scispace - formally typeset
Search or ask a question
Journal ArticleDOI

3-D Isotropic Tactile Microprobe Based on a Silicon Parallelogram Kinematic: From Concept to Fabrication

TL;DR: In this paper, a tactile microprobe based on a parallelogram kinematic made from monocrystalline silicon is presented, which is optimized to allow very compact integration into a O11 mm housing.
Abstract: This paper reports on a unique tactile microprobe based on a parallelogram kinematic made from monocrystalline silicon. This kinematic, made out of an orthogonal cascade assembly of three identical parallelograms, provides an isotropic behavior to the microprobe. Each parallelogram deflects in only one direction thanks to thin elastic silicon membrane hinges and their displacements are recognized using piezoresistors integrated into these hinges. Wide deflection ranges, isotropic behavior, and low mechanical stiffness of the new microprobe, as predicted by simulations, could be verified in experiments. The fabrication, the assembly, and the contacting of the first microprobe prototype was optimized to allow very compact integration into a O11 mm housing. This make it suitable for metrology research laboratories and industries equipped with conventional coordinate measurement machines and even for a variety of other 3-D force/displacement measurements. [2018-0157]
Figures (21)

Content maybe subject to copyright    Report

Citations
More filters
Journal ArticleDOI
TL;DR: In this paper , the surface-sensing principles of micro-probe systems were the focus, and the characteristics were reviewed, including the performance trends of individual microprobe system with different sensing principles.
Abstract: Micro-coordinate measuring machines (micro-CMMs) for measuring microcomponents require a probe system with a probe tip diameter of several tens to several hundreds of micrometers. Scale effects work for such a small probe tip, i.e., the probe tip tends to stick on the measurement surface via surface adhesion forces. These surface adhesion forces significantly deteriorate probing resolution or repeatability. Therefore, to realize micro-CMMs, many researchers have proposed microprobe systems that use various surface-sensing principles compared with conventional CMM probes. In this review, the surface-sensing principles of microprobe systems were the focus, and the characteristics were reviewed. First, the proposed microprobe systems were summarized, and the probe performance trends were identified. Then, the individual microprobe system with different sensing principles was described to clarify the performance of each sensing principle. By comprehensively summarizing multiple types of probe systems and discussing their characteristics, this study contributed to identifying the performance limitations of the proposed micro-probe system. Accordingly, the future development of micro-CMMs probes is discussed.

12 citations

Journal ArticleDOI
TL;DR: In this article, the IMT-PTB microprobe is combined with a uniquely designed microenvironment, which facilitates and improves the measurement of workpieces with submillimeter features.
Abstract: This paper describes the experimental verification of the novel IMT-PTB microprobe combined with a uniquely designed microenvironment. The microprobe consists of three silicon-based parallelograms stacked orthogonally, which leads to high isotropy. The probe tip deflections are detected in 3D with the help of piezoresistors placed in the parallelograms. The microenvironment facilitates and improves the measurement of workpieces with submillimeter features. The new microprobe and the microenvironment were integrated into a commercial coordinate measuring machine (CMM). To evaluate the microprobe performance, PTB produced and calibrated three reference objects: a cube, a sphere, and a microgear measurement standard. The differences between the calibration values and the measurement results obtained by the microprobe were in the sub-micrometer range. Furthermore, the microprobe was compared with the standard probing system of the gear measuring machine by measuring the reference objects with identical parameters. The results show the excellent performance of the micro probing system, thereby extending the capability of the CMM for high-precision measurements of complex workpieces at the microscale.

8 citations


Cites background or methods from "3-D Isotropic Tactile Microprobe Ba..."

  • ...With the goal to facilitate this integration, a novel silicon microprobe based on a parallelogram design has been developed, presented [36, 37] and patented [38]....

    [...]

  • ...Finally, the cells and IPs were glued together in an aluminum machined special tool presented in [37]....

    [...]

  • ...27% was reported in [37] for a range of ±200 μm on X , Y , and +200 μm on Z ....

    [...]

  • ...The voltage was transmitted to each cell using pass-through tracks on the IPs and those on the front of the cells....

    [...]

  • ...To complete the assembly, all tracks of the cells were hand-soldered to one of the IPs [37]....

    [...]

Journal ArticleDOI
TL;DR: In this article , a flexible capacitive tactile sensing array that incorporates a porous dielectric layer with micro-patterned structures on the surface to enable the sensitive detection of normal and shear pressures was presented.
Abstract: The development of pressure sensors of high sensitivity and stable robustness over a broad range is indispensable for the future progress of electronic skin applicable to the detection of normal and shear pressures of various dynamic human motions. Herein, we present a flexible capacitive tactile sensing array that incorporates a porous dielectric layer with micro-patterned structures on the surface to enable the sensitive detection of normal and shear pressures. The proposed sensing array showed great pressure-sensing performance in the experiments, with a broad sensing range from several kPa to 150 kPa of normal pressure and 20 kPa of shear pressure. Sensitivities of 0.54%/kPa at 10 kPa and below, 0.45%/kPa between 10 kPa and 80 kPa, and 0.12%/kPa at 80 kPa and above were achieved for normal pressures. Meanwhile, for shear pressures, sensitivities up to 1.14%/kPa and 1.08%/kPa in x and y directions, respectively, and below 10 kPa, 0.73%/kPa, and 0.75%/kPa under shear pressure over 10 kPa were also validated. The performance of the finger-attached sensing array was also demonstrated, demonstrating which was a potential electronic skin to use in all kinds of wearable devices, including prosthetic hands, surgical robots, and other pressure monitoring systems.

