstract: Various experimental models are used to study brain development and degeneration. They range from whole animal models, which preserve anatomical structures but strongly limit investigations at the cellular level, to dissociated cell culture systems that allow detailed observation of cell phenotypes but lack the highly ordered physiological neuron connection architecture. We describe here a platform comprising independent cell culture chambers separated by an array of “axonal diodes”. This array involves asymmetric micro-channels, imposing unidirectional axon connectivity with 97% selectivity. It allows the construction of complex, oriented neuronal networks not feasible with earlier platforms. Different neuronal subtypes could be co-cultivated for weeks, and sequential seeding of different cell populations reproduced physiological network development. To illustrate possible applications, we created and characterized a cortico-striatal oriented network. Functional synaptic connections were established. The activation of striatal differentiation by cortical axons, and the synchronization of neural activity were demonstrated. Each neuronal population and subcompartment could be chemically addressed individually. The directionality of neural pathways being a key feature of the nervous system organization, the axon diode concept brings in a paradigmatic change in neuronal culture platforms, with potential applications for studying neuronal development, synaptic transmission and neurodegenerative disorder such as Alzheimer and Parkinson diseases at the sub-cellular, cellular and network levels.