3 citations

Journal ArticleDOI
TL;DR: In this article , a two-step plus hinge stylus with a diameter less than a few micrometers was proposed to improve sensitivity and vibration characteristics of the stylus tip.
Abstract: In recent years, there has been an increasing demand for measuring a small hole with a diameter of 10 μm or less. Many micro coordinate measuring machines (micro CMMs) have been developed so far. However, as the diameters of these probes decrease below 10 μm, the rigidity of the probe decreases, making it difficult to detect contact between the stylus tip and the measured surface. For the same reason, the stylus with large aspect ratios cannot be used. Therefore, we have been developing a measurement system using an optical fiber as a stylus to measure microstructures with low measurement force. In this research, we proposed the two-step plus hinge stylus with a diameter less than a few μm to improve sensitivity and vibration characteristics. The design parameters of the stylus were simulated by the finite element method, and the results of the actual examination are summarized as follows. The simulation results using the finite element method indicate that the contact sensitivity was improved from 17% for the standard stylus to 37% for the two-step plus hinge stylus. The experimental results indicate that the contact sensitivity was improved from 17% for the standard stylus to 35% for the two-step plus hinge stylus. The results of the stylus stability evaluation experiment showed that the maximum fluctuation of the standard stylus is approximately 1 μm, and that of the two-step plus hinge stylus is approximately 0.05 μm, which confirms that the use of a two-step plus hinge stylus can improve vibration characteristics. The performance of this stylus was evaluated by measuring the micro hole with a diameter of 7 μm. The repeatability of each measurement point was approximately 50 nm.

1 citations

Proceedings ArticleDOI
23 Jun 2019
TL;DR: In this paper, a fully functional silicon-based microprobe consisting of three identical measuring cells mounted orthogonally has been developed, each offering a large measuring range and low stiffness in only one direction thanks to a silicon parallelogram structure.
Abstract: A fully-functional silicon-based microprobe consisting of three identical measuring cells mounted orthogonally has been developed. The microfabricated measuring cells act as miniaturized load cells, each offering a large measuring range and low stiffness in only one direction thanks to a silicon parallelogram structure. The microassembly of three parallelogram structures using interposers results in an isotropic 3D kinematic microprobe. Piezoresistive sensing provides sub-micrometer accuracy. Highly reproducible and reliable manufacturing processes such as anodic bonding were recently introduced to build the measuring cell. In addition to the standard mechanical and electrical characterization of the microprobe, a dynamic characterization was performed. It was demonstrated that the new microprobe can be used in a commercial coordinate measuring machine (CMM) thereby extending its applicability for dimensional measurement of microcomponents.

1 citations


Cites background or methods from "3-D Isotropic Tactile Microprobe Ba..."

  • ...In addition to a characterization already given in [6], the frequency response of the measuring cell and of the microprobe is detailed....

    [...]

  • ...Table 1: Properties of isotropic microprobe [6, 10]....

    [...]

  • ...In previous work [6, 10], the properties of the single (glued) measuring cells and the 3D microprobe were described in detail....

    [...]

  • ...In contrast to earlier concepts, adhesive bonding [6] is replaced by the more reproducible and reliable anodic bonding of two silicon wafers using a structured intermediate glass substrate....

    [...]

  • ...A thin polyimide film coated with epoxy adhesive was used to transfer the adhesive on the surfaces to bond [6, 10]....

    [...]

References
More filters
Journal ArticleDOI
07 Aug 2014
TL;DR: In this paper, the vibrational properties of single crystal Si and Ge were studied between room and melting temperature Tm using the impulse excitation technique and the temperature dependent Young's moduli E are extracted in the -, - and - directions.
Abstract: The vibrational properties of single crystal Si and Ge are studied between room and melting temperature Tm using the impulse excitation technique. From the measurements, the temperature dependent Young's moduli E are extracted in the -, - and - directions. For both semiconductors, the Young's moduli decrease smoothly with increasing temperature and retain high values up to Tm. Using the semi-empiric Wachtman's equation allows an excellent fit to the experimental data for the temperature dependence of E , E and E between room temperature and 0.6Tm,. For higher temperatures, the Young's moduli decrease faster than predicted by Wachtman's equation. In the case of Ge, an apparent enhanced softening is observed starting from about 850 oC which is due to a loss of Ge material, leading to a decrease of sample dimensions and weight.

26 citations

Proceedings ArticleDOI
21 Nov 2003
TL;DR: In this paper, a Coordinate Measuring Machine (CMM) is developed which operates over a working volume of 50 x 50 × 50 mm, and achieves an uncertainty in any measured 3D coordinate of ~100 nm.
Abstract: A Coordinate Measuring Machine (CMM) has been developed which operates over a working volume of 50 x 50 x 50 mm, and achieves an uncertainty in any measured 3D coordinate of ~100 nm. This miniature CMM is based around the concept of a metrology frame, mounted on a host CMM, with a miniature probe system held on the host CMM's ram. The probing system is rigidly connected to 3 orthogonal mirrors, the positions and rotations of which are measured using 3 duel-axis interferometers (length, angle) and 3 duel-axis angular sensors. Corrections for the mis-alignments of the interferometers, flatness errors of the mirrors and performance of the miniature probe system are all determined in situ, by reference to a calibrated laser wavelength. This process determines a complete error map of the CMM and requires only two artefacts: a precision sphere and a good quality optical cube. The error map is used online to determine the 3D position of the probe tip, based on measurements of the interferometers and angle sensing systems. The CMM is fully programmable and operates as a normal CMM, but with considerably improved accuracy. The design, operation and calibration of the CMM are described, followed by examples of measurements made with the machine and a determination of the uncertainty sources. This CMM is designed as the first step in bridging the gap between conventional (millimeter scale metrology) and nanometrology.

21 citations

Journal ArticleDOI
TL;DR: In this paper, the integration of silicon micro probing systems into conventional gear measuring instruments (GMIs) allows fully automated measurements of external involute micro spur gears of normal modules smaller than 1 mm.
Abstract: The integration of silicon micro probing systems into conventional gear measuring instruments (GMIs) allows fully automated measurements of external involute micro spur gears of normal modules smaller than 1 mm. This system, based on a silicon microprobe, has been developed and manufactured at the Institute for Microtechnology of the Technische Universitat Braunschweig. The microprobe consists of a silicon sensor element and a stylus which is oriented perpendicularly to the sensor. The sensor is fabricated by means of silicon bulk micromachining. Its small dimensions of 6.5 mm × 6.5 mm allow compact mounting in a cartridge to facilitate the integration into a GMI. In this way, tactile measurements of 3D microstructures can be realized. To enable three-dimensional measurements with marginal forces, four Wheatstone bridges are built with diffused piezoresistors on the membrane of the sensor. On the reverse of the membrane, the stylus is glued perpendicularly to the sensor on a boss to transmit the probing forces to the sensor element during measurements. Sphere diameters smaller than 300 µm and shaft lengths of 5 mm as well as measurement forces from 10 µN enable the measurements of 3D microstructures. Such micro probing systems can be integrated into universal coordinate measuring machines and also into GMIs to extend their field of application. Practical measurements were carried out at the Physikalisch-Technische Bundesanstalt by qualifying the microprobes on a calibrated reference sphere to determine their sensitivity and their physical dimensions in volume. Following that, profile and helix measurements were carried out on a gear measurement standard with a module of 1 mm. The comparison of the measurements shows good agreement between the measurement values and the calibrated values. This result is a promising basis for the realization of smaller probe diameters for the tactile measurement of micro gears with smaller modules.

20 citations


"3-D Isotropic Tactile Microprobe Ba..." refers result in this paper

  • ...4) Towards Industrial Application: In ongoing research in collaboration with the PTB, the integration of the microprobe in a conventional CMM is investigated with the patended new design [55] in an approach, which is similar to the one reported earlier with other probe designs [23], [56]....

    [...]

Journal ArticleDOI
TL;DR: In this article, the authors report on the design and testing of several new piezoresistive ultra high precision 3D microprobes for the use in coordinate measuring machines (CMM).

14 citations

Journal ArticleDOI
TL;DR: In this paper, weiterentwickelte und optimierte design eines auf Bulk-Silizium-Technologie basierenden 3-D-Kraftsensors wird beschrieben.
Abstract: Abstract Das weiterentwickelte und optimierte Design eines auf Bulk-Silizium-Technologie basierenden 3-D-Kraftsensors wird beschrieben. In vorangegangenen Untersuchungen konnte gezeigt werden, dass sich dieser Kraftsensor zum Einsatz in der taktilen Wegmesstechnik als Antastsensor eignet. Das Sensorelement besteht aus einer mit mikrotechnischen Herstellungsverfahren gefertigten Silizium-Bossmembran. In diesem Bericht wird ein neues Design und eine neue Auswertungsstrategie für diesen Sensortyp beschrieben.

12 citations

Frequently Asked Questions (1)
Q1. What are the contributions in this paper?

This work reports on a unique tactile microprobe based on a parallelogram kinematic made from monocrystalline silicon. This kinematic, made out of an orthogonal cascade assembly of three identical parallelograms, provides an isotropic behavior to the microprobe. This make it suitable for metrology research laboratories as well as industries equipped with conventional coordinate measurement machines and even for a variety of other 3D force/displacement measurements.